ML20069K070

From kanterella
Jump to navigation Jump to search
Corrected Monthly Operating Rept for June 1982
ML20069K070
Person / Time
Site: Brunswick 
Issue date: 04/11/1983
From: Harrison F
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML20069K012 List:
References
NUDOCS 8304260193
Download: ML20069K070 (1)


Text

o OPERATING DATA REPORT DOCKET NO. 050-0324 DATE 04/11/83 COMPLETED BY FRANCES HARRISON TELEPHONE (919)457-9521 OPERATING STATUS 1.

UNIT NAME: BRUNSWICK UNIT 2 i NOTES I

2.

REPORTING PERIOD: JUNE 82 I

i 3.

LICENSED THERMAL POWER (MWT): 2436 I

i 4.

NAMEPLATE RATING (GROSS MWE): 867.0 I

I 5.

DESIGN ELECTRICAL RATING (NET MWE): 821.0 l

I 6.

MAX DEPENDABLE CAPACITY (GROSS MWE): 815.0 l I

7.

MAX DEPENDABLE CAPACITY (NET MWE): 790.0 8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:

9.

POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE):

10. REASONS FOR RESTRICTION IF ANY:

THIS YR TO CUMUL MONTH DATE ATIVE

11. HOURS IN REPORTING PERIOD 720.00 4343.00 58368.00
12. NUMBER OF HOURS REACTOR CRITICAL

.00 2465.22 37632.12

13. REACTOR RESERVE SHUTDOWN HRS

.00

.00

.00

14. HOURS GENERATOR ON LINE

.00 2384.58 35153.88

15. UNIT RESERVE SHUTDOWN HOURS

.00

.00

.00

16. GROSS THERMAL ENERGY GEN. (HWH)

.00 4467965.05 64465505.02

17. GROSS ELEC. ENERGY GEN. (MWH)

.00 1415289.00 21409226.00

18. NET ELEC. ENERGY GENERATED (MWH)

-4609.00 1351908.00 20541310.00

19. UNIT SERVICE FACTOR

.00 54.91 60.23

20. UNIT AVAILABILITY FACTOR

.00 54.91 60.23

21. UNIT CAP. FACTOR (USING MDC NET)

.81 39.40 44.55

22. UNIT CAP. FACTOR (USING DER NET)

.78 37.92 42.87

23. UNIT FORCED OUTAGE RATE

.00 12.10 16.70

24. SHUTDOWNS SCHED. OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP:
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 8304260193 830413 DRADOCK05000f 1.16 - 9