ML20127J603

From kanterella
Jump to navigation Jump to search
Ack Receipt of 850312 Ltr Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-338/84-44 & 50-339/84-44.Violation Re Piping W/O Weather Resistant Coating Still Valid
Date released: 05/20/2020 Download: ML20127J603


Insp Repts 50-338/84-44 & 50-339/84-44 on 841206-850105. Violation Noted:Svc Water Arrays Piping Lacked weather-resistant Coating & Failure to Perform Proper Shift Turnovers Re Annunciator Status
ML20127J670
Person / Time
Site: North Anna 
Issue date: 02/07/1985
From: Branch M, Elrod S, Luehman J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20127J670 (9)
Notice of Violation from Insp on 841206-850105
ML20127J653
Person / Time
Site: North Anna 
Issue date: 02/11/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20127J653 (2)
Forwards Insp Repts 50-338/84-44 & 50-339/84-44 on 841206-850105 & Notice of Violation
ML20127J640
Person / Time
Site: North Anna 
Issue date: 02/11/1985
From: Walker R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: STEWART W L
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
Download: ML20127J640 (2)
Responds to NRC 850211 Ltr Re Violations Noted in Insp Repts 50-338/84-44 & 50-339/84-44.Corrective Actions:Charging Pump B Restored to Standby Condition by Clearing Lockout & Personnel Reinstructed in Responsibilities
ML20127J625
Person / Time
Site: North Anna 
Issue date: 03/12/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: GRACE N J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20127J625 (5)
Ack Receipt of 850312 Ltr Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-338/84-44 & 50-339/84-44.Violation Re Piping W/O Weather Resistant Coating Still Valid
ML20127J600
Person / Time
Site: North Anna 
Issue date: 04/08/1985
From: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: STEWART W L
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
Download: ML20127J600 (1)