NOTICE OF VIOLATION

,LW

, - g.

.VihginiaElectric&'PowerCompany

-Docket Nos. 50 338 and:50-339 g

North._ Anna ~

License Nos. NPF-4 and NPF-7

' The - following' violations were. identified during an -inspection conducted - on December 6, _ _1984 - January 5,'

1985.

The Severity Levels were assigned 11n accordance with-the.NRC Enforcement Policy (10 CFR Part 2, Appendix C).

LI.

Technical = Specification l6.8.1 requires that written procedures be estab-3' '.

lished, implemented and maintained to control' safety-related activities.

Annunciator Response Procedure 1-AR-3 specifies the necessary actions to 1 respond to panel.1C main control' board-annunciator A-8 (charging ' Pump 18 g

215J6 lockout).

);

't

- North Anna Power Station Administrative Procedure (ADM 19.3), " Shift Conduct" ' outlines the minimum turnover to be performed by ' the shift supervisor ~and control room operator.

x-S' Contrary to :the above, during the December 4 timeframe, the annunciator.

response -procedure and -shift turnover' procedure were not followed when the: alarm was ~ received, resulting in the continued lockout of IB charging pump; thus. reducing to 'one the number of operable. charging pumps for. the unit.

This is a Severity Level IV violation and applies to North Anna Unit.1.

2.

North Anna: Power Station,- Unit 2 Facility Operating License NPF-7, dated

-August 21, 1980, condition 2.c.(5) requires, '" Prior to operating the facility ~at a power level-above 25 percent, VEPC0 shall develop 'a surveil-'

tlance. program for fiberglass spray. pond piping and suppor.ts that is in -

~

compli.ance with the regulatory position in Revision 2 of Regulatory

. Guide.1.72,'or an alternative position acceptable to the Commission."

The? regulatory position-in Revision 2 of Regulatory Guide 1.72 specifies

a - yearly ' inspection. frequency for fiberglass piping without an exterior weather resistant coating.

Contrary to the above, the North Anna spray pond piping, which does not have a 'special weather-resistant coating, was being inspected on a frequency less than annual.

This is a Severity level IV violation and applies to North Anna Unit 2.

p-mu mg.

v-

~

~

?, ;

, Virginia Electric & Power Company

-2 Docket Nos. 50 338 and 50-339

. North Anna License Nos. NPF-4 and NPF-7 Pursuant to,10'CFR 2.201, -you are required to submit to this' office within 30 1 days of. the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial -of the alleged violations; (2) the reasons

. for the-violations' if admitted;- (3) the corrective steps which have been taken.

and the results achieved; (4) corrective - steps which will be taken to avoid further' violations; and (5) the date when full compliance will be achieved.

- Security or Jsafeguards information should be submitted as an enclosure to facilitate withholding it,from public disclosu're as required by 10 CFR 2.790(d) or 10-CFR-73.21.