ML20076K782

From kanterella
Jump to navigation Jump to search

Commits to Addl Volumetric Testing of Welds to Determine Extent of Intergranular Stress Corrosion Cracking in Recirculation Sys & RHR Sys Piping,Per 830707 Meeting W/Nrc. Proposed Insp Plan Will Be Submitted by 830805
ML20076K782
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 07/08/1983
From: Head G
GEORGIA POWER CO.
To: Stolz J
Office of Nuclear Reactor Regulation
References
NED-83-384, TAC-51407, NUDOCS 8307180101
Download: ML20076K782 (1)


Text

Gee a a Pcwer Cypany 333 heent ' Ce Atama Gmrct 173AS iBmec 404 026J893 W img Adamss Pest Ctu Ccv 495 Arrta Gm pa 3030?

G.F. Head s-a we - m- NED-83-384 runarnce July 8, 1983 Director of Nuclear Reactor Regulation Attention: Mr. John F. Stolz, Chief Operating Reactors Branch No. 4 Division. of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 NRC DOCKET 50-366 OPERATING LICENSE NPF-5 EDWIN I. HATCH NUCLEAR PLANT UNIT 2 ComITMENT FOR INTERIM TESTING OF PLANT PIPING FOR IGSCC Gentlemen:

On July ~ 7, 1983, Georgia Power Company (GPC) management met with U. S.

MJclear Regulatory Commission staff management concerning operation of Plant Hatch Unit 2 with existing conditions of Intergranular Stress Corrosion Cracking (IGSCC) in recirculation system and residual heat removal (RHR) systeJn piping. Pursuant to those conversations, GPC hereby makes the following commitments:

GPC will conduct additional volumetric testing of appropriate welds to determine to what extent, if any, IGSCC cracking has progressed in both the repaired and unrepaired RFR and recirculation piping. A detailed proposed inspection plan will be submitted for NRC review by August 5, 1983. This plan shall include provisions for identifying crack depth and crack propagation rate to support continued plant operation.

If you have questions regarding these commitments, please contact this office.

Very truly yours,

%.t.tk G. F. Head

)

WEB /mb xc: J. T. Beckham, Jr.

I H. C. Nix, Jr.

L. T. Gucwa }

J. P. O'Reilly (NRC- Region II)

Senior Resident Inspector

,h L

8307180101 830708 PDR ADOCK 05000366 P PDR

_______ _____ _ _ _ _ _ - _ - _ - _ _ _ _ _ _ _ _ - _ _ _ - - _ _ _ _ - . _ - _ _ _ . _ _ _ _ _ _ _-- - _ _ _ - _ _ _ _ _ _