Text
1 1
)
I PAUL SCHERRER INSTITUT EN ~
3iiEl i
Document No.
ALPHA-615 Document Title PANDA Transient Tests M3A Integral System Test Data Transmittal Report i
l Revision Status Approval / Date Rev.
Prepared / Revised by P PM G PM lG-SQR lssue Date Remarks 0
M. Huggenberger 21[ $
d.
J. Torbeck G. Wingate 28 June 96 co, [r0N.
v3 -h 27 June 96 27 June 96
.o E au-5' o ?
A600 dnc/:s 06 io96 9608200164 960916 PDR ADOCK 05200004 A
- l. g ALPHA-615 / Seite 2 i
1 Controlled Copy (CC) Distribution List Note: Standard distribution (cf. next page) is non-controlled l
CC Holder CC List Entry Return / Recall No.
Name, Affiliation Date Date 1
)
i i
i i
J 1
l l
1 1
I l
r
.i t
a I
g i
1,.
Pepsmerr2 f
~
PAUL SCHERRER INSTITUT 42-96-18 ALPHA-615-0 PANDA Transient Tests Ersetzt Titel M3A Integral System Test Data Transmittal Report Er m Autoren/
M. Huggenberger, C. Aubert, J. Dreier, O. Fischer, Autennnen S. Lomperski, H.J. Strassberger
- 27. June 1996 Summary:
This Data Transmittal Report (DTR) summarizes the results of the PANDA transient system test M3A which is a simulation of a break in the main steam line of the SBWR. The test was conducted with nominal initial conditions, similar to those calculated for the SBWR under SSAR assumptions at one hour into the LOCA. One-half of the steam flow from the RPV was directed to drywell 1 and the other one-half to drywell 2 (symmetric case). The objectives of the 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> test M3A are to demonstrate the repeatability of key parameters of the base case test M3 and to show the effect of PCC/IC pool configuration / refilling on global system performance.
The DTR, for test M3A together with the Umbrella DTR satisfies the requirements specified in the Test Plan (TP) 25A5764 Rev 2 (GE document) section 10. The DTR includes: General descnption and purpose of test, test facility configuration description and a table of actual and specified initial conditions. Further, the test results are presented by time history plots over the test duration and the main observations are given.
During test M3A five vacuum breaker openings occurred. They were initiated by the periodic PCC pool refillings to maintain levels. These VB openings did not affect the global DW/WW pressure response, which followed very closely the M3 pressure curve. The hydraulically isolated PCC/IC pools allows for heat balances which address some of the flow
)
measurement problems, identified in test M3.
The M3A test objectives have been reached.
f Vertes Abt.
Empf&nger/ Empfingennnen Expt Abt.
Empf&nger / Empfingennnen Expt Expt 42 G. Yadigaroglu 1
GE San Jose CA Bibliothek G. Varadi 1
J.E. Torbeck 1
C. Aubert 1
(for distribution'at GE to msm 5
T. Bandurski 1
J.R. Fitch, G.A. Wingate' J. Dreier 1
B.S. Shiralkar.
Mal 18 O. Fischer 1
DRF No. T10-0005)
J. Healzer 1
Senen 59 M. Huggenberger 1
Beilagen S. Lomperski 1
H.J. Strassberger 1
infomancesace 2l d 4 5
8 9
A PANDA Documentation 2
D 1
Visum Abt./Latcr:ertung
i 4
ALPHA-615-0 / Page 4 Contents i
- 1. INTRODUCTION 5
]
1.1 General Description and Purpose of Test 5
1.2 Purpose of Report 5
l
- 2. TEST OBJECTIVES 5
2.1 General Objectives 5
2.2 Specific Objectives 6
j
- 3. TEST FACILITY CONFIGURATION AND INITIAL CONDITIONS 6
3.1 Test Facility Configuration 6
3.2 Test Initial Conditions 6
l
- 4. TEST RESULTS 12
)
4.1 Main Observations 12 4.2 Time History Plots 13
- 5. CONCLUSIONS 33 5.1 Adequacy of Test Data 33 5.2 Applicability to Test Objectives 33
- 6. REFERENCE DOCUMENTS 34 APPENDIX: COMPOSITION OF DATA RECORDS 35 i
ALPHA-615-0 / Page 5
- 1. Introduction 1.1 General Description and Purpose of Test i
i Test M3A is a repetition of the base case test M3. Adaitionally, the effect of hydraulically isolated J
PCC/IC pools and the influence of periodic pool refilling on the global system performance were investigated. M3A is a simulation of a break in the main steam line of the SBWR. The nominal initial containment conditions were similar to those calculated for the SBWR under SSAR assumptions at one hour into the LOCA. The initial drywell pressure was approximately 300 kPa.
One-half of the steam from the RPV was directed to DW1 which feeds one PCC condenser, and the other one-half of the steam was directed to DW2 with two PCC condensers connected. This was achieved with separate blowdown lines from the RPV to each of the two drywells. The two blowdown lines have essentia!!y equal flow resistances. These test conditions represent a symmetrical situation in the PANDA facility. This test provides data for comparison with tests M3 (base case) and M3B (repeatability and effect of PCC/IC pool configuration).
1.2 Purpose of Report This Data Transmittal Report (DTR) is compiled in accordance with the requirements specified in Test Plan (TP) 25A5764 Rev 2 (GE document) Section 10 [1]. The report covers the results for 1
the transient integral system test M3A which has been run in accordance with the test procedure described in [2]. The DTR provides detailed information about test objectives, the test facility configuration and the test initial conditions. The test results main observations are reported and a number of plots, which support the findings are included. The conclusions about the adequacy of test data and the applicability of test objectives are given. The composition of the data record is desenbed in an Appendix. The general information about the overall test program, the PANDA facility, the instrumentation, the data acquisition system, the facility characterization tests, the PANDA experimental data base and the error analysis is described in the DTR umbrella report
[4). The apparent test reaults for test M3A are summarized in (3).
l
- 2. Test Objectives 2.1 General Objectives The objectives of the PANDA integral system tests are to provide additional data to: a) confirm the capability of TRACG to predict SBWR containment system performance, including potential systems interaction effects (Integral System Tests) and b) demonstrate startup and long term operation of a passive containment cooling system (Concept Demonstration).
I ALPHA-615-0 / Page 6 l
2.2 Specific Objectives The specific objectives of test M3A which was conducted with nominal post-LOCA conditions one l
hour after a Main Steam Line Break are:
- To demonstrate transient system response and repeatability of key parameters of the base case test M3.
- To show the effect of PCC/IC pool configuration and periodic pool refilling on the global PCC system behaviour.
- 3. Test Facility Configuration and Initial Conditions 1
3.1 Test Facility Configuration The PANDA test facility is described in detail in Section 3 of PSI report ALPHA-606 [4]. For test M3A the PANDA facility was configured to simulate the SBWR post-LOCA configuration as follows:
- 1) The RPV supplies steam to each drywell with two steam lines (one to each drywell). These two steam lines have the same pressure loss characteristics and, therefore, allow for symmetric injection of steam into the two drywells.
- 2) RPV heater power is controlled as a function of time to simulate the scaled decay heat and stored energy release (as specified in [1]).
- 3) The IC unit is isolated by closing the inlet and outlet valves (i.e., the IC feed, drain and vent lines are closed).
- 4) All three PCC units are lined-up to take feedflow from the drywells, to vent noncondensables and steam into the water volume of the suppression pool, and drain condensate to the GDCS volume.
- 5) The three PCC pools and the IC pool are isolated from each other. During the test, water is added to the PCC pools (with a flow rate of approximately 2 kg/s) via the auxiliary water system as needed, from the bottom to maintain level.
- 6) The only direct lines of communication between the drywell and wetwell are through the vacuum breakers (when the wetwell pressure exceeds drywell pressure sufficiently to open the vacuum breaker) and the main vent lines (which are submerged within the wetwells).
- 7) The GDCS pressure equalization lines to both drywells are open.
- 8) The GDCS drain line with check valve is lined up to return PCC condensate to the RPV.
- 9) The Equalizing lines between the RPV and wetwells are valved out of service.
l 3.2 Test initial Conditions l
The test initial conditions represent the state of the system one hour after scram. These conditions are presented in Table 3.1. The " Average Value' represents the arithmetic mean over the one minute measurement period just before connecting the drywells to the RPV. The
" Requested Value" is the value as it is specified in the Test Plan [1].
ALPHA 615-0 / Page 7 i
l l
Table 3.1: Test M3A initial Conditions VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value ENVIRONMENT PARAMETERS i
Atmospheric pressure MP.EN t
Temperature of saturation for atmospheric pressure (Tsat.EN)
RPV PARAMETERS j
Total pressure MP.RP.1 bi Fluid temperatures:
Spatial average TF_mean (RP)
C Local MTF.R P.1 C
MTF.RP.2 C
MTF.RP.3 C
MTF.RP.4 C
MTF.RP.5 C
DRYWELL PARAMETERS
' Total pressure MP.D1 bar
' Air partial pressure MPG.D1.1 bar MPG.D1.2 bar MPG.D2.1 bar MPG.D2.2 bar i
Gas temperatures:
Spatial average Tg_m,,n(D1)
C Local MTG.D1.1 C
MTG.D1.2 C
MTG.D1.3 C
MTG.D1.4 C
MTG.D1.5 C
MTG.D1.6 C
3 The Drywell total pressures are not independant variables, they are given by temperatures and air partial pressures The corresporicing tolerance is calculated from temperature and gas partial pressure tolerances.
Refer to Test Procedure on how the air partial pressure is adjusted in the Dws (not based on oxygen probe measurements, but on pressure increase during air injection).
l*
ALPHA-615-0 / Page 8 f
l Table 3.1: Test M3A initial Conditions Contd.
VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value l
l l
DRYWELL PARAMETERS (Cont'd)
- Gas temperatures:
Spatial averagt TG_mean (D2)
C Local MTG.D2.1 C
MTG.D2.2 C
MTG.02.3 C
MTG.D2.4 C
MTG.D2.5 C
MTG.D2.6 C
Water level ML.D1 m
ML.D2 m
SUPPRESSION CHAMBER PARAMETER' Total pressure MP.S1 bar
' Air partial pressure MPG.S1 bar MPG.S2 bar Water temperatures:
Spatial average Tw_mean (S1)
C Local MTL.S1.1 C
MTL.S1.2 C
MTL.S1.3 C
MTL.S1.4 C
MTL.S1.5 C
MTL.S1.6 C
Spatial average Tw mean (S2)
C Local MTL.S2_1 C
MTL.S2.2 C
MTL.S2.3 C
MTL.S2.4 C
l I
' The suppression Chamber air partial pressures are not independant vanables, they are gnren by temperatures and total pressures The I
corresponding tolerance was set Dy Psi (caculated from temperature and total pressure tolerances) and the listed initial conditions do not Constitute a deviation from the Test Plan.
I l
ALPHA-615-0 / Page 9 MTL.S2.4 C
Table 3.1: Test M3A Initial Conditions Contd.
VARIABLE PROCESSID UNIT Average Standard Requested Tolerance l
Value Deviation Value SUPPRESSION CHAMBER PARAMETERS (Cont'd) l Water Temperatures:
MTL.S2.5 C
MTL.S2.6 C
l
)
Gas temperatures Spatial average Tg,m,n(S1)
C Gas temperatures Local MTG.S1.1 C
MTG.S1.2 C
MTG.S1.3 C
MTG.S1.4 C
]
MTG.S1.5 C
MTG.S1.6 C
Spatial average TG_mean (S2)
C Local MTG.S2.1 C
j MTG.S2.2 C
MTG.S2.3 C
l MTG.S2.4 C
i MTG.S2.5 C
MTG.S2.6 C
GDCS PARAMETERS Total pressure MP.GD bar Fluid temperatures:
Spatial average Tp,,,,n (GD)
C
(
Local MTF.GD.1 C
MTF.GD.2 C
MTF.GD.3 C
l l
l
ALPHA-615-0 / Page 10 l
Table 3.1: Test M3A initial Conditions Contd.
VARIABLE PROCESSID UNIT Average
. Standard Requested Tolerance j
' Value Deviation Value j
GDCS PARAMETERS (Cont'd)
MTF.GD.4 C
MTF.GD.5 C
l MTF.G D.6 C
MTF.GD.7 C
Water level ML.GD m
PCC1 PARAMETERS Water temperatures-Spatial average Tw m,,n(U1)
C i
Local MTL.U1.1 C
MTL.U1.2 C
MTL.U1.3 C
MTL.U1.4 C
MTL.U1.5 C
MTL.U1.6 C
i MTL.U1.7 C
Water level ML.U1 m
PCC2 PARAMETERS Water temperatures:
Spatial average Tw_mean (U2)
C Local MTL.U2.1 C
MTL.U2.2 C
MTL.U2.3 C
MTL.U2.4 C
MTL.U2.5 C
MTL.U2.
C MTL.U2.7 C
Water level ML.U2 m
_m I
j' ALPHA-615-0 / Page 11 l
l Table 3.1: Test M3A Initial Conditions Contd.
VARIABLE PROCESSID UNIT Average Standard Requested Tolerance I
Value Deviation Value r
PCC3 PARAMETERS l
l Water temperatures:
Spatial average Tw,m,,n(U3)
C Local MTL.U3.1 C
i MTL.U3.2 C
MTL.U3.3 C
MTL.U3.4 C
MTL.U3.5 C
MTL.U3.6 C
MTL.U3.7 C
MTL.U3.8 C
MTL.U3.9 C
MTL.U3.10 C
MTL.U3.11 C
MTL.U3.12 C
MTL.U3.13 C
MTL.U3.14 C
MTL.U3.15 C
i MTL.U3.16 C
MTL.U3.17 C
MTL.U3.18 C
MTL.U3.19 C'
Water level ML.U3 m
List of Deviations from Requested initial Conditions:
Water levelin GDCS pool ML.GD Water levelin PCC1 pool ML.U1 l
Water level in PCC2 pool ML.U2 Total pressure in RPV MP.RP l
Total pressure in GDCS MP.GD l'
Air partial pressure in Drywell 2 MPG.D2.1 All the deviations listed above are minor and they did not affect the test results (cf. [3]).
ALPHA-615-0 / Page 12
- 4. Test Results The main observations for the test M3A are presented in Section 4... A standard set of time history plots for the key parameters and additional plots which support the individual test observations are given in Section 4.2.
4.1 Main Observations
1 ALPHA-615-0 / Page 13 l
i i
1 j
l i
4.2 Time History Plots Time history plots are provided to support the observations discussed in Section 4.1 for the following parameters:
Figure RPV, Drywell and Wetwell Pressures 1
PCC Feed Mass Flow Rates 2
PCC1 Temperatures 3
PCC2 Temperatures 4
PCC3 Temperatures 5
PCC Vent Phase Detectors 6
PCC Vent Line Gas Temperatures 7
Drywell Air Partial Pressures 8
ALPHA-615-0 / Page 14 Figure Wetwell Air Partial Pressures 9
PCC Pool Levels 10 RPV Heater Power 11 RPV and Drywell Temperatures 12 Wetwell Gas and Water Ternperatures 13' Main Steam Line Mass Flow Rates 14 Vacuum Breaker 1 Position 15 Vacuum Breaker 1 Line Temperatures 16 PCC Pool Temperatures 17 GDCS Return Line Temperature 18 The identification code for the process variables used in the plots is explained in the DTR Umbrella Report, Section 4 [4). Also, the DAS channel, type, range, accuracy and location of each instrument are given in the Appendix ' Composition of Data Records'.
1 1
i
4 ALPHA-615-0 / Pages 15 through 32 1
These pages have been deleted from this nonproprietary version of this report, because Figures 1 through I8 which are on these pages in the proprietary version of the report contain proprietary information.
T t
l 1
.i a
i i
l i
J 4
4 4
e 4
d i
i e
n i
i
}
I T
ALPHA-615-0 / Page 33 l
i
- 5. Conclusions l
l 5.1 Adequacy of Test Data l
l The integral system test M3A has provided data of the overall system behaviour in an adequate i
5 manner. Based on the analysis of the test data [3] the test acceptance enteria have clearly been reached. All zero and instrument checks for test M3A have been successfully completed and the instrument readings were within the permitted ranges.
l All required instrumentation performed well except for the two oxygen sensors at the lowest levels l
in DW1 and DW2. This was acceptable because the backup oxygen sensors at higher elevations j
in the drywell did work.
5.2 Applicability to Test Objectives l
l The test objectives as stated in Section 2 of this report have been reached:
- A comparison of the data from test M3A and the base case test M3 showed generally the same overall system behaviour for both tests. DW and WW pressures followed very similar trends. The DW peak pressures differed by only 4 kPa.
- The PCC/IC pool configuration for test M3A (isolated pools) and the periodic refilling of the l
pools lead to five vacuum breaker openings throughout the test, but this did not affect the global system performance.
The PCC pool level response with the isolated pools can be used to accurately determine the heat removal rate from the iridividual PCC units.
l Repeatability has successfully been demonstrated.
l l
l
)
l l
~_
i ALPHA 615-0 / Page 34 i
- 6. Reference Documents
[1]
" PANDA Test Plan-Tests M3, M3A, M3B, M4, M7" (Specification), GE Document 25A5764 Rev. 2, Oct 16,1995.
[2]
" PANDA Transient Tests: M3A, M3B & M4 Integral System Test Procedure", PSI internal Report ALPHA-520-2, Oct 24,1995.
[3]
" PANDA Transient Tests: M3A Integral System Test Apparent Test Results", PSI Internal Report ALPHA-604-0, March 29,1996, Proprietary information.
[4]
" PANDA Facility Test Program and Data Base General Description (DTR Umbrella Report) ",
[
PSI Internal Report ALPHA-606-0, May 31,1996.
[5]
"SBWR Test and Analysis Program Description" TAPD (Licensing Topical Report), GE Report NEDC-32391P Rev. C, August 1995, GE Proprietaryinformation.
b i
l 6
l 1
l t
i i
l
- ~
J ALPHA-615-0 / Page 35 1
i Appendix: Composition of Data Records Data Transfer for PANDA Test M3A All variables given by the Table A.1 are contained in four ORACLE tables:
GE_ PANDA _M3A_MT_LINE 36575 rows e
GE_ PANDA _M3A_MT_ POOL 36575 rows GE_ PANDA _M3A_MT_ VESSEL 36575 rows GE_PANC ~
'l M_OTHER 36575 rows All contain thc variable called REC _ID (record identifier) allowing to link records to corresponding time.
Time data are given in the table:
GE_ PANDA _M3A_M_ TIME 36575 rows The structure of all these tables is exactly the same as the one described in the DTR umbrella report [4] for corresponding tables labeled without "GE_"
(PANDA _M3A_..
inst'ead of j
GE_ PANDA _M3A...); new table names have been used because of database consistency!
All these tables are owned by the user "aubert" and have been created in the tablespace
" USERS"; they have been exported in file "M3A_GE_ tables.dmp".
1 l
Measurements with restricted use i
)
MV.P3C only qualitative use possible (for example oscillations etc.) absolute value is not reliable MV.GRT only qualitative use possible (for example oscillations etc.) absolute value is not reliable
]-
MV.P1V MV.P2V during whole test below lower flow limit MV.P3V s
MV.MS1 below lower flow limit (cf. Figure 14)
MV.MS2 MV.P1F
]
MV.P2F temporary below lower flow limit (cf. Figure 2)
MV.P3F j
I ALPHA-615-0 / Page 36
[
Table A.1: M3A Data identification DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 230 CB.VB1 KEY.NOR.AUT 0,50 or 100%
On/Off valvo Vacuum Breaker SC1-DW1 231-CB.VB2 KEY.NOR.AUT 0,50 or 100%
On/Off valve Vacuum Breaker SC2-DW2 105 MD.GRT RM 1151 DP5
-36.- 150. kPa 1.68 kPa pressure diff. meas. Condensate Return GDCS->RPV 3
530 MD.MS1 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW1 531 MD.MS2 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW2 f
98 MD.MV1 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW1->SC1 I
99 MD.MV2 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW2->SC2 L
537 MD.P1 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC1 Condenser I
540 MD.PI C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC1 Condensate PCC1->GDCS k
533 MD.P1 F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC1 Feed DW1->PCC1
[
-15.- 22. kPa 0.34 kPa pressure diff. meas. PCCI Vent PCC1->SC1 101 MD.P1V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC1 Vent PCC1->SC1 538 MD.P2 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC2 Condenser 541 MD.P2C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC2 Condensate PCC2->GDCS f
534 MD.P2F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas PCC2 Feed DW2->PCC2 545 MD.P2V.1 RM 1151 DP4
-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 i
102 MD.P2V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 539 MD.P3 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC3 Condenser 542 MD.P3C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC3 Condensate PCC3->GDCS 535 MD.P3F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC3 Feed DW2->PCC3 S46 MD.P3V.1 RM 1151 DP4
-15.- 22. kPa 0.34 k'Pa pressure diff. meas. PCC3 Vent PCC3->SC2 103 MD.P3V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC3 Vent PCC3->SC2 I
t
~
m
... ~
m
ALPHA-615-0 / Page 37 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 224 MD.VB1 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC1-DW1 225 MD.VB2 RM 3051 CD2 20.- 46. kPa 0.t9 kPa pressure diff. meas. Vacuum Breaker SC2-DW2 36 ME.RP EH MYCOM 0 - 200 pS/cm 0.5 %
water quality meas. Reactor Pressure Vessel / RPV 70 MI.MV1 PSI /GA COND 0 or 1 phase indicator Main Vent line DW1->SC1 71 MI.MV2 PSI /GA COND 0 or 1 phase indicator Main Vent line DW2->SC2 67 MI.P1V.1 PSI /GA COND 0 or 1 phase indicator PCCI Vent PCC1-> SCI 68 Mt.P2V.1 PSI /GA COND 0 or 1 phase indicator PCC2 Vent PCC2->SC2 69 MI.P3V.1 PSl/GA COND 0 or 1 phase indicator PCC3 Vent PCC3->SC2 227 ML.D1 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 1/ DW1 228 ML.D2 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 2 / DW2 229 ML.GD RM 3051 CD3 0-6.3 m 0.070 m level meas. GDCS tank / GDCS 113 ML.MSI RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW1 114 ML.MS2 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW2 8
ML.RP.1 RM 3051 CD3 0-21.5m 0.166 m level meas. Reactor Pressure Vessel / RPV 9
ML.RP.2 RM 1151 DPS 0-4.1 m 0.157 m level meas. Reactor Pressure Vessel / RPV 107 ML.RP.3 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 108 ML.RP.4 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 226 ML.RP.5 RM 1151 DPS 0-7.7 m 0.166 m level meas. Reactor Pressure Vessel / RPV 360 ML.RP.6 RM 1151 DPS 0-4.6 m 0.158 m level meas. Reaclor Pressure Vessel / RPV 110 ML.S1 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 1/ SCI 111 ML.S2 RM 3051 CD2 0-4.6 m 0.039'rn level meas. Suppression Chamber 2 / SC2 547 ML.UO RM 1151 DPS 0-5.6 m 0.156 m level meas. IC pool
ALPHA-615-0 / Page 38 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 548 PdL U1 RM 1151 DPS 0-5.6 m 0.156 m level meas. PCC1 pool 549 ML.U2 RM 1151 DPS 5.6 m 0.156 m level meas. PCC2 pool 550 ML.U3 RM 1151 DP5 0 5.6 m 0.156 m level meas. PCC3 pool 72 MO.VB 0 or 1 Vacuum Breaker Trigger signal 555 MP.D 1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Drywell 1/ DW1 556 MP.D2 RM 1144 A 0.0- 6.0 bar 0.172 bar absol. pressure meas. Drywell 2 / DW2 2
MP.EN RM 3051 CA2 0.0- 1.5 bar 0.011 bar absol. pressure meas. Environment 338 MP.GD RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. GDCS tank / GDCS 218 MP.MS1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW1 219 MP.MS2 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW2 344 MP.P1 F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Feed DW1->PCC1 341 MP.P1V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Vent PCC1->SC1 557 MP.P2F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol, pressure meas. PCC2 Feed DW2->PCC2 342 MP.P2V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Vent PCC2->SC2 558 MP.P3F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Feed DW2->PCC3 343 MP.P3V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Vent PCC3->SC2 554 MP.RP.1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Reactor Pressure Vessel / RPV 58 MP.RP.2 RM 2088 A3 0.0-13.0 bar 0.293 bar absol. pressure meas. Reactor Pressure Vessel / RPV 2{ - gg1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Suppression Chamber 1/ SC1 222 MP.S2 RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. Suppression Chamber 2 / SC2 435 MPG.01.1 Li1231 02
.002-600 bar 4.0-%
air partial press. meas. Drywell 1/ DW1 4[7 MPG.DI.
Lb3102
.002-600 bar 4.0 %
air partial press. meas. Drywell 1/ DW1
ALPliA-615-0 / Page 39 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 439 MPG.D2.1 Li1231 02
.002-600 bar 4.0 %
air partial press. meas. Drywell 2 / DW2 441 MPG.D2.2 Li 123102
.002-600 bar 4.0 %
air partial press. meas. Drywell 2 / DW2 375 MPG.S1 Li 123102
.002-600 bar 4.0 %
air partial press. meas. Suppression Chamber 1/ SC1 377 MPG.S2 LI 123102
.002-600 bar 4.0 %
air partial press. meas. Suppression Chamber 2 / SC2 482 MTF.GD.1 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 480 MTF.GD.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 479 MT F.GD.3 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas.' GDCS tank / GDCS 478 MTF.GD.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 477 MTF.GD.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 476 MTF.GD.6 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 475 MT F.GD.7 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 336 MTF.RP.1 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 335 MTF.RP.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 334 MTF.RP.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas: Reactor Pressure Vessel / RPV i
I 96 MTF.RP.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 95 MTF.RP.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 474 M TG.D I.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 473 MTG D1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 472 MTG.D1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 471 M T G.D I.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 470 M TG.D 1.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 469 M TG.D I.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 m
m.
m
ALPHA-615-0 / Page 40 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 467 MTG.D2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 466 MTG.D2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 l
465 MTG.D2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 464 MTG.D2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 463 M TG.D2.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 462 MTG.D2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 717 MTG.GP1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 716 MTG.GP1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 L
715 MTG.GP2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2
[
714 M TG.GP2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 l
713 M TG.ll.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas.1C Condenser
(
712 M T G.11.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 711 M TG.11.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 710 M1 G.11.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 709 M TG.ll.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 708 MTG.11.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 707 MTG.11.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser t
706 MTG.ll.8 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 705 MTG.11.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 571 M TG.11 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. IC Feed RPV->lC 459 MTG 11F.2 PSITC 1.0-196.58 C 0.8 'C gas temp. meas. IC Feed RPV->lC 704 MTG 11F.3 PSITC 1.0-196.58 C O.8 C gas temp. meas. IC Feed RPV->lC
ALPHA-615-0 / Page 41 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 237 MTG MSI.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW1 458 MTG MSt.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 456 MTG.MSI.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 238 MTG.MS2.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW2 455 MTG.MS2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam kne RPV->DW2 454-MTG.MS2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam kne RPV->DW2 287 MTG.MV1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1-> SCI 333 MTG.MV1.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 216 MTG.MV1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 215 MTG.MV1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent hne DW1->SC1 286 MTG.MV2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 332 MTG.MV2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent hne DW2->SC2 214 MTG.MV2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 213 MTG.MV2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent hne DW2->SC2 703 MTG.P 1.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 702 MTG.P1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 701 M TG.P 1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 700 MTG.P1.4 PSITC 1.0-196.58 C 0_8 C gas temp. meas. PCC1 Condenser 699 MTG.P 1.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCCI Condenser 698 MTG.P1.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 696 MTG.Pl.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 695 M TG P1.8 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser
.m m.
u u.m
ALPtiA-615-0 / Page 42 l
Table A.1: M3A Data identification contd.
DACHANNEL PflOCESSID TYPE F1ANGE/ UNIT ACCURACY LOCATION 694 M TG P1.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 572 MTG.P1 F.1 llB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC1 Feed DW1->PCC1 693 MTG P1F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Feed DW1->PCC1 365 MTG.P1V.1 FIB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC1 Vent PCC1->SC1 692 M TG.P1V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 331 MTG.P1V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 212 MTG.P 1V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1-> SCI 211 MTG.P1V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1-> SCI 691 MTG.P2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 690 MTG.P2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 689 MTG.P2.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 688 MTG.P2.4 PSI TC 1.0-196.58 C 0.8 C gas iemp. meas. PCC2 Condenser 687 MTG P2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 686 MTG P2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 685 MTG P2.7 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 684 MTG.P2.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 683 MTG.P2.9 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 573 MTG.P2F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC2 Feed DW2->PCC2 682 MTG.P2F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Feed DW2->PCC2 366 M TG.P2V.1 tiB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC2 Vent PCC2->SC2 681 MTG.P2V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 330 MTG P2V.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2
ALPliA-615-0 / Page 43 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 210 M IG.P2V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 209 M TG.P2V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 528 MTG.P3.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 527 MTG.P3.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 526 MT G.P3.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 525 MTG.P3.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 524 MTG.P3.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 523 MTG.P3.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 522 MTG.P3.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 521 MTG.P3.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 520 MTG.P3.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 574 MTG.P3F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC3 Feed DW2->PCC3 680 MTG.P3F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Feed DW2->PCC3 367 MTG.P3V.1 118 Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC3 Vent PCC3->SC2 679 MTG.P3V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 329 M I'G.P3V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 208 MTG P3V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 207 MTG P3V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 206 MTG.S t.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 205 M TG.SI.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 204 M TG.S t.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 203 MTG.St.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SCI
ALP}lA-615-0 / Page 44 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 202 MTG.St.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 201 M TG.S I.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 199 MTG.S2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 198 MTG.S2.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2
[
197 Mi G.S2.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 196 MTG.S2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 195 MTG.S2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 194 MT G.S2.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 449 MTG.TDO.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 448 MTG.TDO.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 447 M TG.T DO.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 328 MTG.TSU.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SCI-SC2 Upper connection 327 MTG.TSU.2 PSITC 10-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 326 MTG.TSU.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection j
325 MTG.VB l.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 324 M TG.VB1.2 PSITC 1.0-196.58 C 0.3 C gas temp. meas. Vacuum Breaker SC1-DW1
[
446 MTG.VB1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SCI-DWI 445 MTG.VB1.4 PSITC 1.0-196.58 C 08C gas temp. meas. Vacuum Breaker SC1-DW1 i
323 MTG.VB2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 322 MTG.VB2.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 444 M TG.VB2.3 PSITC 1.0-196.58 C 0.8 0 gas temp. meas. Vacuum Breaker SC2-DW2 j
PSIT{
1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 443 MTG.VB2.4 I
ALPliA-615-0 / Page 45 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 283 MTI.D I.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 282 MTI.D1.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 281 MTl DI.3 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DWI 280 MTI.D t.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 279 MTI.DI.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 278 MTI.D1.6 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 277 MTI.D1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 276 MTI.D I.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 275 MTI.D 1.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 274 MTI.D2.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2
-273 MTI.D2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 272 MTI.D2.3 PSI TC 1.0-196.58 C O.8 C inside wall temp. meas. Drywell 2 / DW2 271 MTI.D2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 270 MTl D2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 269 MTl D2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 268 MTI.D2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 267 MTI.D2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 266 MTI.D2.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 263 MTI.GD.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 262 MTI.GD.2 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 261 M TI.GO.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 260 M TI.GD.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS
4 ALPliA-615-0 / Page 46 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGEMNIT ACCURACY LOCATION 259 M TI.GD.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 258 MTI.GD.6 PSITC 1.0-196.58 C 0.8 C iaside wall temp. meas. GDCS tank / GDCS 244 M TI.R P.1 PSITC 1.0-196.58 C 0.8 C indle wall temp. meas. Reactor Pressure Vessel / RPV 243 MTI.RP.2 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 242 M Tl.RP.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 191 M TI.S I.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 190 M Tl.S I.2 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 189 MTI.S I.3 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 188 MTI.S t.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 187 m ii.S t 5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 186 MTI.S t.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 185 M TI.S 1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 184 M Tl.SI.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 183 MTI.S t.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 182 MTI.S2.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 181 MTI.S2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 180 MTI.S2.3 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 179 MTI.S2.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 178 MTI.S2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas Suppression Chamber 2 / SC2 177 MTI.S2.6 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 176 M Tl.S2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 175 M TI.S2.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2
(
_..___..._...,__.m_.m.
... _.. _.... -. _. --.._~~._,-__
l i
i ALPHA-615-0 / Page 47 Table A.1: M3A Data identification contd.
[
t DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION
[
i 174 M TI.S2.9 PSI TC 1.0-196.58 C.
0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2
[
14 MTL. EGO HB Pt100 0.0-200.00 C 0.4 C hquid temp, meas. Equalization line common branch f
15 MTL.GRT.1 HB Pt100 0.0-200.00 C 0.2 C liquid temp. meas. Condensate Return GDCS->RPV f
88 MTL.GRT.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Retum GDCS->RPV 317 MTL.GRT.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Return GDCS->RPV
[
4 674 MTL.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condenser t
16 MTL.11C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. IC Condensate IC->RPV I
672 MTL.11 C.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV P
173 MTL.11 C.3 PSITC 1.0-196.58 C 0.8 C hquid temp. mens. IC Condensate IC->RPV 671 MTL.P1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condenser f
234 MTL.PiC.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC1 Condensate PCC1->GDCS j
670 MT L.P I C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condensate PCC1->GDCS
(
669 MT L.P2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condenser f
235 MTL.P2C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 668 MTL.P2C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 519 MTL:P3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condenser 236 MTL.P3C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 667 MTL.P3C.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 8G MTL.RP.1 PSITC 1.0-196.58 C 0.8 C hquid temp. meas. Reactor Pressure Vessel / RPV 85 M TL.RP.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 172 M TL.S I.1 PSITC
~ 1.0-196.58 C 0.8 C '
liquid temp. meas. Suppression Chamber 1/ SCI 171 MTL.S t.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SCI
?
i ALPHA-615-0 / Page 48 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 170 M T L.S I.3 PSI TC 1.0-196.58 C 0.8 C hquid temp. meas. Suppression Chamber 1/ SC1 168 MT L.S t.4 PSITC 1.0-196.58 C 0.8 C hquid temp. meas. Suppression Chamber 1/ SC1 167 MTL.SI.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chan.ber 1/ SC1 166 MTL.SI.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 165 MTL.S2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 164 MTL.S2.2 PSITC 1.0-196.58 C 0.8 C hquid temp. meas. Suppression Chamber 2 / SC2 163 MTL.S2.3 PSI TC 1.0-196.58 C 0.8 C hquid temp. meas. Suppression Chamber 2 / SC2 f
162 MTL.S2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 l
161 MTL.S2.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 i
160 MTL.S2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 f
159 MTL.TSL.1 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection I
158 MTL.TSL.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 157 MTL.TSL.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SCI-SC2 Lower connection 432 MTL.UO.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 431 MTL.UO.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 430 MTL UO.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 429 MTL.UO.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 428 MTL.UO.5 PSITC 1.0-196.58 C 0.8 C hquid temp. meas. IC pool 427 MTL.UO.6 PSITC 1.0-196.58 C 0.8 C liquid temp. rr.cas. IC pool 426 MTL.UO.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 659 M TL.UOL PSITC 1.0-196.58 C 0.8'C liquid temp. meas. AWS. Low Bus IC connection 657 M TL.U I.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool
t l
ALPilA-615-0 / Page 49 I
Table A.1: M3A Data identification contd.
t DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 656 M TL.U 1.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCCI pool 655 MTL.U 1.3 PSITC 1.0-196 58 C 0.8 C liquid temp. meas. PCCI pool 654 MTL.U I.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 653 M TL.U 1.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCCI pool i
652 MTL.U 1.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool l
651 M TL.U I.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 650 MTL.UIL '
PSITC 1.0-196.58 C 0.8 C liquid temp. meas. AWS: Low Bus PCCI connection 647 MTL.U2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 646 MTL.U2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 645 M TL.U2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 644 MTL.U2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 643 MTL.U2.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 642 MTL.U2.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 641 MTL.U2.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 640 MTL.U2L PSITC 1.0-196.58 C 0.8 C liquid temp. meas. AWS: Low Bus PCC2 connection 518 MTL.U3.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 517 MTLU3.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 516 MTL.U3.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 515 MTL.U3.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 514 MTL.U3.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 513 M1 L.U3.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 512 M T L.U3.7 PSITC 1.0-196.58 C 0.8 C liquid terap. meas. PCC3 pool
ALPH A-615-0 / Page 50 l
t Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION l
511 MT L.U3.8 PSI TC 1.0-196.58 C 0.8 C hquid temp. meas. PCC3 pool 510 MT L.U3.9 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 509 MTL.U3.10 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool
}
508 MTL.U3.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 507 MTL.U3.12 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 506 MTL.U3.13 PSITC 1.0-196.58 C 0.8 C hquid temp. meas. PCC3 pool l
504 MTL.U3.14 PSITC 1.0-196.58 C O.8 C hquid temp. meas. PCC3 pool 503 MTL.U3.15 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 502 MTL.U3.16 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 501 MTL.U3.17 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 500 MTL.U3.18 PSITC 1.0-196.58 C 0.8 C hquid temp. meas. PCC3 pool 499 MTL.U3.19 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 638 MTL.U3L PSITC 1.0-196.58 C 0.8 C hquid temp. meas. AWS: Low Bus PCC3 connection 636-M TO.D 1.1 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 635 MTO.D I.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 i
634 M TO.D I.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 254 MTO.DI.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 -
253 MTO.DI.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 252 MTO.D1.6 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 315 MI'O.D1.7 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 314 MTO D1.8 PSITC 1.0-196.58 C 0.8 'C outside wall temp. meas. Drywell 1/ DW1 312 MTO.D1.9 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1
~ -
ALPilA-615-0 / Page 51 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 633 M TO.D2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 632 MTO.D2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 631 MTO.D2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 257 MTO.D2.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 256 MTO.D2.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 255 MTO.D2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 311 MTO.D2.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 310 MTO.D2.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 309 M TO.D2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 251 MTO.GD.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 250 MTO.GD.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 249 MTO.GD.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 248 M TO.GD.4 PSITC 1.0-196.58 C -
0.8 C outside wall temp. meas. GDCS tank / GDCS 247 MTO.GD.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 246 MTO.GD.6 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 308 MTO.S1.1 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 307 MTO.SI.2 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 306 M TO.S t.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 156 M1O St.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber t / SCI 155 MTO.St.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 154 MTO.S t.6 PSI TC 1.0-196.58 C 0.8'C outside wall temp. meas. Suppression Chamber 1/ SCI 80 M T O.S t.7 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 -
~.
I t
ALPHA-615-0 / Page 52 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 79 M TO.S1.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 78 MTO.S t.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 305 MTO.S2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 304 M TO.S2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 303 MTO.S2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 153 MTO.S2.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 152 MTO.S2.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chambei 2 / SC2 151 MTO.S2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 77 MTO.S2.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 76 -
MTO.S2.8 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 75 MTO.S2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 434 MT P.D 1.1 Ll TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 1/ DW1 436 M TP.D1.2 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 1/ DW1 l
438 MTP.D2.1 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 2 / DW2 440 MTP.D2.2 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 2 / DW2 374 MTP.S1 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Suppression Chamber 1/ SC1 376 MTP.S2 Ll TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Suppression Chamber 2 / SC2 408 M TS.D I.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 407 MTS.D I.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 406 MTS.01.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 405 MTS.D2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 404 MTS.D2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2
ALPHA-615-0 / Page 53 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 403 MTS.D2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 402 MTS.GD.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 401 MTS.GD.2 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 400 MTS.GD.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 150 MTS.S t.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SCI 149 MTS.S t.2 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 148 MTS.S t.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 147 MTS.S2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 146 MTS.S2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 144 MTS.S2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 425 MIT.11.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 424 MTT.11.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 423 MTT.11.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 422 MTT.11.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 421 MTT.11.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 420 MTT.11.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 419 MTT.11.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 418 MTT.11.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 417 MIT.11.9 PSI TC 1.0-196.58 C.
0.8 C tube wall temp. meas. IC Condenser 416 M TT.11.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 415 MTT.11.11 PSITC 1.0-196.58 C 0.8'C tube wall temp. meas. IC Condenser 414 MTT.11.12 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser
ALPHA-615-0 / Page 54 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 413 MTT.11.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 412 MTT.11.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 411 MTT.11.15 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 410 MTT.11.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 613 MTT.P 1.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 612 MTT.P 1.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 611 MTT.P1 3 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCCI Condenser 610 MIT.P 1.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. FCC1 Condenser 609 MTT.P1.5 PSITC 1.0-196.58 C 0.8 C tube wall temp meas. PCC1 Condenser 608 M TT.P1.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 607 MTT.P 1.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 606 M TT.P 1.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 605 MTT.P 1.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 604 M TT.P 1.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 603 MTT.P 1.11 -
PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 602 MTT.P1.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 600 MTT.P1.13 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 599 MTT.P1.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 598 MTT.P1.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 597 MTT.P1.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 630 MTT.P2.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 629 MTT.P2.2 PSITC 1.0-196.58 C 0.8 C tube wall ternp. meas. PCC2 Condenser
ALPHA-615-0 / Page 55 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION I
628 MTT.P2.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 627 MTT.P2.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Cond]ser 626 MT T.P2.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Ccndenser 624 MTT.P2.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 623 MTT.P2.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 622 MTT.P2.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 621 MTT.P2.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 620 MTT.P2.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 619 MTT.P2.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 618 MTT.P2.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 617 MTT.P2.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 616 M TT.P2.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 615 MTT.P2.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 614 MTT.P2.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 498 MTT.P3.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 497 MTT.P3.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 496 MTT.P3.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 495 MTT.P3.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas.' PCC3 Condenser 494 M TT.P3.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 493 MTT.P3.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 492 M TT.P3.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 491 MTT.P3.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser
ALPHA-615-0 / Page 56 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 490 MTT.P3.9 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 489 M TT.P3.10 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 488 MTT.P3.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 487 MTT.P3.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 486 MTT.P3.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 485 MTT.P3.14 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 484 M TT.P3.15 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 483 MTT.P3.16 PSITC 1.0-196.58 C.
0.8 C tube wall temp. meas. PCC3 Condenser 569 M TV.GP1.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 568 MTV.GP l.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DWt 567 MTV.GP2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 566 MTV.GP2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 302 MTV.GRT PSITC 1.0-196.58 C 0.8 C wall temp. meas. Condensate Return GDCS->RPV 596 MTV.11 C PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Condensate IC->RPV 594 MTV.11 F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->iC 399 MTV.11 F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 595 MTV.11 F.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 397 MTV.MS t.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 398 M TV.MSI.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 q
396 MTV.MSI.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 394 MTV MS2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 395 MTV.MS2.2 PSITC 1.0-196.58 C O.8 C wall temp. meas. Main Steam line RPV->DW2
4 ALPHA-615-0 / Page 57 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 393 MTV.MS2.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 i
292 MTV.MV1.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent hne DW1->SC1 301 MTV.MV1.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent hne DW1-> SCI 140 MTV MV1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 291 MTV.MV2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 300 MTV.MV2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 141 MTV.MV2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent hne DW2->SC2 593 MTV.P1C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Condensate PCC1->GDCS 592 MTV.P 1 F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 591 MTV.P1 F.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 f
390 MTV.P1V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1-> SCI 590 MTV.P1V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 299 M TV.P1V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 137 MTV.P1V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 589 MTV.P2C PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Condensate PCC2->GDCS 588 MTV.P2F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 587 MTV.P2F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 389 MTV.P2V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 586 MTV.P2V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 298 MTV.P2V.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 138 MTV.P2V.4 PSITC 1.0-196.58 C 0.8'C wall temp. meas. PCC2 Vent PCC2->SC2 585 MTV.P3C PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Condensate PCC3->GDCS
- - ~
^
=
ALPHA-615-0 / Page 58 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE FLANGE / UNIT ACCURACY LOCATION 584 MTV.P3F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 583 MTV.P3F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 388 MTV.P3V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 582 MTV.P3V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 297 MTV.P3V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 139 MTV.P3V.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 296 MTV.VB1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas Vacuum Breaker SC1-DW1 294 MTV.VB1.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 382 MTV.VB1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 384 MTV.VB1.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SCI-DW1 295 MTV.VB2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 293 MTV.VB2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 379 MTV.VB2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 381 MTV.VB2.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 118 MV.GRT I USON 994 449-2722 g/s 2.0 %
volume flow meas. Condensate Retum GDCS->RPV 358 MV.MSI I VORTEX 100 135-595 g/s 1.5 %
volume flow meas. Main Steam line RPV->DW1 359 MV.MS2 i VORTEX 100 134-592 g/s 1.5 %
volume flow meas. Main Steam line RPV->DW2 562 MV.P1 F i VORTEX 80 72-311 g/s 1.5 %
volume flow meas. PCC1 Feed DW1->PCC1 352 MV.P 1 V I VORTEX 80 68-262 g/s 2.0 %
volume flow meas. PCC1 Vent PCC1->SC1 563 MV.P2F 1 VORTEX 80 73-327 g/s 1.5 %
volume flow meas. PCC2 Feed DW2->PCC2 353 MV.P2V I VORTEX 80 62-259 g/s 2.6 %
volume flow meas. PCC2 Vent PCC2->SC2 116 MV.P3C 1 USON 994 53-387 g/s 2.0 %
volume flow meas. PCC3 Condensate PCC3->GDCS
R ALPHA-615-0 / Page 59 Table A.1: M3A Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 564 MV.P3F i VORTEX 80 71-342 g/s 1.5 %
volume flow meas. PCC3 Feed DW2->PCC3 354 MV.P3V I VORTEX 80 63-263 g/s 2.0 %
volume flow meas. PCC3 Vent PCC3->SC2 42 MW.RP.1 CBSYNEAX 0 - 50 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 43 MW.R P.2 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 44 MW.RP.3 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 45 MW.RP.4 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 46 MW.RP.5 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 47 MW.RP.6 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 48 MW.RP.7 HB TZA4 TOT 0 - 1500 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV A Total of 515 Data Records
.