PAUL SCHERRER INSTITUT MJamZ W Document No.

ALPHA-616 Document Title PANDA Transient Tests M3B Integral System Test Data Transmittal Report Revision Status Approval / Date Rev.

Prepared / Revised by P-PM G-PM G SQR issue Date

. Remarks ek G.

gate 2 July 96

=I on O

M. Huggenberger k

Jf9 aL609 docm2 o7.1996 7

9608200165 960816 PDR ADOCK 05200004 A

PDR

ALPHA 616 / Saite 2 Controlled Copy (CC) Distribution List Note: Standard distribution (cf. next page) is non-controlled CC Holder CC List Entry Return / Recall No, Name, Affiliation Date Date e

l

Registrie'ung

~

~

~

T PAUL SCHERRER INSTITUT y42 9 ;6 0 g 6 PANDA Transient Tests Ersetzt Titel M3B Integral System Test Data Transmittal Report Erse Autoren/

M. Huggenberger, C. Aubert, J. Dreier. O. Fischer, Autonnnen S. Lomperski, H.J. Strassberger

27. June 1996 Summary:

This Data Transmittal Report (DTR) summarizes the results of the PANDA transient system test M3B which is a simulation of a break in the main steam line of the SBWR. The test was conducted witt nominal initial conditions, similar to those calculated for the SBWR under SSAR assumptions at one hour into the LOCA. One-half of the steam flow from the RPV was directed to drywell 1 and the other one-half to drywell 2 (symmetric case). The objectives of the 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> test M3A are to demonstrate the repeatability of key parameters of the base case test M3 and to show the effect of PCC/lO pool configuration / refilling on global system performance.

The DTR, for test M3B toge+her with the Umbrella DTR satisfies the requirements specified in the Test Plan (TP) 25A5764 Rev 2 (GE document) section 10. The DTR includes: General description and purpose of test, test facility configuration description and a table of actual and specified initial conditions. Further, the test results are presented by time history plots over the test duration and the main observations are given.

During test M3B two vacuum breaker openings occurred. They were initiated by th,e last refilling of the interconnected PCC pools to maintain levels. Test M3A with isolated PCC pools had five VB openings. Refilling of the interconnected pools leads to less disturbances than isolated pools. As for M3A, the VB openings in M3B did not affect the global DW/WW pressure response, which followed very closely the M3 pressure curve.

The M3B test objectives have been reached.

Veneder Abt.

Empfanger/ Empfangennnen Expl Abt.

Empfinger/ Empfangennnen Expt Expl 42 G. Yadigaroglu 1

GE San Jose CA Bibktw G. Varadi 1

J.E. Torbeck 1

C. Aubert 1

(for distribution at GE to

Reserv, 5

T. Bandurski 1

J.R. Fitch, G.A. Wingate, J. Dreier 1

B.S. Shiralkar, Total 3g O. Fischer 1

DRF No. T10-0005)

J. Healzer 1

Seten 59 M. Hugg&1erger 1

Bedagen S. Lomp sski 1

H.J. Strassberger 1

in,ormatonsuste PANDA-Documentation 2

0 1l2 d4 5l8l9 A

Visum AbtAaborteaung:

d ALPHA-616-0 / Page 4 i

i 1

Contents

1. INTP.ODUCTION 5

1.1 General Description and Purpose of Test 5

1.2 Purpose of Report 5

^

2. TEST OBJECTIVES 5

l 2.1 General Objectives 5

2.2 Specific Objectives 6

3. TEST FACILITY CONFIGURATION AND INITIAL CONDITIONS

~

6 3.1 Test Facility Configuration 6

3.2 Test initial Conditions 6

4. TEST RESULTS 12 4.1 Main Observations 12 4.2 Time History Plots 13
5. CONCLUSIONS 33 5.1 Adequacy of Test Data 33 5.2 Applicability to Test Objectives 33
6. REFERENCE DOCUMENTS 34 APPENDIX: COMPOSITION OF DATA RECORDS 35

.+

ALPHA 616-0 / Page 5 i

1. Introduction

)

1.1 General Description and Purpose of Test Test M3B is a repetition of the base case test M3. Additionally, the effect of hydraulically interconnected PCC/IC pools and the influence of periodically pool refilling on the global system

)

performance were investigated. M3B is a simulation of a break in the main steam line of the SBWR. The nominal initial containment conditions were similar to those calculated for the SBWR under SSAR assumptions at one hour into the LOCA. The initial drywell pressure was approximately 300 kPa. One-half of the steam from the RPV was directed to DW1 which feeds one PCC condenser, and the other one-half of the steam was directed to DW2 with two PCC i

condensers connected. This was achieved with separate blowdown lines from the RPV to each of the two drywells. The two blowdcwn lines have essentially equal flow resistances. These test conditions represent a symmetrical situation in the PANDA facility. This test provides data for comparison with tests M3 (base case) and M3A (repeatability and effect of PCC/IC pool configuration).

1.2 Purpose of Report This Data Transmittal Report (DTR) is compiled in accordance with the requirements specified in j

Test Plan (TP) 25A5764 Rev 2 (GE document) Section 10 (1]. The report covers the results for the transient integral system test M3B which has been run in accordance with the test procedure desenbed in [2]. The DTR provides detailed information about test objectives, the test facility configuration and the test initial conditions. The test results main observations are reported and a number of plots, which support the findings are included. The conclusions about the adequacy of test data and the applicability of test objectives are given. The composition of the data record is desenbed in an Appendix. The general information about the overall test program, the PANDA facility, the instrumentation, the data acquisition system, the facility characterization tests, the PANDA experimental data base and the error analysis is described in the DTR umbrella report

[4]. The apparent test results for test M3B are summarized in (3].

2. Test Objectives 2.1 General Objectives The objectives of the PANDA integral system tests are to provide additional data to: a) confirm the capability of TRACG to predict SBWR containment system performance, including potential systems interaction effects (Integral System Tests) and b) demonstrate startup ar'd long-term operation of a passive containment cooling system (Concept Demonstration).

ALPHA-616-0 / Page 6 2.2 Specific Objectives The specific objectives of test M3B which was conducted with nominal post-LOCA conditions one hour after a Main Steam Line Break are:

- To demonstrate transient system response and repeatability of key parameters of the base case test M3.

- To show the effect of PCC/lC pool configuration and periodically pool refilling on the global PCC system behaviour.

3. Test Facility Configuration and initial Conditions 3.1 Test Facility Configuration The PANDA test facility is described in detail in Section 3 of PSI report ALPHA-606 [4]. For test M3B the PANDA facility was configured to simulate the SBWR post-LOCA configuration as follows:
1) The RPV supplies steam to each drywell with two steam lines (one to each drywell). These two steam lines have the same pressure loss characteristics and, therefore, allow for sytT1 metric injection of steam into the two drywells.
2) RPV heater power is controlled as a function of time to simulate the scaled decay heat and stored energy release (as specified in [1]).
3) The IC unit is isolated by closing the inlet and outlet valves (i.e., the IC feed, drain and vent lines are closed).
4) All three PCC units are lined-up to take feedflow from the drywells, to vent noncondensables and steam into the water volume of the suppression pool, and drain condensate to the GDCS volume.
5) The three PCC pools and the IC pool are interconnected at the bottom. During the test, water is added to the pools (with a flow rate of approximately 2 kg/s) via the auxiliary water system as needed, from the bottom to maintain level.
6) The only direct lines of communication between the drywell and wetwell are through the vacuum breakers (when the wetwell pressure exceeds drywell pressure sufficiently to open the vacuum breaker) and the main vent lines (which are submerged within the wetwells).
7) The GDCS pressure equalization lines to both drywells are open.
8) The GDCS drain line with check valve is lined up to return PCC condensate to the RPV.
9) The Equalizing lines between the RPV and wetwells are valved out of service.

i i

3.2 Test Initial Conditions The test initial conditions represent the state of the system one hour after scram. These conditions are presented in Table 3.1. The " Average Value" represents the arithmetic mean over the one minute measurement period just before connecting the drywells to the RPV. The

" Requested Value" is the value as it is specified in the Test Plan [1].

e n ALPHA-616-0 / Page 7

)

Table 3.1: Test M3B Initial Conditions VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value ENVIRONhENT PARANETERS Atmospheric pressure MP.EN bar Temperature of saturation for atmospheric pressure (Tsai_ry)

C RPV PARAMETERS Total pressure MP.RP.1 bar Fluid temperatures:

Spatial average Tp_-(RP)

C Local MTF.RP.1 C

MTF.RP.2 C

MTF.RP.3 C

MTF.RP.4 C

MTF.RP.5 C

Water level ML.RP.1 m

DRYWELL PARAMETERS Total pressure MP.D1 bar partial pressure MPG.DI.1 bar MPG.D!.2 bar MPG.D2.1 bar MPG.D2.2 bar Gas temperatures:

Spatial average To_m (D1)

C Local MTG.DI.1 C

MTO.DI.2 C

i MTG.Dl.3 C

MTG.D1.4.

C MTG.DI.5 C

MTG.D1.6 C

(1) The Drywell total pressures are not independant variables, they are given by temperatures and air partial pressures. The corresponding tolerance is calculated from temperature and gas partial pressure tolerances.

(2) Refer to Test Procedure on how the air partial pressure is adjusted in the DWs (not based on oxygen probe measurements, but on pressure increase during air injection).

ALPHA 616-0 / Page 8 Table 3.1: Test M3B initial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value DRYWELL PARANETERS (Cont'd)

Spatial average To.m o(D2)

C Local MTG.D2.1 C

MTG.D2.2 C

MTG.D2.3 C

MTG.D2.4 C

MTG.D2.5 C

MTG.D2.6 C

Water level ML.D1 m

ML.D2 m

SUPPRESSION CHAMBER PARAMETER' Total pressure MP.Sl bar I3) Air partial pressure MPG.S1 bar MPG.S2 bar Water temperatures:

Spatial average Tw (SI)

C Local MTL.S t.1 C

MTL.S I.2 C

MTL.S1.3 C

MTL.S I.4 C

MT1..S t.5 C

MTL.SI.6 C

Spatial average Tw m n(S2)

C Local MTL.S2.1 C

MTL.S2.2 C

MTL.S2.3 C

MTL.S2.4 C

(3) The Suppression Chamber air partial pressures are not independant variables, they are given by temperatures and total pressures. The corresponding tolerance is calculated from temperature and total pressure tolerances.

ALPHA-616-0 / Page 9 Table 3.1: Test M3B initial Conditions Contd.

I VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value SUPPRESSION CHAMBER PARAMETERS (Cont'd)

Water Temperatures:

Local MTL.S2.5 C

MTL.S2.6 C

Gas temperatures:

Spatial average To, mon (SI)

C Local MTG.SI.1 C

MTG.51.2 C

MTG.SI.3 C

MTG.S I.4 C

MTG.51.5 C

MTG.51.6 C

Spatial average To, mon (S2)

C Local MTG.S2.1 C

MTG.S2.2 C

MTG.S2.3 C

MTG.S2.4 C

MTG.S2.5 C

MTG.S2.6 C

Water level M L.S1 m

ML.S2 m

GDCS PARAMETERS l

Total pressure MP.GD bar Fluid temperatures:

Spatial average Tr on(GD)

C Local MTF.GD.1 C

MTF.GD.2 C

MTF.GD.3 C

MTF.GD.4 C

l l-

ALPHA-616-0 / Page 10 l.

s l

Table 3.1: Test M3B Initial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value GDCS PARAMETERS (Cont'd) t MTF.GD.5 C

MTF.GD.6 C

M7F.GD.7 C

Water level ML.GD m

i 1

PCC1 POOL PARAhETERS Water tergeratures:

Spatial average Tw n (U1)

C Lceal MTL.U1.1 C

MTL.U1.2 C

MTL.UI.3 C

]

MTL.UI.4 C

MTL.UI.5 C

MTL.UI.6 C

MTL.U1.7 C

Waterlevel ML.U1 m

1 PCC2 POOL PARAMETERS Water temperatures:

Spatial average Tw (U2)

C Local hflL.U2.1 C

MTL U2.2 C

MTL U2.3 C

MTL.U2.4 C

MTL.U2.5 C

MIL.U2.6 C

MTL.U2.7 C

Waterlevel ML.U2 m

~.. - -..

l ALPHA-616-0 / Page 11

[

t I

Table 3.1: Test M3B initial Conditions Contd.

VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value i

i PCC3 POOL PARAMETERS Water temperatures:

Spatial average Tw n(U3)

C Local MTL.U3.1 C

r MTL.U3.2 C

ME.U3.3 C

MTL U3.4 C

f MTL.U3.5 C

MTL.U3.6 C

1 MTL.U3.7 C

l MIL.U3.8 C

MTL.U3.9 C

MTL.U3.10 C

MTL.U3.11 C

MTL.U3.12 C

MTL.U3.13 C

MTL.U3.14 C

MTL.U3.15 C

MTL.U3.16 C

MTL U3.17 C

MTL.U3.18 C

MTL.U3.19 C

Waterlevel ML.U3 m

List of Deviations from Requested initial Conditions:

Air partial pressure in both Drywells All deviations listed above are minor and they did not affect the test results (cf. [3]).

ALPHA-616-0 / Page 12

4. Test Results The main observations for the test M3B are presented in Section 4.1. A standard set of time history plots for the key parameters and additional plots which support the individual test observations are given in Section 4.2.

4.1 Main Observations

ALPHA-616-0 / PagG 13 4.2 Time History Plots Time history plots are provided to support the observations discussed in Section 4.1 for the following parameters:

Figure j

i RPV, Drywell and Wetwell Pressures 1

i PCC Feed Mass Flow Rates 2

PCC1 Temperatures 3

PCC2 Temperatures 4

PCC3 Temperatures 5

PCC Vent Phase Detectors 6

PCC Vent Line Gas Temperatures 7

Drywell Air Partial Pressures 8

i Wetwell Air Partial Pressures 9

i

ALPHA-616-0 / Page 14 Figure PCC Pool Levels

.10 RPV Heater Power 11 RPV and Drywell Temperatures 12 Wetwell Gas and Water Temperatures 13 Main Steam Line Mass Flow Rates 14 Vacuum Breaker 1 Position 15 Vacuum Breaker 1 Line Temperatures 16 PCC Pool Temperatures

-17 GDCS Return Line Temperature 18 The identification code for the process variables used in the plots is explained in the DTR Umbrella Report, Section 4 (4]. Also, the DAS channel, type, range, accuracy and location of each instrument are given in the Appendix " Composition of Data Records'.

l l

1 7

~........ -

i I

f ALPHA-616-0 / Pages 15 through 32 l

?

j These pages have been deleted from this nonpropnetary version of this report, because Figures I through 18 which~are on these pages in the proprietary version of the report contain proprietary information.

l 1

l i

i e

.1 i

1 l

I I

(

l l

I-I l

l l

ALPHA-616-0 / Pa9e 33

5. Conclusions 5.1 Adequacy of Test Data The integral system test M3B has provided data of the overall system behaviour in an adequate manner. Based on the analysis of the test data [3] the test acceptance enteria have clearly been reached. All zero and instrument checks for test M3B have been successfully completed and the instrument readings were within the permitted ranges.

5.2 Applicability to Test Objectives The test objectives as statec in Section 2 of this report have been reached:

  • A comparison of the data from all the M3 series tests (M3, M3A and M38) showed generally the same overall system behaviour.
  • The PCC/IC pool configuration for test M3B (interconnected pools) and the periodically refilling of the pools lead to two vacuum breaker openings throughout the test, but this did not affect the global system performance.
  • Refilling of interconnected PCC/IC pools (test M3B) lead to less disturbances than isolated pools (test M3A).
  • Repeatability has successfully been demonstrated.

i i

4

ALPHA-616-0 / Page 34 4

i i

i

6. Reference Documents j

i i

{1)

" PANDA Test Plan Tests M3, M3A, M3B, M4, M7" (Specification), GE Document 25A5764 Rev. 2, Oct 16,1995.

l l

[2]

' PANDA Transient Tests: M3A, M3B & M4 Integral System Test Procedure", PSI internal Report ALPHA 520-2, Oct 24,1995.

[3]

' PANDA Transient Tests: M3B integral System Test Apparent Test Results", PSI Internal i

Report ALPHA-605-0, April 11,1996, Proprietary Information.

(4) ' " PANDA Facility, Test Program and Data Base General Desenption (DTR Umbrella Report) ",

i PSI internal Report ALPHA-606-0, May 31,1996.

[5]

"SBWR Test and Analysis Program Description" TAPD Licensing Topical Report, GE Report NEDC 32391P Rev. C, August 1995, GE Proprietary information.

~

1 F

l I

i l

l

ALPHA-616-0 / Pags 35 Appendix: Composition of Data Records Data Transfer for PANDA Test M3B All variables given by the Table A.1 are contained in four ORACLE tables:

GE_ PANDA _M3B_MT_LINE 37082 rows GE_ PANDA _M3B _MT_ POOL 37082 rows GE_ PANDA _M3B _MT_ VESSEL 37082 rows GE_ PANDA _M3B _M_OTHER 37082 rows All contain the variable called REC _ID (record ideritifier) allowing to link records to corresponding time.

Time data are given in the table:

G E_PAND A_M38_M_ TIME 37082 rows The structure of all these tables is exactly the same as the one described in the DTR umbrella report (4] for corresponding tables labeled without "GE_"

(PANDA _M3B_..

instead of GE_ PANDA _M38...); new table names have been used because of database consistencyl All these tables are owned by the user "aubert' and have been created in the tablespace

' USERS *; they have been exported in file 'M3B_GE_ tables.dmp'.

Measurements with restricted use MV.P3C only qualitative use possible (for example oscillations etc.) absolute value is not reliable MV.GRT only qualitative use possible (for example oscillations etc.) absolute value is not reliable

]-

MV.P1V MV.P2V during whole test below lower flow limit MV.P3V MV.MS1 below lower flow limit (cf. Figure 14)

MV.MS2 MV.P1F MV.P2F temporary below lower flow limit (cf. Figure 2)

MV.P3F

1 ALPHA-616-0 / Page 36 Table A.1: M3B Data identification DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 230 CB.VB1 KEY.NOR.AUT 0,50 or 100%

On/Off valve Vacuum Breaker SCI-DW1 231 CB.VB2 KEY.NOR.AUT 0,50 or 100%

On/Off valve Vacuum Breaker SC2-DW2 105 MD.GRT RM 1151 DPS

-36.- 150. kPa 1.68 kPa pressure diff. meas. Condensate Return GDCS->RPV 530 MD.MS1 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW1 531 MD.MS2 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW2 98 MD.MV1 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW1->SC1 99 MD.MV2 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW2->SC2 537 MD.P1 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. men. PCC1 Condenser 540 MD.P1C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC1 Condensate PCC1->GDCS 533 MD.P1F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC1 Feed DW1->PCC1 544 MD.P1V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCCI Vent PCC1-> SCI 101 MD.P1V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC1 Vent PCC1->SC1 538 MD.P2 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC2 Condenser 541 MD.P2C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC2 Condensate PCC2->GDCS 534 MD.P2F RM 3051 CD2 0.- 30. kPa,

0.26 kPa pressure diff. meas. PCC2 Feed DW2->PCC2 545 MD.P2V.1 RM 1151 DP4

-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 102 MD.P2V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 539 MD.P3 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC3 Condenser 542 MD.P3C RM 3051 CD2 0.- 30 kPa 0.25 kPa pressure diff. meas. PCC3 Condensate PCC3->GDCS 535 MD.P3F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC3 Feed DW2->PCC3 546 MD.P3V.1 RM 1151 DP4

-15.- 22. kPa 0.34'kPa pressure diff. meas. PCC3 Vent PCC3->SC2 103 MD.P3V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC3 Vent PCC3->SC2

i ALPHA-616-0 / Page 37 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 224 MD.VB1 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC1-DW1 225 MD.VB2 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC2-DW2 36 ME.RP EH MYCOM 0 - 200 pS/cm 0.5 %

water quality meas. Reactor Pressure Vessel / RPV 70 MI.MV1 PSI /GA COND 0 or 1 phase indicator Main Vent line DW1->SC1 t

71 MI.MV2 PSI /GA COND 0 or 1 phase indicator Main Vent line DW2->SC2 67 MI.P 1V.1 PSI /GA COND 0 or 1 phase indicator PCC1 Vent PCC1->SC1 68 Ml.P2V.1 PSl/GA COND 0 or 1 phase indicator PCC2 Vent PCC2->SC2 69 Ml.P3V.1 PSI /GA COND 0 or 1 phase indicator PCC3 Vent PCC3->SC2 227 ML.D1 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 1/ DW1 t

228 ML.D2 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 2 / DW2 229 ML.GD RM 3051 CD3 0-6.3 m 0.070 m level meas. GDCS tank / GDCS 113 MLMS1 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW1 114 ML.MS2 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW2 8

ML.R P.1 RM 3051 CD3 0-21.5m 0.166 m level meas. Reactor Pressure Vessel / RPV 9

ML.RP.2 RM 1151 DP5 0-4.1 m 0.157 m level meas. Reactor Pressure Vessel / RPV 107 ML.RP.3 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 108 ML.RP.4 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 226 ML.RP.5 RM 1151 DPS 0-7.7 m 0.166 m level meas. Reactor Pressure Vessel / RPV 360 ML.RP.6 RM 1151 DPS 0-4.6 m 0.158 m level meas. Reactor Pressure Vessel / RPV 110 ML.S1 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 1/ SC1 111 ML.S2 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 2 / SC2 547 ML.UO RM 1151 DPS 0-5.6 m 0.156 m level meas. IC pool

l ALPHA-616-0 / Page 38 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 548 ML.UI RM 1151 DP5 0-5.6 m 0.156 m level meas. PCC1 pool 549 ML.U2 RM 1151 DPS 0-5.6 m 0.156 m level meas. PCC2 pool 550 ML.U3 RM 1151 DPS 0-5.6 m 0.156 m level meas. PCC3 pool 72 MO.VB 0 or 1 Vacuum Breaker Trigger signal 555 MP.D1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Drywell 1/ DW1 556 MP.D2 RM 1144 A 0.0- 6.0 bar 0.172 bar absol. pressure meas. Drywell 2 / DW2 MP.EN RM 3051 CA2 0.0- 1.5 bar 0.011 bar absol. pressure meas. Environment 338 MP.GD RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. GDCS tank / GDCS 218 MP.MS1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW1 219 MP.MS2 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW2 344 MP.P1F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Feed DW1->PCC1 341 MP.P1V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Vent PCC1-> SCI 557 MP.P2F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Feed DW2->PCC2 342 MP.P2V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Vent PCC2->SC2 558 MP.P3F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Feed DW2->PCC3 343 MP.P3V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Vent PCC3->SC2 554 MP.RP.1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Reactor Pressure Vessel / RPV 58 MP.RP.2 RM 2088 A3 0.0-13.0 bar 0.293 bar absol. pressure meas. Reactor Pressure Vessel / RPV 221 MP.S1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Suppression Chamber 1/ SCI 222 MP.S2 RM 1144 A 0.0- 6.0 !:ar 0.169 bar absol. pressure meas. Suppression Chamber 2 / SC2 435 MPG.D I.1 LI1231 02

.002-600 bar 4.0 %

air partial press. meas. Drywell 1/ DW1 437 MPG.D1.2 Li 123102

.002-600 bar 4.0 %

air partial press. meas. Drywell 1/ DW1

ALPHA-616-0 / Page 39 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 439 MPG.D2.1 Li1231 02

.002-600 bar 4.0 %

air partial press. meas. Drywell 2 / DW2 375 MPG.S1 LI 123102

.002-600 bar 4.0 %

air partial press. meas. Suppression Chamber 1/ SC1 377 MPG.S2 LI 123102

.002-600 bar 4.0 %

air partial press. meas. Suppression Chamber 2 / SC2 482 MTF.GD.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 480 MTF.GD.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 479 MTF.GD.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 478 MTF.GD.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 477 MTF.GD.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 476 MTF.GD.6 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 475 MTF.GD.7 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 336 MTF.RP.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 335 MTF.RP.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 334 MTF.RP.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 96 MTF.RP.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 95 MTF.RP.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 474 MTG.D1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 473 MTG.D1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 472 MTG.D 1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 471 MTG.DI.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 470 MTG.D1.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 469 MTG.DI.6 PSITC 1.0-106.58 C 0.8 C gas temp. picas. Drywell 1/ DW1 467 MTG.D2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2

q i

ALPHA-616-0 / Page 40 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 466 MTG.D2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 465 MTG.D2.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 464 MTG.D2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 463 MTG.D2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 462 MTG.D2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 717 MTG.GP1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 716 MTG.GP1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 715 MTG.GP2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 714 MTG.GP2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 713 MTG.11.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 712 MTG.11.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 711 MTG.11.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 710 MTG.11.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 709 MTG.11.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 708 MTG.11.6 PSI TC 1.0-196.58 C

~0.8 C gas temp. meas. IC Condenser 707 MTG.11.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 706 MTG.11.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 705 MTG.11.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 571 MTG.11 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. IC Feed RPV->lC 459 MTG.11 F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 704 MTG.11 F.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 237 MTG.MS1.1 HB Pl100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam hne RPV->DW1

t ALPHA-616-0 / Page 41 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 458 MTG.MSI.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 456 MTG.MSI.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1 238 MTG.MS2.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW2 455 MTG.MS2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2 454 MTG.MS2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2 287 MTG.MV1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1-> SCI 333 MTG.MV1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 216 MTG.MV1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 215 MTG.MV1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 286 MTG.MV2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 332 MTG.MV2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 214 MTG.MV2.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 213 MTG.MV2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 703 MTG.P1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 702 MTG.P1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 701 MTG.P1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 700 MTG.P1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 699 MTG.P1.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 698 MTG.P1.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 696 MTG.P1.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 695 MTG.P1.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 694 MTG.P1.9 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser

ALPHA-616-0 / Page 42 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 572 MTG.P1 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC1 Feed DW1->PCC1 693 MTG.P1 F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Feed DW1->PCC1 365 MTG.P1V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC1 Vent PCC1->SC1 692 MTG.P1V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 331 MTG.P1V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 212 MTG.P1V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 211 MTG.P1V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 691 MTG.P2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 690 MTG.P2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 689 MTG.P2.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 688 MTG.P2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 687 MTG.P2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 686 MTG.P2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 685 MTG.P2.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 684 MTG.P2.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 683 MTG.P2.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 573 MTG.P2F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC2 Feed DW2->PCC2 682 MTG.P2F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Feed DW2->PCC2 366 MTG.P2V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC2 Vent PCC2->SC2 681 MTG.P2V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 330 MTG.P2V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 210 MTG.P2V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2

?

ALPHA-616-0 / Page 43 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 209 MTG.P2V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 528 MTG.P3.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 527 MTG.P3.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 526 MTG.P3.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 525 MTG.P3.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 524 MTG.P3.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 523 MTG.P3.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 522 MTG.P3.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 521 MTG.P3.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 520 MTG.P3.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 574 MTG.P3F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC3 Feed DW2->PCC3 683 MTG.P3F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Feed DW2->PCC3 367 MTG.P3V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC3 Vent PCC3->SC2 679 MTG.P3V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 329 MTG.P3V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 208 MTG.P3V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 207 MTG.P3V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 206 MTG.S t.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 205 MTG.S t.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 204 MTG.S1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 203 MTG.S I.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 202 MTG.S1.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SCI

ALPHA-616-0 / Page 44 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 201 MTG.SI.6 PSITC 1.0196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 199 MTG.S2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 198 MTG.S2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 197 MTG.S2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 196 MTG.S2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 195 MTG.S2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 194 MTG.S2.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 449 MTG.TDO.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 448 MTG.TDO.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 447 MTG.TDO.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 328 MTG.TSU.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 327 MTG.TSU.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 326 MTG.TSU.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 325 MTG.VB1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 324 MTG.VB1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 446 MTG.VB1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 445 MTG.VB1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 323 MTG.VB2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 322 MTG.VB2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 444 MTG.VB2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 443 MTG.VB2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 283 MTI.D1.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1

e.

ALPHA-616-0 / Page 45 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 282 MTI.D1.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 281 MTI.D1.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 280 MTI.D I.4 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 279 MTI.D1.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 278 MTI.D1.6 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 277 MTI.D1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 276 MTI.D1.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 275 MTI.D1.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 274 MTI.D2.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 273 MTI.D2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 272 MTI.D2.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 271 MTI.D2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 270 MTI.D2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 269 MTI.D2.6 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 268 MTI.D2.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 267 MTI.D2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 266 MTI.D2.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 263 M TI.G D.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 262 MTI.GD.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 261 MTI.GD.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 260 MTI.GD.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 259 MTI.GD.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS

ALPHA-616-0 / Page 46 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 258 MTI.GD.6 PSITC 1.0-196.58 C O.8 C inside wall temp. meas. GDCS tank / GDCS 244 MTI.RP.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 243 MTI.RP.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 242 MTI.RP.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 191 MTI.S t.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 190 MTI.S t.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 189 MTI.S t.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 188 MTI.S1.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 187 MTI.S1.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 186 MTI.S t.6 PSITC 1.0-196.58 C 0.8 C inside wall temp meas. Suppression Chamber 1/ SC1 185 MTI.SI.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 184 MTI.S1.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 183 MTI.S1.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. raeas. Suppression Chamber 1/ SC1 182 MTI.S2.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 181 MTI.S2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 180 MTI.S2.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 179 MTI.S2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 178 MTI.S2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 177 MTI.S2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 176 MTI.S2.7 PSITC.

1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 175 MTI.S2.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 174 MTI.S2.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2

ALPHA-616-0 / Page 47 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 1

14 MTL.EOO HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. EOualization ime common branch 15 MTLGRT.1 HB Pt100 0.0-200.00 C 0.2 C liquid temp. meas. Condensate Retum GDCS->RPV 88 MTLGRT.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Retum GDCS->RPV 317 MTL.GRT.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Retum GDCS->RPV 674 MTL.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condenser 16 MTL.11 C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. IC Condensate IC->RPV 672 MTL.11 C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV 173 MTL.11 C.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condensate IC->RPV 671 MTL.P1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condenser 234 MTL.P1C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 670 MTLPIC.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCCI Condensate PCCI->GDCS 669 MTL.P2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condenser 235 MTL.P2C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 668 MTL.P2C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 519 MTL.P3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condenser 236 MTLP3C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 667 MTL.P3C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 86 MTL.RP.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 85 MTL.RP.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 172 M1 L.S1.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SCI 171 MTL.S1.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 170 MTL.S t.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1

ALPHA-616-0 / Page 48 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 168 MTL.SI.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 16/

MTL.b1.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 166 MTL.S t.6 PSITC 1.0-196.58 C 0.8 C liquid ts mp. meas. Suppression Chamber 1/ SC1 165 MTL.S2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 164 MTL.S2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 163 MTL.S2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 162 MTL.S2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 161 MTL.S2.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 160 MTL.S2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 159 MTL.TSL.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SCI-SC2 Lower connection 158 MTL.TSL.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 157 MTL.TSL.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 432 MTLUO.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 431 MTL.UO.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC poot 430 MTL.UO.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 429 MTL.UO.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 428 MTL.UO.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 427 MTL.UO.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 426 MTL.UO.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 659 MTL.UOL PSITC.

1.0-196.58 C 0.8 C liquid temp. meas. AWS: Low Bus IC connection 657 MTL.U 1.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 656 MTL.U1.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool i

ALPHA-616-0 / Page 49 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGElUNIT ACCURACY LOCATION 655 MTLU1.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 654 MTL.U 1.4 31 TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 653 MTL.U1.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 652 MTL.U 1.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 651 MTL.UI.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 650 MTLU1L PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. AWS: Low Bus PCC1 connechon 647 MTL.U2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool

)

646 MTLU2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 645 MTL.U2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 644 MTL.U2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 643 MTLU2.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 642 MTLU2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 641 MTL.U2.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 640 MTLU2L PSITC 1.0-196.58 C 0.8 C liquid temp. meas. AWS: Low Bus PCC2 connection 518 MTL.U3.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 517 MTL.U3.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 516 MTL.U3.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 515 MTL.U3.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 514 MTL.U3.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 513 MTL.U3.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 512 MTLU3.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 511 MTL.U3.8 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool

. - _.. _ _ _ _ _. _ _ _. _. ~ _ _,... _ _ _ _ _ _ _.

ALPHA-616-0 / Page 50 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION

$10 MTL.U3.9 PSITC 1.0196.58 C 0.8 C liquid temp. meas. PCC3 pool 509 MTL.U3.10 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 508 MTL.U3.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 507 MTL.U3.12 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 506 MTL.U3.13 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 504 MTL.U3.14 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 503 MTL.U3.15 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 502 MTL.U3.16 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 501 MTL.U3.17 PSI TC 1.0-196.58 C O.8 C liquid temp. meas. PCC3 pool 500 MTLU3.18 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 499 MTL.U3.19 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 638 MTL.U3L PSITC 1.0-196.58 C 0.8 C liquid temp. meas. AWS: Low Bus PCC3 connection 636 MTO.D1.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 635 MTO.D1.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Dryw3111/ DW1 634 MTO.D1.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 254 MTO.D1.4 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 253 MTO.DI.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 252 MTO.D t.6 PStTC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 315 MTO.D1.7 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 314 MTO.D1.8 PSITC.

1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 312 MTO.D 1.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 633 MTO.D2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2

- - =

ALPHA-616-0 / Page 51 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 632 MTO.D2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 631 MTO.D2.3 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 257 MTO.D2.4 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 256 MTO.D2.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 255 MTO.D2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 311 MTO.D2.7 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 310 MTO.D2.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas.' Drywell 2 / DW2 Jo9 MTO.D2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 251 MTO.GD.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 250 MTO.GD.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 249 MTO.GD.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 248 MTO.GD.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 247 MTO.GD.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 246 MTO.GD.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 308 MTO.SI.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 307 MTO.S t.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 306 MTO.SI.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 156 MTO.S1.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 155 MTO.S1.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 154 MTO.SI.6 PSITC.

1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 80 MTO.S t.7 PSI TC 1.0-196.58 C 0.8' C outside wall temp. meas. Suppression Chamber 1/ SC1 79 MTO.S1.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1

ALPHA-616-0 / Page 52 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 78 MTO.SI.9 PStTC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 305 MTO.S2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 304 MTO.S2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 303 MTO.S2.3 PSITC 1.0-196.53 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 153 MTO.S2.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 152 MTO.S2.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 151 MTO.S2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 77 MTO.S2.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 76 MTO.S2.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 75 MTO.S2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 434 MTP.D1.1 Li TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 1/ DW1 436 MTP.D1.2 Li TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 1/ DW1 438 MTP.D2.1 LiTC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Drywell 2 / DW2 374 MTP.S1 LI TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Suppression Chamber 1/ SC1 376 MTP.S2 L1 TC 0.0-1000.0 C 0.75 %

Temp. for oxygen Probe Suppression Chamber 2 / SC2 408 MTS.D1.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 407 MTS.D1.2 PSITC 1.0-190.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 406 MTS.DI.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 405 MTS.D2.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 404 MTS.D2.2 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 403 MTS.D2.3 PSI TC 1.0-196.58 C 0.6 C pool sudace temp meas. Drywell 2 / DW2 402 MTS GD.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS

ALPHA-616-0 / Page 53 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 401 MTS.GD.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 400 MTEGiL3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 150 MTS.S1.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 149 MTS.SI.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SCI 148 MTS.S t.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 147 MTS.S2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. rneas. Suppression Chamber 2 / SC2 Suppression Chamber 2 / SC2 146 MTS.S2.2 PSITC 1.0-196.58 C 0.6 C pool surface tem-144 MTS.S2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. swas. Suppression Chamber 2 / SC2 425 MTT.11.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 424 MTT.11.2 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 423 M TT.11.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 422 MTT.11.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 421 MTT.11.5 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 420 MTT.11.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 419 MTT.11.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 418 MTT.11.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 417 MTT.11.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas iC Condenser 416 MTT.11.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 415 MTT.11.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 414 MTT.11.12 PSI TC.

1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 413 MTT.11.13 PSITC 10-196.58 C 0.8 C tube wall temp. meas. IC Condenser 412 MTT.11.14 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser

ALPHA-616-0 / Page 54 Tabie A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 411 MTT.11.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 410 MTT.11.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 613 MTT.P1.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 612 MTT.P1.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 611 MTT.P1.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 610 MTT.P1.4 PSI TC 1.0-196.58 C 0.8 C tube vall temp. meas. PCC1 Condenser 609 MTT.P1.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser l

608 MTT.P1.6 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser i

607 MTT.P1.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 606 MTT.P1.8 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 605 MTT.P1.9 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 604 MTT.P1.10 PSI TC 1.0-196.58 C O.8 C tube wall temp. meas. PCCI Condenser 603 MTT.P1.11 PSITC 1.0-196.58 C O.8 C tube wall temp. meas. PCC1 Condenser 602 MTT.P1.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 600 MTT.P1.13 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 599 MTT.P1.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 598 MTT.P1.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 597 MTT.P1.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 630 MTT.P2.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 629 MTT.P2.2 PSI TC.

1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 628 MTT.P2.3 PSITC 1.0-196.58 C 05 C tube wall temp. meas. PCC2 Condenser 627 MTT.P2.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser

ALPHA-616-0 / Page 55 f

Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 626 MTT.P2.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 624 MTT.P2.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 623 MTT.P2.7 PSITC 1.0-196.58 C 0.8 C tune wall temp. meas. PCC2 Condenser 622 MTT.P2.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 621 MTT.P2.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 620 MTT.P2.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 619 MTT.P2.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 618 MTT.P2.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 617 MTT.P2.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 616 MTT.P2.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 615 MTT.P2.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 614 MTT.P2.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 498 MTT.P3.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 497 MTT.P3.2 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 496 MTT.P3.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 495 MTT.P3.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 494 MTT.P3.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Qondenser 493 MTT.P3.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 492 MTT.P3.7 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 491 MTT.P3.8 PSITC.

1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 490 MTT.P3.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 489 MTT.P3.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser

.y ALPHA-616-0 / Page 56 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 488 MTT.P3.11 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 487 MTT.P3.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser I

486 MTT.P3.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 485 MTT.P3.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 484 MTT.P3.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 483 MTT.P3.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 569 MTV.GP1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 568 MTV.GP1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 567 MTV.GP2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 566 MTV.GP2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 302 MTV.GRT PSITC 1.0-196.58 C 0.8 C wall temp. meas. Condensate Return GDCS->RPV 596 MTV.11C PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Condensate IC->RPV 594 MTV.11 F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 399 MTV.11F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 595 MTV.11 F.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Fced RPV->lC 397 MTV.MS1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 398 MTV.MSI.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 396 MTV.MSt.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 394 MTV.MS2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 395 MTV.MS2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 393 MTV.MS2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 292 MTV.MV1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 r

ALPHA-616-0 / Page 57 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION S01 MTV.MV1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 140 MTV.MV1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1-> SCI 291 MTV.MV2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 303 MTV.MV2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 141 MTV.MV2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 593 MTV.P1C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Condensate PCC1->GDCS 592 MTV.P1 F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 591 MTV.P1 F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 390 MTV.P1V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 590 MTV.P1V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1-> SCI 299 MTV.P1V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1-> SCI 137 MTV.P1V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 589 MTV.P2C PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Condensate PCC2->GDCS 588 MTV.P2F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 587 MTV.P2F.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 389 MTV.P2V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 586 MTV.P2V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 298 MTV.P2V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 138 MTV.P2V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 585 MTV.P3C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Condensate PCC3->GDCS 584 MTV.P3F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 583 MTV.P3F.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3

ALPHA-616-0 / Page 58 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 388 MTV.P3V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 582 MTV.P3V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 297 MTV.P3V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 139 MTV.P3V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 296 MTV.VB1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 294 MTV.VB1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 382 MTV.VB1.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 384 MTV.VB1.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 295 MTV.VB2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 293 MTV.VB2.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 379 MTV.VB2.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 381 MTV.VB2.4 PSI TC 1.0-196.58 C 0.8 C wa!I temp. meas. Vacuum Breaker SC2-DW2 118 MV.GRT I USON 994 449-2722 g/s 2.0 %

volume flow meas. Condensate Return GDCS->RPV 358 MV.MS1 1 VORTEX 100 135-595 g/s 1.5 %

volume flow meas. Main Steam line RPV->DW1 359 MV.MS2 I VORTEX 100 134-592 g/s 1.5 %

volume flow meas. Main Steam line RPV->DW2 562 MV.P1 F 1 VORTEX 80 72-311 g/s 1.5 %

volume flow meas. PCC1 Feed DW1->PCC1 352 MV.P1V I VORTEX 80 68-262 g/s 2.0 %

volume flow meas. PCC1 Vent PCC1->SC1 563 MV.P2F 1 VCnTEX 80 73-327 g/s 1.5 %

volume flow meas. PCC2 Feed DW2->PCC2 353 MV.P2V I VORTEX @

62-259 g/s 2.0 %

volume flow meas. PCC2 Vent PCC2->SC2 116 MV.P3C I USON 994 53-387 g/s 2.0 %

volume flow meas. PCC3 Condensate PCC3->GDCS 564 MV.P3F 1 VORTEX 80 71-342 g/s 1.5 %

volume flow meas. PCC3 Feed DW2->PCC3 354 MV.P3V I VORTEX 80 63-263 g/s 2.0 %

volume flow meas. PCC3 Vent PCC3->SC2

ALPHA-616-0 / Page 59 Table A.1: M3B Data identification contd.

DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 42 MW.RP.1 CB SYNEAX 0 - 50 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 43 MW.RP.2 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 44 MW.RP.3 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 45 MW.RP.4 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 46 MW.RP.5 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 47 MW.RP.6 CB SYNEAX 0 - 300 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV 48 MW.RP.7 HB TZA4 TOT 0 - 1500 kW 0.6 %

electrical power meas Reactor Pressure Vessel / RPV A Total of 513 Data Records 8