ML20116M442

From kanterella
Jump to navigation Jump to search
Rev 0 to Panda Transient Tests M10B Integral Sys Test Data Transmittal Rept
ML20116M442
Person / Time
Site: 05200004
Issue date: 07/16/1996
From: Huggenberger M, Torbeck J, Wingate G
PAUL SCHERRER INSTITUTE
To:
Shared Package
ML20116M434 List:
References
ALPHA-620, ALPHA-620-R, ALPHA-620-R00, NUDOCS 9608200158
Download: ML20116M442 (43)


Text

l o

PAUL SCHERRER INSTITUT

~

~

E

_B Document No.

ALPHA-620 Document Title PANDA Transient Tests M10B Integral System Test Data Transmittal Report i

Revision Status Approval / Date Rev.

Prepared / Revised by P-PM l

G-PM G-SQ R lssue Date Remarks G

ngate 16 July 96 O

M. Huggenberger

(

J;,To eck r

al.609 doc /t6.07.t996 9608200158 960816 PDR ADOCK 0520 4

  • e J

ALPHA-620 / Saite 2 o,

Controlled Copy (CC) Distribution List Note: Standard distribution (cf. next page) is non-controlled CC Holder CC List Entry Return / Recall No.

Name, Affiliation Date Date

  • M a

i l

1 i

c o Repstnerung EZJzZ PAUL SCHERRER INSTITUT y42 e$0 0

^

g PANDA Transient Tests Ersetzt Titel M10B Integral System Test Data Transmittal Report ErsM Autoren/

M. Huggenberger, C. Aubert, J. Dreier, O. Fischer, l

Autorinnen S. Lomperski, H.J. Strassberger

11. July 1996 Summary:

This Data Transmittal Report (DTR) summarizes the results of the PANDA transient system test M10B which is a simulation of an SBWR main steam line break at one hour into the LOCA. The 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> test was conducted with the same nominal initial conditions as for the base case test M3 and the asymmetric Test M10A. In test M10B all the steam was directed to drywell 1 and only the two PCC condensers connected to drywell 2 were operational. This is to create asymmetric distribution of steam and non-condensable gas concentration. The asymmetric test M10B provides data under these conditions, i.e. maximum non-condensable gas volume purge rate through each PCC.

The DTR for test M108 together witn the Umbrella DTR satisfies the requirements specified in the Test Plan (TP) 25A5785 Rev 0 (GE document) section 10. The DTR includes: General description and purpose of test, test facility configuration description and a taale of actual and specified initial conditions. Further, the test results are presented by time history plots over the test duration and the main observations are given.

Test M10B with asymmetric steam entry into the drywells has demonstrated the non-condensable gas purge from DW1 and DW2 through the two PCCs attached to DW2 to the l

wetwell. No vacuum breaker opening occurred during the test and the two PCCs shared load equally. The main vents cleared periodically for the first hour, because the two PCC condensers were not sufficient to carry the entire load during this period. The air partial pressure decreased similarly in both drywells to a non-measurable value at the end of the test.

The M10B test objectives have been achieved.

Verteiler Abt.

Empfinger / OWp.,,,en Expt Abt.

Empf6nger / Emptingennnen Expl.

Expt 42 G. Yadigatoglu 1

GE San Jose CA Bibliothek G. Varadi 1

1 C. Aubert 1

ution at GE to Reserve 5

T. Bandurski 1

J.R. Fitch, G.A. Wingate, J. Dreier 1

B.S. Shiralkar, bal 3g O. Fischer 1

DRF No. T10-0005)

J. Healzer 1

Seiten 56 M. Huggenberger 1

Beilagen S. Lomperski 1

H.J. Strassberger 1

informationsaste PANDA-Documentation 2

Dl1 2l 3l 4 5

8l 9 A

Visum AbtJLaboriestung:

ALPHA-620-0 / Pago 4 l

I Contents

1. INTRODUCTION 5

i j

1.1 General Description and Purpose of Test 5

1 1.2 Purpose of Report 5

2. TEST OBJECTIVES 5

2.1 General Objectives 5

if 2.2 Specific Objectives 5

3 i

3. TEST FACILITY CONFIGURATION AND INITIAL CONDITIONS 6

i

~

3.1 Test Facility Configuration 6

I 3.2 Test initial Conditions 6

6 i

4. TEST RESULTS 12 4.1 Main Observations 12 4.2 Time History Plots 13
5. CONCLUSIONS 31 5.1 Adequacy of Test Data 31

]

5.2 Applicability to Test Objectives 31

6. REFERENCE DOCUMENTS 32 APPENDlX: COMPOSITION OF DATA RECORDS 33

ALPHA-620-0 / Paga 5 l

1. Introduction 1.1 General Description and Purpose of Test Test M10B is a transient integral systems test with only the two PCC units connected to DW2 operational and all steam flow from the RPV directed to DW1. It is a simulation of a break in the main steam line of the SBWR with asymmetric distribution of steam and non-condensable gas concentration. The nominalinitial containment conditions were the same as for the base case test M3 and equal to those calculated for the SBWR under SSAR assumptions at one hour into the LOCA. The initial drywell pressure was approximately 300 kPa. The test provides data on bounding conditions for non condensable gas transfer from drywell to wetwell with only two of three PCCs operating.

1.2 Purpose of Report This Data Transmittal Report (DTR) is compiled in accordance with the requirements specified in Test Plan (TP) 25A5785 Rev 0 (GE document) Section 10 (1]. The report covers the results for the transient integral system test M10B which has been run in accordance with the test procedure described in [2]. The DTR provides detailed information about test objectives, the test facility configuration and the test initial conditions. The test results main observations are reported and a 1

number of plots, which support the findings are included. The conclusions about the adequacy of test data and the applicability of test objectives are given. The composition of the data record is described in an Appendix. The general information about the overall test program, the PANDA facility, the instrumentation, the data acquisition system, the facility charactenzation tests, the PANDA experimental data base and the error analysis is described in the DTR umbrella report (4]. The apparent test results for test M10B are summarized in [3].

2. Test Objectives 2.1 General Objectives The objectives of the PANDA integral system tests are to provide additional data to: a) confirm the capability of TRACG to predict SBWR containment system performance, including potential systems interaction effects (Integral System Tests) and b) demonstrate startup and long-term 1

operation of a passive containment cooling system (Concept Demonstration).

j i

2.2 Specific Objectives The specific objective of test M10B which was conducted with nominal post-LOCA conditions one hour after a main steam line break, and with only the two PCC condensers connected to drywell 2 operational and all steam flow directed through the steam line from RPV to DW1 is to create asymmetric distributions of steam and non-condensable gas concentrations and demonstrate the PCCS / containment performance under these conditions, i.e. maximum non-condensable gas

i ALPHA-620-0 / Pags 6 volume purge rate through each PCC (total volume of DW1 and DW2 through two PCC condensers).

3. Test Facility Configuration and initial Conditions 3.1 Test Facility Configuration The PANDA test facility is described in detail in Section 3 of PSI report ALPHA-606 [4]. For test M100 the PANDA facility was configured to simulate the SBWR post LOCA configuration as follows:
1) The RPV supplies steam only to drywell 1 through its single connecting steam line.
2) The RPV heater power is controlled as a function of time to simulate the scaled decay heat and stored energy release (as specified in [1]).
3) The IC unit is isolated by closing the inlet and outlet valves (i.e., the IC feed, drain and vent lines are closed).
4) Only the two PCC units connected to drywell 2 are lined-up to take feedflow from the drywells, to vent non-condensables and steam into the water volume of the suppression pool, and drain condensate to the GDCS volume.
5) The three PCC pools are filled and isolated from each other During the test, no water is added or drainec from the pools.
6) The only direct lines of communication between the drywell and wetwell are through the vacuum breakers (when the wetwell pressure exceeds drywell pressure sufficiently to open the vacuum breaker) and the main vent lines (which are submerged within the wetwells).
7) The GDCS pressure equalization lines to both drywells are open.
8) The GDCS drain line with check valve is lineJ up to retum PCC condensate to the RPV.
9) The Equalizing lines between the RPV and wetwells are valved out of service.

3.2 Test initial Conditions The test initial conditions represent the state of the system one hour after scram. These conditions are presented in Table 3.1. The " Average Value" represents the arithmetic mean over the one minute measurement period just before connecting the drywells to the RPV. The

" Requested Value' is the value as it is specified in the Test Plan [1].

m

l..

l..

ALPHA-620-0 / Page 7 l

l Table 3.1: Test M10B initial Conditions 1

l VARIABLE PROCESSID UNIT Average Standard Requested Tolerance i

Value Deviation Value ENVIRONMENT PARANETERS i

Atmospheric pressure MP.EN bar Temperature of saturation for atmospheric pressure (Tsat,g3)

C RPV PARAMETERS i

i Total pressure MP.RP.1 bar Fluid temperatures:

Spatial average Tp mean(RP)

C Local MTF.RP.1 C

MTF.RP.2 C

MTF.RP.3 C

l MTF.RP.4 C

MTF.RP.5 C

l Water level ML.RP.1 m

l DRYWELL PARAMETERS l

  • Total pressure MP.D1 bar Air panial pressure MPG.DI.1 bar l

MPG.D2.1 bar MPG.D2.2 bar l

. Gas temperatures:

l Spatial average Tc mean(DI)

C l

Local MTG.D l.1 C

i MTG.D 1.2 C

MTG.DI.3 C

MTG.DI.4 C

I MTO.D 1.5 C

MTG.DI.6 C

i

  • The Drywell tout pressures are notindefndhnt vanables. they are given by temperatures and aar partial pressures. The corresponding tolerance is calculaiad from temperature and gas partial preuure tolerances.

l

ALPHA-620-0 / Pags 8 Table 3.1: Test M108 Itntial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value DRYWELL PARAMETERS (Cont'd)

Spatial average To,mean(D2)

C Local MTG.D2.1 C

MTG.D2.2 C

MTG.D2.3 C

MTG.D2.4 C

MTG.D2.5 C

MTG.D2.6 C

Water level ML.D1 m

ML.D2 m

SUPPPISSION CHAMBER PARAMETE:

Total pressure MP.S1 bar

" Air partial pressure MPG.S2 bar Water temperatures:

Spatial average Tw.mean(SI)

C Local MTL.S I.1 C

MTL.S I.2 C

MTL.S 1.3 C

MTL.S 1.4 C

MTL.S I.5 C

MTL.S I.6 C

Spatial average Tw mean(S2)

C Local MTL.S2.1 C

MTL.S2.2 C

MTL.S2.3 C

MTL.S2.4 C

MTL.S2.5 C

MTL.S2.6 C

    • The suppression Chamber aar parual pressures are not inccpendant variablEthey are given bWmperatures and total pressures.The correspond-ing it erance is calcularad from temperature and total pressure tolesances.

i ALPHA-620-0 / Page 9 r

j Table 3.1: Test M10B initial Conditions Contd.

I a

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance j

Value Deviation Value SUPPRESSION CHAMBER PARAMETERS (Cont'd) i l

Gas temperatures:

Spatial average Tc_. (SI)

C s'

Local MTG.S t.1 C

t MTG.S t.2 C

MTO.S t.3 C

MTG.S t.4 C

MTG.S I.5 C

MTG.S 1.6 C

Spatial average To_. (S2)

C Local MTG.S2.1 C

MTG.S2.2 C

MTG.S2.3 C

MTG.S2.4 C

MTO.S2.5 C

MTG.S2.6 C

Water level ML.01 m

ML.S2 m

GDCS PARAMETERS Total pressure MP.GD bar Fluid temperatures:

Spatial average Tp_..(GD)

C i

Local MTF.GD.1 C

MTF.GD.2 C

MTF.GD.3 C

MTF.GD.4 C

MTF.GD.5 C

MTF.GD.6 C

MTF.GD.7 C

Water level ML.GD m

ALPHA-620-0 / Page 10 f

i Table 3.1: Test M108 Initial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value l

l l

PCCI POOL PARAMETERS l

I Water temperatures:

Spatial average Tw..n(U1)

C Local MTL.U1.1 C

l MTL.UI.2 C

MTL.UI.3 C

l MTL.U1.4 C

MTL.UI.5 C

i MTL.UI.6 C

MTL.UI.7 C

Water level ML.U1 m

PCC2 POOL PARAMETERS l

Water temperatures:

l Spatial average Tw o(U2)

C l

I l

Local MTL.U2.1 C

MTL.U2.2 C

MTL.U2.3 C

f MTL.U2.4 C

MTL.U2.5 C

MTL.U2.6 C

MTL.U2.7 C

]

Water level ML.U2 m

PCC3 POOL PARAMETERS Water temperatures.

Spatial average Tw..,(U3)

C Local MTL.U3.1 C

MTL.U3.2 C

MTL.U3.3 C

I MTL.U3.4 C

w

l ALPHA-620-0 / Pags 11 I

i l

l Table 3.1: Test M10B Initial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value l

PCC3 POOL PARAMETERS (Cont'd)

MTL.U3.5 C

MTL.U3.6 C

i MTL.U3.7 C

MTL.U3.8 C

M'll..U3.9 C

MTL.U3.10 C

MTL.U3.11 C

MTL.U3.12 C

MTL.U3.13 C

MTL.U3.14 C

I MTL.U3.15 C

M'II..U3.16 C

MTL.U3.17 C

)

MTL.U3.18 C

MTL.U3.19 C

Water level ML.U3 m

i I

List of Deviations from Requested initial Conditions:

Mean Fluid Temperature in GDCS This minor deviation did not affect the test results (cf. [3])

l

. _... -.. _.. ~.. -

4 1

ALPHA-620-0 / Page 12 i

i

4. Test Results f

I 1

The main observations for test M10B with asymmetric steam injection to drywell 1 and only the f

i two PCC units connected to DW2 operational are presented in Section 4.1. A standard set of time

~

history plots for the key parameters and additional plots which support the individual test observations are given in Section 4.2.

e I

4.1 Main Observations i

i t

i 5

l A

i I

i i

f I

l r

l

ALPHA-620-0 / Pags 13 4.2 Time History Plots Time history plots are provided to support the observations discussed in Section 4.1 for the following parameters:

Figure RPV, Drywell and Wetwell Pressures 1

PCC Feed Mass Flow Rates 2

PCC2 Temperatures 3

PCC3 Temperatures 4

PCC Vent Phase Detectors 5

PCC Vent Line Gas Temperatures 6

Drywell Air Partial Pressures 7

Wetwell Air Partial Pressure 8

PCC Pool Levels 9

RPV Heater Power 10 RPV and Drywell Temperatures 11

ALPHA-620-0 / Paga 14 Figure Wetwell 1 Gas and Water Temperatures 12 l

i Wetwell 2 Gas and Water Temperatures 13 Main Steam Line 1 Mass Flow Rate 14 Main Vent Phase Detectors 15 Main Vent Line Gas Temperatures 16 The identification code for the process variables used in the plots is explained in the DTR Umbrella Report, Section 4 [4]. Also, the DAS channel, type, range, accuracy and location of each instrument are given in the Appendix " Composition of Data Records'.

l l

t l

I r

l i

t F

i I

I t

1 ALPHA-620-0 / Pages 15 through 30 1

These pages have been deleted from this nonproprietary version of this report, because Figures 1 through 16 which are on these pages in the proprietary version of the report.

contain proprietary information.

l I

i

)

I i

l I

I l

I l

1

ALPHA-620-0 / Page 31 i

I

5. Conclusions i

5.1 Adequacy of Test Data The integral system test M108 has provided data of the overall system behaviour in an adequate 1

manner. Based on the analysis of the test data [3] the test acceptance criteria have clearly been reached. All zero and instrument checks for test M10B have been successfully completed and the instrument readings were within the permitted ranges.

5.2 Applicability to Test Objectives l

1 The test objectives as stated in Section 2 of this report have been reached:

  • The asymmetric test M10B showed a slightly different system behaviour from the " symmetric" i

base case test M3 and the other asymmetric tests M2 and M10A. The DW/WW pressure continued to slightly increase over the test duration, due to a non-prototypical main vent line heating effect (see below).

  • The two PCC units connected to the system shared load equally.
  • The main vents cleared periodically during the first hour after test initiation because the two PCC units were not sufficient to take the whole load during this period.
  • Because of main vent clearing energy was added to the suppression pool. After the main vent clearing period, there was continuous heat transfer from DW1 to WW1 (due to steam condensation in main vent 1) with corresponding non-prototypical system pressure increase (0.015 bar/hr).
  • The non-condensable gas purge from the drywells to the wetwells, with only two of three PCC units operating, has been successfully demonstrated.

l l

l i

ALPHA-620-0 / Paga 32 1

]

6. Reference Documents

[1]

" PANDA Test Plan Tests M2, M10A, M10B" (Specification), GE Document 25A5785 Rev. O, Nov 21,1995.

[2]

" PANDA Transient Tests: M2, M10A & M108 Integral System Test Procedure", PSI internal Report ALPHA-527-0, Nov 21,1995.

[3]

" PANDA Transient Tests: M10B Integral System Test Apparent Test Results", PSI internal Report ALPHA-611 1, June 12,1996, Proprietaryinformation.

)

[4]

" PANDA Facility, Test Program and Data Base General Description (DTR Umbrella Report) ",

PSI Internal Report ALPHA-606-0, May 31,1996.

[5]

"SBWR Test and Analysis Program Description" (TAPD, Licensing Topical Report), GE Report NEDC-32391 P Rev. C, August 1995, GE Proprietary Information.

l i

\\

i I

l i

l i

i

i ALPHA-S20-0 / Page 33 i

Appendix: Composition of Data Records Data Transfer for PANDA Test M10B All vanables given by the Table A.1 are contained in four ORACLE tables:

GE_ PANDA _M10B_MT_LINE 15134 rows l

GE_ PANDA _M10B_MT_ POOL 15134 rows GE_ PANDA _M10B_MT_ VESSEL 15134 rows GE_ PANDA _M10B_M_OTHER 15134 rows All contain the variable called REC _ID (record identifier) allowing to link records to corresponding time.

Time data are given in the table:

GE_ PANDA _ M10B _M_ TIME 15134 rows The structure of all these tables is exactly the same as the one described in the DTR umbrella report (4] for corresponding tables labeled without "GE_"

(PANDA _M10B_..

instead of GE_ PANDA _M10B...); new table names have been used because of database consistency!

All these tables are owned by the user 'aubert" and have been created in the tablespace

" USERS"; they have been exported in file 'M10B_GE_ tables.dmp".

Measurements with restricted use MV.P3C only qualitative use possible (for example oscillations etc.) absolute value is not reliable MV.GRT only qualitative use possible (for example oscillations etc.) absolute value is not reliable f

during whole test below lower flow limit

ALPHA-620-0 / Page 34 -

Table A.1: M10B Data identification DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 230 CB.VB1 KEY.NOR.AUT 0,50 or 100%

On/Off valve Vacuum Breaker SC1-DW1 231 CB.VB2 KEY.NOR.AUT 0,50 or 100%

On/Off valve Vacuum Breaker SC2-DW2 105 MD.GRT RM 1151 DPS

-36.- 150. kPa 1.68 kPa pressure diff. meas. Condensate Return GDCS->RPV 530 MD.MS1 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW1 531 MD.MS2 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW2 98 MD.MV1 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW1->SC1 99 MD.MV2 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW2->SC2 537 MD.P1 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC1 Condenser 538 MD.P2 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure dif'. meas. PCC2 Condenser 541 MD.P2C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressura diff. meas. PCC2 Condensate PCC2->GDCS 534 MD.P2F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC2 Feed DW2->PCC2 545 MD.P2V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 102 MD.P2V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 539 MD.P3 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC3 Condenser 542 MD.P3C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC3 Condensate PCC3->GDCS 535 MD.P3F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC3 Feed DW2->PCC3 546 MD.P3V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC3 Vent PCC3->SC2 103 MD.P3V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC3 Vent PCC3->SC2 224 MD.VB1 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff, meas. Vacuum Breaker SC1-DW1 225 MD.VB2 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC2-DW2

ALPHA-620-0 / Page 35 Table A.1: M100 Data identificat;on contd.

I DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 36 ME.RP EH MYCOM 0 - 200 pS/cm 0.5 %

water quality meas. Reactor Pressure Vessel / RPV 70 Mt.MV1 PSI /GA COND 0 or 1 phase indicator Main Vent line DW1->SC1 71 Ml.MV2 PSI /GA COND 0 or 1 phase indicator Main Vent line DW2->SC2 67 MI.P1V.1 PSI /GA COND 0 or 1 phase indicator PCC1 Vent PCC1->SC1 68 Mt.P2V.1 PSI /GA COND 0 or 1 phase indicator PCC2 Vent PCC2->SC2 69 Mt.P3V.1 PSI /GA COND 0 or 1 phase indicator PCC3 Vent PCC3->SC2 227 ML.D1 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 1/ DW1 228 ML.D2 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 2 / DW2 229 MLGD RM 3051 CD3 0-6.3 m 0.070 m level meas. GDCS tank / GDCS 113 MLMS1 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW1 114 MLMS2 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW2 8

MLRP.1 RM 3051 CD3 0-21.5m 0.166 m level meas. Reactor Pressure Vessel / RPV 9

ML.RP.2 RM 1151 DPS 0-4.1 m 0.157 m level meas. Reactor Pressure Vessel / RPV 107 MLRP.3 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 108 ML.RP.4 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 226 ML.RP.5 RM 1151 DP5 0-7.7 m 0.166 m level meas. Reactor Pressure Vessel / RPV 360 MLRP.6 RM 1151 DPS 0-4.6 m 0.158 m level meas. Reactor Pressure Vessel / RPV 110 ML.S1 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 1/ SC1 111 ML.S2 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 2 / SC2 547 ML.UO RM 1151 DPS 0-5.6 m 0.156 m level meas. IC pool 548 ML.U1 RM 1151 DPS 0-5.6 m 0.158 m level meas. PCC1 pool 549 ML.U2 RM 1151 DP5 0-5.6 m 0.156 m level meas. PCC2 pool

l ALPHA-620-0 / Page 36 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 550 MLU3 RM 1151 DP5 0-5.6 m 0.156 m level meas. PCC3 pool 0 or 1 Vacuum Breaker Trigger signr' 72 MO.VB 555 MP.D1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Drywell 1/ DW1 556 MP.D2 RM 1144 A 0.0- 6.0 bar 0.172 bar absol. pressure meas. Drywell 2 / DW2 2

MP.EN RM 3051 CA2 0.0- 1.5 bar 0.011 bar absol. pressure meas. Environment 338 MP.GD RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. GDCS tank / GDCS 218 MP.MS1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW1 219 MP.MS2 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW2 344 MP.P1 F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Feed DW1->PCC1 341 MP.P1V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Vent PCC1->SC1 557 MP.P2F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Feed DW2->PCC2 342 MP.P2V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Vent PCC2->SC2 558 MP.P3F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Feed DW2->PCC3 343 MP.P3V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Vent PCC3->SC2 554 MP.RP.1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Reactor Pressure Vessel / RPV 58 MP.RP.2 RM 2088 A3 0.0-13.0 bar 0.293 bar absol. pressure meas. Reactor Pressure Vessel / RPV 221 MP.S1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Suppression Chamber 1/ SC1 222 MP.S2 RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. Suppression Chamber 2 / SC2 435 MPG.D1.1 LI1231 O2

.002-600 bar 4.0 %

air partial press. meas. Drywell 1/ DW1 439 MPG.D2.1 LI1231 02

.002-600 bar 4.0 %

air partial press. meas. Drywell 2 / DW2 377 MPG.S2 Li 123102

.002-600 bar 4.0 %

air partial press. meas. Suppression Chamber 2 / SC2 482 MTF.GD.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS

I ALPHA-620-0 / Page 37 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 480 MTF.GD.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 479 MTF.GD.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 478 MTF.GD.4 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 477 MTF.GD.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 476 MTF.GD.6 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 475 MTF.GD.7 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 336 MTF.RP.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 335 MTF.RP.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 334 MTF.RP.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 96 MTF.RP.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 95 MTF.RP.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 474 MTG.D1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 473 MTG.D1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 472 MTG.D1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 471 MTG.D1.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 470 MTG.D1.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 469 MTG.D1.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 467 MTG.D2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 466 MTG.D2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 465 MTG.D2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 464 MTG.D2.4 PSI TC 1.0-196.58 C 0.8'C gas temp. meas. Drywell 2 / DW2 463 MTG.D2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2

ALPHA-620-0 / Page 38 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 462 MTG.D2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 717 MTG.GP1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCd-DW1 716 MTG.GP1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 715 MTG.GP2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCSDW2 714 MTG.GP2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 713 MTG.11.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 712 MTG.11.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 711 MTG.11.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 710 MTG.11.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 709 MTG.11.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 708 MTG.11.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 707 MTG.11.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 706 MTG.11.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 705 MTG.11.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 571 MTG.11 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. IC Feed RPV->lC f

459 MTG.11 F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 704 MTG.11 F.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 237 MTG.MS1.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW1 458 MTG.MS1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 456 MTG.MS1.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 238 MTG.MS2.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW2 455 MTG.MS2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2

ALPHA-620-0 / Page 39 Table A.1: M108 Data Identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 454 MTG.MS2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2 287 MTG.MV1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1 >SC1 333 MTG.MV1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 216 MTG.MV1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 215 MTG.MV1.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 286 MTG.MV2.1 PSITC 1.0-196.b8 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 332 MTG.MV2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 214 MTG.MV2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 213 MTG.MV2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 703 MTG.P1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCCI Condenser 702 MTG.P1.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 701 MTG.P1.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 700 MTG.P1.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 699 MTG.P1.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 698 MTG.P1.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 696 MTG PI.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCCI Condenser 695 MTG.P1.8 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 694 MTG.P1.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 572 MTG.P1 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC1 Feed DW1->PCC1 693 MTG.P1 F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Feed DW1->PCC1 365 MTG.P1V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC 1 Vent PCC1->SC1 692 MTG.P1V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1

ALPHA-620-0 / Page 40 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 331 MTG.P1V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 212 MTG.P1V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCCI Vent PCC1->SC1 211 MTG.P1V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 691 MTG.P2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 690 MTG.P2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 689 MTG.P2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 688 MTG.P2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 687 MTG.P2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 686 MTG.P2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 685 MTG.P2.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 684 MTG.P2.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 683 MTG.P2.9 PSITC 1.0-196.5,8 C 0.8 C gas temp. meas. PCC2 Condenser 573 MTG.P2F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC2 Feed DW2->PCC2 682 MTG.P2F.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Feed DW2->PCC2 366 MTG.P2V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC2 Vent PCC2->SC2 681 MTG.P2V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 330 MTG.P2V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 210 MTG.P2V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 209 MTG.P2V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 528 MTG.P3.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 527 MTG.P3.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 526 MTG.P3.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser

l l

ALPHA-620-0 / Page 41 Table A.1: M108 Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 525 MTG.P3.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 524 MTG.P3.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 523 MTG.P3.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 522 MTG.P3.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 521 MTG.P3.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 520 MTG.P3.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 574 MTG.P3F.1 HB Pt100 0.0-200.00 G 0.2 C gas temp. meas. PCC3 Feed DW2->PCC3 680 MTG.P3F.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Feed DW2->PCC3 367 MTG.P3V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC3 Vent PCC3->SC2 679 MTG.P3V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 329 MTG.P3V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 208 MTG.P3V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 207 MTG.P3V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 206 MTG.S1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SCI 205 MTG.SI.2 PSITC 1.0-196.58 C 0.8 C gas te.np. meas. Suppression Chamber 1/ SC1 204 MTG.SI.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 203 MTG.S1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 202 MTG.S t.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 201 MTG.SI.6 PSITC 1.0-196.53 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 199 MTG.S2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 198 MTG.S2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 197 MTG.S2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 m

-m

+

ALPliA-620-0 / Page 42 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 196 MTG.S2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 195 MTG.S2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 194 MTG.S2.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 449 MTG.TDO.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 448 MTG.TDO.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 447 MTG.TDO.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 328 MTG.TSU.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 327 MTG.TSU.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 326 MTG.TSU.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 325 MTG.VB1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 324 MTG.VB1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 446 MTG.VB1.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 445 MTG.VB1.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 323 MTG.VB2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 322 MTG.VB2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 444 MTG.VB2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 443 MTG.VB2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 283 MTI.DI.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 282 MTI.D1.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 281 MTI.D1.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 280 MTI.D1.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 279 MTI.DI.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1

I ALPHA-620-0 / Page 43 Table A.1: M10B Data identification conid.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 278 MTI.D1.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 277 MTI.DI.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 276 MTI.DI.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 275 MTI.D1.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 274 MTI.D2.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 273 MTI.D2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 272 MTI.D2.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 271 MTI.D2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 270 MTI.D2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 269 MTI.D2.6 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 268 MTI.D2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 i DW2 267 MT1.D2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 266 MT1.D2.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 263 MTI.GD.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 262 MTI.GD.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 261 MTI.GD.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 260 MTI.GD.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 259 MTI.GD.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 258 MTI.GD.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 244 MTI.RP.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 243 MTI.RP.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 242 MT1.RP.3 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV

ALPHA-620-0 / Page 44 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 191 MTI.SI.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 190 MTI.SI.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 189 MTI.SI.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 188 MTI.SI.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 187 MTI.S1.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 186 MTI.SI.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 185 MTI.SI.7 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 184 MTI.SI.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 183 MTI.S1.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 182 MTI.S2.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 181 MTI.S2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 180 MTI.S2.3 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 179 MTI.S2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 178 MTI.S2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 177 MTI.S2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 176 MTI.S2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 175 MTI.S2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 174 MTI.S2.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 14 MTL.EOO HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. EOualization line common branch 15 MTLGRT.1 HB Pt100 0.0-200.00 C 0.2 C liquid temp. meas. Condensate Retum GDCS->RPV 88 MTL GRT.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Retum GDCS->RPV 317 MTL.GRT.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Retum GDCS->RPV

.m-...

m.

m.

-u m a

l ALPHA-620-0 / Page 45 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION i

674 MTL.11 PSITC 1.0-196.58 C

' O.8 C liquid temp. meas. IC Condenser 16 MTL.11C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. IC Condensate IC->RPV 672 MTL.11C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV 173 MTL.11C.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV 671 MTL.P1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condenser 234 MTL.PIC.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 670 MTL.PI C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 669 MTL.P2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condenser 235 MTL.P2C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 668 MTL.P2C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 519 MTL.P3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condenser 236 MTL.P3C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 667 MTL.P3C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 86 MTL.RP.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 85 MTL.RP.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 172 MTL.SI.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 171 MTLSI.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 170 MTL.SI.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 168 MTL.SI.4 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 167 MTL.SI.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 166 MTL.S t.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 165 MTL.S2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2

ALPHA-620-0 / Page 46 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 164 MTL.S2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 163 MTL.S2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 162 MTL.S2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 161 MTL.S2.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 160 MTL.S2.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 159 MTL.TSL1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 158 MTL.TSL.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 157 MTLTSL.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 432 MTLUO.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 431 MTL.UO.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 430 MTLUO.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 429 MTL.UO.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 428 MTLUO.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 427 MTL.UO.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 426 MTLUO.7 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 657 MTL.U1.1 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 656 MTL.U1.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 655 MTL.U 1.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 654 MTLUI.4 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 653 MTL.U 1.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 652 MTL.U I.6 PSITC 1.0-196.58 C 0.8' C liquid temp. meas. PCC1 pool 651 MTLUI.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool

- ~

l l

ALPHA-620-0 / Page 47 Table A.1: M10B Data identification contd.

DACHANNEL PROCESS 1D TYPE RANGE / UNIT ACCURACY LOCATION 647 MTL.U2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 646 MTLU2.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 645 MTL.02.3 -

PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 644 MTL.U2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 643 MTL.U2.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 642 MTLU2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 641 MTL.U2.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 518 MTL.U3.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 517 MTLU3.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 516 MTLU3.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 515 MTLU3.4 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 514 MTLU3.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 513 MTLU3.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 512 MTL.U3.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 511 MTL.U3.8 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 510 MTL.U3.9 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 509 MTL.U3.10 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 508 MTL.U3.11 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 507 MTL.U3.12 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 506 MTL.U3.13 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 504 MTLU3.14 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 503 MTL.U3.15 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool

ALPHA-620-0 / Page 48 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 502 MTL.U3.16 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 501 MTL.U3.17 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 500 MTL.U3.18 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 499 MTL.U3.19 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 636 MTO.DI.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 635 MTO.D1.2 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 634 MTO.D1.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 254 MTO.D1.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 253 MTO.DI.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 252 MTO.D1.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 315 MTO.D1.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 314 MTO.D1.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 312 MTO.DI.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 633 MTO.D2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 632 MTO.D2.2 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 631 MTO.D2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 257 MTO.D2.4 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 256 MTO.D2.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 255 MTO.D2.6 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 311 MTO.D2.7 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 310 MTO.D2.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 309 MTO.D2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2

l ALPHA-620-0 / Page 49 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 251 MTO.GD.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 250 MTO.GD.2 PSITC 1.0-196.56 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 249 MTO.GD.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 248 MTO.GD.4 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 247 MTO.GD.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 246 MTO.GD.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 308 MTO.S1.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 307 MTO.S t.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 306 MTO.S t.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 156 MTO.S1.4 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 155 MTO.SI.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 154 MTO.S1.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 80 MTO.S1.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 79 MTO.S t.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 78 MTO.SI.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 305 MTO.S2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 304 MTO.S2.2 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 303 MTO.S2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Cnamber 2 / SC2 153 MTO.S2.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 152 MTO.S2.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 151 MTO.S2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 77 MTO.S2.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2

l 1

ALPHA-620-0 / Page 50 Table A.1: M10B Data identification contd.

DACHANNEL-PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 76 MTO.S2.8 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. sppression Chamber 2 / SC2 75 MTO.S2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 434 MTP.DI.1 LiTC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 1/ DW1 438 MTP.D2.1 LiTC 0.0-1000.0 C 0.75 %

Temp for oxygen Probe Drywell 2 / DW2 376 MTP.S2 L1 TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Suppression Chamber 2 / SC2 408 MTS.D1.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 407 MTS.D1.2 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 406 MTS.D1.3 PSITC 1.0-196.58 C 0.6 C pool sudace temp. meas. Drywell 1/ DW1 405 MTS.D2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 404 MTS.D2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 403 MTS.D2.3 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 402 MTS.GD.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 401 MTS.GD.2 PSI TC 1.0-196.58 C 0.6 C pool sudace temp. meas. GDCS tank / GDCS 400 MTS.GD.3 PSITC 1.0-196.58 C 0.6 C pool sudace temp. meas. GDCS tank / GDCS 150 MTS.S t.1 PSI TC 1.0-196.58 C 0.6 C pool sudace temp. meas. Suppression Chamber 1/ SC1 149 MTS.S1.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 148 MTS.S t.3 PSITC 1.0-196.58 C 0.6 C pool sudace temp. meas. Suppression Chamber 1/ SC1 147 MTS.S2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 146 MTS.S2.2 PSITC 1.0-196.58 C 0.6 C pool sudace temp. meas. Suppression Chamber 2 / SC2 144 MTS.S2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 425 MTT.11.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 424 MTT.11.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser

ALPHA-620-0 / Page 51 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE FLANGE / UNIT ACCURACY LOCATION 423 MTT.11.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 422 MTT.11.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 421 MTT.11.5 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 420 MTT.11.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 419 MTT.11.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 418 MTT.11.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 417 MTT.11.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 416 MTT.11.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 415 MTT.11.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 414 MTT.11.12 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 413 MTT.11.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 412 MTT.11.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 411 MTT.11.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 410 MTT.11.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 613 MTT.P1.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 612 MTT.P1.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 611 MTT.P1.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 610 MTT.P1.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 609 MTT.P1.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 608 MTT.P1.6 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 607 MTT.P 1.7 PSITC 1.0-196.58 C 0.8'C tube wall temp. meas. PCC1 Condenser 606 MTT.P1.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser

l ALPHA-620 0 / Page 52 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE FIANGE/ UNIT ACCURACY LOCATION 605 MTT.P1.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 604 MTT.P1.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Cond'enser 603 MIT.P1.11 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 602 MTT.P1.12 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 600 MTT.P1.13 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 599 MTT.P1.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 598 MTT.P1.15 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 597 MTT.P1.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 630 MTT.P2.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 629 MTT.P2.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 628 MTT.P2.3 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 627 MTT.P2.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 626 MTT.P2.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 624 MIT.P2.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 623 MTT.P2.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 622 MTT.P2.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 621 MTT.P2.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 620 MTT.P2.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 619 MTT.P2.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 618 MTT.P2.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 617 MTT.P2.13 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 616 MTT.P2.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser

I ALPHA-620-0 / Page 53 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 615 MTT.P2.15 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 614 MTT.P2.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 498 MTT.P3.1 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 497 MTT.P3.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 496 MTT.P3.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 495 MTT.P3.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 494 MTT.P3.5 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 493 MTT.P3.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 492 MTT.P3.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 491 MTT.P3.8 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 490 MTT.P3.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 489 MTT.P3.10 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 488 MTT.P3.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 487 MTT.P3.12 PSITC 1.0-196.58 C 0.8 C tube wait temp. meas. PCC3 Condenser 486 MTT.P3.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 485 MTT.P3.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser -

484 MTT.P3.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 483 M~lT.P3.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 569 MTV.GP1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 568 MTV.GP1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 567 MTV.GP2.1 PSITC 1.0-196.58 C 0.8'C wall temp. meas. GDCS Pressure equal. GDCS-DW2 566 MTV.GP2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2

4 ALPHA-620-0 / Page 54 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE

' RANGE / UNIT ACCURACY LOCATION 302 MTV.GRT PSiTC 1.0-196.58 C 0.8 C wall temp. meas. Condensate Retum GDCS->RPV 596 MTV.11C PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Condensate IC->RPV 594 MTV.11 F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 399 MTV.11 F.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 595 MTV.11 F.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 397 MTV.MSI.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 398 MTV.MSI.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 396 MTV.MSI.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 394 MTV.MS2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 395 MTV.MS2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 393 MTV.MS2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 292 MTV.MV1.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 301 MTV.MV1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 140 MTV.MV1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1-> SCI i

291 MTV.MV2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 300 MTV.MV2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 141 MTV.MV2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 593 MTV.PIC PSITC 1.0-196.58 C.

0.8 C wall temp. meas. PCC1 Condensate PCC1->GDCS 592 MTV.P1 F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCCI 591 MTV.P1 F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 390 MTV.P1V.1 PSITC 1.0-196.58 C 0.8 C walltemp. meas. PCC1 Vent PCC1->SC1 590 MTV.P1V.2 PSt TC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1

ALPHA-620-0 / Page 55 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 299 MTV.P1 V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1-> SCI 137 MTV.P1V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1-> SCI 589 MTV.P2C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Condensate PCC2->GDCS 588 MTV.P2F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 587 MTV.P2F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 389 MTV.P2V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 586 MTV.P2V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 298 MTV.P2V.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 138 MTV.P2V.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 585 MTV.P3C PSI TC 1.0-196.58 C O.8 C wall temp. meas. PCC3 Condensate PCC3->GDCS 584 MTV.P3F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 583 MTV.P3F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 388 MTV.P3V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 582 MTV.P3V.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 297 MTV.P3V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 139 MTV.P3V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 296 MTV.VB1.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 294 MTV.VB1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SCI-DW1 382 MTV.VB1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 384 MTV.VB1.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 295 MTV.VB2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 293 MTV.VB2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2

ALPHA-620-0 / Page 56 Table A.1: M10B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 379 MTV.VB2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 381 MTV.VB2.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 118 MV.GRT I USON 994 449-2722 g/s 2.0 %

volume flow meas. Condensate Return GDCS->RPV 358 MV.MSI I VORTEX 100 135-595 g/s 1.5 %

volume flow meas. Main Steam line RPV->DW1 359 MV.MS2 I VORTEX 100 134-592 g/s 1.5 %

volumc flow meas. Main Steam line RPV->DW2 562 MV.P1F 1 VORTEX 80 72-311 g/s 1.5 %

volume flow meas. PCC1 Feed DW1 >PCC1 352 MV.P1V I VORTEX 80 68-262 g/s 2.0 %

volume flow meas. PCC1 Vent PCC1->SC1 563 MV.P2F i VORTEX 80 73-327 g/s 1.5 %

volume flow meas. PCC2 Feed DW2->PCC2 353 MV.P2V I VORTEX 80 62-259 g/s 2.0 %

volume flow meas. PCC2 Vent PCC2->SC2 116 MV.P3C I USON 994 53-387 g/s 2.0 %

volume flow meas. PCC3 Condensate PCC3->GDCS 564 MV.P3F 1 VORTEX 80 71-342 g/s 1.5 %

volume flow meas. PCC3 Feed DW2->PCC3 354 MV.P3V I VORTEX 80 63-263 g/s 2.0 %

volume flow meas. PCC3 Vent PCC3->SC2 42 MW.RP.1 CB SYNEAX 0 - 50 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 43 MW.RP.2 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 44 MW.RP.3 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 45 MW.RP.4 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 46 MW.RP.5 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 47 MW.RP.6 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 48 MW.RP.7 HB TZA4 TOT 0 - 1500 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV A Total of 501 Data Records