Annual Rept for 1979
ML19290E860
Person / Time
Site: 05000294
Issue date: 03/05/1980
From: Carrick J
MICHIGAN STATE UNIV., EAST LANSING, MI
To:
References
NUDOCS 8003170180
Download: ML19290E860 (2)


Text

.

s MICillG AN STATE UNIVERSITY Coll FGF OF I NGINF t RING ' DlVislON OF FNGINil HING Hl WARCH EAST L AN5lNG a MICHIGAN 4W24 March 5, 1980 Director of Inspection and Enforcement U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 Docket No.: 50-294 Michigan State University Triga Reactor License R-ll4 Annual Report

Dear Sir:

Pursuant to 10CFR50-59 the following report is submitted:

1.

During the operating period of January 1, to December 31, 1979 the following experiments were performed:

a.

55 central thimble irradiations b.

1547 rotary specimen rack irradiations c.

total operation of 1.65 megawatt-days 41 2.

Records indicate Ar releases totalling 2224 pCi or an 3

average release rate of 1.88 x 10 pCi/ml.

3.

Tank bottom deflection has been monitored regularly with no apparent change or trends.

4.

There were seven unscheduled scrams during the reporting period:

DATE SCRAM CAUSE 5/22/79 PERIOD Operator error--log channel over compensated.

8/16/79 PERIOD Transient in log recorder circuit.

10/17/79 RECORDER Transient in linear recorder circuit.

11/27/79 RECORDER Noise transient in linear recorder circuit.

11/27/79 RECORDER Noise transient in linear recorder circuit.

11/28/79 RECORDER Noise transient in linear recorder circuit.

Noise apparently caused by loose connection in amplifier circuit.

12/27/79 RECORDER Noise transient in linear recorder circuit.

Noise apparently caused by improper grounding of recorder chassis.

6003170\\80

o 9

5.

The renewal process for License R-ll4 continued with the sub-mission of an Environmental Impact Appraisal and revised Physical Security Plan.

6.

A computer based gamma spectroscopy system was obtained for activation experiments and environmental monitoring.

7.

There are currently three students being trained as operators.

Sincerely, h

James Carrick Reactor Supervisor