1

,f^

i 4,

PAUL SCHERRER INSTITUT E5E Document No.

ALPHA-618 Document Title PANDA Transient Tests M2 Integral System Test Data Transmittal Report Revision Status Approval / Date Rev.

Prepared / Revised by P-PM G-PM G SOR issue Date Remarks J. Torbeck G. Wingate 2 July 96

$<N $

0 M. Huggenberger ik

(,

7 qt h 1 July 96 1 July 96

p. gay.g, p l

i t

al 609. doc /07 0719%

9608200169 960816 PDR ADOCK 05200004

\\

A PDR V

V 1

ALPHA-618 / Saite 2 l

Controlled Copy (CC) Distribution List Note: Standard distribution (cf. next page) is non-controlled 1

CC Holder CC List Entry Return / Recall No.

Name, Affiliation Date Date i

e

y ee ee Repstriersng C

12 PAUL SCHERRER INSTITUT 42-96-21 ALPHA-618-0 PANDA Transient Tests Ersea TRel M2 Integral System Test Data Transmittal Report Erstem Autoren/

M. Huggenberger, C. Aubert, J. Dreier, O. Fischer, Autorinnen S. Lomperski, H.J. Strassberger

28. June 1996 Summary:

This Data Transmittal Report (DTR) summarizes the results of the PANDA transient system test M2 which is a simulation of an SBWR main steam line break at one hour into the LOCA.

The 20 hour2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> test was conducted with the same nominal initial conditions as for the base case test M3. Test M3 had a symmetrical steam flow from the RPV to the two drywells, whereas in test M2 all the steam was directed to drywell 2. This is to create asymmetric distnbution of steam and non-condensable gas concentration and to demonstrate the PCCS performance under these conditions.

The DTR for test M2 together with the Umbrella DTR satisfies the requirements specified in the Test Plan (TP) 25A5785 Rev 0 (GE document) section 10. The DTR includes: General description and purpose of test, test facility configuration description and a table of actual and specified initial conditions. Further, the test results are presented by time history plots over the test duration and the main observations are given.

Test M2 has shown a favorable and robust overall PCC system performance. The asymmetric distribution of steam and noncondensable gas concentration did not neghtively affect overall system behaviour. The DW/WW pressure response was practically the same as for the base case test M3. No vacuum breaker opening occurred during the test and the PCCs shared load among themselves as needed.

The M2 test objectives have been achieved.

l Veneder Abt.

Empfinger/ Ernpfingennnen Expt Abt.

Empfanger/ Empfingennnen Expi.

Expt 42 G. Yadigaroglu 1

GE San Jose CA Bdiothek G. Varadi 1

J.E. Torbeck 1

C. Aubert 1

(for distribution at GE to Peserve 5

T. Bandurski 1

J.R. Fitch, G.A. Wingate, J. Dreier 1

B.S. Shiralkar, Total 18 O. Fischer 1

DRF No. T10-0005)

J. Heatzer 1

Senen 55 M. Huggenberger 1

Beilagen S. Lomperski 1

H.J. Strassberger 1

intermenonsns,e PANDA-Documentation 2

Dl1 2l 3l 4 5

8 9

A Vsum AbtAaeorteaun7

ALPHA-618-0 / Page 4 Contents

1. INTRODUCTION 5

1.1 General Description and Purpose of Test 5

1.2 Purpose of Report 5

2. TEST OBJECTIVES 5

i 2.1 General Objectives 5

2.2 Specific Objectives 5

l j

3. TEST FACILITY CONFIGURATION AND INITIAL CONDITIONS 6

q 3.1 Test Facility Configuration 6

3.2 Test initial Conditions 6

4. TEST RESULTS 12 d

4.1 Main Observations 12 4.2 Time History Plots 13

5. CONCLUSIONS 29 5.1 Adequacy of Test Data 29 5.2 Applicability to Test Objectives 29
6. REFERENCE DOCUMENTS 30 APPENDlX: COMPOSITION OF DATA RECORDS 31

ALPHA-618-0 / Page 5

1. Introduction 1.1 General Description and Purpose of Test i

Test M2 is a simulation of a break in the main steam line of the SBWR with asymmetric steam injection into the drywells. The nominal initial containment conditions were the same as for the base case test M3 and equal to those calculated for the SBWR under SSAR assumptions at one hour into the LOCA. The initial drywell pressure was approximately 300 kPa. The steam from the RPV was directed to DW2. DW1 has one PCC condenser and DW2 has two PCC condensers connected. These test conditions represent an asymmetrical situation in the PANDA facility. The test provides data for comparison to the base case test M3, which had symmetrical steam flow to the two drywells.

1.2 Purpose of Report This Data Transmittal Report (DTR) is compiled in accordance with the requirements specified in Test Plan (TP) 25A5785 Rev 0 (GE document) Section 10 (1). The report covers the results for the transient integral system test M2 which has been run in accordance with the test procedure desenbed in [2]. The DTR provides detailed information about test objectives, the test facility configuration and the test initial conditions. The test results main observations are reportei:1 and a number of plots, which support the findings are included. The conclusions about the adequacy of test data and the applicability of test objectives are given. The composition of the data record is j

described in an Appendix. The general information about the overall test program, the PANDA facility, the instrumentation, the data acquisition system, the facility characterization tests, the PANDA experimental data base and the error analysis is described in the,DTR umbrella report (4). The apparent test results for test M2 are summarized in [3].

2. Test Objectives 2.1 General Objectives The objectives of the PANDA integral system tests are to provide additional data to: a) confirm the capability of TRACG to predict SBWR containment system performance, including potential systems interaction effects (Integral System Tests) and b) demonstrate startup and long term operation of a passive containment cooling system (Concept Demonstration).

2.2 Specific Objectives The specific objective of test M2 which was conducted with nominal post-LOCA conditions one hour after a main steam line break, with all steam flow directed through the steam line from RPV to DW2 to create asymmetric distributions of steam and noncondensable gas concentrations, is to demonstrate the PCCS / containment performance under these conditions.

d

ALPHA-618-0 / Page 6

3. Test Facility Configuration and initial Conditions 3.1 Test Facility Configuration The PANDA test facility is described in detail in Section 3 of PSI report ALPHA-606 (4]. For test M2 the PANDA facility was configured to simulate the SBWR post-LOCA configuration as follows:
1) The RPV supplies steam only to drywell 2 through its single connecting steam line.
2) The RPV heater power is controlled as a function of time to simulate the scaled decay heat and stored energy release (as specified in [1]).
3) The IC unit is isolated by closing the inlet and outlet valves (i.e., the IC feed, drain and vent lines are closed).

]

4) All three PCC units are lined-up to take feedflow from the drywells, to vent noncondensables and steam into the water volume of the suppression pool, and drain condensate to the GDCS volume.
5) The three PCC pools are filled and isolated from each other. During the test, no water is added or drained from the pools.
6) The only direct lines of communication between the drywell and wetwell are through the j

vacuum breakers (when the wetwell pressure exceeds drywell pressure sufficiently to open the vacuum breaker) and the main vent lines (which are submerged within the wetwells).

7) The GDCS pressure equalization lines to both drywells are open.
8) The GDCS drain line with check valve is lined up to return PCC condensate to the RPV,
9) The Equalizing lines between the RPV and wetwells are valved out of service.

3.2 Test initial Conditions The test initial conditions represent the state of the system one hour after scram. These j

conditions are presented in Table 3.1. The ' Average Value' represents the arithmetic mean over the one minute measurement period just before connecting the drywells to the RPV. The

" Requested Value' is the value as it is specified in the Test Plan [1].

ALPHA-618-0 / Page 7 Table 3.1: Test M2 initial Conditions VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value ENVIRONMENT PAR AMETERS Atmospheric pressure MP.EN bar Temperature of saturation for atmospheric pressure (T,2,es)

C RPV PARAMETERS Total pressure MP.RP.1 bar Fluid temperatures:

Spatial average Tp,=2n(RP)

C Local MTF.RP.1 C

MTF.RP.2 C

MTF.RP.3 C

MTF.RP.4 C

M17.RP.5 C

Water level ML.RP.1 m

DRYWELL PARAMETERS (UTotal pressure MP.D1 bar

' Air partial pressure MPG.Dl.1 bar MPG.D2.1 bar MPG.D2.2 bar Gas temperatures:

Spatial average Tc_m,2n(D1)

C Local MTG.DI.1 C

MTG.DI.2 C

MTG.DI.3 C

MTG.DI.4 C

MTG.D I.5 C

MTG.DI.6 C

Spatial average To,.2n(D2)

C (1) The Drywell total pressures are not indepe idant variables, they are given by temperatures and air partial pressures. The corresponding tolerance is calculated from temperature and gas partial pressure tolerances.

(2) Refer to Test Procedure on how the air partial pressure is adjusted in the DWs (not based on oxygen probe measurements, but on p essure increase during air injection).

ALPHA-618 0 / Page 8 Table 3.1: Test M2 initial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value DRYWELL PARAMETERS (Cont'd)

Local MTG.D2.1 C

MTG.D2.2 C

MTG.D2.3 C

MTG.D2.4 C

MTG.D2.5 C

MTG.D2.6 C

Water level ML.D1 m

ML.D2 m

SUPPRESSION CHAMBER PARANETE Total pressure MP.S1 bar (3} Air partial pressure MPG.51 bar MPG.S2 bar Water temperatures:

Spatial average Tw m...(SI)

C Local MTL.SI.1 C

MTL.S t.2 C

MTL.S t.3 C

MTL.S t.4 C

MTL.S t.5 C

MTL.SI 6 C

Spatial average Tw

.,(S2)

C Local MTL.S2.1 C

MTL.S2.2 C

MTL.52.3 C

MTL.S2.4 C

MR..S2.5 C

MTL.S2.6 C

(3) The Suppression Chamber air partial presswes are not independant variables, they are given by temperatwes and total presswes. The corresponding tolerance is ca:culated from temperatwe and total pressure tolerances.

1 j

ALPHA-618-0 / Page 9 l

i Table 3.1: Test M2 initial Conditions Contd.

l VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value SUPPRESSION CHAMBER PARANETERS (Cont'd)

Gas temperatures:

Spatial average Tc_m.2n(S 1)

C Local MTG.S t.1 C

MTG.S t.2 C

MTG.S t.3 C

MTG.S 1.4 C

MTO.S t.5 C

MTG.S t.6 C

Spatial average Tc_m.in(S2)

C Local MTG.S2.1 C

MTO.S2.2 C

MTG.S2.3 C

M T G.S2.4 C

MTG.S2.5 C

l MTO.S2.6 C

Water level ML.Sl m

ML.S2 m

GDCS PAR AMETERS Total pressure MP.GD bar Fluid temperatures:

Spatial average T _=an(GD)

C F

Local MTF.GD.1 C

MTF.GD.2 C

MTF.GD.3 C

MTF.GD 4 C

MTF.GD.5 C

MTF.GD.6 C

MTF.GD.7 C

Water level ML.GD m

O

  • ALPHA 618-0 / Page 10 4

Table 3.1: Test M2 Initial Conditions Contd.

j VARIABLE PROCESSID ' UNIT Average Standard Requested Tolerance Value Deviation Value l

PCCI POOL PARAMETERS l'

4-Water temperatures:

1 Spatial average -

Tw =2n(Ul)

C j

Local MTL.UI.1 C

MTL.U I.2 C

MTL.U I.3 C

MTL.U I.4 C

MTL.UI.5 C

MTL.UI.6 C

MTL.UI.7 C

Water level ML.U t m

PCC2 POOL PARAMETERS Water temperatures:

Spatial average Tw.2n(U2)

C Local MTL.U2.1 C

MTL U2.2 C

MTL.U2.3 C

MTL U2.4 C

MTL.U2.5 C

MTL.U2.6 C

MTL.U2.7 C

Water level ML.U2 m

ECC3 POOL PARAMETERS Water temperatures:

Spatia 1 average Tw =2n(U3) c Local MTL.U3.1 C

MTL.U3.2 C

j ALPHA-618-0 / Page 11

(

Table 3.1: Test M2 initial Conditions Contd.

i VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviatio-7alue j

1 PCC3 POOL PARAMETERS (Cont'd)

MTL.U3.3 C

MTL.U3.4 C

MTL.U3.5 C

MTL.U3.6 C

MTL.U3.7 C

MTL.U3.8 C

MTL.U3.9 C

MTL.U3.10 C

MTL.U3.11 C

i MTL.U3.12 C

MTL.U3.13 C

MH..U3.14 C

MTL.U3.15 C

I MTL.U3.16 C

MTL.U3.17 C

MTL.U3.18 C

MTL.U3.19 C

l Water level ML.U3 m

List of Deviations from Requested Ir*WI cantiltions:

Air partial pressure in Drywe!! 2 This minor deviation did not affect the test results (see also footnote (2) on page 7)

ALPHA-618-0 / Page 12

4. Test Results The main observations for test M2 with asymmetric distnbution of steam and noncondensable gas concentrations are presented in Section 4.1. A standerd set of time history plots for the key parameters and additional plots which support the individual test observations are given in Section 4.2.

4.1 Main Observations l

}

l 4

ALPHA-618-0 / Page 13 4

4

\\

i i

h 4

1 1

i l

1 J

l k

l i

t i

[

i Time history plots are provided to support the observations discussed in Section 4.1 for the following parameters:

Figure 2

RPV, Drywell and Wetwell Pressures 1

4 PCC Feed Mass Flow Rates 2

f PCC1 Temperatures 3

i PCC2 Temperatures 4

l-PCC3 Temperatures 5

PCC Vent Phase Detectors 6

~ PCC Vent Line Gas Temperatures 7

Drywell Air Partial Pressures 8

Wetwell Air Partial Pressures 9

.._.. _..... ~. - - -.-

1 i

ALPHA-618-0 / Page 14 Figure i

PCC Pool Levels 10 J

l RPV Heater Power 11 i

i RPV and Drywell Temperatures 12 l

1 Wetwell Gas and Water Temperatures 13 Main Steam Line 2 Mass Flow Rate 14

?

The identification code for the process variables used in the plots is explained in the DTR Umbrella Report, Section 4 (4]. Also, the DAS channel, type, range, accuracy and location of q

each instrument are given in the Appendix ' Composition of Data Records".

l i

4 4

1-i 1

i i

i i

4

't e

i 4

9 8

e J

i 4

i 1

1 I

i t-l l

4-

)

1 1

i

~.

i.

ALPHA-618-0 / Pages 15 through 28 l

f 4

f 1

These pages have been deleted from this nonproprietary version of this report, because Figures I through 14 which are on these pages in the proprietary version of the report j

contain proprietary information.

I l

k l

1 i

4 I

I

1

'~

ALPHA-618-0 / Page 29

5. Conclusions 5.1 Adequacy of Test Data The integral system test M2 has provided data of the overall system behaviour in an adequate manner. Based on the analysis of the test data [3] the test acceptance criteria have clearly been reached. All zero and instrument checks for test M2 have been successfully completed and the instrument readings were within the permitted ranges.

1 5.2 Applicability to Test Objectives The test objectives as stated in Section 2 of this report have been reached:

  • A favorable and robust overall PCC system performance has been demonstrated.
  • The asymmetric distribution of steam and noncondensable gas concentration did not negatively affect the system performance.

)

  • The asymmetric test M2 showed generally the same globel system behaviour as the symmetric base case test M3 did.
  • The DW air partial pressure decreased to a non-measurable value after approximately 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> j

in DW2 and after about 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> in DW1.

l

  • The PCC system removed all decay heat, no energy addition to the suppression pool occurred over the duration of the test.

1

?

}

)

i l

i 1

4

ALPHA-618-0 / Page 30

6. Reference Documents

[1]

" PANDA Test Plan-Tests M2, M10A, M10B' (Specification), GE Document 25A5785 Rev. O, Nov 21,1995.

[2]

  • PANDA Transient Tests, M2, M10A & M10B Integral System Test Procedure", PSI Internal j

Report ALPHA-527-0, Nov 21,1995.

]

4

[3]

' PANDA Transient Tests, M2 Integral System Test Apparent Test Results", PSI Internal j

Report ALPHA-608-0, April 25,1996, Proprietaryinformation.

[4]

" PANDA Facility, Test Program and Data Base General Description (DTR Umbrella Report) ",

PSI Internal Report ALPHA-606-0, May 31,1996.

[5]

'SBWR Test and Analysis Program Description" (TAPD, Licensing Topical Report), GE Report NEDC-32391P Rev. C, August 1995, GE ProprietaryInformation.

i

ALPHA-618-0 / Page 31 Appendix: Composition of Data Records Data Transfer for PANDA Test M2 All variables given by the Table A.1 are contained in four ORACLE tables:

G E_PAND A_M2_MT_LINE 38621 rows GE PANDA _M2_MT_ POOL 38621 rows GE_ PANDA _M2_MT_ VESSEL 38621 rows GE_ PANDA _M2_M_OTHER 38621 rows All contain the variable called REC _ID (record identifier) allowing to link records to corresponding time.

Time data are given in the table:

GE_ PANDA _M2_M_ TIME 38621 rows The structure of all these tables is exactly the same as the one described in the DTR umbrella report [4] for corresponding tables labeled without "G E_'

(PANDA _M2_...

instead of GE_ PANDA _M2...); new table names have been used because of database consistencyl All these tables are owned by the user "aubert" and have been created in the tablespace

' USERS'; they have been exported in file "M2_GE_ tables.dmp".

Measurements with restricted use MV.P3C only qualitative use possible (for example oscillations etc.) absolute value is not reliable MV.GRT only qualitative use possible (for example oscillations etc.) absolute value is not reliable MV.P1V MV.P2V during whole test below lower flow limit MV.P3V MV.P2F below lower flow limit (cf. Figure 2)

ALPHA-618-0 / Page 32 Table A.1: M2 Data Identification DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 230 CB.VB1 KEY.NOR.AUT 0,50 or 100%

On/Off valve Vacuum Breaker SC1-DW1 231 CB.VB2 KEY.NOR.AUT 0,50 or 100%

On/Off valve Vacuum Breaker SC2-DW2 105 MD.GRT RM 1151 DPS

-36.- 150. kPa 1.68 kPa pressure diff. meas. Condensate Return GDCS->RPV 530 MD.MS1 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW1 531 MD.MS2 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW2 98 MD.MV1 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW1->SC1 99 MD.MV2 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW2->SC2 537 MD.P1 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC1 Condenser 540 MD.P1C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCCI Condensate PCC1->GDCS 533 MD.P1F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff, meas. PCC1 Feed DW1->PCCI 544 MD.P1 V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC1 Vent PCCI->SC1 101 MD.P1V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC1 Vent PCC1->SC1 538 MD.P2 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC2 Condenser 541 MD.P2C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC2 Condensate PCC2->GDCS 534 MD.P2F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC2 Feed DW2->PCC2 545 MD.P2V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 102 MD.P2V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 539 MD.P3 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC3 Condenser 542 MD.P3C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC3 Condensate PCC3->GDCS 535 MD.P3F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC3 Feed DW2->PCC3 546 MD.P3V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC3 Vent PCC3->SC2 103 MD.P3V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC3 Vent PCC3->SC2

r l

ALPHA-618-0 / Page 33 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 224 MD.VB1 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC1-DW1 225 MD.VB2 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC2-DW2 36 ME.RP EH MYCOM 0 - 200 pS/cm 0.5 %

water quahty meas. Reactor Pressure Vessel / RPV 70 MI.MV1 PSI /GA COND 0 or 1 phase indicator Main Vent line DW1->SC1 71 MI.MV2 PSI /GA COND 0 or 1 phase indicator Main Vent line DW2->SC2 67 MI.P1V.1 PSI /GA COND 0 or 1 phase indicator PCC1 Vent PCC1->SC1 68 MI.P2V.1 PSI /GA COND 0 or 1 phase indicator PCC2 Vent PCC2->SC2 69 MI.P3V.1 PSI /GA COND 0 or 1 phase indicator PCC3 Vent PCC3->SC2 227 MLD1 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 1/ DW1 228 MLD2 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 2 / DW2 229 ML.GD RM 3051 CD3 0-6.3 m 0.070 m level meas. GDCS tank / GDCS 113 ML.MS1 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW1 114 ML.MS2 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW2 8

ML.RP.1 RM 3051 CD3 0-21.5m 0.166 m level meas. Reactor Pressure Vessel / RPV 9

ML.RP.2 RM 1151 DP5 0-4.1 m 0.157 m level meas. Reactor Pressure Vessel / RPV 107 ML.RP.3 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 108 MLRP.4 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 226 ML.RP.5 RM 1151 DPS 0-7.7 m 0.166 m level meas. Reactor Pressure Vessel / RPV 360 ML.RP.6 RM 1151 DP5 0-4.6 m 0.158 m level meas. Reactor Pressure Vessel / RPV 110 ML.S1 RM 3051 CD2 0 -4.6 m 0.039 m level meas. Suppression Chamber 1/ SC1 111 ML.S2 RM 3051 CD2 0-4.6 m 0.039 m level meas. Duppression Chamber 2 / SC2 547 ML.00 RM 1151 DP5 0-5.6 m 0.156 m level meas. IC pool

ALPHA-618-0 / Page 34 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 548 ML.U1 RM 1151 DPS 0-5.6 m 0.156 m level meas. PCCI pool 549 ML.U2 RM 1151 DP5 0-5.6 m 0.156 m level meas. PCC2 pool 550 ML.U3 RM 1151 DP5 0-5.6 m 0.156 m level meas. PCC3 pool 72 MO.VB 0 or 1 Vacuum Breaker Trigger signal 555 MP.D1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Drywell 1/ DW1 556 MP.D2 RM 1144 A 0.0- 6.0 bar 0.172 bar absol. pressure meas. Drywell 2 / DW2 2

MP.EN RM 3051 CA2 0.0- 1.5 bar 0.011 bar absol. pressure meas. Environment 338 MP.GD RM 1144 A 0.0- 6.0 bar 0.160 bar absol. pressure meas. GDCS tank / GDCS 218 MP.MS1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW1 219 MP.MS2 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam lint '.PV->DW2 344 MP.P1F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Feed DW1->PCC1 341 MP.P1V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Vent PCC1->SC1 557 MP.P2F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Feed DW2->PCC2 342 MP.P2V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Vent PCC2->SC2 558 MP.P3F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Feed DW2->PCC3 343 MP.P3V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Vent PCC3->SC2 554 MP.RP.1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Reactor Pressure Vessel / RPV 58 MP.RP.2 RM 2088 A3 0.0-13.0 bar 0.293 bar absol pressure meas. Reactor Pressure Vessel / RPV 221 MP.S1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Suppression Chamber 1/ SC1 222 MP.S2 RM 1144 A -

0.0- 6.0 bar 0.169 bar absol. pressure meas. Suppression Chamber 2 / SC2 435 MPG.D1.1 LI1231 O2

.002-600 bar 4.0*i air partial press. meas. Drywell 1/ DW1 439 MPG.D2.1 LI1231 02

.002-600 bar 4.0 %

air partial press. meas. Drywell 2 / DW2

ALPHA-618-0 / Page 35 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 441 MPG.D2.2 LI 123102

.002-600 bar 4.0 %

air partial press. meas. Drywell 2 / DW2 375 MPG.S1 Ll 123102

.002-600 bar 4.0 %

air partial press. meas. Suppression Chamber 1/ SC1 377 MPG.S2 LI 123102

.002-600 bar 4.0 %

air partial press. meas. Suppression Chamber 2 / SC2 482 MTF.GD.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 480 MTF.GD.2 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 479 MTF.GD.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 478 MTF.GD.4 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 477 MTF.GD.5 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 476 MTF.GD.6 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 475 MTF.GD.7 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 336-MTF.RP.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 335 MTF.RP.2 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 334 MTF.RP.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 96 MTF.RP.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 95 MTF.RP.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV I

474 MTG.D1.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 473 MTG.D1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DWl 472 MTG.D t.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 471 MTG.D1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 l

470 MTG.D1.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 469 MTG.D1.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 467 MTG.D2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2

a 4

ALPHA-618-0 / Page 36 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 466 MTG.D2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 465 MTG.D2.3 PSITC

' 1.0-196.58 C

. 0.8 C gas temp. meas. Drywell 2 / DW2 464 MTG.D2 4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 463 MTG.D2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 l

462 MTG.D2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2

?

717 MTG.GP1.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Fressure equal. GDCS-DW1 r

716 MTG.GP1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 715 MTG.GP2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 714 MTG.GP2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 713 MTG.11.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 712 MTG.11.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser f

711 MTG.11.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser f

710 MTG.11.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 709 MTG.II.5 PSITC

.1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 708 MTG.11.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser l

I 707 MTG.11.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser l

706 MTG.11.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser

{

4 705 MTG.11.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser l

571 MTG.11F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. IC Feed RPV->lC 459 MTG.11 F.2 PSI TC

- 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 704 MTG.11 F.3 PSI TC 1.0-196.58 C 0.8 'C gas temp. nieas. IC Feed RPV->lC f

237 MTG.MSI.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas.. Main Steam line RPV->DWI

- =.----

- -.-.a.-

- -------.---.n

. l A

ALPHA-618-0 / Page 37 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 458 MTG.MS t.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line HPV->DW1 456 MTG.MS1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 238 MTG.MS2.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW2 455 MTG.MS2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2 454 MTG.MS2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam !ine RPV->DW2 287 MTG.MV1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 333 MTG.MV1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 216 MTG.MV1.3 PSITC 1.0-196.58 C O.8 C gas temp. meas. Main Vent line DW1->SC1 215 MTG.MV1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 286 MTG.MV2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 332' MTG.MV2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 214 MTG.MV2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 213 MTG.MV2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 703 MTG.P1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 702 MTG.P1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 701 MTG.P1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 700 MTG.P1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 699 MTG.P 1.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 698 MTG.P1.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 696 M1 G.P1.7 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 695 MTG.P1.8 PSITC 1.0-196.58 C 0.8 C' gas temp. meas. PCC1 Condenser 694 MTG.P1.9 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser

ALPHA-618-0 / Page 38 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 572 MTG.P1 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC1 Feed DW1->PCC1 693 MTG.P1 F.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Feed DW1->PCC1 365 MTG.P1V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC1 Vent PCC1->SC1 692 MTG.P1V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 331 MTG.P1V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 212 MTG.P1V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 211 MTG.P1V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1-> SCI 691 MTG.P2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 690 MTG.P2.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 689 MTG.P2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 688 MTG.P2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 687 MTG.P2.5 PSITC 1.0-196.58 C 0.8 C gas temo. meas. PCC2 Condenser 686 MTG.P2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 685 MTG.P2.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 684 MTG.P2.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 683 MTG.P2.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 573 MTG.P2F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC2 Feed DW2->PCC2 682 MTG.P2F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Feed DW2->PCC2 366 MTG.P2V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC2 Vent PCC2->SC2 681 MTG.P2V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 330 MTG.P2V.3 PSITC 1.0-196.58 C 0.8 C gas temp. mbas. PCC2 Vent PCC2->SC2 210 MTG.P2V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2

ALPHA-618-0 / Page 39 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 209 MTG.P2V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 528 MTG.P3.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 527 MTG.P3.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 526 MTG.P3.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 525 MTG.P3.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 524 MTG.P3.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 523 MTG.P3.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 522 MTG.P3.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 521 MTG.P3.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 520 MTG.P3.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser i

i 574 MTG.P3F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC3 Feed DW2->PCC3 680 MTG.P3F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Feed DW2->PCC3 367 MTG.P3V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC3 Vent PCC3->SC2 679 MTG.P3V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 329 MTG.P3V.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 208 MTG.P3V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 207 MTG.P3V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 206 MTG.SI.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 l

205 MTG.S t.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 204 MTG.S1.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 203 MTG.SI.4 PSI TC 1.0-196.58 C 0.8 C' gas temp. m'eas. Suppression Chamber 1/ SCI 202 MTG.S t.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1

ALPHA-618-0 / Page 40 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 201 MTG.SI.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 199 MTG.S2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 198 MTG.S2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 197 MTG.S2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 196 MTG.S2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 195 MTG.S2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 194 MTG.S2.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 449 MTG.TDO.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 448 MTG.TDO.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 447 MTG.TDO.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 328 MTG.TSU.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 327 MTG.TSU.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 326 MTG.TSU.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 325 MTG.VB1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 324 MTG.VB1.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 446 MTG.VB1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 445 MTG.VB1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 323 MTG.VB2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 322 MTG.VB2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 444 MTG.VB2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 443 MTG.VB2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 283 MTI.D1.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1

b ALPHA-618-0 / Page 41 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 282 MTI.DI.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 281 MTI.D1.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 280 MTI.D1.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 279 MTI.D1.5 PSITC 1.0-196.58 C 0.8 C inside wall temp meas. Drywell 1/ DW1

(

278 MTI.D1.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. mess. Drywell 1/ DW1 277 MTI.D1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 276 MTI.D 1.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Dryweil 1/ DW1 275 MTI.D1.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 274 MTI.D2.1 PSI TC 1.0-196.58 C O.8 C inside wall temp. meas. Drywell 2 / DW2 273 MTI.D2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 272 MTI.D2.3 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 271 MTI.D2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 270 MTI.D2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 269 MTI.D2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 268 MTI.D2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 267 MTI.D2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 266 MTI.D2.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 263 MTI.GD.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 262 MTI.GD.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 261 MTI.GD.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 260 MTI.GD.4 PSITC 1.0-196.58 C 0.8 C inside wall t'emp. meas. GDCS tank / GDCS 259 M TI.G D.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS

ALPHA-618-0 / Page 42 Table A.1: M2 Data identification contd.

DACHANNEL PROCESS 10 TYPE RANGE / UNIT ACCURACY LOCATION 258 MTI.GD.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 244 MTI.RP.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 243 MTl.RP.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 242 MTI.RP.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 191 MTI.S1.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 190 MTI.S1.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 189 MTI.S1.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 188 MTI.S t.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 187 MTI.S1.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 186 MTI.S1.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 185 MTI.S1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 184 MTI.SI.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 183 MTI.S1.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 182 MTI.S2.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 181 MTI.S2.2 PSI TC 1.0-196.58 C O.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 180 MTI.S2.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 179 MTI.S2.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 178 MTI.S2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 177 MTI.S2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 176 MTI.S2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 175 MTI.S2.8 PSI TC 1.0-196.58 C 0.8 C inside wall te'mp. meas. Suppression Chamber 2 / SC2 174 MTI.S2.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2

- -. -,. -.. =.. ~ -.~. ~

..~

. --._ ~.

~

ALPHA-618-0 / Page 43 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 14 MTL.EOO HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. EOualization line common branch 15 MTL.GRT.1 HB Pt100 0.0-200.00 C 0.2 C liquid temp. meas. Condensate Return GDCS->RPV 88 MTL.GRT.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Return GDCS->RPV 317 MTLGRT.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Return GDCS->RPV 674 MTLl1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condenser 16 MTLl1C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. IC Condensate IC->RPV 672 MTL.11 C.2 PElTC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV 173 MTLl1C.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV 671 MTL.P1 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condenser i

234 MTL.PI C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 670 MTL.P1C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 669 MTL.P2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condenser 235 MTL.P2C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 668 MTL.P2C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 519 MTL.P3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condenser 236 MTL.P3C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC3 Condensate PCC3->GDCS l

667 MTL.P3C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 86 MTL.RP.1 PSITC 1.0-196.58 C O.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 85 MTL.RP.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 172 MTL.S t.1 PSITC -

1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SCI 171 MTL.SI.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 170 MTL.S1.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1

-i u

+

+

e+we-

ALPHA-618-0 / Page 44 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 168 MTL.S t.4 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 167 MTL.S t.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 166 MTL.S t.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 165 MTL.S2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 164 MTL.S2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 163 MTL.S2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 162 MTL.S2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 161 MTL.S2.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 160 MTL.S2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 1

159-MTL.TSL.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 158 MTL.TSL.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 157 MTL.TSL.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 432 MTL.UO.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 431 MTL.UO.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 430 MTL.UO.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 429' MTL.UO.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 428 MTLUO.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 427 MTLUO.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 426 MTL.UO.7 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 657 MTL.U1.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 656 MTL.U 1.2 PSITC 1.0-196.58 C 0.8 C liquid temp.* meas. PCC1 pool 655 MTL.U 1.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool

m.

4 ALPHA-618-0 / Page 45 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 654 MTL.U1.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 653 MTL.U1.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 652 MTL.UI.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 651 MTL.U1.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 647 MTLU2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 646 MTL.U2.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 645 MTL.U2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 644 MTL.U2.4 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 643 MTLU2.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 642 MTL.U2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 641 MTL.U2.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 518 MTL.U3.1 PSI ~C 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 517 MTL.U3.2 PS' I'C 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 516 MTL.U3.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 515 MTL.U3.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 514 MTL.U3.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 513 MTL.U3.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 512 MTL.U3.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 511 MTL.U3.8 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 510 MTL.U3.9 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 509 MTL.U3.10 PSITC 1.0-196.58 C 0.8 'C liquid temp'. meas. PCC3 pool -

508 MTL.U3.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool

ALPHA-618-0 / Page 46 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 507 MTL.U3.12 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 506 MTL.U3.13 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 504 MTL.U3.14 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 503 MTL.U3.15 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 502 MTL.U3.16 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 501 MTL.U3.17 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 500 MTL.U3.18 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 499 MTL.U3.19 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 636 MTO.D1.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 635 MTO.D1.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 634 MTO.D1.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 254 MTO.D1.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 253 MTO.D1.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 252 MTO.D1.6 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 315 MTO.DI.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 314 MTO.D1.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 312 MTO.D1.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 633 MTO.D2.1 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 632 MTO.D2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 631 MTO.D2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell _ / DW2 257 MTO.D2A PSI TC 1.0-196.58 C 0.8 C outside wall t'emp. meas. Drywell 2 / DW2 256 MTO.D2.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2

ALPHA-618-0 / Page 47 Table A.1: M2 Data identification contd.

DACHANNEL PFIOCESSID TYPE RANGE / UNIT ACCURACY LOCATION 255 MTO.D2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 311 MTO.D2.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 310 MTO.D2.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 309 MTO.D2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 251 MTO.GD.1 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 250 MTO.GD.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 249 MTO.GD.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 248 MTO.GD.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 247 MTO.GD.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 246 MTO.GD.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 308 MTO.S1.1 -

PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 307 MTO.S1.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 306 MTO.S t.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 156 MTO.S t.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 155 MTO.St.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 154 MTO.SI.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 80 MTO.S t.7 PSITC 1.0-196.58 C 0.8 C outside wall temr,. meas. Suppression Chamber 1/ SC1 79 MTO.S1.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 78 MTO.S1.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 305 MTO.S2.1 PSITC -

1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 304 MTO.S2.2 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 303 MTO.S2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2

ALPHA-618-0 / Page 48 Table A.1: M2 Data identification contd.

DACHANNEL PROCESS:D TYPE RANGE / UNIT ACCURACY LOCATION 153 MTO.S2.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 152 MTO.S2.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 151 MTO.S2.6 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 77 MTO.S2.7 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 76 MTO.S2.8 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 75 MTO.S2.9 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 434 MTP.D1.1 LITC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 1/ DW1 438 MTP.D2.1 Li TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 2 / DW2 440 MTP.D2.2 Li TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 2 / DW2 374 MTP.S1 L1 TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Suppression Chamber 1/ SC1 376 MTP.S2 LI TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Suppression Chamber 2 / SC2 408 MTS.D1.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 407 MTS.D1.2 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 406 MTS.D1.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 405 MTS.D2.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 404 MTS.D2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 403 MTS.D2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 402 MTS.GD.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 401 MTS.GD.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 400 MTS.GD.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 150 MTS.S t.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 149 MTS.S1.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 5

m.

...m.

m.

m -

ALPHA-618-0 / Page 49 Table A.1: M2 Data identification contd.

DACHANNEL PROCESEID TYPE RANGE / UNIT ACCURACY LOCATION 148 MTS.S t.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 147 MTS.S2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 146 MTS.S2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 144 MTS.S2.3 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 425 MTT.11.1 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Co.edenser 424 MTT.11.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 423 MTT.11.3 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 422 MTT.11.4 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 421 MTT.it.5 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 420 MTT.11.6 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 419 MTT.11.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 418 MTT.11.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 417 MTT.11.9 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 416 MTT.11.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 415 MTT.11.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 414 MTT.11.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 413 MTT.11.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 412 MTT.11.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 411 MIT.11.t 5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 410 MTT.11.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 613 MTT.P1.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 612 MIT.P 1.2 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser

ALPHA-618-0 / Page 50 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 611 MTT.P1.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 610 MTT.P1.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 609 MTT.P1.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 608 MTT.P1.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 607 MTT.P1.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 606 MTT.P1.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 605 MTT.P1.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 604 MTT.P1.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 603 MIT.P1.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 602 MTT.P1.12 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 600 MTT.P1.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 599 MTT.P1.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCCI Condenser 598 MIT.P1.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 597 MTT.P1.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 630 MTT.P2.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 629 MTT.P2.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 628 MTT.P2.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 627 MTT.P2.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 626 MTT.P2.5 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 624 MTT.P2.6 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 623 MTT.P2.7 PSI TC 1.0-196.58 C O.8 C tube wall terrip. meas. PCC2 Condenser 622 MTT.P2.8 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser

.m o

ALPHA-618-0 / Page 51 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 621 MTT.P2.9 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 620 MTT.P2.10 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 619 MTT.P2.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 618 MTT.P2.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 617 MTT.P2.13 PSITC 1.0-196.58 C O.8 C tube wall temp. meas. PCC2 Condenser 616 MTT.P2.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 615 MTT.P2.15 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 614 MTT.P2.16 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 498 MTT.P3.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 497 MTT.P3.2 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 496 MTT.P3.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 495 MTT.P3.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 494 MIT.P3.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 493 MTT.P3.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 492 MTT.P3.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 491 MTT.P3.8 PSITC 1.0-1%.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 490 MTT.P3.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 489 MTT.P3.10 PSITC 1.0-196.58 C 0RC sube wall temp. meas. PCC3 Condenser 488 MIT.P3.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 487 MTT.P3.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 486 MIT.P3.13 PSITC 1.0-196.58 C 0.8 C tube wall terhp. meas. PCC3 Condenser 485 MTT.P3.14 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser

?

r ALPHA-618-0 / Page 52 Table A.1: M2 Data identificdon contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 484 MTT.P3.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 483 MTT.P3.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 569 MTV.GP1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 S68 MTV.GP1.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 567

itTV.GP2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 566 MTV.GP2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 302 MTV.GRT PSITC 1.0-196.58 C 0.8 C wall temp. meas. Condensate Return GDCS->RPV 596 MTV.11C PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Condensate IC->RPV 594 MTV.11 F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 399 MTV.11 F.2 PSITC 1.0-196.58 C C.8 C wck Wnp. meas. IC Feed RPV->lC 595 MTV.11 F.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 397 MTV.MSI.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 398 MTV.MS t.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 396 MTV.MSI.3 PSI
  • 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DWt 394 MTV.MS2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Mai:: Steam line RPV->DW2 395 MTV.MS2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 393 MTV.MS2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 292 MTV.MV1.1

' PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 301 MTV.F PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 140 MTV.MV1.3 PSI TC 1.0-196.58 C O.8 C wall temp. meas. Main Vent line DW1->SC1 wall temp. m' as. Main Vent line DW2+SC2 291 MTV.MV2.1 PSITC 1.0-196.58 C 0.8 C e

300 MTV.MV2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2

ALPHA-618-0 / Page 53 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 141 MTV.MV2.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 593 MTV.P1C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Condensate PCC1->GDCS 592 MTV.P1 F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 591 MTV.P1 F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 390 MTV.P1V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCCI->SC1 590 MTV.P1V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 299 MTV.P1V.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCCI Vent PCCI->SC1 137 MTV.P1V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 589 MTV.P2C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Condensate PCC2->GDCS 588 MTV.P2F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 587 MTV.P2F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 389 MTV.P2V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 586 MTV.P2V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 298 MTV.P2V.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 pa MTV.P2V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 bes5 MTV.P3C PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Condensate PCC3->GDCS 584 MTV.P3F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 583 MTV.P3F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 388 MTV.P3V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 582 MTV.P3V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 297 MTV.P3V.3 PSITC 1.0-196.58 C 0.8 C wall temp. m'eas. PCC3 Vent PCC3->SC2 139 MTV.P3V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2

l ALPHA-6*8-0 / Page 54 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION

[

296 MTV.VB1.1 PSITC 1.0-1%.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 f

294 MTV.VB1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 382 MTV.VB1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 384 MTV.VB1.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 295 MTV.VB2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 293 MTV.VB2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 1

379 MTV.VB2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2

{

381 MTV.VB2.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas Vacuum Breaker SC2-DW2 4

I 118 MV.GRT I USON 994 449-2722 g/s 2.0 %

volume flow meas. Condensate Retum GDCS->RPV I

358 MV.MSI I VORTEX 100 135-595 g/s 1.5 %

volume flow meas. Main Steam line RPV->DW1 359 MV.MS2 i VORTEX 100 134-592 g/s 1.5 %

volume flow meas. Main Steam line RPV->DW2 562 MV.P1F i VORTEX 80 72-311 g/s 1.5 %

volume flow meas. PCC1 Feed DW1->PCC1 352 MV.P1V I VORTEX 80 68-262 g/s 2.0 %

volume flow meas. PCC1 Vent PCC1->SC1 j

563 MV.P2F 1 VORTEX 80 73-327 g/s 1.5 %

volume flow meas. PCC2 Feed DW2->PCC2 l

353 MV.P2V 1 VORTEX 80 62-259 g/s 2.0 %

volume flow meas. PCC2 Vent PCC2->SC2 i

116 MV.P3C 1 USON 994 53-387 g/s 2.0 %

volume flow meas. PCC3 Condensate PCC3->GDCS 564 MV.P3F 1 VORTEX 80 71-342 g/s 1.5 %

volume flow meas. PCC3 Feed DW2->PCC3 354 MV.P3V I VORTEX 80 63-263 g/s 2.0 %

volume flow meas. PCC3 Vent PCC3->SC2 42 MW.RP.1 CBSYNEAX 0 - 50 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV l

43 MW.RP.2 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 44 MW.RP.3 CB SYNEAX 0 - 300 kW 0.6 to electrical po' er meas Reactor Pressure Vesse!/ RPV w

45 MW.RP.4 CB SYNEAX 0 - 300 kW 0.6 %.

electrical power meas Reactor Pressure Vessel / RPV i

  • q e.

ALPHA-618-0 / Page 55 Table A.1: M2 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 46 MW.RP.5 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 47 MW.RP.6 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 48 MW.RP.7 HB TZA4 TOT 0 - 1500 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV A Total of 509 Data Records t..

. -