{{#Wiki_filter:- 4(S8 TABLE OF CONTENTS Page A. INTRODUCTION AND GENERAL INFORMATION A-1 B. SAFETY ANALYSIS B-1
- 1) Reactor Site Description B-1 (a) Meteorological Data B-4 (b) Geological Data B-7 (c) Seismology B-8 (d) Hydrology B-10
- 2) Facility Description B-10 (a) Principal Design Criteria B-19 (b) Design Base B-19 (c) Design Details B-19 i Reactor B-19 11 Reactor Description B-21 iii Ventilation B-40 iv Radioactive Material Generation and Disposal B-41 v Monitoring Facilities B-41 C. PRELIMINARY SAFETY REVIEWS
- 1) Loss of Coolant Accident C-1
- 2) Fuel Element Failure in Air C-6
- 3) Reactivity Insertion C-12
- 4) Mechanical Rearrangement of Fuel C-14 D. REACTOR OPERATIONS D-1
- 1) Organization D-1
- 2) Training D-2
- 3) Outline of Reactor Startup and Calibration D-2 3.1 Precrit1 cal Test D-2 3.1.1 Functional Tests of Critical Equipment D-2 3.1.2 Checkout of instrumentation and Control System D-2 3.2 Initial Loading of Fuel Elements to Criticality Using Inverse Multiplication Data D-2 3.3. Tests to be Performed upon Reaching Criticality D-4 3.4. Tests to be Performed at Higher powers D-7 l 3.5. Tests at Rate Power D-7 l
8407100134 PDR ADOCK [ hPDR 4 P i
#h.
SAFETY ANALYSIS Reactor Site Description The reactor site is located in the Engineering Building on the campus of Michigan State University. The campus is located in the southern area of the city of East Lansing, in Ingham County, in the state of Michigan. Reference to the floor plans (Figures 5,6,7 and 8) (Appendix 1) of the Engineering Building will provide an adequate description of the building layout. The site within the Engineering Building is on the southern edge of the main campus. University farm lands and few agricultural research laboratories occupy the area to the south to a distance of four to five miles. These areas are sparsely populated. Classrooms, offices, and student residence halls lie to the north, east, and west of the site. Outside the campus area in a northerly direction is the city of East-Lansing. Some areas of the city also lie to the east and west of the site. The city is approximately 3/4 to 1 mile from the site. East Lansing is primarily a residential community composed of year around residents and students of the university. Most of the business are retail stores. To the west and southwest of the main ccapus (which is bounded on the west by
' Harrison Road) are university apartments for married students.
The population of the city of East Lansing, is approximately 51,000. This includes students who live as residents of the city. The number of students attending the university varies somewhat from season to season, but the peak student population is approximately 44,000. Of this number about 15,500 are on-campus residents in residence halls. A significant number of students commute to the campus from places of residence outside the East Lansing area. A map of the East Lansing area (Figure 1) is included in this report in order to provide a physical representation of the area. To represent the resident population, Table 1 is included with censua tract numbers used to identify population districts. Approximations of peak population densities (i.e. during the academic year on week days between 8 a.m. and 5 p.m.) are as follows: 0-1/2 mile - 3400 people; 1/2 mile to 1 mile - 21,000; 1 mile to 1 1/2 miles - 11,700; and 1 1/2 to 2 miles 7200. These approximations are derived from 1980 census statistics, Michigan State University personnel and on campus housing departments statistics. In addition to the students living on campus there are approximately 8,500 people working 8 hours per day on the campus in such capacities as professors, administrative personnel, clerical-technical personnel, and labor people. The B-1 Revision 1 6/84
a , . , c , o e e J CITY OF '
%\g
- _. EAST LANSING '
l
'A : Michigan t .i ,n, li
[ Me. %
.i o
m f j, TO , g,y .. A _ CENSUS TRACTS i !
" ~
II , i +- h -- F --
.r + - - -=p != .- 38 6 Mn1 ] .._ _ _ ~
y. I--- r . . 38.01[*.",k M a.
~~
W g ~fr - s p -j % L ==-eW (
~.. ,~ . s /'/
c=--@l d 7
,e ' $~ h%Q dU pv;4. ~ _
il '
~ ~
j[PE ,
$.h ,i h %' 39.0 M64 [ C1., -
ag;_:r- ,- p ., - ' i g1J F# C .iW--"#
- G- '
i g gl 7,@."<- V,r#'t
, ~~ - L- p- cri, a, . , _ ,~
Ti r. 4 - v n-
. s. @w. + '7 b- M'TnN_i~2 --b_.
pa f/;g
, ,. ' g, - .;.e, ,
Ti# . ' 4 ^_. y iQ q iv-m~ , . % ; 39,02:
.- i r1 l' ~r N~ * ; .
F A_
, l "I" E ~,W . g-F b!- M tL_j l . . e, e E::; _
s i j eN. h- ._.
;x' .k., /f g.% , I .: Gim,rT ,c ;.> a.> e,* ---
Is li"(l p: ,, a i e
%x.% m ._,i -..
_9 4 , gg f"k \@ PT9]ID, ,m---W rE t ~~ Y' ~
~""" -- -
l Si N-
@* N ,, (p d ," ,1#N -< : ___.S .
e-I. f . _[ , -~,IJ , Jd,y, , b 'y.=__*_ --h
. 4.-
m- - m
% ,,'i; a
im , _L_ j( w%4y i !'I.~3- yr,- : y1. ; r- f ,e .
- t== *e. s /j 'A s
y t,i u,.u,-
- ._ , .m;. . "n r d ..
[
\
p? m
, + . -\ ,
y \ a
.03 i , 'ij, e ,\ :,
r W' y!
-, __ --- L = e.- ___ . ,,
N c
$ i g O5 '
e2 b\ @,.;d l- dd;'(\ (j>M.o1J
~
M.x,- ~if 1) / fl t I _ 9h
/
Bi
%~ ,r44,'02' x
_-w_ -W _N N
~ , / i. ,i i
i f i
=..b 4r w i
N '.N ' t
/ < H l
I % m
/ !
i ,. \
~
i N .s p ; lE I -
,/ <
l 10 i i 2 I . Figure 1 ' 1 mile A S C D E I l B-2 .
J l Table 1 EAST LANSING POPULATION CHARACTERISTICS CENSUS TOTAL PERSONS AGE PERSONS AGE TRACT POPULATION MALE FEMALE 60 AND OVER 1 17 AND 'INDER I 29.01 -14 6 8 2 14.3 6 42.9 38.01 3,648 1,800 1,848 211 5.8 1,204 33.0 38.02 2,002 896 1,106 323 16.1 376 18.8 39.01 1,791 854 937 316 17.6 432 24.1 39.02 3,989 1,928 2,061 447 11.2 707 17.7 40 3,766 1,820 1,946 577 15.3 766 20.3 41 4,882 2,449 2,433 210 4.3 162 3.3 42 5,656 2,590 3,066 1 0.0 47 0.8 43.01 4,253 2,136 2,117 338 7.9 608 14.3 43.02 2,877 1,347 1,530 6 0.2 11 0.4 44.01 11,400 5,894 5,506 3 0.0 53 0.5 44.02 3,852 1,879 1,973 14 0.4 1,002 26.0 44.03 2,993 1,492 1,501 119 4.0 711 23.8 46 269 131 138 8 3.0 58 21.6 Citywide 51,392 25,222 26,170 2,575 5.0 6,143 12.0 Source: 1980 Census Tape STF 1A B-3 ' i_
a 5 majority of these people work within 1 mile of the reactor site. The portion of the students of the university not residing on campus spend varying amounts of time per day on the campus. They are a highly mobile group and cannot be said to be in any one campus building for a significant amount of time. These people as well as the university employees could easily be moved from the area if a danger-ous situation was caused by a reactor accident. A map of the campus has been included in this report (Figure 2). It shows the location of the reactor site in relation to the rest of the campus. Campus buildings with appropriate identification are shown. In addition, it shows new construction on the campus. Meteorological, Geological, and Hydrological Data (1) Meteorological Data Meteorological Data for the site were obtained from the Department of Commerce's Agricultural Services Office at 1405 S. Harrison Road, East Lansing, Michigan. The data were recorded at Capital City Airport which is located approximately 6 miles from the reactor site. Since the terrain between the site and the airport is flat with no major hills or valleys, the data are expected to be representative of the site. Figure 3 is a wind rose showing wind direction, speed and the percentage of time the wind blows in any one direction. Temperature and precipitation data are given in Table 2. Table 2. Temperature and Precipitation Data of the Reactor Site (1943-1982). Annual average temperature 46.8*F Coldest month February Hottest month July Annual total precipitation 30.65 Wettest month Juna Driest month February 4 There is a history of tornados occurring in Michigan. According to the United States Weather Bureau, Office of the State Climatologist's bulletin
" Michigan Tornado Fact Sheet," Michigan lies at the north-eastern edge of the B-4 Revision 1 6/84 i
_ _ ! .1 .....i.,,_,........,_...,....,_.,.,
. // f/ W - H= _l.
t 7 n Il thrdi 'jn__
! - l L
f $ .
*b $25*f -
c wmt : in'g{Tf ;j =se o',! wt
? < , l sll sei g , /
5 x i e i - h.nN_-___ -_h& *
--OMO
__.ihj-N7l 477 , l 3 : N
- s p'
/ ,j 'iEp*, ) *.
ll j' y!awII :& ,
,! i l' ikf' j /d l
w 01 : h$*'
; t' j- =
j j j ~ 1i I I , - 2 f.0 ( _ _-- e _ ,g / " - - a=== l 1 ; .
,IclllII s ~
gk j t ll '- I t [! yf _ h I% f q\ ; I
'I 5 I ' ~ ~~ , < 2 ! ,r E ~~ *g 'q "i " $'i l' I I l, jp ; ; )] l y sl d l
__4* w
~L , L -i =" w =.M L:~.=Ly,5G g nc 1 a l ; ,li (elip em ,q w'-
3 y 1 N 9 ! If u ; I o C r 0
}hijy: n f L. ------ %gj ' , ' '- } , ,/
1 k_ m ex g % g ,i, ioI i
$ > s~v l 1 p Q.ff - '
l 7 j! f- 3 Oxd 1.t w*< f3 ii 8 . l' ' ll F d, ,t . j> l ! li 4%() EN -.. > s l 1
, , t /j \lD en h ""
jo
/ l \,,3 , /l E ~~ -- - ; 5 l ,. .,~.. .. . 1. .. :. . .r u.. . .; ;_, . -.,._;.. -
_., .1 .; ;_ ._ ; , , , . 7.- Figure 2 B-5
. i I,
f l l 30 10 350 y 3 20 NNg i 47 2n QD , ph
)
fo o {
~
0, . O S ,o .
'2 ph g '0J s
e
- o
.'o e o
3
. o \
e ~
++ . e , w . a . s- gh sO $n , *El ' G) E5 ph .
e $ g x.b ,
' ' o 1. ,o a 'e, a ~
oP 0 i
'#6 ' " , . . 4 '
ti
* #3 i o 5.89 A 2.82 1.39 l '
3 o_ i n3 . . 25 4.84
- 3
~ 30 g /. a9 Ys a ~
g o a k g% T T *w Tds 'r s
'4 \
Lb / og &~,. o -
$9&0 3.5 #
Mo i s 7 C -
~
M' o - 4 o "5 'oj
.e J
o 04 y ., n Ed o % O . o * .
#o l O SSi+r cp6 N g60 \
200 l0 10 110 i l 2 a = 6. 06 % calms, 0-3 miles per hour Numbers shown are percentages of time in direction and velocity i period of observation. 5 yea rs indicated l i I i t , i t i Figure 3. Wind Rose Recorded in Lansing Michigan i l i ! B-6 u_ . ._ r
, i nation's maximum frequency belt for tornados. In Michigan for the 58-year period of 1918-1975. June has produced the greatest frequency of tornados, tornado days, and number or deaths due to tornados. The month of December has never produced a verified tornado. February has produced only two. Michigan, during the 1956-1974 period has averaged 13 tornados per year. This can be compared to data from the surrounding states: Illinois 30, Indiana 23, Ohio 15. Wisconsin 20, and Minnesota
- 17. About 80 percent of the Michigan tornados occur in the southern one-half of the lower peninsula.
The general area around the site is also susceptible to damaging windstorms. A review of weather bureau data on damaging windstorms (excluding tornados) shows a total of 27 windstorms creating damage in excess of $500,000 since 1900. Of these storms, only 8 are listed as having winds in excess of 75 miles per hour. These windstorms had accompanying rain, freezing rain, hail, or snow. (b) Geological Data - Data received from T.T. "ujita at the University of Chicago indicates that although East Lansing is in the Southern half of Michigan's lower peninsula (the area of highest tornado frequency in the state), East Lansing has been histori-cally free of tornados. Between 1930 and 1974 all tornados passed to the North and West of the reactor site or South and East. East Lansing lies within a pocket of relative quiet. The storms to the North West have all been of the F2 or F3 intensity on the Fujita scale. One storm (about 10 miles North of the reactor site) of the F4 or F5 intensity was recorded between 1940 a'nd 1949. 4 Geology The northwestern corner of Ingham County lies near the center of the Michigan Basin, an intracratonic basin developed on Precambrian crust. The basin is filled with primarily Paleozoic sedimentary rocks approximately 15,000 feet thick. In the Lansing area, bedrock, which consists of shales and sandstones of the Saginaw formation of Pennsylvanian age, are covered with a layer of glacial drift approximately 75' thick. . Bedrock is essentially undeformed and faults do not offset the younger formations. Figure 4 shows the earth profile in the immediate area of the reactor site. This well log was taken before reactor tank installation. , B-7 Revision 1 6/84 Lu.
. 9 Seismology Some 16 events have been reported in southern Michigan since 1870. The most destructive of these had an intensity of VI on the modified Mercalli scale. i.e., " felt by all; many frightened and run outdoors. Some heavy furniture moved; a few instances of fallen plaster or damaged chimneys. Damage slight." Quantitatively, this probably translates to Richter magnitude of about 4.0.
Of the 16 events, four are attributed to the Detroit and down-river region and are almost certainly small earthquakes of unknown cause that occurred in Lake Erie. Of the others, the 4 February, 1983 event listed for the Kalamazoo area is really a rail accident in LaPorte, Indiana (Sleep, 1981). The 19 May, 1906 Grand Rapids event is a powder mill explosion in Kenosha, WI. The remaining ten events are listed below: Wenona 43.7*N 83.9*W 6 February, 1872 8AM IV (Intensity) Port Huron 43.0*N 82.5*W 16 March, 1922 III Morrice 42.8*N 84.2*W 22 February, 1918 IV Niles 41.8'N 86.3*W 31 October, 1897 ? St. Joseph 42.1*N 86.5*W 10 October, 1988 IV Kalamazoo 42.0*N 85.5*W 25 November', 1982 ? Coldwater 42.0*N 85.0*W 9 August, 1947 VI Adrian 41.9'N 84.1*W 27 January, 1876 ? Lansing 42.8*N 84.6*W 2 February, 1967 1AM IV 2 events The first three events are all in the spring and may be due to ice break-up in Lake Huron. The Wenona events (s) may also be misreported earthquakes from Ohio. There is no information on the Niles, St. Joseph and Adrian events. The Kalamazoo and Coldwater events were instrumentally recorded and are real. The Coldwater event is the largest event reported in Michigan and was felt at intensity IV in the Lansing area. These two events probably lie on some fault line and could produce earthquakes of magnitude 4 or so in size. Intensity IV is defined as "during the day felt indoors disturbed, walls make creaking sound. Sensation like heavy truck striking building. Standing motor cars rocked vio-lently." The Lansing events are enigmantic. The source for this report is not known, and the only reference made to it derives from the 1967 edition of United States Earthquakes. The Lansing State Journal reports nothing on this date or the several thereafter. This date is just after the major snowfall of 1967 and it is B-8 Revision 1 6/84 L
. . s .
i i test boring no.19 i elevation 854. 20 ft dth legend description ,
~ firm, moist top soil compact, moist mediur n
{ brown sand 1 e firm, moist sand and brown clay 6 sand and pebbles
~
s stiff moist sandy brow a 8 clay, sand and pebbles . i
~
10 very stiff moist i
~
l2 sandy blue clay, sand and pebbles R , E o 18 l -
~
[0 ' stiff moist blue clay 27 sand and pebbles
- occasional streaks g a of sand - O ,
32
\ :
l l Figure 4. Earth Profile in Immediate Area of Reactor Site l l B-9
, i possible that a large amount of snow fell off of a roof and awakened some people.
It would seem likely that any other phenomena would have made it into the local paper. However, this is only speculation. More likely is the detection or feeling of out-state earthquakes. On 27 July, 1980, a magnitude 5.2 earthquake occurred near Maysville, Kentucky. This was felt at intensity V in Detroit (mainly at Tiger Stadium) and with an intensity of II or III in Lansing. On 19 September, 1884, a moderate earthquake occurred near Colombus, Ohio and in March, 1937, several earthquakes occurred near Anna, Ohio. Maximum intensity was around VII or VIII (magnitude 5.5?). In the Lansing area, this was probably felt with an intensity of IV to V. Thus, from local earthquakes the maximum intensity that would be felt in the _ Lansing area is probably about IV. From external (out-state) earthquakes, however, there is the possibility of intensities of up to VI in the region. Hydrology The reactor site area is drained by the Red Cedar River (1400 feet North) an the Grand River (4 miles West). Ground water is found approximately 12' below the surface of the reactor room floor. Ground water in this area moves very slowly through the components of the glacial drift. It is estimated that the ground water moves above 0.01 in/ hour through the sand gravel / blue clay mixture found in the area of the reactor pool. Surface water outside the Engineering Building is directed into the Univer-sity storm sewer system. The University storm sewer system is directed to the Red Cedar River. Water in the Red Cedar River is periodically monitored by the Office of Radiation, Chemical and Biological Safety. The Red Cedar River is not used as source for human consumption. Facility Description The Mark I Triga reactor is housed in Room 184 of the Michigan State Univer-sity Engineering Building. This structure is a 3 floor concrete structure with block walls covered with brick veneer and was constructed in 1960-1962. The building is used for faculty and administrative offices, as well as instruction and research and is of essentially fire proof construction. Room 184. the reactor room, is located on the first floor in the southeast corner of the building. The attached floor plans (Figures 5,6,7,8 and 9) show the room location in relation to rooms in the same wing of the Engineering Building. Adjacent to the room are B-10 Revision 1 6/84 i_
undergraduate teaching laboratories on the north and south sides: a hall sepa-rates the room from faculty offices on the west side and the east side of the room is an exterior wall which faces a parking lot and street. There is no basement beneath the north half of Room 184 and it is here that the reactor well located. The south end of the room covers a machine shop in the basement (Fig. 10) and sufficient distance is maintained'between the reactor core and this area to be equivalent to a minimum of 10 feet of concrete. Thus the shop is not a radiation area (radiation levels are less than 0.25 mr/hr). The second floor over the reactor areas is a classroom (Room 284) and the reactor pit has been deepened from the usual 21.5 feet to 24 feet 8 inches to insure that the radiation levels in this room are sufficiently low to permit free occupancy of the area. Thus the - design of the facility is such that only Room 184 is a restricted operational area. Room 184 (Figure 11) is a 25 x 30 foot area with 3 painted block walls, one painted brick wall, and concrete floor and ceiling (12-feet high). The outside wall of the room contains a continuous row of five foot high windows. Four 16-inch x 42-inch sections of the windows can be opened but would normally be closed daring reactor operation. The opposite side of the room has fixed sash windows 4 x 12 feet into the hall and a 6 x 6-foot door. Adjacent to and entering into the room are three small rooms. Room 184A is a chemistry laboratory used for chemical preparation and radio-chemical separation. Room 184B is an instrument room used for sample counting. Room 190 is the offfee of the reactor supervisor. A 9 x 15 foot control room is located at the end of the interior hall leading to Rooms 184B and 190. The reactor console is housed in this room which has glass windows to permit viewing of the reactor area. Ventilation into the facility is derived from two sources. A unit ventilator installed in the wall of Room 184 draws fresh air from the outside, heats it to the desired temperature and exhausts into the room. In addition, fresh air from the building air supply enters Rooms 184B and 190 at 200 cfm through ceiling ventilators. This air is dumped into Room 184 through a pneumatically operated damper in the control room wall. All air in Room 184 is exhausted through a continuously operating chemical hood located in Room 184A. Exhaust from this unit (at approximately 700 cfm) is through a duct to the building roof. All ventila-tion is destinad to be closed in case of emergency and exhaust from the room in that instarce wa.uld take place through an absolute filter system (in Room 184A) to the building rcof, maintaining a negative pressure on the reactor room (184). B-ll Revision 1 6/84 L
Lab Off Lees Lab / Offices Shop - g 8 ' Storago M T*
" Rooms 18 & 19 -
q { . g. (Bathrooms) . .J
. z p , . . , . M C Z - m , .D -
c. L
, . O O
m i LA. CD
' " tt$
t c
~
u 3
, z d, .e- = = -, w w w C . * ' C y
C
-> c 6 U Q I , b o sk g e
O C w h, m z D
,g C3 5 o C I %*u 1 u B "J .a. ~ ~
g . h 43 = ew w cJ O W. C o ~ c. 3 E C3 v ozm m-m 3 52
.;; e G m o: - -
ec r ww c w M. . g 5 d z w B-12 Revision 1 6/84
4 FIRST FLOOR ENGINEERING BUILDING . . c -s
/963 - , _ i b 2~
d' PEF "a m _ , A_ . E =
m seta".es I - I..- ....,3 -y - ... _ g ... ... E 88 0 t,n _ . _ ,__
C ,=N '"
, i l I .: ss 3 ,,, \ &
4 W 2 at4A
- sS6
{ l y y _ 1>mp-i-t- . e .u . g .g.c _._.._,._____
. . . I ,;. ... T .c. .,,......g.]. ird-,,.
{ _ v -- g
-- ~ ~ - ,,, ~, - ,g ' ]gH -;, _g r 'a 7*O - i_
l _
,n
_ l I . I _
.a u
reactor e co Engineering Building Floor Plan Figure 6. f
_ ~ e b . m
. . n # > .t i .[L ' $i g };$ .
wl** r sl,u3L
- k. .
1 l 1 cm d- .
'~
m=
- l i
F g^l F
."' n a
T. F- L y^l l P F F ~ o o r F-- l F g
' - n y[.
i d l 7 i ue Br u g g
. ni iF r . e e
i n g n E N
= .
G . N
/ .
D - RIL . OU OB L FG3 , ' D/N 6 NR9 . OE/ CE s EN/ m S G N u_ E j
.4n j@ *- > R$
F
2 i! _ rm t - I i L,_I I I d! - ! ._ms
! ;:ei. ! $1 lil J a; E
g ,- 1 -. ,_ m.r. ._ , r . n, _ a Mk #
- j
. .N_
a e
.e ::
2 a k a+s s=15 .. l y 8 k
.-_, gtj-)
b> b i - 1J l : c j_j i .3 _ M I ' Pp 5 I]- +J 4 & tir- c
.J l [ .5 4 1 2
a j m T -
=
f
- -I .5 s. ~~J * %
S c 3 =
-Q l , <
c
~
ta Z g a p ! u 91 , R
~ +1 - ,-
Q T a l kN W Ug g OD ' - o Q3 , QNh Oi Ma I 'i
%Qs N
y kh I D E l G TJ l l %q 7 ' ', 3 y , l l Figure 8. B-15 Revision 1 6/84 L_
o . MSU Engineering Building (Southeast Wing) Offices Offices J- {p g 4 b= , . == - . J A-W _ . _ . _ . . _ _ _ _ _ . _ , _ _ . _a _ _ - - - - d, . 394 -386 384 382 380 376 372 Res P.es Class Class Class Tab n_ lab lab . Lab l Lab lA ; m . .g 3rd Fluce Offices Officee _ rt.. I sg -
.,, Cu a ._ . - . x _ . _ . . . . _ "- d -
a I278 274 .T - 294 290 284 282 Class Res Class Research Res Research Lab lab Lab Lab Lab Lab 2nd Floor m W 7 N I Offices - Offices
, l- . . . L ,1.I.1, ' a =_. = m . . . =d . 1 1 L -[___._L __ s_ u 198 $84 O 182 172 IClass Lab _.
Res Lab l Class Lab p i Reactor Lab lst Floor l L . I
- L
~
ll,Eng:ineer,ing _ Machine. Shop g' g - Reautor a UnEx UnEx , , Basecient Figure 9. B-16 Revision 1 6/84
i grating
- - " a 7 g, l
- O ;
o 3: > O o 0 if , a . ai, I t o o _ O o o O g
. basement O Q fuel storage pit >
9 7 g o y s O o o t b o o o o o , o o : 6'6" : O O o I 16'O' 24'8" g o t O reactor tank 9 0 o a-C o O o I l o w teel a caisson D O I o l l .- o -- I8" ~ l
- O 3
,r j 24" 4 -
4 4 e o min . . . a i 4 13'2" : f Figure 10. North-South Section through Reactor Pit B-17 Revision 1 6/84
- 4 5'
2 y , l t . l ue ag . _ r ovar r e t _ o g o , o t o sgte o t at f c rl f . it s ass a e ou t a 1 . e r pcodp e r sv e 1 .
= ' ct ni _
3 a sap " _
, 8 /
9 O0 I 1 7 l e _ 4 8 ai
. n a 1 / t n
3 c s e e 0 g m as v 3 , o t m o r e oP i n o R tI o .- i .sP uE R - e r l o o t s c n a o e c 'R r 4 f o n 0 > a l 9 1 P r m o R o o A 4 8 1 0' l F o
} ^
m 8' . 1 o 1 1 B o 4 R e 8 ' r i u t g r r d i o o F o o h R 4 0 o 0
- 1 1 4 0 1 1 n
eb E1m oa t
- gE
The reactor core is located in a 6 1/2-foot diameter by 25-foot deep open pool in the north central area of Room 184 as shown on the enclosed sketch' (Figure 12). No pneumatic transfer system is present. Design Bases (a) Reactor power: 250 KW steady state , 250,000 KW (1.4% If) pulsing' . (b) Reactor water temperature: 122*F or 50*C maximum (c) Restricted areas: all areas of the building except room 184, are unre-stricted (i.e., radiation levels less than 0.25 mrem /hr). Further, the exterior of tha building is an unrestricted area. (d) . Room ventilation: 2 air changes per hour minimum (700 cfm). (e) Shielding surrounding core and tank: - (1) 1 1/2-foot concrete around tank to reduce ground activity to permissible levels (2) 10-foot concrete (equivalent) from core to unrestricted access areas (f) Emergency vent'ilation: doors and windows weather stripped. Capability of closing inlet air sources and diverting exhaust air through absolute filter in case of emergency. Air exhaust 150 cfm through this filter. (g) Reactor fuel temperature: 500*C maximum. Design Details (a) Reactor (1) Introduction The TRIGAl reactor was developed by General Atomic Division of General Dynamics Corporation for use by universities and research institutions as a general purpose research and training facility. Using U-ZrH1 ,7 fuel, the reactor is designed for steady-state operation at a power
- level of 250 kw (thermal) and for routine pulsed operation. The total load.ing of this TRIGA reactor core is a maximum of 2.25% 6k/k ($3.00) excess reactivity above a cold, critical, compact condition. Pulsed operation is limited to rapid insertions of up to 1.4% ok/k.
As used in this document, a pulse is defined as a step insertion of an amount of 1 TRIGA trademark registered in U.S. Patent Office. B-19 Revision 1 6/84 L
^ ! i l
CONTRQL ggg gggyg i R E AND IN0lCATOR f g I l
* .i.
I
,_p - \
p?.f* N . CENTER- ,
,,9 l 1
CEAnnEL :ig.: E A$$EMBLYr I [:1gg&' TN'i .s Aid 'f b, ~) PNEUMAllC Q* ay . 2 1RANSFER l i t
$151Eu ,
((h (not presenti)~ ' - _; lh _' - 8
~ f.f ' ' ' , ~- ~; - .y ;. ; > ' R.%., y Y ;
T -- 'Yk. [ I ['l[ El- , [' l
. g ,$h h[hb[, .y jf* ,
j
- .e;Q p $'~1^: $
I is010ft .y - ; AIMOVAL TU8E I ] CENTIAL'9*%'N l IIPfllurgyAt A.
.4 Tuff.
4 .i . ' ,
;~,-
t C3NTRQL' l
~
i ~ R3B - 4 Ts ElfllCICR ROTARY SPECIMEN RACK ALUMIN 83 TAug.
) ' !
- r. !
j S-,
*l ,g, .
CNAWttas .
- g. ., ,
. . s;c l
Figure 12. TRIGA Mark I reactor [
, B-20 Revision 1 6/84 l
excess reactivity between 0.75% and 1.4% 6k/k. A 1.4% 6k/k pulse yields a burse having a prompt energy release of about 8 Mw-sec, a peak power not to exceed 300 MW and a pulse width at half maximum of about 30 msec. The safety of the TRIGA reactor lies in the large prompt negative temperature coefficient that is an inherent characteristic of the uranium zirconium hydride fuel-moderator material. Thus, even when large sudden reactivity insertions'are made and the reactor power rises in a short period, the excess reactivity is compensated for automatically because the fuel temperattee rises simultaneously so that the system returns quickly to a normal power level before any heat is transferred to the cooling water. The inherent prompt shutdown mechanism of TRIGA reactors has been demon-strated extensively during many thousands of transient tests conducted at the two prototype TRIGA reactors in General Atomic' laboratories in San Diego. These tests, using aluminum-clad, U-ZrH l .0 elements, involved step insertions of _ reactivity of up to 3.1% 6k/k. This demonstrated safety has permitted the location of TRIGA reactors in urban areas for other research reactors of similar power level and excess reactivity. This reactor core consists of a lattice of cylindrial stainless steel clad U-ZrH1 ,7 fuel-moderator elements and graphite (dummy) elements. Twenty percent enriched uranium is used. A 1-foot-thick graphite radial reflector surrounds the core and is supported on an aluminum stand at the bottom of the tank. Water occupies about one-third of the core volume. The power level of the pulsing TRIGA reactor is accurately controlled with three control rods: a regulating rod, a shim rod, and a safety-transient rod. Four instrumentation channels monitor and indicate the neutron flux and power level and their rate of change. The prototype TRIGA reactor attained criticality at General Atomic's John Jay Hopkins Laboratory for Pure and Applied Science in San Diego, California, on May 3, 1958. Reactor Description TRIGA Mark I Structure The TRIGA Mark I reactor core assembly is located near the bottom of an aluminum tank placed in the ground and surrounded externally by concrete. Figure 7 has shown a typical Mark I installation. B-21 Revision 1 6/84
. o Reactor Tank The rector tank for the Mark I reactor is welded aluminum vessel with 1/4-inch-thick walls, surrounded externally by steel-encased concrete. The tank has an outside diameter of approximately 6.5 feet and an overall length of approximately 25 feet. The tank is waterproofed by continuous welded joints. The integrity of the joints is verified by radiographic testing, dye-penetrant ,
checking, and leak-testing. The outside of the tank is coated for corrosion protection. An aluminum channel, used for mounting the ion chambers, fuel storage racks, underwater lights, and other equipment, is welded around the top of the tank. Demineralized water in the tank provides approximately 20 feet of shielding _ water above the core.
~
Center Channel Assembly and Reactor Tank Covers , The center channel assembly across the top of the reactor tank provides support for the drive-and-indicator assembly for the isotope production facility, control rod drive assemblies, and tank covers. The top, or a portion of the top, of the reactor tank is closed by aluminum grating tank covers that are hinged and installed flush with the floor. A sheet of Lucite plastic attached to the bottom of each grating section prevents foreign matter from entering the tank but still permits visual observation. Basic Reactor Components a) Reflector Assembly The reactor core and reflector assembly (see Figure 13) form a cylinder approximately 43 inches in diameter and 23 inches high. The core consists principally of a lattice of fuel-moderator elements, graphite dummy elements, and control rods surrounded by the graphite reflector. The reflector is a ring-shaped block of graphite that surrounds the core. It is 12 inches thick radially, with an incide diameter of 18 inches and a height of 22 inches. The reflector is encased in a leak-tight, welded aluminum can te prevent water penetration of the graphite. A "well" in the top of the graphite reflector is provided for the rotary specimen rack. The reflector assembly, which is supported by an aluminum platform, provides support for the two grid plates (Figure 13). B-22 Revision 1 6/84 c
l f I l l l
)
l
,'~ I ..t,. ;s?L ' l
[- ; g .E
' IR'.' j ;(T N .', DNBhikh
l i. il$j.t' *g;;. ? yy e f. ~ i 1 5. J - P :.
' IL $$ is0 TOPE I CONTROL-ROOg 'b d I ;f. ., . ~l .s REMOVAL TUBE ' ~~
GUIDE TUSE ,
.- ,, , ,{,"; ' ;{
u .h ~: .: m . ,s . .
;j*: ' .[} '
i - ; __, l
; <- , 2 .
i, . l [N 10Ng ' :; .i , ;f * -
'~ E, l CHAM 8ER [ -t ' .. TARY I . .
- l' ' ClMEN RACKt I
, [. . .
J ) ( * ,' ."' l l CENTRAL- l THIMBLE A s. FLECTOR FUEL ELEMENT 4 I 5 i-l,
, . j e
l 1 Fig. 13. Cutaway view of core and reflector assembly B-23 Revision 1 6/84 L
The reflector obtained from the University of Illinois has several pene-trations corresponding to the location of beam ports. These represent " holes" in the graphite and are not filled. The one penetrating beam port in the reflector was capped and sealed before installation. Four vertical tubes attached to the reflector assembly permit accurate and reproducible positioning of the three ion chambers and the fission chamber. The top grid plate provides lateral positioning of the core components. It is made of anodized aluminum and contains 91 holes approximately 1.5 inches in diameter; these holes are distributed in five circular rings about a center hole. An anodized aluminum bottom grid plate, in addition to providing lateral spacing between the fuel-moderator elements, supports the entire weight of the . - core.
~
b) Fuel-Moderator Elements , The active part of each fuel-moderator element, shown in Figure 14, is approximately 11.4 inches in diameter and 14 inches long. The fuel is a solid, homogeneous mixture of uranium-zirconium hydride alloy containing 8.5% by weight of uranium enriched to 20% U235 Currently'eight 12% by weight elements are also in the core. The hydrogen to-zirconium atom ratio is approximately 1.7 each element contains about' 33 grams of U235, Each element is sealed in a 0.020 inch-thick stainless steel cladding and all closures are made by heliarc welding. Two 4-inch section of graphite inserted in the can, one above, and one below the fuel, to serve as top bottom reflectors for the core. Stainless steel and fixtures are attached to both ends of the can, making the overall length of the fuel-moderacor element approximately 28.5 inches. The fuel element cladding is stainless steel to retard wear and corrosion. The lower end fixture supports the fuel-moderator element on the bottom grid plate. The upper end fixture consists of a knob for attachment of the fuel-handling tool and a triangular spacer, which permits cooling water to flow through the upper gird plate. The weight of a fuel element is about 6.5 pounds. c) Instrumented fuel-moderator elements Instrumented fuel-moderator elements, shown in Figure 15, are provided with the core of each IRIGA pulsing reactor. These instrumented elements have the same dimensions and fuel material as standard elements, but they contain three chromel-alumel thermocouples embedded halfway between the outer edge of the element and B-24 Revision 1 6/84 E
1 t i 9 t r ' P V announre waaso ovos
~g N%y '
k% ... ars ssi see ' ser see 2 ' i V Lc45755 EL-1249 Fig. 15. Typical TRIGA fuel element B-25 Revision 1 6/84
l s s
/ h, ' ~
n Figure 15. Triangular Spacer g hsneh FM me Graphite End ' Reflector Fuel Moderators Graphite End Reflector
~ . I 6 . I-i Stainless Steel Cladding
- i hh gg ms
. ,i.
p -q ! U Y M l [ 1.478
=
l l
/sc 'l l ^
t' l B-26
its vertical centerline. They are located 1 inch above, and 1 inch below and at the horizontal centecline of the fuel. The tube that leads from the fuel element - is sealed with an aluminum plug containing holes for the thermocouple wires. Soft solder flowed in on top of the plug seals the holes around the wires and between the plug and the tube. The wires lea'd from the fuel element to the water in aluminum tubing. - d) Graphite Dummy Elements Graphite dummy elements are used to fill grid positions not filled by the . fuel-moderator elements or other core components. They are of the same general - dimensions and construction as the fuel-moderator elements, but are filled ,_
~
entirely,with graphite. e) Neutron Source , The neutron source consists of a mixture of Americum and Beryllium, double encapsulated to ensure leak-tightness. Initial strength at manufacture was 3 curies. This source has a nominal outside diameter of approximately 0.7 inch and a height of 0.7 inch. The neutron source holder (see Figure 16), is the same general size and shape as a fuel element: thus, it can be placed in any vacant fuel or graphite element location. The upper and lower portions of the holder are screwed together to enclose a cavity that_contains the source. A shoulder a the upper end of the neutron source holder supports the assembly on the upper grid plate. The current source is 1.88 ci. g) Experimental and Irradiation Facilities A rotary specimen rack, (Figure 17) located in a well in the top of the . graphite reflector, provides for the large-scale production of radioisotopes and for the activation and irradiation of small specimens in a dry atmosphere. All 40 positions in this rack are exposed to neutron fluxes of comparable intensity. Samples are loaded from the top of the reactor through a water tight tube into the rotary rack using a specimen lifting device (essentially a fishing pole with a grapple mechanism on the end of a power cord). The rotary rack can be turned manually o: by using a motor drive located on the center channel assembly. The TRIGA reactor is equipped with a central thimble (see Figure 12) for conducting experiments or irradiating small samples in the core at the point of maximum flux. It consists of a 1.5-inch OD aluminum tube that fits through the B-27 Revision 1 6/84
l i
- i l
E
- l I
l ! j ! ~ i l l l
' f i * ~ ~ .
l O O l I i i { l l I l I l l
/
l Fig. 16. Neutron source holder l B-28 Revision 1 6/94 l
\ ATERTIGHT W HOUSING ,
A-A ORIVE CH AlN A-A . _ h
-.g,- 28 IN. ,
h DRIVE GE AR , PLAN VIEW DRIVE SHAFT ISOTOPE LOADING AND j REMOVAL TU8E
~ - '
POS*TIONING SHAFT
,i r LIFTING LUG 2
6' - ~ h ' -
*,_,7 b -c \ 2 FT L ANNULAR BALL BEARING '#'
141N IC IN b' S A M PL E RECEPTACLE
/ .x WATE RflGHT HOUSING f U
- m 2-1/2 IN SECTION A-A Fig. 17. Rotary specimen rack schematic B-29 Revision 1 6/84
center hole of the top and bottom grid plates. Holes in the tube assure that it is normally filled with water; however. a special cap may be attached to the top _ end, compressed air applied, and the water column removed to obtain a cell-collimated beam of neutrons. f) Reactor Water Cooling and Purification System (Figure 18) - The water system provided with the TRIGA reactor serves five functions it:
- 1. Maintains low conductivity of the water to minimize corrosion of all reactor components, particularly the fuel elements. .
2. Reduces radioactivity in the water by removing nearly all particulate and soluble impurities. , _
- 3. Maintains the optical clarity of the water. ,'
- 4. Provides a means of dissipating the heat generated in the' reactor.-
S. Reduces the radiation level due to nitrogen-16 at the top of the reactor , because the~' vertical convective core water currents are deflected by the downward, slanted discharge of water through a~ diffuser nozzle on the water system's tank inlet. The system consists principally of a pump, fiber cartridge filter, a mixed-bed type of domineralizer, a flow meter, and a heat exchanger connected by suitable aluminum piping and valving. A surface skimmer is provided to assist in maintaining the cleanliness of the rector-tank water surface. Probes are provided for measuring the temperature and conductivity of the waterlas it passes through the system. Reactor heat is removed by circulation of pool water from the reactor pool through the tube side of a stainless steel heat exchanger. The pump and exchanger for this operation is located along the north wall of the reactor room. Piping for the pool water is threaded aluminum and is provided with vacuum-breaking holes to prevent siphoning the pool water in case of line rupture. A fraction of the water flow is directed through a mixed bed ion exchange column for purification and then back to the reactor tank. The temperature of the pool water outlet as well as the electrical conductivity of the water is measured and displayed at the reactor console. The ion exchange unit is located in Room 184 to permit local shielding and controlled access in case the radioactivity on the bed becomes excessive. B-30 Revision 1 6/84
To Cooling Tower Secondary Water (27 psig) (150 gpm)
'r epm Orifice R
Temp. Probe 3-10 gpm - Conductivity ll g 8 g Probe u
- _ 20 ps -
Demineralizer Fliter O ' w - Conductivity Prob' p
._m. Vent Holes + ,
(20 psi) -
;L CORE PRIMARY COOLING SYSTEM i
Figure 18. B-31 Revision 1 6/84
Secondary heat removal is accomplished by circulation of water through the shell of the-heat exchanger up to a forced convection cooling tower located the , penthouse on the building roof._ The circulation pump for this stream is located in the basement pipe tunnel. Motor switches and indicator lights are provided at the control console to insure the operation of the cooling system. g) Control Rods Each of the three control rods operates in a perforated aluminum guide tube.
'The shin and regulating rods are sealed aluminum tubes containing boron carbide ,
(in powdered form) as a neutron poison. The upper end of each control rod screws - into a control-rod-drive-assembly extension tube. Each control rod is approxi- .- mately 20 inches long. The regulating, shim, and safety-transient rods are - 1.25-inch-OD; the vertical travel of the control rods is approximately 15 inches.'
~
The safety-transient rod, which is completely out of the core during' normal . .
~
steady-state operation, is worth approximately 1.36% Sk/k. The reg and shim rod
~
worths are 1.30 and 2.12% Ak/k respectively. The total excess reactivity in the core does not exceed 2.25% ak/k. The maximum possible reactivity insertion rate associated with the withdrawal of any rod except'the transient rod shall not' exceed 0.2% Sk/k see or 28c per second. h) Rack-and-Pinion Rod Drives Rack-and-pinion rod drives, shown in Figure 19, are us'ed to position the shim and safety rods. Each drive consists of a single-phase, reversible motor; a magnet rod-coupler, and a rack-and-pinion-gear system. The pinion gear engages a rack attached to a draw tube supporting an electromagnet. The, magnet engages an iron armature attached above the water level to the end of a long connecting rod that terminates at its lower end in the poison rod. The magnet, its draw tube, the armature, and the upper portion of the connecting rod, are housed in a tubular barrel. The barrel extends below the reactor water level with the lower end of the barrel serving as a mechanical stop to limit the downward travel of the control rod assembly. Part-way down the upper portion of the connecting rod, i.e., just below the armature, is a piston that travels within the barrel assembly. Since the upper portion of the barrel is well-ventilated by large slotted open-ings, the piston moves freely in this range: but when the piston is within 2 inches of the bottom of its travel, its movement is restrained by the dash pot action of the grated vents in the lower end. B-32 Revision 1 6/84
MAGNET WIRE CONDUlT MAGNET 00WN ADJUSTMENT SCREW-MAGNET DRAW TUBE MOTOR BIAS ADJUSTMENT CENTER SWITCH ROO DOWN LIMIT SWITCH MOUNTING PLATE N ' MAGNET WIRE CONDUIT ' PULL-ROD SPRING
,g MAGNET UP LIMIT SWITCH ,,- s y 1 ADJUSTMENT SCREW . _ ' ~
MOTOR COVER , L PUSH ROO
~
8 LOCK PULL-ROD HOUSING r
~ = BARREL , ~
MAGNET DRAW TUBE MAGNET I PULL ROD LOCK NUT i FOOT =% --q I r ARMATURE
) CONNECTING ROD v
Fig. 19. -Rod drive mechanism, showing components and adjustment locations l B-33 Revision 1 6/84
Controls and Instrumentation _ a) General the pulsing TRIGA reactor is capable of operating in two standard modes: Mode 1 Steady-state operation at power levels up to 250 kw thermal. Mode 2 Pulsed operation produced by rapid transient rod withdrawal that . results in a step insortion of reactivity of up to 1.4% 8k/k ($2,00). The reactor is operated from a console (see Figure 20) that displays all , pertinent reactor operating conditions. The control system consists of four power-measuring channels utilizing ,, _ three ion chambers and one fission counter as well as monitors for fuel temper - , ature, cooling water outlet temperatures, and water conduct-ivity. Test circuits and calibration signals are provided for the log count-rate, log-n, and linear - - power-level channels'. The rack-and-pinion control-rod drives and the pneumatic ' safety-transient rod drive are controlled from the console. Manual scram is possible for the control rods individually or as a group. A helipot is used on the regulating and shim rod drives to provide indication of the control rod position on the console. A selector switch is provided for steady-state and pulsing modes of oper-ation. b) Modes of Operation
- 1) Steady-State Operation. For steady-state operation, the control rod are withdrawn slowly by manual control until the desired power level is reached. A diagram of the TRIGA reactor control system is given for steady-state operation in Figure 21.
The count-rate channel, using a fission counter and log count-rate chassis, provides power indication over 4 decades from below source level. This channel is provided with a source interlock that prevents rod withdrawal unless source level is above a preset level. Operating ranges for the various detectors is presented in Figure 22. A log-n channel using a compensated ion chamber covers the power range from less than 10 watts to above full power, and is read and recorded by one pen of the ll-inch, dual-channel recorder. A period circuit indicates reactor period from
-40 to a to +7 seconds.
B-34 Revision 1 6/84
l 1 l Log and Linear Power
~
l
' L e'":'-- [Y , 'g: '-r N. ' d . S _.
4 l g , .%y Count - -
~ % Power Meter i ,*E'Nh.,fh j' *,*
- Rate Meter l
, ~ ' , - M's IO,d, /L b. . - ..3 , - ~e ' . . . g .. -- .
- Selector Switch
> &gg.i.iq:,,'_ 'hY,Y$ E9 ' ' U .~ ekO$i '< ' ' fl_l '
Y K. a Fuel Temperature a ,,y e . ( 7,*:+< '/ -
- t. , e .,
- E I + b jet s*
Period ' l Meter
-E*'
O '"
$'
- Gnductivity f[~ :$' i
' ~
Test L s- __=.
~f a u-f-
_w T- r :
%Wi@h.Rt?5{~a.em-- .., . a v- = * ' = ' ' * * * '~ "-V 9 WH Circuit t .T sih 1'g'SF* ' ' , \ .,
c 1 d Controls
-kf f o ye '
- + i.wi(h';'. x;%
~ 'f :a4.. ):-W.;e . L,$@.,, , = , t ..
, V- -,tz:s wmXX.n:M
,' y ' :
c ~ j 1:* 7. 7rk;~ -
$. {'$
1 i Fig. 2Q TRIGA control console, front' view I
' t '
O Set Points Fission Pre- Amplifier E 2 cps (min) Counter Amplifier Count Rate , g interlock 1 Log n Recorder Compensated ion Log n Period n 7 sec (min) Chamber Amplifier Circuit Compensated ion Amplifier 7 i Chamber Linear PWR 3 g g L + Recorder l SCRAM $ To Rods% Power
. Ion Power Level .I -! -- h 110% of Scale Chamber Monitor i l_ -- 7 k (" *)
r-- - - - - - g Power Demand 1 F - - - - - - -
'- +l - herl- - -*- Rod I -{- - - - ____j Regulating I t.Iont. col. _ _ I l I Fuel Temperature A 450*C (max) c -
1 i t
- o E h r i 50*C
" Temperature Probe i r
o . (Administrative) , o , j r ,
, Figure 21. Block Diagram of Reactor ' Instrumentation
- g for Steady-State Operatica , ,
n ' 8 l < ,
i i f 10' - I T ' lo s _ l L. - UNCOMPENSATED 10y - !ON CHAMBER PEAK POWER ; (PULSE POWER) l SAME CHAM 8ER , O -
- +
' t i
- e. ,
d - -- -- -- [ UNCOMPENSATED - - d ., ION CHAM 8ER k PER CENT POWER .
._ (STEADY-STATE OPERATION) ,
3 : 10 - . i
-COMPENSATED lON CHAMBER [
LINEAR RECORDER ' g , (STEADY-STATE OPERATION) ;
- i m ~~
C
< (
2 id - COMPENSATEDION CHAMBER a 10* C,/SEC LOG n RECORDER I y (STEADY-STATE OPER ATION) l W s . 1 W g - FIS$10N COUNTER 4 COUNT-RATE CHANNEL 16' ~ l 16' - OURCE LEVEL I C /SEC i 16* i Figure 22. Detector Ranges B-37 Revision 1 6/84 ; i
~ - - .--y., -- -m w, , yp--.w-wmm--
7.-,-- ,_,,_y ,_ _,-ym pg.--m-,.--.v,y %S, ,,e ,,pr e-e_gg.,-.-w y_- , -, -m-m--w---.-o-e-g,-ww
A linear micromicroammeter channel provides a power level measurement from about 0.001 watt to full power, with a range switch having two ranges per decade , so that measurement of the compensated ien chamber current may be made accurately. The output is indicated and recorded by the second pen of the recorder. A linear channol scram at 110% of full scale is provided on all ranges. A percent-power-level channel operating from an ion chamber indicates pdwer in the range from a few percent to 110% of full power. This circuit provides for an adjustable-level scram within this range. Fuel temperature at.d cooling water outlet temperatures can be read by means of a meter. At the console a manually operated water conductivity bridge is - provided with two probes to read conductivity at the demineralizer inlet and .. - outlet; the bridge is located on the console.
- 2) Pulsing Operation. After a power level of less than 1000 watts in tr.e " - -
steady-state operating mode is reached, the mode switch is changed to the pulse mode so that the reactor can be pulsed. When the switch is turned to the pulse mode, the normal neutron channels are disconnected and a high-level pulsing chamber is connected to red out the peak power of the pulse. The peak power'is l then displayed on the recorder several seconds after the pulse is completed. Also, changing the mode switch to pulse removes an interlock that prevents application of air to the safety-transien_t rod unless the safety-transient rod cylinder is in the full "in" position and thus allows pulsing to take place. Furthermore, only the safety-transient rod can be moved during pulsing mode operation. In this mode, a scram is caused by excessive peak power or excessive integrated power. In addition, fuel temperature is recorded during pulsing. Fuel temperature can also unitiate a scram. These channels are indicated in Figure 23.
- 3) Detector Ranges. Operating ranges for the detectors using in the reactor are outlined graphically in Figure 22.
c) Rod Control At the console the two standard rod drives and the safety-transient rod drive are controlled by switch-light pushbuttons, which not only control the up or down motion of the rods but also annunciate their extreme positions. In addition. B-38 Revision 1 6/84
~ . - .. . . .
Set Points PULSE PEAK power [ v 1 A M PLI FI E R IO N CHAMSER UNEAR RECORDER
-{ TRIP ! > TO SCRAM SUS I v i 1.OG
- RECORDER FUEL TEMPERATURE 6 i
4 450 C (max) 1 Y w
- WATER TEMPERATURE ^
! TEMPERATURE PROBE t
50*C (Administr.ition) i m E Figure 23. Iltock Dirgram of Reactor Instrumentation for Pulsing Operation l 7 o a w I R .
?
i
? -
8 ',
position indicators with digital readout accurate to 0.2% are provided for the regulating rod and the shim rod. Following a scram. automatic rod drive. Down is , provided for all drives except the safety-transient rod drive.
~
Safety Devices Scrams: '.
- 1. Power level channel, compensated ion chamber micromicroammeter.
- 2. Power level channel, ion chamber, adjusted by operator from 2 to 110% of full power ,
- 3. Reactor period adjustable period scram between e and -7 seconds -
- 4. Manual .-
Ion-chamber power supply failure 5.
- 6. Console power circuit failure -
- 7. Peak power and integrated power in pulsing mode . -
- 8. Fuel temperature.
Interlocks are provided to 1.- Assure minimum. source strength before control rods can be withdrawn.'
- 2. Prevent withdrawl of two control rods simultaneously on manual control.
- 3. Prevent movement of any rod except the safety-transient rod in pulsing mode. _
Ventilation There are two sources of ventilation air and one air outlet for Room 184. A unit ventilator located along the outside wall draws air from outside, filters and tempers it and circulates it within the room. The second source of air is the building ventilation which supplies Rooms 190 and 184B. The air from these rooms flows into Room 184 through a pneumatically operated grille in the control room wall. Both the unit ventilator and the grille are equipped with pneumatic dampers . which can be remotely closed from console in case it should become necessary to close off the room. In addition, at that time, the ventilator fan is turned off. The doors and windows to room 184 from the hall, outside and control room are weather stripped to permit isolation of the room in case of emergency. Air discharge from the room is accomplished through the laboratory hood in Room 184A. This hood is operated at all times and moves sufficient air (700 cfm) to insure at least two air changes per hour through the reactor room. Discharge is to the roof B-40 Revision 1 6/84
of the building at a distance of about 60 feet from the building ventilation inlet. This exhaust duct is equipped with a by-pass filtration system in Room _ 184A which can be dampered into operation remotely from the reactor console. It provides a continuous filtered exhaust from the room in case of emergency and maintain rooms 184 and 184A under slight vacuum. Tne flow rate under filtering , conditions is about 150 cfm versus the 700 cfm normally experienced. The pneu- , matic dampers, ventilator fan switch and by-pass dampers are all actuated by a single switch at the console. Radioactive Material Generation, Storage and Disposal - The total quantity of radioactive by-product material generated within .. - the reactor (exclusive of radioactivity contained in the reactor fuel) has - not exceeded the permissible amounts as specified in the NRC license 21-0021-29. There are two locations available in the facility for storagi , of these materials:
- 1. A storage vault approximately 3 1/2 x 4 x 2 feet in size is located beneath the floor in the unexcavated region of the room. Access to this vault is provided by are movable door in the pit area adjacent to th'e reactor. A 6-inch concrete shield door is provided to further shield the vault if necessary. The vault itself is constructed of concrete has 12 inches of concrete on the roof and south wall. The other walls face into the unexcavated portion of the building.
- 2. Three 10-inch diameter by 16-feet deep fuel storage pits are cast into the concrete adjacent to the reactor pit (see Figure). These pipes can be filled with water and used for high radiation isotope storage or for storage of fuel removed from the reactor. The pits are covered with steel
[ plates and padlocks can be provided to prevent unauthorized removal of the contents. Tha pits are galvanized steel with Amercoat interior coating. Radioisotopes generated by the reactor operation plus any other radioactive material are disposed of following he procedures outlined in the Michigan State l University broad license NRC 21-00021-29 and 10CFR Part 20. l Monitoring Facilities In addition to the safety monitoring facilities described in the description of the reactor, the following items are also used: l l B-41 Revision 1 6/84
t
- 1. Airborne particulate monitor. This continuously monitors the radio-activity filtered from the room air by a fixed paper filter. The filter ,
is changed bi weekly. A suitable alarm system is preset to correspond to a radioactive material concentration less than the permissible content specified in Title 10CFR Part 20. Output from the monitor is recorded on a recorder in the control roon. .
- 2. A remote reading gamma monitor is located at the reactor console with the sensing element mounted at the ceiling above the reactor pool. An alarm .
system is included to identify the existence of an abnormally high , radiation level.
- 3. A second wall mounted gamma monitor is located on the wall adjacent at ,, _
the reactor pool. It has a dial readout and both audible and visual _ alarms. -
- 4. Several ionization and Geiger-Muller survey meters (both self contained _
and lien operated) are available for monitoring the radiation levels in
~
the area around,t,he reactor and storage vaults.
- 5. Geiger-Muller survey meters with thin windows are used to monitor the contamination levels of all equipment and areas in the laboratory as" well as to monitor the personnel and materials leaving the facility.
. Radiation Dose Rates Around Reactor Complete gamma dose measurements have been taken around the MSU TRIGA reactor during 250-kw steady-state operation. Typical measurements are listed below. No neutron leakage has been detected from operating TRIGA reactors except for a thermal' neutron nose of 0.03 aree/hr (15 neutronsem2-sec) measured above the rotary specimen rack drive shaft tube during 100-kw operation.
As indicated below, the measured radiation dose rates are low enough to allow operating personnel to perform experiments at the edge of the reactor tank during full power operation. B-42 Revision 1 6/84
Table 3. Gamma Dose Rates Around Triga Reactor During 250-KW Steady-State Operation . Dose Rate (ares /hr) '. , , Location of Instrument Steady-State Operation
- 1. Surface of reactor tank water 1.0 ,
- 2. I ft. above surface of the pool (floor level) 0.8 -
- 3. At handrail adjacent to reactor tank 3.1 , _
- 4. At c01.!ing directly above reactor pool 0.2 to 0.3 , [
Dose rates apply when the reactor cooling system is in operation. These doses are , l given in milliroentgens (ar). Since only gamma radiation was measurable, mr is the same as area in this case. The roentgen equivalent man (rem) is defined as the dose of any ionizing radiation that will produce the same biological effect as , that produced by I roentgen of x-ray or gamma-radiation. The radiation levels j produced at the floor level in the classroom over the reactor are less than the permissible levels for non-radiation worker as specified in Title 10. CFR Part 20 as measured by film badges located in the. classroom and on the ceiling of the reactor room. B-43 Revision 1 6/84 i
C - Cafety Reviews
~
Several oossible hanard conditions have been assessed with regard to the re'accor. ' It has been concluded that operation of the reactor will not - endanger the public health, and safety. Among ,the analyses performed the following the pertinent: , _
- 1. Loss of coolant accident. .
~
- 2. Fuel element failure in air.
- 3. Reactivity insertion
- 4. Mechanical rsarrangement of fuel.
- 1. Loss of Coolant AIccident The MSTR operates at a maximum of 250 KW h and the presont core ,
i contains 70 elements. The average power density, thus, is 250/70 = 3.57 . KW h per element. A portion of the fuel'contains 12 wtf. uranium and, .. thus, is operated at a 41% higher power density than the remaining 8.5% . uranium fuel. Thus, the maximum power density would be 3.57 x 1.41 or 5.03 - KW per element. Under conditinns speculated to involve the cosplete th loss of power operation. -it is estimated that the fuel temperature would . reach approximately 225*C (see Fig. LCA-1). Under such conditions the, estimated stress imposed on the cladding by internal gas is approximately 1200 psi (see Fig. LCA-2). This stress is considerably less than the approximately 37,000 psi' yield stress for the stainless steel fuel cladding. It is, therefore, concluded that the loss of coolant would not result in the failure of the fuel cladding and that the fission product containment would not be lost. Radiation Levels from Loss of Coolant If it is assumed that the reactor water is suddenly lost, the radi-ation emitted from the contained fission products would potentially pose a threat to personnel in the reactor room and in Room 284 directly over the reactor. The operating floor of the MSTR is 20 feet above the reactor core and the estimated radiation lu~vels from both direct radiation and scattered from_the concrete room ceiling are given'below for various decay times immediately following full power operati,on. C-1 '
, Revision 1 6/84 w _.
2000 . 1800 -
~
C001.ING TIME (SEC
~
0 . 1400 . . .
. 3 +
10 3 1200 L 10 u . o -
.L g .
_q 1000 -~ 5 I w 800 - 5 1 600 - 6
,. /
200
/ '~ ' ' ' ' ' ' ' '
0 30 35 40 45 5 to 15 20 25 O OPERATING P0t!ER DENSITY-Kil/ELEllENT EL-1872 Fig. LCA-1. Maximum fuel temperature versus power density after loss of coolant for various cooling times between reactor shutdown and coolant loss. C-2 5/84
. o C -
5 10 l_ ULTIMATE STRENGTH -
~_,'s s% . \
N . N YlELD STREtJGTH -\
\ .
4
\ .
10 - N - g - - g -- O N ' r . N N .
- \
N N ' \ STRESS IMPOSED O!1 CLAD 1 10' - 2 10 , , , , _, , , 400 600 , 500 1000 1200 TEMPERATURE (*C) El.-1873 Fig. LCA-2. Strength and applied stress as a function of temperature, U-ZrH same tenperature. 1.65 "* * "* "" # # # C-3
s . Calculated Radiation Dose Rates For Loss of Reactor Pool Water Direct Radiation Scattered Radiation Time r/hr r/hr 10 sec 2,500 0.65 1 day 300 0.075
^
i I week 130 0.035 - 1 month 35 0.01 The table indicates that, except for the direct beam from the core radiation exposure in the reactor room would be high but tolerable even - immediately after loss of coolant and that emergency operations could be carried out with limited time of action. - Of greater concern is the radiation levels-in the uncontrolled area,. . Room 284, located directly over the reactor. The distance from the core to - - the occupied area of this room is 30 feet and the radiation levels calculated above (for 18 feet) will be reduced by inverse square
~ '(18/30)2 = 0.36x and the shielding of the concrete floor (approximately ~
6 inches) = 0.2x. On this basis, the direct radiation in Room 284 is estimated to be Direct Radiation Time r/hr . 10 see 180 1 day 22 1 1 week 9 ! 1 month 2.5 These levels of radiation are sufficiently high to necessitate i immediate evacuation of the classroom in case of total loss of pool water. The integrated exposure to personnel in this room as a function of time delay in evacuation is given below. Time, Min. Radiation Dose, R l 5 14.97 l 15 44.77 30 89.07 i 1 45 132.9 f 60 176.3 l C-4 t - .
Evacuation of Room 284 following loss of pool water during or shortly after reactor operation (the case assumed above) could most certainly be done in a time much less than an hour since a reactor operator on duty - could assure building evacuation in such a catastrophe. If pool water were to be lost during non-working hours, a longer evacuation time might be experienced as the result of the time dolay inherent-in-emergency response. The radiation levels would be reduced in this case however since the short ~ lived fission products would have decayed away. As an example, assume a 6 hour shutdown period followed by loss of pool water and a 1 hour evacuation delay during which time Room 284 is occupied. The exposure to a person in ~ such a situation would be 132 R. Such an exposure, although high, would not be life threatening. -- - 4 L i l C-5 Revision 1 6/84 i__
- 2. Fuel Element Failure in Air In this analysis, it is assumed that one of the 12 wt% Uranium fuel elements is ruptured in air after a long (1,000 day) exposure to full power (250 kvth) operation of the reactor. The radioactive material released .
to the air consists of 100% of the rare gases and halogens which, during reactor generation, have migrated to the gap between the fuel meat and cladding. No credit is assumed for deposition of the isotopes on walls, in . pool or in any other manner. , (a) Exposure to reactor room occupants. In this case, the rare gases and halogens are assumed released to the reactor room, and the _ ventilation in the roca is assumed to be zero. A room occupant is
- assumed to remain in the room for 10 minutes while evacuation , ,
~
takes place. The fission product gas concentration in the core operated at 250 kwth for 1,000 days is given below (from Lamarsh, p. 535--scaled to MSTR power output). (Note: core loading 70 elements, power ~ density in 12 we% fuel = 41% greater than core average.) Curies, Single Curies, Single Radioisotope Curies, core Element, Avg. Element 12 wt% Krb5m 28b0 40 56.4 Kr85 98 1.4 1.97 Kr87 5,000 71.4 100.7 Xe133m 400 5.71 8.06 Xel33 14,320 204.6 288.4 Xe135m 2,220 31.7 44.7 Xe135 3,900 55.7 78.6 1131 5,850 83.6 117.8 1132 8,270 118.1 166.6 1133 14,300 204.3 288.0 1134 15,200 217.1 306.2 1 135 13,550 193.6 272.9 9 C-6 Revision 1 6/84
s For fuel element ruptures in air, the gaseous fission product inventory in the gap is estimated to be 1.5x10-5 fraction of the total gaseous fission products (GA 4314). If all of this fraction is released into the reactor
~ '
room (volume 2x108 ) with no air change rate, the concentration of radioisotopes in the room air is: Curies x 106 x 1.5 x 10-5 / 2 x 108 = pCi/ml - Assuming a person occupies the room for a total of 10 minutes following fuel rupture (while evacuation takes place) and that a respiration rate of 3.47 x 10-4 m 3 /sec (Reg. Guide 4) is experienced, it is possible to _ project the personnel exposure and isotope ingestion. The following
' ~
equations were used: _ 1. Whole Body Exposure = MPC (Table 1,10CFR20)
*
- D*
x 9 El yr x- ~ 2000x60cyr"'" - . (Assumes that continuous exposure to 1 MPC is equivalent to 5 rems /yr , whole body dose)
~
- 2. Isotope ingested = conc. of radioisotope x 3.47 x 10 2m x 600 sec, The results of such a calculation for a 12 wt% element are given below.
Conc. MPC 10 Min. 10 Min. Radioisotope pCi/ml Table 1 Dose, mr Ingestion, uCi Kr85m 4. 2 3x10 6x10-6 0.29 0.88 Kr85 1.48x10-7 1x10-5 0.006 0.03 Kr87 7.56x10-6 lx10-6 3.15 1.57 Xe133m 6.04x10-7 1x10-5 0.02 0.13 Xe133 2.16x10-5 1xio-5 o,90 4.50 Xel35m 3.35x10-6 4xio-6(ass) 0.35 0.70 X3135 5.90x10-6 4.10-6 0.61 1.23 1131 8.83x10-6 9x10-9(S) 409.0 1.83 Il32 1.25x10-5 2x10-7(S) 26.0 2.60 I133 2.16x10-5 3xio-8(S) 300.2 4.50 1134 2.30x10-5 5x10-7(S) 19.2 4.78 11354 2.05x10-5 1xio-7(S) 85.3 4.27 845.0 C-7 Revision 1 6/84
Thus, the maximum whole body exposure to a person in the reactor room for 10 minutes immediately following a fuel element rupture in air would be 845 mrems--a value well within the requirements of 10CFR Part 20. The ingestion of iodine isotopes identified above would result in the concentration of the isotopes in the thyroid with a resultant thyroid exposure. The extent of exposure can be calculated by multiplying the iodine ingested by the corresponding internal dose effectivity factor. . 10 Min Effectivity Ingestion Factor Thyroid Radioisotope pCi rem /Ci Dose, rems Il31 1.83 1.486x106 2.72 - I132 2.60 5.288x104 0.14 .- 1133 4.50 3.951x105 1.78 I134 4.78 2.538x10 4 - 0.12 Il35 4.27' 1.231x106 5.25 , Total thyroid dose 10.01 rems This- resultant thyroid dose is reasonable based on the conservative. assumptions made. (b) Exposure to the general public. In case of a fuel element rupture, some of the released radioisotopes would be swept from the reactor room by the ventilation system and discharged through the hood vent into the uncontrolled area. For the sake of the analysis of exposure to the general public, it is assumed that, at the time of the hypothetical fuel element rupture, the ventilation system would be switched to its " emergency" operation in which the exhaust air is diverted through an absolute filter before being vented. Furthermore, the air intakes to the room would be isolated to maintain the reactor room under negative pressure and inhibit radioactivity release except through the exhaust vent. The air flow through the exhaust under these conditions is 150 cfm which represents an air change rate in the room of about I change per hour. The concentration of radioisotopes re? eased from the fuel would be reduced by the air flow through the room. A common engineering cr.lculation for a well mixed vessel assumes essentially complete C-8 Revision 1 6/84
flush of the vessel in 5 volume changes. However, for the purpose of the present calculations, only one room volume is assumed, and, thus, the concentration of isotopes in the room exhaust would be - the same as was calculated above. However, the air is discharged at the roof level, approximately 40 feet above grade. Thus, a dilution due to wind will be encountered.
~
The Dilution Factor due to the building is defined by Lamarsh as: ! DB = cAv where . .
}
e = shape factor, experimentally between 0.5 and 0.67 A = cross section' area of the building _ y = average wind ~ speed , Since the prevailing winds near the MSTR are form the west,'the . .
- r. orth-south area of the Engineering Building is used, thus A = 500 ft x 40 ft = 20,000 ftr ,
v = 10.1 mph = 14.8 f t/sec ( from National Weather Service . Bureau) < .,3, c = 0.5 Thus, DAB = (0.5)(20,000)(14.8) = 1.48x10 5 ft' f*' With a stack flow rate of 150 min (= 2.5 f*'), see the concentration
'5 reduction due to wind dilution will be 1.48x10, = 1.69 x 10-5, The concentration of nuclides will, t.as, be reduced by this amount outside the building. The dose received by a member of the public over an hourl of occupancy may be estimated in a manner similar to that used for occupational exposure given above.
- 1. x Whole Body Exposure = MPC(Table 2,10CFR20) x yr .8760 hrs (Assumes that continuous exposure to IMPC is equivalent to 500 mr/yr whole body dose)
- 2. Isotope ingested = conc. of radioisotope x 3.47x102 *1 see x 3600 sec.
1 One hour exposure assumed because released activity will be dispersed after ' this time. C-9 Revision 1 6/84
e . The results of these calculations are given below for the rupture of one 12 wt% fuel element in air with 100t release of halogens and rare gases in the air gap of the fuel. . I hr dose, I hr ingestion Radioisotope pCi/ml . Table 2 mr Ci Kr858 7.15x10-ll 1x10-7 4.08x10-5 0.89x10-4 Kr85 2.5x10-12 3x10-7 4.76x10-7 0.03x10-4 ~ Kr87 1.28x10-10 2x10-8 3.6x10-4 1.6x10-4 Xel33m 1.02x10-Il 3x10-7 2x10-6 0.13x10-4 I 4.56x10-4 Xel33 3.65x10-10 3x10-7 6.9x10-5 - Xe1355 5.66x10-ll lx10-7(ass.) 3.2x10-5 0.71x10-4 r Xel35 9,97x10-ll 1x10-7 5.7x10-5 1.25x10-4 - - Il31 1.49x10-13 1x10-10(S) 8.5x10-5 1.86x10-7 - r
^ ^
- I132 2.11x10-10 3xto-9(S) 4.02x10-3 2.64x10-4 1133 3.65x10-10 4x10-10(S) 5.2x10-2 4.56x10-5 ,
.' ~
I134 3.89x10-10 6x10-9(S) 3.7x10-3 4.86x10-4 . Il35 3.46x10-10 lx10-9(S) 1.98x10-2 4.32x10-4 L Total Whole Body Exposure 0.080 me, . Similarly, the thyroid exposure from the ingestion of iodines would be: -r Effectivity 1 hr Ingestion. Factor Thyroid Radioisotope pCi Rem /Ci Dose Rems . Il31 1.86x10-7 1.486x106 2.76x10-7 4 1.40x10-5 I132 2.64x10-4 5.288x10 1 Il33 4.56x10-4 3.951x105 2.0x10-4 Il34 4.86x10-4 2.538x104 1.23x10-5 Il35 4.32x10-4 1.231x106 5.0x10-4 Total Thyroid Dose 7.58x10-4 Rems These calculations indicate that the exposure to the general public as the result of a fuel element failure in air after extended reactor operations would be negligible. . C-10 Revision .1 6/84
p Bibliography Lamarsch, John R., " Introduction to Nuclear Engineering," Addison Wesley, December, 1977. _ USNRC Regulatory Guide 4 Sienad, M. T., "The U-ZrHx Alloy; Its Properties and Use in Triga Fuel," G. A. Technologies Report E-ll7-833 (February,1980). .
~
C-11 Revision 1 6/84
- 3. REACTIVITY INSERTION l
_ i The present MSTR core consists of 70 elements, all of which are stainless steel clad U/ZrH with a nominal H to Zr ratio of 1.7. Eight of the elements are 12 wt % Uraniu'm (<20% enriched) while 62 are 8.5 wt % Uranium (<20% enriched). The 12 wt % elements are located in the B and C - rings of the core and two of these (one each in the B & C rings) are e instrumented with chromel-alumel thermocouples. Experiments conducted at MSU involving the rapid insertion of 1.39% . Ak/k into the core described above by means of a pneumatic control rod results in the production of a power pulse of approximately 258 MWth and an ,_ integrated power output of about 15 MWsec. The temperature measured in the
~
instrumented fuel elements located in the B and' C rings,12 'wt % fuel,1,s. - approximately 275*C. It is expected that this fuel concentration in these , locations would experience the highest neutron flux and temperature. By comparison, experiments conducted at General Atomic (GA6216) with a Stainless ' Steel Core containing 8.5 wt % (<20% U235) Stainless Steel Fuel . and subjected to pulses of up to 3.5% Ak/k reactivity insertion compared the temperatures produced. The temperatures in both the B and D rings were measured and a linear relationship between the fuel temperature and the quantity (Ak/8-1) was observed. (B = effective delayed neutron fraction = 0.7% for this fuel). Although experiments were not conducted at Ak = 1.37%, the temperatures produced may be estimated by linear extrapo-lation of the data obtained between 2.1 and 3.5% down to the 1.37% value corresponding to the MSU tests. This yields an estimated peak fuel temperature of 230*C (in 8.5 wt % fuel). This is consistent with the MSTR ' (Note that the MSTR fuel contains 12 wt % U as compared to 8.5% in data. the GA tests. The higher fuel content would be expected to result in higher power density and a correspondingly higher temperature. This increase might be expected to be approximately 12-8.5/8.5 = 41% to project a 12 wt % fuel temperature in the GA tests of (230-30)(1.41) + 30 = 322*C.) The same GA report (6216) gives the results of theoretical calcula- i tions of peak and integrated power as well as fuel temperature use due to the reactivity insertion. The predicted temperatures compare closely with the observed values for large reactivity insertions. Similar calculations C-12 Rev. 1 6/84
demonstrated that the peak temperature in the fuel occurs not at the midplane between the centerline and cladding where the thermocouple is _ located. The peak temperature is approximately 21% higher than the midplane temperature which would extrapolate the measured MSTR fuel temperature to (280-30)(1.21) i 30 = 332*C. The maximum excess reactivity of the MSTR is 2.25% Ak/k; and, thus, it - is theoretically possible to insert this amount of reactivity into the core. Again, based on GA 6216 such an insertion as a step increase would result in a bulk fuel temperature of 450*C. Again, correcting for the peak . to bulk calculation and 12 vs 8.5% fuel as above results in a peak tempera- - ture of 716*C, This temperature exceeds to the phase transition temper-ature of low hydrogen (H/Zrsl.5) fuol (GA7882) but the MSTR fuel with H/Zrsl.7 shows no such phase transition; and, thus, temperat'ures well above 1000*C are permissible. Thus, therapidinsertionofthefull2.25%ok[k' , reactivity into the MSTR is not expected to result in a thermal degradation of the fuel. High fuel temperatures might be expected to result in increased gas pressures'within the fuel due to expansion of the gas between the fuel meat and the cladding as well as the release of fission product gases. ' Similarly, the UZr/H 1,7 will exert a partial pressure of hydrogen which is a function of fuel temperature. _ Tests reported in GA6216 indicated that the maximum pressure generated in the fuel element was only 7 psig with a reactivity insertion of $4.20 (2.95% Ak/k). It is reasonable to assume, then, that the peak pressure in the MSTR reactor with 2.25% insertion will be less than this (note that at
$4.20 insertion, the peak fuel temperature according to this same report would be 610*C (bulk)-30 x 1.21 (peak / bulk) + 30 = 732*C which is consis-tent with the anticipated MSTR peak of 716*C). A peak pressure of 7 psig would result in a stress of about 1500 psi in the. fuel cladding. Report GA6216 gives the tensile strength of 304SS at 650*C to be 44,500 psi. Thus, i
the pressure generated by a 2.25% ak/k pulse will not even approach the bursting pressure of the cladding. - On the basis of this analysis, it is concluded that the rapid inser- ' tion of the full excess reactivity into the MSTR would not result in damage to the fuel. C-13 Rev. 1 6/84
e .. e
- 4. Mechanical Rearrangement of Fuel When it is necessary to remove irradiated fuel from the MSTR, the following procedure is typically followed. A 400 lb lead transfer cask (such as is used with the BMI-l shipping cask) is lowered into the reactor pool by means of a chain falls and A-frame superstructure. The cask is capable of holding three standard Triga fuel elements which are remotely loaded into the cask by a fuel handling tool. The cask is then removed from the pool and the lead shielding protects personnel from the radiation .
emitted by the fuel. During the cask handling process it is possible that the transfer cask _
~
could be dropped into the pool. Such an accident might impact upon the _
~
reactor and the reflector. It is proposed to analyze the consequences.of .._ such an incident. Several accident scenarios are possible:
- 1. Deflection of the control rod extensions with the resultant control
- rod withdrawal. Since the cask will impact in a downward -
direction, the principle force exerted will tend to drive the control rods into the core (a " safe" configuration). Even if a horizontal force is exerted on the extension rods, the removal of sufficient control rod wortE to enable the reactor to go critical is unlikely in light of the shutdown margin inherent in the MSTR.
- 2. Crushing of fuel. In case of impact of the cask onto the fuel, I
r deflection or crushing of the fuel is the likely result. The fuel I cladding of several elements would probably be damaged and the rare ! gas / halogen fission products in the gas gap between the fuel an the cladding would escape. Since the only situation involving the fuel transfer cask would involve a flooded pool, the fission product release described above (for fuel failure in air) would be reduced I l -by the dissclution of halogens in the pool water. As indicated in the air rupture analysis, the largest radiation is due to the Iodine release. For the present analysis, more than one element might be damaged resulting in the releases of greater amounts of rare geses and Iodine. However, the presence of the pool water would reduce the amount of Iodine released to the room and, thus, compensate for the increased number of elements involved. It is, C-14 Revision 1 6/84 , l
e o. 6 thus, estimated that the radiation exposure for this accident postulation would approximate that of the one analyzed previously (Fuel Element Failure in Air).
- 3. Impact on Rafte; or Ion Chambers. The reflector of the MSTR will serve as an iepact shield for the reactor core. It will, therefore, reduce the consequences of a falling cask over that described in #2 above. Since the reflector contains little ',
radioactivity and no fuel, damage to it will not result in a significant radioactivity release. It is, therefore, concluded that the worst case resulting from a cask dropping into the reactor pool would result in no greater consequences than . the fuel element failure in air previously analyzed.
~ ~ -- [
C-15 Revision 1 6/84.. t - _. . - - . . . _ . . , ._}}