Text
94 PAUL SCHERRER INSTITUT 4'
Document No.
ALPHA-617 Document Title PANDA Transient Tests M7 Integral System Test Daia Transmittal Report i
Revision Status Approval / Date Rev.
Prepared / Revised by P-PM G-PM G-SQR lssue Date
. Remarks 3,M T J. Torbeck G. Wingate 2 July 96 N. $
O M. Huggenberger 1-J}.6(a 1 July 96 1 July 96 ca.Enua p 2) a i
aL609 doc /02 07.1996 9608200166 960816 PDR ADOCK 05200004 A
ALPHA-617 / Seite 2 0*
Controlled Copy (CC) Distribution List Note: Standard distribution (cf. next page) is non-controlled CC Holder CC List Entry Return / Recall No.
Name, Affiliation Date Date I
Registr erung PAUL SCHERRER INSTITUT
~42-96-20 ALPHA-617-0 PANDA Transient Tests Ersetzt Titel M7 Integral System Test Data Transmittal Report Erstem Autoren/
M. Huggenberger, C. Aubert, J. Dreier, O. Fischer, i
Autorinnen S. Lomperski, H.J. Strassberger
- 28. June 1996 Summary:
This Data iransmittal Report (DTR) summarizes the results of the PANDA transient system 1
test M7 which is a PCC system startup test with bounding noncondensable gas concentrations. The test was initiated with drywell and PCC units initially filled with air l
(noncondensables). One half of the steam flow from the RPV was directed to drywell 1 and the other one-half to drywell 2 (symmetric case). The 5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> test M7 provides data on the 2-PCCS startup characteristics when the system is blanketed with noncondensable gas.
The DTR for test M7 together with the Umbrella DTR satisfies the requirements specified in the Test Plan (TP) 25A5764 Rev 3 (GE document) section 10. The DTR includes: General description and purpose of test, test facility configuration description and a table of actual and specified initial conditions. Further, the test results are presented by time history plots over the test duration and the main observations are given.
j Test M7 has succesfully demonstrated the PCC system startup with bounding noncondensable gas concentrations. The PCC system was capable of purging all the air from the drywell to the wetwell and the PCCs have started their heat removal function without any problems.
The M7 test objectives have been achieved.
Verteder Abt.
Empfanger/ Ernpfangennnen Expl.
Abt.
Ernpfanger/ Empfangennnen Expl.
Expl-42 G. Yadigaroglu 1
GE San Jose CA Bibliothek G. Varadi 1
J.E. Torbeck 1
C. Aubert 1
(for distribution at GE to P'S m 5
T, Bandurski 1
J.R. Fitch, G.A. Wir, gate, 18 J.Dreier 1
B.S. Shiratkar, Total O. Fischer 1
DRF No. T10-0005)
J. Healzer 1
Senen 59 M. Huggenberger 1
Bedagen S. Lomperski 1
H.J. Strassberger 1
in,ormatonsnste PANDA-Documentation 2
Dl1 2l 3l d 5l 8 9
A visum ADtAaborledung:
.. =.
a..
ALPHA.617-0 / Page 4 1
l i
~
Contents
- 1. INTRODUCTION 5
i
)
1.1. General Description and Purpose of Test 5
i 1.2 Purpose of Report 5
1
- 2. TEST OBJECTIVES 5
2.1 General Objectives 5
2.2 Specific Objectives 5
- 3. TEST FACILITY CONFIGURATION AND INITIAL CONDITIONS
~
6 3.1 Test Facility Configuration 6
3.2 Test initial Conditions 6
- 4. TEST RESULTS 12 4.1 Main Observations 12 4.2 Time History Plots 13
- 5. CONCLUSIONS 33 5.1 Adequacy of Test Data 33 5.2 Applicability to Test Objectives 33 l
- 6. REFERENCE DOCUMENTS 34 APPENOlX: COMPOSITION OF DATA RECORDS 35
i,.
ALPHA-317-0 / Page 5
- 1. Introduction l
l l
1.1 General Description and Purpose of Test Test M7 is the PCC system startup test with bounding noncondensable gas concentrations. It is a simulation of a break in the main steam line of the SBWR. The test was initiated with drywell and PCC units filled with air. The initial pressure was approximately 1.3 bar. One-half of the steam from the RPV was directed to DW1 which feeds one PCC condenser, and the other one-half of the steam was directed to DW2 with two PCC condensers connected. This was achieved with separate blowdown lines from the RPV to each of the two drywells. The two blowdown lines have essentially equal flow resistances. These test conditions represent a symmetrical situation in the PANDA facility. This test provides data on the PCC system startup characteristics under difficult conditions.
1.2 Purpose of Report This Data Transmittal Report (DTR)is compiled in accordance with the requirements specified in i
Test Plan (TP) 25A5764 Rev 3 (GE document) Section 10 (1). The report covers the results for the transient integral systems test M7 which has been run in accordance with the test procedure described in (2]. The DTR provides detailed information about test objectives, the test facility l
configuration and the test initial conditions. The test results main observations are reported and a number of plots, which support the findings are included. The conclusions about the adequacy of test data and the applicability of test objectives are given. The composition of the data record is desenbed in an Appendix. The general information about the overall test program, the PANDA facility, the instrumantation, the data acquisition system, the facility characterizatiov lasts, the PANDA expenmental data base and the error analysis is described in the DTR urt t repon (4]. The apparent test results for tes' t M7 are summarized in (3).
- 2. Test Objectives 2.1 General Objectives 1
i The objectives of the PANDA integral system tests are to provide additional data to: a) confirm the capability of TRACG to predict SBWR containment system performance, including potential systems interaction effects (Integral System Tests) and b) demonstrate startup and long-term operation of a passive containment cooling system (Concept Demonstration).
2.2 Specific Objectives The specific objective of test M7 which was initiated with drywell and PCC units filled with air,is to provide data to determine the PCC condenser startup characteristics when blanketed with nonconcensable gas.
ALPHA-617-0 / Page 6
- 3. Test Facility Configuration and initial Conditions i
3.1 Test Facility Configuration The PANDA test facility is described in detail in Section 3 of PSI report ALPHA-606 [4]. For test M7 the PANDA facility was configured to simulate the SBWR post-LOCA configuration as follows:
- 1) The RPV supplies steam to each drywell with two steam lines (one to each drywell). These two steam lines have the same pressure loss characteristics and, therefore, allow for symmetric injection of steam into the two drywells.
[1]).
- 3) The IC unit is isolated by closing the inlet and outlet valves (i.e., the IC feed, drain and vent lines are closed).
- 4) All three PCC units are lined-up to take feedflow from the drywells, to vent noncondensables and steam into the water volume of the suppression pool, and drain condensate to the GDCS volume.
- 5) The three PCC pools are filled and isolated from each other. During the test, no water is added or drained from the pools.
- 6) The only direct lines of communication between the drywell and wetwell are through the vacuum breakers (when the wetwell pressure exceeds drywell pressure sufficiently to open the vacuum breaker) and the main vent lines (which are submerged within the wetwells).
- 7) The GDCS pressure equalization lines to both drywells are open.
- 8) The GDCS drain line with check valve is lined up to return PCC condensate to the RPV.
- 9) The Equalizing lines between the RPV and wetwells are valved out of service.
3.2 Test initial Conditions i
The test initial conditions for test M7 are rather different in comparison to the other M-series tests.
The system pressure for M7 is approximately 1.3 bar instead of 3 bar. The drywell is full with air and at room temperature instead of a steam / air mixture at about 130*C. The initial conditions for test M7 are presented in Table 3.1. The " Average Value" represents the arithmetic mean over the one minute measurement period just before connecting the drywells to the RPV. The " Requested Value" is the value as it is specified in the Test Plan [1].
ALPHA-617-0 / Page 7 Table 3.1: Test M7 initial Conditions VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value ENVIRONMENT PARANETERS Atmospheric pressure MP.EN bar Temperature of saturation for atmospheric pressure (T,ac ts)
C RPV PARANETERS Total pressure MP.RP.1 bar Fluid temperatures:
Spatial average Tp_m.an(RP)
C
]
Local MTF.RP.1 C
i MTF.RP.2 C
MTF.RP.3 C
MTF.RP.4 C
MTF.RP.5 C
DRYWELL PARAMETERS
- Total pressure MP.D1 bar Air partial pressure MPG.D1.1 bar MPG.DI.2 bar MPG.D2.1 bar MPG.D2.2 bar Gas temperatures:
Spatial average To y (D1)
C Local MTG.D1.1 C
MTG.DI.2 C
MTG.DI.3 C
MTG.DI.4 C
MTG.DI.5 C
MTG.DI.6 C
- The Drywell total pressures are not independem vanab6cs. they are given by temperaturts and at parual presswes. The correspond.ng toierana is calculated from temperature and air parual pressure tolerances.
ALPHA.c17 0 / Page 8 Table 3.1: Test M7 Initial Conditions Contd.
VARIABLE PROCESSID UNIT Average Standard Requested Tolerance l
Value Deviation Value DRYWELL PARAMETERS (Cont'd) l l
Spatial average Tc_m.a (D2)
C Local MTG.D2.1 C
l MTG.D2.2 C
MTG.D2.3 C
MTG.D2.4 C
MTG.D2.5 C
MTG.D2.6 C
Water level ML.D1 m
ML.D2 m
SUPPRESSION CHAMBER PARAMETERS Total pressure MP.Sl bar
- Air partial pressure MPG.S1 bar MPG.S2 bar Water temperatures:
Spatial average' Tw m (SI)
C Local MTL.S1.1 C
MTL.SI.2 C
MTL.S1.3 C
MTL.SI.4 C
MTL.S t.5 C
MTL.SI.6 C
Spatial everage Tw_mean(S2)
C Local MTL.S2.1 C-MTL.S2.2 C
MTL.S2.3 C
MTL.S2.4 C
MTL.S2.5 C
l MTL.S2.6 C
- The suppression Chamber er partial pressures are not independant anabies they are given by iemperrtures and total pressures.The correspond-irig toleranca is calculaiad from iemperature and total pressure roterances.
l
ALPHA-617-0 / Page 9 i
Table 3.1: Test M7 Initial Conditions Contd.
i VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value
)
SUPPRESSION CHAMBER PARANETERS (Cont'd) i Gas temperatures:
Spatial average To_m an(SI)
C 1
Local MTG.S t.1 C
MTG.S1.3 C
MTG.S1.4 C
Spatial average To (S2)
C Local MTG.S2.1 C
MTG.S2.2 C
M T G.S2.3 C
MTG.S2.4 C
MTG.S2.5 C
MTG.S2.6 C
Water level M L.S1 m
i GDCS PARAMETERS Total pressure MP.GD bar I
Fluid temperatures:
Spatial average Tp,me.n(GD)
C Local MTF.GD.1 C
j MTF.GD.2 C
MTF.GD.3 C
MTF.GD.4 C
MTF.GD.5 C
MTF.GD.6 C
MTF.GD.7 C
Water level ML.GD m
ALPHA 617-0 / Page 10 Table 3.1: Test M7 Initial Conditions Contd.
VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value PCC1 POOL PARAMETERS 4
i Water temperatures:
Spatial average Tw mon (U1)
C Local MTL.U1.1 C
MTL.U1.2 C
MTL.U1.3 C
MTL.U1.4 C
a MTL.UI.5 C
MR.U1.6 C
MTL.UI.7 C
l Water level ML.UI m
3 PCC2 POOL PARAMETERS i
l
' Water temperatures:
Spatial average Tw mo.(U2)
C Local MTL.U2.1 C
l ME.U2.2 C
i MTL.U2.3 C
i MTL.U2.4 C
MTL.U2.5 C
4 MTL.U2.6 C
j.
MTL.U2.7 C
Water level ML.U2 m
PCC3 POOL PARANETERS Water temperatures:
Spatial average Tw mon (U3)
C
]
Local MTL.U3.1 C
MTL.U3.2 C
MTL.U3.3 C
i
~
I I
ALPHA-617-0 / Page 11 i
i l
Table 3.1: Test M7 initial Conditions Contd.
l l
VARIABLE PROCESSID UNIT Average Standard Requested Tolerance Value Deviation Value l
PCC3 POOL PARAMETERS (Cont'd) l Water temperatures:
j l
Local NfIL.U3.4 C
MTL.U3.5 C
MTL.U3.6 C
l MTL.U3.7 C
i MTL.U3.8 C
l MTL.U3.9 C
l MTL.U3.10 C
l MTL.U3.11 C
MTL.U3.12 C
MTL.U3.13 C
MTL.U3.14 C
l_
MTL.U3.15 C
MTL.U3.15 C
I~
MTL.U3.17 C
MTL.U3.18 C
MTL.U3.19 C
1 Waterlevel ML.U3 m
i i
i l
l I
s L
ALPHA-617-0 / Page 12
- 4. Test Results The main observations _ or the PCC system startup test M7 are presented in Section 4.1. A f
standard set of time history plots for the key parameters and additional plots which support the individual test observations are given in Section 4.2.
4.1 Main Observations i
i 4-1 1
i i
l ALPHA-617-0 / Page 13 4.2 Time History Plots i
i Time history plots are provided to support the observations discussed in Section 4.1 for the following parameters:
Figure RPV, Drywell and Wetwell Pressures 1
PCC Feed Mass Flow Rates 2
l PCC1 Temperatures 3
PCC2 Temperatures 4
PCC3 Temperatures 5
PCC Vent Phase Detectors 6
1 PCC Vent Line Gas Temperatures
,7 Drywell and Wetwell Air Partial Pressures 8
PCC Pool Levels 9
RPV Heater Power 10 i
RPV and Drywell Temperatures 11 Wetwell 1 Gas and Water Temperatures 12 l
Wetwell 2 Gas and Water Temperatures 13 4
Main Steam Line Mass Flow Rates 14 i
Main Vent Phase Detectors 15 5
i Main Vent Une Gas Temperatures 16
)
RPV Water Level 17 j
1 Drywell Water Level 18 L
Wetwell Water Level 19 The identification code for the process variables used in the plots is explained in the DTR Umbrella Report, Section 4 [4). Also, the DAS channel, type, range, accuracy and location of each instrument are given in the Appendix " Composition of Data Records".
l ALPHA-617-0 / Pages 14 through 32 These pages have been deleted from this nonproprietary version of this report, because Figures 1 through 19 which are on these pages in the proprietary version of the report contain proprietary information.
I
1 ALPHA-617-0 / Page 33 i
\\
- 5. Conclusions 5.1 Adequacy of Test Data The integral system test M7 has provided data to determine the PCC system startup characterisites in an adequate manner. Based on the analysis of the test data [3] the test acceptance criteria have clearly been reached. All zero and instrument checks for test M7 have been successfully completed and the instrument readings were within the permitted ranges.
5.2 Applicability to Test Objectives The test objectives as stated in Section 2 of this report have been reached:
1
- The PCC units started purging the drywell air almost immediately after test initiation and were capable to transport all the air to the wetwell.
- Steam condensation on the cold drywell walls in the early part of the test lowered the RPV water level and caused later on RPV steam generation rate oscillations.
- The oscillations in steam flow from the RPV to the drywell had an amplitude of +/- 100% They had no overall effect on PCCS behaviour, except main vent opening.
- The main vents first cleared at approximately 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> and cycled open/close for the duration of the test. Wetwell temperatures indicate a small energy addition to the wetwell.
Consequently, the drywell/wetwell pressure continued to slightly increase over the test duration.
[
- The startup capability of the PCC system has been demonstrated under difficult conditions I
(drywell and PCC units initially filled with nonconcensable gases).
)
-.. _ -. ~ -
ALPHA-617-0 / Page 34
)
a
- 6. Reference Documents
]
[1]
" PANDA Test Plan Tests M3, M3A, M3B, M4, M7' (Specification), GE Document 25A5764 Rev 3, Nov 15,1995.
^
[2]
" PANDA Transient Tests: M7 Integral System Test Procedure *, PSI Internal Report ALPHA-521-0, Nov 14,1995.
[3]
" PANDA Transient Tests: M7 Integral System Test Apparent Test Results', PSI internal Report ALPHA-607-0, April 17,1996, Proprietary Information.
l
[4]
" PANDA Facility, Test Program and Data Base General Description (DTR Umbrella Report) ',
PSI Internal Report ALPHA-606-0, May 31,1996.
[5]
"SBWR Test and Analysis Program Description" (TAPD Licensing Topical Report), GE Report f
NEDC 32391P Rev. C, August 1995, GE Proprietary /n/ormation.
4 N
it 9
j
t ALPHA-617-0 / Page 35 1
Appendix: Composition of Data Records Data Transfer for PANDA Test M7 All variables given by the Table A.1 are contained in four ORACLE tables:
G E_PAND A_M7_MT_LINE 9706 rows G E_PAND A_M7_MT_ POOL 9706 rows i
GE_ PANDA _M7_MT_ VESSEL 9706 rows GE_ PANDA _M7_M_OTHER 9706 rows f
All contain the variable called REC _ID (record identifier) allowing to link records to corresnonding time.
j Time data are given in the table:
GE_ PANDA _M7_M_ TIME 9706 rows j
The structure of all these tables is exactly the same as the one described in the DTR umbrella report (4] for corresponding tables labeled without "G E_'
(PANDA _M7_.,
insfead of GE_ PANDA _M7...); new table names have been used because of database consistency!
All these tables are owned by the user 'aubert' and have been created in the tablespace
" USERS *; they have been exported in file 'M7_GE_ tables.dmp' Measurements with restricted use MV.P3C only qualitative use possible (for example oscillations etc.) absolute value is i
not reliable i
MV.GRT only qualitative use possible (for example oscillations etc.) absolute value is not relicble 4
]-
MV.P1V during whole test below lower flow limit MV.P2V MV.P3V MV.P1 F temporary below lower flow limit (cf. Figure 2)
MV.P2F MV.P3F
. ~... -. -
.. -...... ~. - - - -
. - ~.
[
t ALPHA-617-0 / Page 36 g
Table A.1: M7 Data identification DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 230 CB.VB1 KEY.NOR.AUT 0,50 or 100%
On/Off valve Vacuum Breaker SC1-DW1 231 CB.VB2 KEY.NOR.AUT 0,50 or 100%
On/Off valve Vacuum Breaker SC2-DW2
[
-36.- 150. kPa 1.68 kPa pressure diff. meas. Condensate Return GDCS->RPV l
530 MD.MS1 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW1 531 MD.MS2 RM 3051 CD2 0.- 10. kPa 0.17 kPa pressure diff. meas. Main Steam line RPV->DW2 98 MD.MV1 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW1->SC1
(
99 MD.MV2 RM 1151 DP4 0.- 37. kPa 0.40 kPa pressure diff. meas. Main Vent line DW2->SC2 537 MD.P1 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC1 Condenser 540 MD.P1C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC1 Condensate PCC1->GDCS
[
533 MD.P1F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff, meas. PCC1 Feed DW1->PCC1 544 MD.P1V.1 RM 1151 DP4
-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC1 Vent PCC1->SC1 101 MD.P1V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC1 Vent PCC1-> SCI 538 MD.P2 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC2 Condenser j
541 MD.P2C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC2 Condensate PCC2->GDCS 534 MD.P2F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC2 Feed DW2->PCC2 545 MD.P2V.1 RM 1151 DP4
-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 102 MD.P2V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC2 Vent PCC2->SC2 539 MD.P3 RM 3051 CD2 15.- 25. kPa 0.21 kPa pressure diff. meas. PCC3 Condenser F
542 MD.P3C RM 3051 CD2 0.- 30. kPa 0.25 kPa pressure diff. meas. PCC3 Condensate PCC3->GDCS 535 MD.P3F RM 3051 CD2 0.- 30. kPa 0.26 kPa pressure diff. meas. PCC3 Feed DW2->PCC3 546 MD.P3V.1 RM 1151 DP4
-15.- 22. kPa 0.34 kPa pressure diff. meas. PCC3 Vent PCC3->SC2 103 MD.P3V.2 RM 1151 DP4 0.- 37. kPa 0.37 kPa pressure diff. meas. PCC3 Vent PCC3->SC2
ALPHA-617-0 / Page 37 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 224 MD.VB1 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas Vacuum Breaker SC1-DW1 225 MD.VB2 RM 3051 CD2 20.- 46. kPa 0.19 kPa pressure diff. meas. Vacuum Breaker SC2-DW2 36 ME.RP EH MYCOM 0 - 200 pS/cm 0.5 %
water quality meas. Reactor Pressure Vessel / RPV 70 MI.MV1 PSI /GA COND 0 or 1 phase indicator Main Vent line DW1-> SCI 71 MI.MV2 PSI /GA COND 0 or 1 phase indicator Main Vent line DW2->SC2 1
67 Mt.P1V.1 PSI /GA COND 0 or 1 phase indicator PCC1 Vent PCC1-> SCI l
68 MI.P2V.1 PSI /GA COND 0 or 1 phase indicator PCC2 Vent PCC2->SC2 69 MI.P3V.1 PSI /GA COND 0 or 1 phase indicator PCC3 Vent PCC3->SC2 l
227 ML.D1 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 1/ DW1 228 ML.D2 RM 3051 CD2 0-1.8 m 0.021 m level meas. Drywell 2 / DW2 229 MLGD RM 3051 CD3 0-6.3 m 0.070 m level meas. GDCS tank / GDCS 1
113 ML.MS1 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW1 114 ML.MS2 RM 1151 DP4 0-1.0 m 0.033 m level meas. Main Steam line RPV->DW2 8
ML.RP.1 RM 3051 CD3 0-21.5m 0.166 m level meas. Reactor Pressure Vessel / RPV 9
ML.RP.2 RM 1151 DPS 0-4.1 m 0.157 m level meas. Reactor Pressure Vessel / RPV 107 ML.RP.3 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 108 ML.RP.4 RM 1151 DP4 0-3.8 m 0.042 m level meas. Reactor Pressure Vessel / RPV 226 ML.RP.5 RM 1151 DPS 0-7.7 m 0.166 m level meas. Reactor Pressure Vessel / RPV 360 ML.RP.6 RM 1151 DP5 0-4.6 m 0.158 m level meas. Reactor Pressure Vessel / RPV 110 ML.S1 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 1/ SC1 111 ML.S2 RM 3051 CD2 0-4.6 m 0.039 m level meas. Suppression Chamber 2 / SC2 547 ML.U0 RM 1151 DPS 0-5.6 m 0.156 m level meas' IC pool
ALPHA-617-0 / Page 38 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 548 ML.U1 RM 1151 DP5 0-5.6 m 0.156 m level meas. PCC1 pool 549 ML.U2 RM 1151 DPS 0-5.6 m 0.156 m level meas. PCC2 pool 550 ML.U3 RM 1151 DPS 0-5.6 m 0.156 m level meas. PCC3 pool 72 MO.VB 0 or 1 Vacuum Breaker Trigger signal 555 MP.D1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Drywell 1/ DW1 556 MP.D2 RM 1144 A 0.0- 6.0 bar 0.172 bar absol. pressure meas. Drywell 2 / DW2 2
MP.EN RM 3051 CA2 0.0- 1.5 bar 0.011 bar absol. pressure meas. Environment 338 MP.GD RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. GDCS tank / GDCS 218 MP.MS1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW1 219 MP.MS2 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Main Steam line RPV->DW2 344 MP.P1 F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Feed DW1->PCC1 341 MP.P1V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC1 Vent PCC1->SC1 557 MP.P2F RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Feed DW2->PCC2 342 MP.P2V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC2 Vent PCC2->SC2 558 MP.P3F RM 3051 CA2 0.0- 6.0 bar 0.022 bar ar. sol. pressure meas. PCC3 Feed DW2->PCC3 343 MP.P3V RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. PCC3 Vent PCC3->SC2 554 MP.RP.1 RM 3051 CA2 0.0-10.3 bar 0.023 bar absol. pressure meas. Reactor Pressure Vessel / RPV 58 MP.RP.2 RM 2038 A3 0.0-13.0 bar O.293 bar absol. pressure meas. Reactor Pressure Vessel / RPV 221 MP.S1 RM 3051 CA2 0.0- 6.0 bar 0.022 bar absol. pressure meas. Suppression Chamber 1/ SC1, 222 MP.S2 RM 1144 A 0.0- 6.0 bar 0.169 bar absol. pressure meas. Suppression Chamber 2 / SC2 435 MPG.DI.1 Li1231 02
.002-600 bar 4.0 %
air partial press. meas. Drywell 1/ DW1 air partial iress. meas. Drywell 1/ DW1 437 MPG.D 1.2 LI 123102
.002-600 bar 4.0 %
F 439 MPG.D2.1 Li1231 02
.002-600 bar 4.0 %
air partial press. meas. Drywell 2 / DW2
ALPHA-617-0 / Page 39 Table A.1: M7 Data identification contd.
I DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 441 MPG.D2.2 L1123102
.002-600 bar 4.0 %
air partial press. meas. Drywell 2 / DW2 375 MPG.S1 L1123102
.002-600 bar 4.0 %
air partial press. meas. Suppression Chamber 1/ SCI 377 MPG.S2 Li 123102
.002-600 bar 4.0 %
air partial press. meas. Suppression Chamber 2 / SC2
~
482 MTF.GD.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS g
480 MTF.GD.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 479 MTF.GD.3 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 478 MTF.GD.4 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 477 MTF.GD.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 476 MTF.GD.6 PSITC 1.0-19G.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 475 MTF.GD.7 PSI TC 1.0-196.58 C 0.8 C fluid temp. meas. GDCS tank / GDCS 336 MTF.RP.1 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV i
335 MTF.RP.2 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 334 MTF.RP.3 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 1
96 MTF.RP.4 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 95 MTF.RP.5 PSITC 1.0-196.58 C 0.8 C fluid temp. meas. Reactor Pressure Vessel / RPV 474 MTG.DI.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 473 MTG.D 1.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 472 MTG.D1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 471 MTG.D1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 470 MTG.D1.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 469 MTG.D1.6 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 1/ DW1 467 MTG.D2.1 PSITC 1.0-196.58 C 0.8 C gas temp. (neas. Drywell 2 / DW2 466 MTG.D2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2
ALPHA-617-0 / Page 40 -
Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 465 MTG.D2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 464 MTG.D2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 463 MTG.D2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 462 MTG.D2.6 PSITC 1.0- n'6.58 C 0.8 C gas temp. meas. Drywell 2 / DW2 717 MTG.GP1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 716 MTG.GP1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW1 715 MTG.GP2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. GDCS Pressure equal. GDCS-DW2 714 MTG.GP2.2 PSITC 1.0-196.58 C 0.8 C gas temo. meas. GDCS Pressure equal. GDCS-DW2 713 MTG.11.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 712 MTG.11.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 711 MTG.11.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 710 MTG.11.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 709 MTG.11.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 708 MTG.11.6 PSI TC 1.0-196.58 C
'O.8 C gas temp. meas. IC Condenser 707 MTG.11.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 706 MTG.11.8 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 705 MTG.11.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Condenser 571 MTG.11 F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. IC Feed RPV->lC 459 MTG.11 F.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 704 MTG.11 F.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. IC Feed RPV->lC 237 MTG.MS1.1 HB Pt100' O.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW1 458 MTG.MS t.2 '
PSITC 1.0-196.58 C 0.8 C gas temp. ineas. Main Steam line RPV->DW1 456 MTG.MS1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW1
ALPHA-617-0 / Page 41 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 238 MTG.MS2.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. Main Steam line RPV->DW2 455 MTG.MS2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2 454 MTG.MS2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Steam line RPV->DW2 287 MTG.MV1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 333 MTG.MV1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1-> SCI 216 MTG.MV1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 215 MTG.MV1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW1->SC1 286 MTG.MV2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 332 MTG.MV2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 214 MTG.MV2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 213 MTG.MV2.4 PSI L,
1.0-196.58 C 0.8 C gas temp. meas. Main Vent line DW2->SC2 703 MTG.P1.1 PSI TC 1.0-196.53 C 0.8 C gas temp. meas. PCC1 Condenser 702 MTG.P1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 701 MTG.P1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 700 MTG.P1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 699 MTG.P1.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 698 MTG.P1.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 696 MTG.P1.7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 695 MTG.P1.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 694 MTG.P1.9 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Condenser 572 MTG.P1 F.1 HB Pt100-0.0-200.00 C 0.2 C gas terrp. meas. PCCI Feed DW1->PCC1 693 MTG.P1 F.2 PSI TC 1.0-196.58 C 0.8 C gas temp. rneas. PCC1 Feed DW1->PCC1
ALPHA-617-0 / Page 42 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGEA) NIT ACCURACY LOCATION 365 MTG.P1V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC1 Vent PCC1->SC1 692 MTG.P1V.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1-> SCI 331 MTG.P1V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 212 MTG.P1V.4 PSITC 1.0-196.58 C O.8 C gas temp. meas. PCC1 Vent PCC1->SC1 211 MTG.P1V.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC1 Vent PCC1->SC1 691 MTG.P2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 690 MTG.P2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 689 MTG.P2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 688 MTG.P2.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 687 MTG.P2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 686 MTG.P2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 685 MTG.P2.7 PSI TC 1.0-196.58 C 0.8 C gas tsmp. meas. PCC2 Condenser 684 MTG.P2.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 683 MTG.P2.9 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Condenser 573 MTG.P2F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC2 Feed DW2->PCC2 682 MTG.P2F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Feed DW2->PCC2 366 MTG.P2V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC2 Vent PCC2->SC2 681 MTG.P2V.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 330 MTG.P2V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 210 MTG.P2V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 209 MTG.P2V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC2 Vent PCC2->SC2 528 MTG.P3.1 PSITC 1.0-196.58 C 0.8 C gas temp.' meas. PCC3 Condenser
ALPHA-617-0 / Page 43 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 527 MTG.P3.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 526 MTG.P3.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 525 MTG.P3.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 524 MTG.P3.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 523 MTG.P3.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 522 MTG.R).7 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 521 MTG.P3.8 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 520 MTG.P3.9 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Condenser 574 MTG.P3F.1 HB Pt100 0.0-200.00 C 0.2 C gas temp. meas. PCC3 Feed DW2->PCC3 680 MTG.P3F.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Feed DW2->PCC3 367 MTG.P3V.1 HB Pt100 0.0-200.00 C 0.4 C gas temp. meas. PCC3 Vent PCC3->SC2 679 MTG.P3V.2 PbiTC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 329 MTG.P3V.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 208 MTG.P3V.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 207 MTG.P3V.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. PCC3 Vent PCC3->SC2 206 MTG.S t.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 205 MTG.S t.2 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 204 MTG.SI.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 203 MTG.SI.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 202 MTG.S t.5 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 201 MTG.S t.6 PSI TC '
1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 1/ SC1 199 MTG.S2.1 PSI TC 1.0-196.58 C 0.8 C gas temp. r'neas. Suppression Chamber 2 / SC2 198 MTG.S2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2
ALPHA-617-0 / Page 44 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 197 MTG.S2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 196 MTG.S2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 195 MTG.S2.5 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 194 MTG.S2.6 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Suppression Chamber 2 / SC2 449 MTG.TDO.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 448 MTG.TDO.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 447 MTG.TDO.3 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. DW1-DW2 connection 328 MTG.TSU.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 327 MTG.TSU.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 326 MTG.TSU.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. SC1-SC2 Upper connection 325 MTG.VB1.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 324 MTG.VB1.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 446 MTG.VB1.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 445 MTG.VB1.4 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC1-DW1 323 MTG.VB2.1 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 322 MTG.VB2.2 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 444 MTG.VB2.3 PSITC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 443 MTG.VB2.4 PSI TC 1.0-196.58 C 0.8 C gas temp. meas. Vacuum Breaker SC2-DW2 283 MTI.D1.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 282 MTI.D1.2 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 281 MTI.D1.3 PSITC -
1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 280 MTI.DI.4 PSITC 1.0-196.58 C 0.8 C inside wall' temp. meas. Drywell 1/ DWt
ALPHA-617-0 / Page 45 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 279 MTI.DI.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 278 MTI.DI.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 277 MTI.D1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 276 MTI.DI.8 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 275 MTI.D1.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 1/ DW1 274 MTI.D2.1 PSI TC 1.0-196.58 C 0.8 C ir. side wall temp. meas. Drywell 2 / DW2 273 MTI.D2.2 PSI TC 1.0-196.58 C 0.8 C inside wall temp. m9as. Drywell 2 / DW2 272 MTI.D2.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 271 MTI.D2.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 270 MTI.D2.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 269 MTI.D2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 268 MTI.D2.7 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 267 MTI.D2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 266 MTI.D2.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Drywell 2 / DW2 263 MTI.GD.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 262 MTI.GD.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 261 MTI.GD.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 260 MTI.GD.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 259 MTI.GD.5 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 258 MTI.GD.6 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. GDCS tank / GDCS 244 MTI.RP.1 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Reactor Pressure Vessel / RPV 243 MTI.RP.2 PSITC 1.0-196.58 C 0.8 C inside wa!! temp. meas. Reacior Pressure Vessel / RPV
ALPHA-617-0 / Page 46 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 242 MTI.RP.3 PSITC 1.0-196.58 C 0.8 C inside watt temp. meas. Reactor Pressure Vessel / RPV 191 MTI.SI.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 190 MTI.S t.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 189 MTI.S t.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 188 MT1.S1.4 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 187 MTI.S t.5 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI _
186 MTl.S1.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 185 MTI.S1.7 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 184 MTI.St.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SCI 183 MTI.SI.9 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 1/ SC1 182 MTI.S2.1 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 181 MTI.S2.2 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 180 MTI.S2.3 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 179 MTI.S2.4 PSiTC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 178 MTI.S2.5 PSITC 1.0-196.58 C 0.8 C inside GL temp. meas. Suppression Chamber 2 / SC2 177 MTI.S2.6 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 176 MTI.S2.7 PSI TC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 175 MTI.S2.8 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 174 MTI.S2.9 PSITC 1.0-196.58 C 0.8 C inside wall temp. meas. Suppression Chamber 2 / SC2 14 MTL.EQO HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. EOualization line common branch 15 MTLGRT.1 HB Pt100' O.0-200.00 C 0.2 C liquid temp. meas. Condensate Return GDCS->RPV 88 MTL.GRT.2 PSI TC 1.0-196.58 C 0.8 C liquid temp'. meas. Condensate Retum GDCS->RPV
ALPHA-617-0 / Page 47 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 317 MTL.GRT.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Condensate Return GDCS->RPV 674 MTL.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC Condenser 16 MTL.11C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. IC Condensate IC->RPV 672 MTL.11C.2 PSITC 1.0-196.58 C O.8 C liquid temp. meas. IC Condensate IC->RPV 173 MTL.11C.3 PSI TC 1.0-196.58 C 0.8 C iuid temp. meas. IC Condensate IC->RPV 671 MTL.P1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCCI Condenser 234 MTL.PIC.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 670 MTL.P1C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 Condensate PCC1->GDCS 669 MTL.P2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condenser 235 MTL.P2C.1 HB Pt100 0.0 200.00 C 0.4 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 668 MTL.P2C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 Condensate PCC2->GDCS 519 MTL.P3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condenser 236 MTL.P3C.1 HB Pt100 0.0-200.00 C 0.4 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 667 MTL.P3C.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 Condensate PCC3->GDCS 86 MTL.RP.1 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 85 MTL.RP.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Reactor Pressure Vessel / RPV 172 MTL.SI.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 171 MTL.S1.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SCI 170 MTL.S I.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 168 MTL.S t.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SCI 167 MTL.S t.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 1/ SC1 166 MTL.S I.6 PSITC 1.0-196.58 C 0.8 C liquid temp'. meas. Suppression Chamber 1/ SC1
ALPHA-617-0 / Page 48 Table A.1: M7 Data identification contd.
DACHANNEL PFIOCESSID TYPE RANGE / UNIT ACCURACY LOCATION 165 MTL.S2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 164 MTL.S2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 163 MTL.S2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 162 MTL.S2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 161 MTL.S2.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 160 MTL.S2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. Suppression Chamber 2 / SC2 159 MTL.TSL.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 158 MTL.TSL.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 157 MTL.TSL.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. SC1-SC2 Lower connection 432 MTL.UO.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 431 MTL.UO.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 430 MTL.UO.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 429 MTL.UO.4 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC poo:
428 MTL.UO.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 427 MTL.UO.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 426 MTL.UO.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. IC pool 657 MTL.U1.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 656 MTL.U1.2 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 655 MTLU1.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 654 MTLU 1.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 653 MTLU1.5 PSITC -
1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 652 MTL.U1.6 PSI TC 1.0-196.58 C 0.8 C liquid temp'. meas. PCC1 pool
ALPHA-617-0 / Page 49 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 651 MTL.U 1.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC1 pool 647 MTLU2.1 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 646 MTLU2.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 645 MTL.U2.3 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 644 MTL.U2.4 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 643 MTL.U2.5 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 642 MTL.U2.6 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 641 MTL.U2.7 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC2 pool 518 MTL.U3.1 PSITC 1.0-196.59 C 0.8 C liquid temp. meas. PCC3 pool 517 MTLU3.2 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 516 MTLU3.3 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 515 MTLU3.4 PSI TC 1.0-196.58 C 0.8 C hquid temp. meas. PCC3 pool 514 MTL.U3.5 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 513 MTL.U3.6 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 512 MTLU3.7 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 511 MTL.U3.8 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 510 MTL.U3.9 PSI TC 1.0-196.58 C 0.6 C liquid temp. meas. PCC3 pool 509 MTL.U3.10 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 508 MTL.U3.11 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 507 MTL.U3.12 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 506 MTL.U3.13 PSITC '
1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 504 MTL.U3.14 PSITC 1.0-196.58 C 0.8 C liquid temp'. meas. PCC3 pool
ALPHA-617-0 / Page 50 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 503 MTL.U3.15 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 502 MTL.U3.16 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 501 MTL.U3.17 PSI TC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 500 MTL.U3.18 PSITC 1.0-196.58 C 0.8 C liquid temp. meas. PCC3 pool 499 MTL.U3.19 PSITC 1.0-196.08 C 0.8 C liquid temp. meas. PCC3 pool 636 MTO.DI.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 635 MTO.DI.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 634 MTO.D1.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 254 MTO.D1.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 253 MTO.D1.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ GW1 252 MTO.D1.6 PSI TC 1.0-196.58 C 0 8 C, outside wall temp. meas. Drywell 1/ DW1 315 MTO.DI.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 314 MTO.D1.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 312 MTO.D1.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 1/ DW1 633 MTO.D2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 632 MTO.D2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 631 MTO.D2.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 257 MTO.D2.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 256 MTO.D2.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 255 MTO.D2.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 311 MTO.D2.7 PSI TC '
1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 310 MTO.D2.8 PSITC 1.0-196.58 C 0.8 C outside wait temp. meas. Drywell 2 / DW2 f
i
ALPHA.617-0 / Page 51 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 309 MTO.D2.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Drywell 2 / DW2 251 MTO.GD.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 250 MTO.GD.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GCCS 249 MTO.GD.3 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 248 MTO.GD.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 247 MTO.GD.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 246 MTO.GD.6 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. GDCS tank / GDCS 308 MTO.S t.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 307 MTO.S t.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 306 MTO.SI.3 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 156 MTO.SI.4 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 155 MTO.S1.5 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 154 MTO.S1.6 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 80 MTO.S t.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 79 MTO.St.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SCI 78 MTO.S t.9 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 1/ SC1 305 MTO.S2.1 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 304 MTO.S2.2 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 303 MTO.S2.3 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 153 MTO.S2.4 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 152 MTO.S2.5 PSI TC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 151 MTO.S2.6 PSITC 1.0-196.58 C 0.8 C outside wail temp. meas. Suppression Chamber 2 / SC2
ALPHA-617-0 / Page 52 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 77 MTO.S2.7 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 76 MTO.S2.8 PSITC 1.0-196.58 C 0.8 C outside wall temp. meas. Suppression Chamber 2 / SC2 75 MTO.S2.9 PSITC 1.0-196.58 C 08C outside wall temp. meas. Suppression Chamber 2 / SC2 434 MTP.D1.1 L1 TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 1/ DW1 436 MTP.D1.2 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 1/ DW1 438 MTP.D2.1 L1 TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 2 / DW2 440 MTP.D2.2 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Drywell 2 / DW2 374 MTP.S1 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Suppression Chamber 1/ SC1 376 MTP.S2 Li TC 0.0-1000.0 C 0.75 %
Temp. for oxygen Probe Suppression Chamber 2 / SC2 408 MTS.D1.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 407 MTS.D1.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 406 MTS.D1.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 1/ DW1 405 MTS.D2.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 404 MTS.D2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 403 MTS.D2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Drywell 2 / DW2 402 MTS.GD.1 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 401 MTS.GD.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 400 MTS.GD.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. GDCS tank / GDCS 150 MTS.S t.1 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 149 MTS.S t.2 PSI TC 1.0-196.58 C 0.6 C pool surface temp. meas. Supprusion Chamber 1/ SC1 148 MTS.S1.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 1/ SC1 147 MTS.S2.1 PSITC 1.0-196.58 C 0.6 C pool surfac'e temp. meas. Suppression Chamber 2 / SC2
ALPHA-617-0 / Page 53 Table A.1: M7 Data identification contd.
DACHANNEL PFIOCESSID TYPE FLANGE / UNIT ACCURACY LOCATION 146 MTS.S2.2 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 144 MTS.S2.3 PSITC 1.0-196.58 C 0.6 C pool surface temp. meas. Suppression Chamber 2 / SC2 425 MTT.11.1 PSITC 1.0-196.58 C O.8 C tube wall temp. meas. IC Condenser 424 MTT.11.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 423 MTT.11.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 422 MTT.11.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 421 MTT.11.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 420 MTT.11.6 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 419 MTT.11.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 418 MTT.11.8 PSITC 1.0-196.58 C 0.8 C tube wall te np. meds IC Condenser 417 MTT.11.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 416 MTT.11.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 415 MIT.11.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 414 MTT.11.12 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 413 MTT.11.13 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 412 MTT.11.14 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 411 MTT.11.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 410 MTT.11.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. IC Condenser 613 MTT.P1.1 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCCI Condenser 612 MTT.P1.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 611 MTT.P1.3 PSITC ~
1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 610 MTT.P1.4 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser
ALPHA-617-0 / Page 54 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 609 MTT.P1.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 608 MTT.P1.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 607 MTT P1.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 606 MTT.P1.8 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 605 MTT.P1.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 604 MTT.P1.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 603 MTT.P1.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 602 MTT.P1.12 PSITC 1.0-196.58 C 0.8 C tube wait temp. meas. PCC1 Condenser 600 MTT.P1.13 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 599 MTT.P1.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC1 Condenser 598 MTT.P1.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCCI Condenser i
597 MTT.P1.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCCI Condenser 630 MTT.P2.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 629 MTT.P2.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 628 MTT.P2.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 627 MTT.P2.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 626 MTT.P2.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 624 MTT.P2.6 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 623 MTT.P2.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 622 MTT.P2.8 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 621 MTT.P2.9 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 620 MTT.P2.10 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser
~
ALPHA-617-0 / Page 55 Table A.1: M7 Data identification contd.
DACHANNEL PFIOCESSID TYPE RANGE / UNIT ACCURACY LOCATION 619 MTT.P2.11 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 618 MTT.P2.12 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 617 MTT.P2.13 PSITC 1.0-196.58 C 0.8 C tube wc!! temp. meas. PCC2 Condenser 616 MTT.P2.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 615 MTT.P2.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 614 MTT.P2.16 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC2 Condenser 498 MTT.P3.1 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 497 MTT.P3.2 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 496 MTT.P3.3 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 495 MTT.P3.4 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 494 MTT.P3.5 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 493 MTT.P3.6 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 492 MTT.P3.7 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 491 MTT.P3.8 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 490 MTT.P3.9 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 489 MTT.P3.10 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 488 MTT.P3.11 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 487 MTT.P3.12 PSITC 1.0-196.58 C O.8 C tube wall temp. meas. PCC3 Condenser 486 MTT.P3.13 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 485 MTT.P3.14 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 484 MTT.P3.15 PSITC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser 483 MTT.P3.16 PSI TC 1.0-196.58 C 0.8 C tube wall temp. meas. PCC3 Condenser
ALPHA-617-0 / Page 56 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 569 MTV.GP1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 568 MTV.GP1.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW1 567 MTV.GP2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 566 MTV.GP2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. GDCS Pressure equal. GDCS-DW2 302 MTV.GRT PSITC 1.0-196.58 C 0.8 C wall temp. meas. Condensate Return GDCS->RPV 596 MTV.11C PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Condensato IC->RPV 594 MTV.11 F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 399 MTV.11 F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 595 MTV.11 F.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. IC Feed RPV->lC 397 MTV.MSI.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 398 MTV.MSI.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 396 MTV.MSI.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW1 394 MTV.MS2.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 395 MTV.MS2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 393 MTV.MS2.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Steam line RPV->DW2 292 MTV.MV1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 301 MTV.MV1.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 140 MTV.MV1.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW1->SC1 291 MTV.MV2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 300 MTV.MV2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Main Vent line DW2->SC2 141 MTV.MV2.3 PSITC ^
1.0-196.58 C 0.S C wall temp. meas. Main Vent line DW2->SC2 593 MTV.PIC PSITC 1.0-196.58 C 0.8 C wall temp. ' meas. PCC1 Condensate PCC1->GDCS
ALPHA-617-0 / Page 57 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 592 MTV.P1 F.1 PSITC 1.0-196 58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 591 MTV.P1 F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Feed DW1->PCC1 390 MTV.P1V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 590 MTV.P1V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCCI->SC1 299 MTV.P1V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCCI->SC1 137 MTV.P1V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC1 Vent PCC1->SC1 589 MTV.P2C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Condensate PCC2->GDCS 588 MTV.P2F.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 587 MTV.P2F.2 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Feed DW2->PCC2 389 MTV.P2V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 586 MTV.P2V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 298 MTV.P2V.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 138 MTV.P2V.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. PCC2 Vent PCC2->SC2 585 MTV.P3C PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Condensate PCC3->GDCS 584 MTV.P3F.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 583 MTV.P3F.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Feed DW2->PCC3 388 MTV.P3V.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 582 MTV.P3V.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 297 MTV.P3V.3 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 139 MTV.P3V.4 PSITC 1.0-196.58 C 0.8 C wall temp. meas. PCC3 Vent PCC3->SC2 296 MTV.VB1.1 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 wall temp. ' eas. Vacuum Breaker SC1-DW1 294 MTV.VB1.2 PSITC 1.0-196.58 C 0.8 C m
ALPHA-617-0 / Page 58 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 382 MTV.VB1.3 PSI TC 1.0-196.58 C 0.8 C walltemp. meas. Vacuum Breaker SC1-DW1 t
384 MTV.VB1.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC1-DW1 295 MTV.VB2.1 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 293 MTV.VB2.2 PSITC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 379 MTV.VB2.3 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2 381 MTV.VB2.4 PSI TC 1.0-196.58 C 0.8 C wall temp. meas. Vacuum Breaker SC2-DW2-118 MV.GRT I USON 994 449-2722 g/s 2.0 %
volume flow meas. Condensate Retum GDCS->RPV 358 MV.MS1 i VORTEX 100 135-595 g/s 1.5 %
volume flow meas. Main Steam line RPV->DW1 359 MV.MS2 i VORTEX 100 134-592 g/s 1.5 %
volume flow meas. Main Steam line RPV->DW2 562 MV.P1 F i VORTEX 80 72-311 g/s 1.5 %
volume flow meas. PCC1 Feed DW1 >PCC1 352 MV.P1V i VORTEX 80 68-262 g/s 2.0 %
volume flow meas. PCC1 Vent PCC1->SC1 563 MV.P2F i VORTEX 80 73-327 g/s 1.5 %
volume flow meas. PCC2 Feed DW2->PCC2 353 MV.P2V I VORTEX 80 62-259 g/s 2.0 %
volume flow meas. PCC2 Vent PCC2->SC2 116 MV.P3C 1 USON 994 53-387 g/s 2.0 %
volume flow meas. PCC3 Condensate PCC3->GDCS 564 MV.P3F 1 VORTEX 80 71-342 g/s 1.5 %
volume flow meas. PCC3 Feed DW2->PCC3 354 MV.P3V I VORTEX 80 63-263 g/s 2.0 %
volume flow meas. PCC3 Vent PCC3->SC2 42 MW.RP.1 CB SYNEAX 0 - 50 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV-43 MW.RP.2 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 44 MW.RP.3 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV I
45 MW.RP.4 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 46 MW.RP.5 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV 47 MW.RP.6 CB SYNEAX 0 - 300 kW 0.6 %
electrical power meas Reactor Pressura Vessel / RPV i
6 r
.e-
.w
- _____m, m
.mm.-
m m
o ALPHA-617-0 / Page 59 Table A.1: M7 Data identification contd.
DACHANNEL PROCESSID TYPE RANGE / UNIT ACCURACY LOCATION 48 MW.RP.7 HB TZA4 TOT 0 - 1500 kW 0.6 %
electrical power meas Reactor Pressure Vessel / RPV A Total of 511 Data Records
.. m 1..
m.
2
. m
-