SEMI-ANNUAL EFFLUENT RELEASE REPORT NO. 19 July 1, 1993 THROUGH December 31, 1993 PECO ENERGY LIMERICK GENERATING STATION UNITS NO. 1 AND 2 DOCKET NO. 50-352 (Unit 1)

DOCKET NO. 50-353 (Unit 2)

Submitted to The United States Nuclear Regulatory Commission Pursuant to Facility Operating License NPF-39 (Unit 1) and NPF-85 (Unit 2)

A

)U t'%

R.W.

Boyce, Plant Man (tger 9403000167 940223 PDR ADOCK 05000352 R

PDR

1 TABLE OF CONTENTS 1

I.

Introduction 1

II.

Tables A.

Summary of Radioactive Gaseous Effluents B.

Summary of Radioactive Liquid Effluents C.

Solid Waste Disposition Report D.

Offsite Radiation Dose Assessment E.

Radiation Dose to Members of the Public Due to Their Activities Inside Site Boundary III. Attachments A.

Supplemental Information - Assumptions Used in Report i

Generation B.

Radiation Monitors Out-of-Service C.

Radiological Environmental Monitoring Program sampling location change D.

Revision to Previous Submittals i

l

.,....-.a

. - ~

4 I.

INTRODUCTION This submittal complies with the format described in Regulatory Guide 1.21, " Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water Cooled Nuclear Power Plants", Revision 1, June, 1974.

The following information is included as Tables to this report:

A summary of the gaseous and liquid effluent releases for the report period.

Where "0.00E+00" is used, it denotes the less than detectable level for the given isotope.

Composite particulate air samples, counted for beta emitters (eg. Sr-89, Sr-90), are submitted to an offsite vendor laboratory for analysis.

Since data for the fourth quarter particulate air samples were not available at the time this report was prepared, it will be necessary to submit an addendum in the future if fourth quarter particulate air samples results are reported

>LLD.

Since Limerick Technical Specification limits for liquid and gaseous effluent releases are stated in terms of quarterly and annual offsite doses, " percent technical specification limit" is given as 0.00E+00.

A summary of solid waste dispositioned during the report period, to include: total activity shipped by waste type and an estimate of the error in the reported totals; the estimated composition of each type of waste by isotope; the number of shipments, mode of transportation, destination, type of container, total container volume, and solidification agent.

There were no changes to the Offsite Dose Calculation Manual (ODCM) or Radioactive Waste Treatment Systems during the report period.

i

i

+

l t

II.

TABLES i

A.

SUMMARY

OF RADIOACTIVE GASEOUS EFFLUENTS I

July 1, 1993 to December 31, 1993 i

5

)

I i

f

?

r i

t i

i

'E i

?

,x

.s n - -

+-.a r

.e.

a

- UNIT: U2

n..ea....

.u. A.v,~i A.S./.9. / " 4 S. D,

  • S r n %T. r..*

..s

.s 1

EFFLUENT AND WASTE PIEPOSAL REFORT 1

GA5 ECUS EFFLUENTS -- SUP.MATION OF ALL RELEASES UNITS : QUARTER : GUARTER:

EST. TOTAL:

3 4

ERROR, %

A. FI2SION AND ACTIVATION GASES

____...__._...______...L______.__...___

s.

1. TOTAL RELEASE CI

-: 0.571Ef02 : 0.401Ef02 0.453Ef02 :

2. AVERASE RELEASE
UCI/SEC: 0.719Ef01 : 0.505Ef01 :

RATE FOR PERIOD

3. PERCENT OF TECHNICAL
0.000Ef00 1 0.000Ef00 :

~

SPECIFICAT!DN LIMIT :

1.

B. 10 DINES 1_1. TOTAL IDDINE-131

.CI
0.330E-03 0.1072-0.3 0.453Ef02
'2.

AVERAGE RELEASE

~ :UCI/EEC: 0.415E-04 : 0.135E-04.:

RATE FOR PERIOD 0.000et.00 0.00n.e.f00..

w ne T. r e H h.. r Ai..,

e..r.e. r uT.

.-n SPECIFICATION LIMIT :

C. '* ART ~~ULATES 1

. PARTICULATES L'ITH CI

0.112E-01 : 0.591E-02 0.453Ef02 :

HALF-LIVES >B DAYS :

2. AVERAGE RELEASE
UCI/SEC: 0.141E-02 0.743E-03 :

n..6..r r0nn pr.n40n

3. PERCENT.0F TECHNICAlf 0.000Ef00 0.000Ef00 :

SPECIFICATION LIMIT

4. GROSS ALPHA CI
0.138Ef01 0.773Ef00 :

~

RADI0 ACTIVITY D. TRITIUM

1. TOTAL RELEASE CI
0.000Ef00 : 0.239Ef00 0.453Ef02 :
2. AVERAGE RELEASE UCI/SEC: 0.000Ef00 : 0 106E400 :

RATE FOR PERIOD -

l

't

!~

3. PERCENT OF TECHNICAL:

% ~

0.000Ef00 : 0.000Ef00 :

SPECIFICATION LIM.IT C

.r ~.. -

. ~ -. -

ENTER C C ] TO ERASE SCREEN AND CONT.INUE :.

,'s g

-,.q-.

~c' t

PAGE 'l 0F 12 SITE: LIMERICK UNIT: U1 USER: MART IATE: 02/22/94 09:26 EFFLUENT'AND' W'ASTE DIS OSAL REPORT GASEQUS EFFLUENTS FOR RELEASE POINT 1 NORTH STACK CONTINU0US MODE BATCH NODE NUCLIDES : UNITS '; GUARTER :

GUAhTER

QUARTER QUARTER
RELEASED :

... 3.

4 3

4

1. FISSION GASES AR41 CI
0.000E+00 0.000Ef00 0.000E+00 1 0.000E+00 ':

KRB3M CI

0.000Ef00 0.000Ef00~; 0.000Ef00 1 0.000E+00 :
KR85M CI
0.000Ef00 1 0.000E+00 0.000Ef00 1 0.000E+00 :

KR85.

CI

0.000Ef00 : 0.00'0Ef00 : 0.000E+00'; 0.000E+00
KR87 CI
0 000Ef00

~0.000E+00 0.000Ef00 : 0.000E+00 :

KRES CI

0.000E+00 : 0.000Ef00 0.000Ef0O' 0.000Ef00 :

KRB9-

. CI. : 0.000E+00

-0.000E+00 l- 0.000Ef 00 : 0.000E+00 :-

KR90 CI 1,0.000,Ef0~0 : 0.000E+00 1 0.000Ef00 0.000Ef00 :

XE131M

' CI
. 0 -000E+0 0.000Ef00 : _0.000Ef00 : 0.000E+00 :

.__....................___.._.0:

XE133M CI

~ 0.000EED0 : 0.000Ef00 0.000Ef00 ! 0.000Ef00.

XE133 CI 0.000Ef00 1 0.000E+00 0.000E+00 1 0.000Ef00 XE135M CI l'0.000Ef00 : '0.000E400 : 0.000Ef00 : 0.000Ef00 :

XE135 CI

!~ 0.229E+02 : 0.22BE+02 : 0.000Ef00 : 0.000E+00 :

XE137 CI 0 000Ef00 1 0.000E+00 ! 0.000Ef00 1 0.000E+00 :

XE138-CI

0.000Ef00 1 0.000Ef00 : 0.000Ef00 : Og000Ef00 1 TOTAL FOR !

PERIOD.

CI

0.229E+02 1 0.220Ef02.1 0.000E+00 1 0.000E+00 :

l' (ABOV.E) w ENTER I C 3 TO ERASE-SCREEN. AND CONTINUE :

C l

I I

i a

  • \\

......m N

y y

n o

y

,_.en+,

=

E FACE 2 0F 12 SITE: LIMERICK UNIT! U1 USER: MART DATE! 02/22/94 09326 EFFLUENT AND UASTE DloFOSAL REFORT DASEOUS EFFLUENTS FOR RELEASE FOINT!

1 NORTH STACK CONTINUOUS MODE BATCH H0DE f

NUCLIDES : UNITS <!

OUART'ER QUARTER 1 QUARTER ! 00ARTER' !

RELEASED :

3 4

3 4

.........__................_..._........__...__.................. ___...~

2. 10 DINES 1131
CI
0.327E-03 ! 0.107E-03 : 0.000Ef00 : 0 000Ef00 :

1133

CI
0.960E-02 i 0.413E-02 : 0.000Ef00 1 0.000Ef00 :

TOTAL f0R !

PERIOD CI

! 0.993E-02 1 0.424E-02 : 0.000Ef00 0.000Ef00 :

(ABOVE) j'

3. PARTICULATES
C14 1 'CI

! 0.000Ef00 0.000Ef00 0.000Ef00 1 0.000Et00.8 CR51

CI
0 000Ef00 ! 0.000Ef00 1 0.000Ef00 1 0.000Ef00 :

1 MN54

. CI

! 0.000Ef00 ! 0.000Ef00 1 0.000Ef00 1 0.000Ef00 :

.}:

FE59

't CI 1;0 000Ef00 1 0.000Ef00 1 0.000Ef00 1 0.000Ef00 :

l C058

CI

! 0.000Ef00 1 0.000Ef00 ! 0.000Ef,00 1 0.000Ef00 :

~

I C060

CI i 0 000Ef00 1 0.000Ef00 t 0.000Ef00*! 0.000Ef00 l-

%0PCON, 22-FEB-1994 09:27809.44, message from user SYSTEM 02/22/94 09 27805 OMUPDT! COMMUNICATIONS IS FAULTY ON RM-11 NUMBER 1 ZN65 CI

'l 0.000Ef00 ! 0.000E400 1 0.000Ef00 1 0.000Ef00 t

. !1 SRB 9 i

CI

! 0.109E-01 0.553E'02 i 0.000Ef00 1 0.000Ef00 L 4

SR90 CI i 0.000Ef00 1 0.314E-03 1 0.000Ef00 : 0.000Ef00 i

ZR95
C1

't 0 000Ef 00 1 0.000Et00 1 0.000Ef 00 1 0.000Ef 00 !-

SB124 CI 0.000Ef00 ! 0.000Ef00 1 0.000E400 1 0.000Ef00 i i

^

CS134 CI i 0.000Ef00.: 0.000Ef00 1 0.000Ef00 1 0.000Ef00 t t

CS136 CI

0.000Ef00 1 0.000Ef00 1 0.000Ef00 1 0.000Ef00 1 t

CS137 CI

! 0.000Ef00 1 0.000Ef00 1 0.000Ef00 ! 0.000E400 :

res r F 7 te reier 'croren m rnnvonir 't c '

~

~

1 y.-,

~. -,.

, - ~

m,.. -,

....o.,

w

PAGE 3 '0F 12 SITE:. LIMERICK j

UNIT: U1.

USER: MART e

f PATE: 02/22/94 09:27 l

+

EFFLUENT AND WASTE DISPOSAL REPOR1 GASEOUS EFFLUENTS FOR RELEASE POINT: 1 NORTH STACK I

CONTINU0US HDDE BATCH MODE

NUCLIDES

! UNITS'l GUARTER :

OUARTER ! GUARTE! : OUARTER !

4

RELEASED

... 3_ _ _ : _

3

.4--

2. PARTICULATES (CONTD)-
BA140 CI
0.000E+00 : 0.000Ef00 ! 0.000Ef00 0.000E+00 :

l CE141 CI

0.000Ef00 : 0.000E+00 0.000Ef00 0.000E+00 :
CE144 CI
0.000Ef00 i 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

s TOTAL FOR :

~

PERIOD CI
0.109E-01 : 0.594E-02 : 0.000Ef00 0.000Ef00 :

(ABOVE)-

~

ENTER C C'J TO. ERASE SCREEN AND CONTINUE 1 C

~

L-

~

4 e

e 9

4

+

e 5

e S

e i

d

..w.

.-*me,. e emeses.

w e.e e

e a

.,e

.u.

PAGE 4 0F 12 SITE: LIMERICK UNIT: U1 i

USER: MART PATE: 02/22/94 69:27 l

EFFLUENTANDWASTEDISPOSALREFORf.

..--___---__-_-_7 I

4 GASEOUS EFFLUCNTS FOR RELEASE PDI,NT: 2 UNIT 1 - SOUTH STACK CONTINUOUS MDDE BATCH MODE NUCLIDES

UNITS :

OUARTER : QUARTER : GUARTER : QUARTER

RELEASED :

3 4

3 4

1. FISSION 0ASES
AR41
CI
0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
KR83M
CI
0.000Ef00 ; 0.000Ef00 0.000Ef00 : 0.000Ef00 :

KRB5M

CI
0.000Ef00 0.000Ef00 : 0.000EYOO : 0.000Ef00 :
KRB5
CI
0.000Ef00

0.0 00Ef00'

0.000Ef00 : 0.000Ef00 1 KRB7

? CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 KRSB
CI
0.000Ef00 1 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
KRB9

-: CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
KR90
CI
0.000Ef00 : 0.000Ef00 1 0.000Ef00 : 0.000Ef00 :~
XE131M

! CI

0.000Ef00 0.000E400.: 0.000Ef00 1 0.000Ef00 :

[c

'XE133M
CI. : 0.000Ef00 _f 0.000Ef00 0.000Ef00 0.000Ef00 :
XE133 CI

.0.000Ef00 0.000Ef00 : 0.000Ef00 1 0.000EiOO :

XE135M CI

. 0.000Ef00 : 0.000Ef00 : 0 000Ef00 : 0.000Ef00 :

XE135

CI

' O.000Ef00 : 0.000Ef00 : 0.000Ef00 1 0.000Ef00 :

- XE137
CI i'O.000Ef00 1 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

XE138 -

-: CI

[0000Ef00!0.000Ef00: 0.000Ef00 0.000Ef00 :
TOTAL FOR :

%DPCOM, 22-FEP-1994 09:28:09.42 _ message from user SYSTEM.

02/22/94 09:28:05.0MUPDT! COMMUNICATIONS IS F.AULTY ON RM-11 NUMBER 1

PERIOD
CI 0 000Ef00 0.000Ef00 0.000Ef00 : 0.000Ef00 :

(ABOVE)

ENTER C C ] TO ERASE SCREEN AND CONTINUE : C

,..,.p r... -

_ - -. ~..

_______.___________________.__.m

PAGE 5 0F 12 SITE: LIHERICK UN ET: U2 USER: MART I

Ente: 02/22/94 09:28 I:

EF, FLUENT AND WASTE DISPOSAL REPORT GhSEOUSEFFLUENTSFORRELEASEPOINT:

2 UNIT 1 - SOUTH STACK CONTINUOUS HODE BATCH MODE

NUCLIDES : UNITS.: GUARTER :

QUARTER : GUARTER : QUARTER

RELEASED 3

4 3

4

~

2. IODINEE 1131
CI
0.000Ef00 : 0.000Ef00 1 0.000E400 : 0.000Ef00 :

I133 CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

TOTAL FOR :

l

PERIOD
CI
0.~000Ef00 : 0.000Ef00 : 0.000E+00 : 0.000Ef00 ;

~

(APOVE)

I. FARTICULATES

C14' CI
-0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000E+00 :

CR51

CI
04232E-03 0.650E,04 : 0.000Ef00-: 0._000Ef00 :

~

~

HN54 CI
0.000E+00 0.000E400 : 0.000E4005: 0.000E+00 :
FE59 CI
0.000E+00 : 0.000Ef00 0.000Ef06 : 0.000Ef00.:

..________r____....______

C058 CI

0.000Ef00 : 0.000Ef00-: 0.000E+ 0d.': 0.000E+00

~ ~

C060 CI

0.000Ef00 l 0.000Ef00 1 0.000Ef00 :

_'____._-_-___.______'0.000Ef00

ZN65 CI 0 000Ef00 0.000Ef00 : 0.000Ef00 1 0.000E+00 !

SR89

CI
0.000EiOO : 0.000E+00 0.000EiOO : 0.000E400 :

SR90

~:

CI

0.000Ef00 : 0.000E400 : 0.000Ef00', 0.000Ef00 3 ZR95 CI
0.000Ef00 : 0.000Ef 00 1 0.000E400 A 0.000E+00 :
SBI24 CI
0.000E+00 1.0.000Ef00 0.000E+00 : 0.000Ef00 :.

____________________a_____________.__...;____

! CS134 l' CI

0.000Ef00 0.000E+00 : _0.000Ef00 ! 0.000E+00 :

CS136 CI

0.000Ef00 : 0.000Ef00 0.'000Ef00 1 0.000E+00
CS137
CI 1,0.000E+00 ! 0.000Ef00 0.000Ef00 : 0.000Ef00 :

ENTER I C J TO ERASE SCREEN AND CONTINUE :

C

{

i

t t

(

PADE 6'0F 12 SITE: LIMERICK UNIT: U1 USER: MART DATE: ~02/22/94 09:28 EFFLUENT AND UASTE DISP 0' SAL REPORT GASEOUS EFFLUENTS FOR RELEASE POINT: 2 UNIT 1 - SCUTH STACK

- CONTINUGUS MODE BATCH HDDE NUCLIDES : UNITS : QUARTER :

GUARTER : 00ARTER QUARTER

RELEASED

3

~4 3

4

3. PARTICULATES (CONTL) l BAI40 CI
0.000E+00 : 0.000Ef00 : 0.000E400 : 0.000Ef00 :

CE141 CI

0.000E400 : 0.000E+00 0.000Ef00 : 0.000E+00 :
CE144 CI..- ! 0.000Ef00'_: 0.000E 00 : 0.000Ef00 0.000Ef00.:

TOTAL FOR :

PERIOD CI

0.232E--03 ': 0.650E-04 : 0.000E+00 1 0.000Ef00 1 (ABOVE)

ENTER C'C 3 TO-ERASE SCREEN END CONTINUE :

C-e B

e S

4 4

9 h

t

. ~

m a

f

)

i

^

D e

e O

e eeea ma enewmeem emmeae-e-

.m

  • N O

-q

.f PAGE 7 0F 12 i

l SITE: LIMERICK UNIT: U1 I

f USER: MART l

DATE: 02/22/94 09:29 EFFLUENT AND UASTE DISFOSAL REPORT

~.

.I CASEOUS EFFLUENTS FOR RELEASE POINT:

3 UNIT 2 - SOUTH STACK l

CONTINUGUS.MODr 5ATCH MODE 20PCDM, 22-FEB-1994 09:29:09.43, messase from user SYSTEM 02/22/94 09:29:05 OMUPDT: COMMUNICATIONS IS FAULTY ON RM-11 NUMEER 1

.' NUCLIDES -: -UNITS :

QUARTER - 1 00ARTER - -+ -GU ARTER - : GUARTE'R--F -

RELEASED !

3 4

4

1. FISSION GAEES
AR41 CI
0.000Ef00 0.000Ef00 0.000Ef00 1 0.000Ef00 :

KRS3M

CI. : 0.000Ef00 : 0.000E.400 : 0.000E+00 : 0.000Ef00 :
KRS5M CI
0.000Ef00 0.000Ef00 0.000Ef00 : 0.000Ef00 :
KR35 CI
0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

KRB7 CI

0.000Ef00 1 0.000Ef00_ 0.000Ef00 0 000Ef00 :
KRBB CI'
0.000Ef00 : 0 000Ef00' 0.000Ef00 :.0iO00Ef00 :
KRB9-
CI
0.000Ef00 0.000Ef00 0.000Ef00 0.000Ef00 :

~

KR90

.hI

.: 0.00'OEf00 : 0.0.00Ef00 0.000Ef00 : 0.000Ef00 :

XE131M CI
0.000Ef00 0.000Ef00 0.000Ef00 ! 0.000Ef00 :
XE133M CI
0.000Ef00 0.000Ef00 : 0.000Ef00 0.000Ef00
XE133 CI
0 138Ef01
  • 0.000Ef00 0.000Ef00 : 0.000Ef00 :
XE135M
~ CI
0 000Ef00 0.000Ef00 0.000Ef00 : 0.000Ef00 :
XE135 CI
0.329Ef02 : 0.173Ef02 : 0.000Ef00 1 0.000Ef00 *
XE137
CI
0.000Ef00 1 0.000Ef00 1 0.000Ef00 0.000Ef00 :
XE130

~; CI

0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.'00dEf00 :
TOTAL FOR :

1.

0.000Ef00 : 0.000Ef00 :

FERIOD

-: CI

0.343Ef02 : 0.173Ef02 :

(APOVE)

~!

ENTER C C 3 TO ERASE SCREEN AND CONTINUE :

C

. 4 _..

1 4

1 l

pg n..e g n..r

$9 SITE: LIMERICK

. UNII: U1 USER: MART i

DATE 02/22/94 09:29 g

EFFLUENT AND WASTE DISPOSAL REPORT l

GASEOUS EFFLUENTS FOR RELEASE POINT 3 UNIT 2 - SOUTHjSTACK CONTINUOUS MODE PATCH MODE NUCLIDES : UNITS : QUARTER : OUARTER : QUARTER :

QUARTER :

RELEASED :

3 4

3 4

2. 10DINEE I131 CI
0.331E-05 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

I!33 CI

0.16BE-03 0.000Ef00 : 0.000Ef00 0.000Ef00 ;

TOTAL FOR :

PERIOD - ! CI

0.171E-03 1 0.000E+00 0.000E+00 : 0.000E+00 :

(APOVE)

3. FARTICULATES

~

C14

CI
0.000E400.0.000Ef 00 :- 0.000Ef 00 ' 0.000E+00 :

CRS1

CI
0.000Ef00 1 0.000Ef00 : 0.000Ef00 0.000E+00 :

MN54

CI
0.000E+00 l 0.000Ef00 0.000Ef00 : 0.000Ef00 :
FE59 CI
0.000E+00 : 0.000E+00 1 0.000Ef0,0 : 0.000Ef00 :

C050 CI

0.000Ef00 : 0.000Ef00 0.000Ef00 0.000E+00 :

C060 CI'

0.000Ef00 0.000Ef00 : 0.000E+00 : 0.000E400 :

ZN65 CI

0.000E+00 ! 0.000Ef00 0.000Ef00 : 0.000E+00 :

SRB 9

CI
0.000E+00 1 0.000Ef00 : 0.000E+00 : 0.000E+00 :

SR90 CI

0.000E+00 : 0.000Ef00 1 0.000Ef00 1 0.000E+00 ;

ZR95 CI

0.000E+00 0.000Ef00 : 0.000E+00 : 0.000Ef00 :

SB124

- CI
0.000Ef00': 0.000Ef00 : 0.000Ef00 :~0.000Ef00 !

~

CS134 l CI

0.000E400 0.000Et00 : 0.000Ef00 : 0.000E+0h:

CS136.

1 CI

0.000Ef00 ; 0.000Ef00 : 0.000Ef00 : 0.000E400 :

CS137 CI

'! 0.000Ef00 : 0.000Ef00 : 0.000E400 0.000Ef00 :

ENTER E C 3 TO ERASE. SCREEN AND CONTINUE :

20PCOM, 22-FEB-1994:09:30:09.4Sr message from user SYSTEM

...,...,....,.w n u i,.,. e n u ui m w.m m.e

.e

e. n y

m,eu_..

i.,, u m _._

SITE: LIMERICK UNIT U1 USER: MART DATE: 02/22/94 09:30 EFFLUENT AND WASTEfDISPOSAL REPORT

__________.._____f.____..._-..--

i GASEOUS EFFLUENTS.'FOR RELEASE POINT:

3 UNIT 2 - SOUTH STACK

't CONTINU0US H0DE PATCH NODE NUCLIDES

UNITS :

QUARTER :

QUARTER :

QUARTER

. QUARTER
RELEASED 3

4 3

-4

.__.____________..___._-..:--~._______.___.....__.---__._-

3. PARTICULATES (CONTD)

BA140 CI

0.000E+00 : 0.000E+00 : 0.000E+00 : 0.000E+00 :

CE141 CI

0.000Ef00 : 0.000Ef00 0.000Ef00 0.000Ef00 :

CE144

CI
0.000Ef00 ! 0.000Ef00 0.000Ef00 : 0.000E+00 :

TOTAL FDR 1.

PERIOD CI

0.000E+00 : 0.000Et00 : 0.000Et00 : 0.000E+00 :

(ABOVE)

^

~

L.1'. A Ir 8

a

" f.) L. *

  • N"'L.

7 )I T. C O.. * *

  • t T.9 C O.k C _r e f'O..r
  • H A1.(1 e

b L L a s.

w

...s

. ~:

4

~

~

e D

,*h" 9

"J

. /_.

'a

.b

4 FACE 10 0F 12 SITE: LINERICK UNIT: U1 USER:-HART DATE:_02/22/94 09:30 EFFLUENT AND WASTE DISPOSAL REPORT GASECUS EFFLUENTS FOR RELEASE POINT: 4 HOT MAINTENANCE SHOP CONT'INUGUS HODE BATCH HDDE NUCLIDES

UNITS :

QUARTER OUARTER ~; QUARTER : QUARTER :

RELEASED 3

4 3

1 4

1. FISSION GASES
AR41
CI
0.000Ef00 : 0.000Ef00 0.000Ef00 : OiOOOEf00 :

~

KRB3M
~ CI
0.000Ef00 : 0.000Ef00-0.000Ef00 1 0.000Ef00 :
KRB5M CI

'O.000Ef00 1 0.000Ef00 : 0.000'Ef00 0.000Ef00 :

~

KRSS
CI 0.000Ef00 0.000Ef00 '! 0.000Ef00 : 0.000Ef00 :

j l

KR87
CI 0.000Ef00 : 0.-000Ef00 0.000Ef00 : 0.000Ef00 :

______a_____________..____..___....._____.. _......________.. ___..__

! KRBB

CI
0.000Ef00 0.000Ef00 : 0.000Ef00 0.000Ef00 J KR89
CI

! 0.000Ef00 : 0.000.E.f 00

\\

0.000Ef00 0.000Ef00 :

l.

KR90 CI
0.000Ef00 0.000Ef00 0.000Ef00 : 0.000Ef00 1

...._____...________________.__..____4...._____...__.____________..-

~

XE131M CI
0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000Ef00 :-

J XE133M

CI
0.000Ef00 1 0.000Ef00.: 0.000Ef00 0.000Ef00 :
XE133 CI
0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.000Ef00 :

XE135M CI

0.000Ef00 0.000Ef00 0.000Ef00 0.000Ef00 :
XE135
.CI
0.000Ef0010.000Ef0010.000Ef_00: 0.000Ef00 XE137
CI
0.000Ef00 : 0.000E+00 0.000Ef00 : 0.000Ef00 :.

1

XE138

.: CI

0.000Ef00 ! 0.0_00Ef00 0.000Ef00 1 0.000Ef00 :
TOTAL FOR :

~

PERIOD CI
0.000Ef00 1 0.000Ef00, 0.000Ef00 0.000Ef00 :

(ABOVE)

ENTER C C 3 TO ERASE SCREEN AND CONTINUE :

C

__s....

..6..

...u t.i.

,,i,

_..__.m.

i i..w

FAGE 11 0F 12 SITE: LIMERICK UNIT: UI USER: MART DATE: 02/22/94 09:31

)

EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS FOR RELEASE FOINT - 4 HOT MAINTENANCE SHOP CONTINUOUS MODE PATCH MODE

NUCLIDES
UNITS QUARTER
QUARTER.: QUARTER :

QUARTER

RELEASED 3

~4 3

4

~-________________ _....__._______,____

_J.__ _ _____......... _ -

%0PCOM, 22-FEB-1994 09:31:09.45, message from user SYSTEM 02/22/94-09:31:05 OMUPD.T: COMMUNICATIONS IS FAULTY'ON RM-11 NUMBER 1

2. IDDINES I131 CI
0.000E+00 0.000E+00 0.000E+00 : 0.000Ef00 I133 CI
0.000E+00 : 0.000E+00 : 0.000E+00 0.000Ef00

______.........._1 l TOTAL FOR :

~ :

~

PERIOD CI
0.000Ef00 : 0.000Ef00 : 0.000E+00 : 0.000Ef00 :

(APOVE) 1

3. PARTICULATES C14

~

_CI

0'.000Ef00 ; 0.000E+00 : 0.000Ef00 F 04000E+00 :

___'CR51 *_

CI 1,0,000Ef00 0.000E+00 0.000Ef00 0.000E+00 :

MN54 1-CI I 0.000Ef00 : 0.000E+00 : 0.000Ef00 1 0.000Ef00 :

FE59.,

CI

0.000Ef00 : 0.000E+00 : 0.000Ef00 1 0.000E+00 :
C058 CI
0.000Ef00 1 0.000Ef00 0 000E400 1 0 000E400 :

C060 CI

0.000E+00 0.000E+00 0.000E+00 : 0.000Ef00 :
ZN65

. CI 0.000E+00 : 0.000Ef00 0.000E+00 ! 0'.000E+00 :'

j SRB 9 -

CI L 0.000Ef 00 1 0.000Ef 00 0.000Ef00 : 0.000Ef00 :

SR90 CI
0.000E+00'! 0.000E+00 : 0.000Ef00 : 0.000E+00 :
ZR93 CI.
0.000E+00 : 0.000Ef00 ! 0.000Ef00

'0.000Ef00 :

\\

SP124 CI

0.000E+00 : 0.000Ef00 0.000E+00 : 0.000Ef00 :

CS134 CI

0.000E+00 : 0.000E+00 : 0.000E+00 0.000E+00 :

j

CS126 CI
0.000Ef00 1 0.000Ef00 : 0.000E+00 1 0.000Ef00 :
CS137 CI
0.000E+00 : 0.000E+00 : 0.000E+00 : 0.000E+00 :

1 ev-ro'r 6 l'Tn rioee trorry Ann ennTinor ;

c'

~

i

.~

PAGE 12 0F 12 SITE: LIMERICK UNIT: U1 f

USER: MART TATE: 02/22/9A 09:31 5

EFFLUENT AND WASTE DISPOSAL REPORT l

f GASEOUS EFFLUENTS FOR RELEASE FOINT: 4 HOT MAINTENANCE SHOP i

CONTINUGUS MODE BATCH MODE.

i

NUCLIDES : UNITS : GUARTER QUARTER QUARTER : QUARTER
RELEASED 3

4 3

4 I

i

~

3, PARTICULATES (C0NTD)

BA140 CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00
CE141 CI
0.000Ef00 : 0.000Ef00 ; 0.000Ef00 : 0.000Ef00 :

CE144 CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000Ef00 :

TOTAL FOR :

4 l

l

PERIOD
~ CI
0.000Ef00 : 0.000Ef00 : 0.000Ef00-: 0.000Ef00 :

(ABOVE)

ENTER E C 3'TO ERASE SCREEN AND CONTINUE :

C e

ID' 6e m

e m.-

e W

e 4

an e

ed8W'"#

4

.W

=

II.

TABLES

[.

l B.

SUMMARY

OF RADIOACTIVE LIQUID EFFLUENTS July 1, 1993 to December 31, 1993 i

j i

l

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _____________j

UNIT: UI '.

USER: MAR'T DATE: 102/22/94 09:31 r

EFFLUENT;AND WASTE DIEPOSAL REPORT I

2 LIQUID EFF'LUENTS -- SUMMATION OF ALL RELEASES 3

l j

UNITS : QUARTER
QUARTER EST. TOTAL:

3 4

ERROR, f.

A. FISSION AND ACTIVATION PRODUCTS l

l 1. TOTAL RELEASE (EXCL.: CI

0.30BE-01 : 0.644E-01 : 0.62BE+01 :

TRIT., GASES, ALPHA):

1

2. AVERAGE DILUTED UCI/ML : 0.223E-06 : 0.412E-06 :

CONC. DURING PERIOD :

+

3. PERCENT OF
0.000E+00 : 0.000E+00 :

APPLICABLE LIMIT S. TRITIUM

~

1. TOTAL RELEASE CI
0.397E+01 : 0.937E+01 : 0.62BEf01 :
2. AVERAGE DILUTED
UCI/ML l'0.2SBE-04 : 0.60.0E-04 :

CONC. DURING PERIOD :

%DPCOM, 22-FEB-1994 09:32:09.45, message frem user SYSTEM 02/22/94 09:32:05 OMUPDT: COMMUNICATIONS IS FAULTY ON RM-11 NUMBER 1

3. PERCENT OF
0.000Ef00 0.000E+00 :

APPLICABLE LIMIT,

-i- -

i l

I l

C. DISSOLVED AND. ENTRAINED GASES

1. TOTAL RELEASE
CI
0.201E-01 : 0.265E-01 : 0.I2BE+01:
2. AVERAGE DILUTED
UCI/ML : 0.145E-06 : 0.170E-06 :

CONC. DURING PERIOD :

3. PERCENT OF 0.727E-01 : 0.849E-01 :

APPLICABLE LIMIT

(

D. GROSS ALPHA RADI0 ACTIVITY

1. TOTAL RELEASE CI f 0.000Ef00 : 0.000E+00 : 0.62SEf01 :

E. VOLUME WASTE RELEASED-l LITERS': 0.152E+07 : 0.171E+07 : 0.000E+00 :

l' (PRIOR TO DILUTION) l 1

l F. VOLUME DILUTION WATER LITERS : 0.13BEf09 : 0.156E+09 : 0.000E+00 :

I USED DURING PERIOD

[

..-se.esame==4 e. m 4

.sm e e,

a e

==

PAGE 1 0F 5 SITE: LIMERICK UNIT: U1 USER: MART-DATE: 02/22/94 09:32 EFFLUENT AND WASTE DISPOSAL REPORT LIGUID EFFLUENTS FOR RELEASE POINT:

1 LIQUID RAD WASTE DISCHARGE TO SCHUYLKILL RIVER

. CON!TINUOUS MODE BATCH MODE

'~

~~

I hbCLIbEh i UkiiS i bUkkTbk i. bUkki[k'~I bb kTik'~i 0Ukkikk I

~~

~~ ~~

~~ '

~ "~

RELEASED ^ :

3 4

3 4

1

-_-_-_______.~.:-_._______.____.______________-.___.

H3
CI
0.000Ef00 : 0.000Ef00 : 0'.397Ef01.: 0.937Ef01 :

C14

CI
0.000E+00 : 0.000E+00 1 0.000Ef00 : 0.000E+00 :
EA24
CI
0.D00'E+00 1 0.000E+00 :~0.000Ef00 : 0.000Ef00 :

___....._______________________2._,__________

P32 CI

0.000E+00 0.000EiOO : 0.000E+00 : 0.000Ef00 :

CR51 CI

0.000Ef00 : 0'.000Ef00 : 0.192E-01 : 0.32EE-01 :
MN54
CI
0.000Ef00 : 0.000E+00 : 0.856E-04 0.518E-04 :

0.,60E+00 0.000E+00 : 0.000Ef00 -0.000Ef00 :

0 l

HN56

. : CI

___a__._____....__ __... ___..___. ______ _-__.__ _____.______________

FE55
. CI
0.000E+00 : 0.000Ef00 -0.207E-02 1 0.000E+00 :
IFES9
CI -:~d.000E,+00
  • 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

~[.000E+00 0.000Ef00 : 0.206E-03'! 0.479E-03 :

0 C058 CI C060

CI
0.000Ef00 : 0.000Ef00 0.'634E-03 0.124E-02 :.
NI63
CI

!.0.000Ef00 1 0.000Ef00 : 0.000Ef00 0.000Ef00 :

1 l

NI65
CI
0.000E+00 1 0.000Ef00 0.000Ef00 0.000Ef00 :.

)

j l

CU64 CI

0.000EfC.0 : 0.000Ef00 : 0.000E+00 1 0.000E+00 : -
ZN65
CI
0.000E+00 0.000Ef00 : 0.520E-02 ! 0.109E-01

____________ _________.____i ______________..___________;________.._

ZN69
CI
0.000Ef00 : 0.000Ef00 1 0.000Ef00 : 0 000Ef00 :

__..____________________________....____..________.._________________^ -

BRS3 CI
0.000Ef00 0.000Ef00 :'O.000E+00 : 0.000Ef00 :
BR84
CI
0.000E+00 : 0.000Ef00 1 0.000Ef00 0.000Ef00 :

BRB5 CI

0.000Ef00 0.000Ef00 : 0.000Ef00 0.000Ef00 :

a ENTER C.C J TD ERASE SCREEN AND CONTINUE _:

C

l-PAGE 2 0F-5 SITE: LIHERICK UNIT: U1 USER: MART PATE: 02/22/94 09:33 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS FOR RELEASE POINT:

1 LIQUID RAD WASTE DISCHARGE TO SCRU.YLKILL RIVER CONTINU0US MODE 5ATCH HDDE

NUCLIDES

' UNITS :

QUARTER

GUARTER : GUARTER
QUARTER RELEASED :

3 4

3 4

LIQUID EFFLUENTS (CONTD)

~

R386

CI
0.000E+00 1 0.000E+00 1 0.000Ef00 : 0.000Ef00 l

RB88 CI

0.000E+00 : 0.000E+00 0.000Ef00 : 0.000E+00 :

RS89 CI

0.000E+00 : 0.000Ef00 : 0.000Ef00 0.000Ef00 :

0.000E+00

.0.154E-01 i SR99

.~:

CI

0.000E+00 : D.000Ef00 :
,SR90
CI
0.000E+00 0.000Ef00 1 0.000Ef00 : 0.162E-03 :

..______________________________u._____.___________

SR91 CI

0.000Ef00 ; 0.000E+00 : 0.000E+00 : 0.000Ef00 :

.__________________________...________.u_....___________....________-

-SR92 i CI

0.000E+60 : 0.000Ef00.

0.000E+00 0.000Ef00 :.

Y90
CI
0.000Ef00 : 0.000Ef00 1 0.000E+00 0.000Ef00 :
Y91H

.: CI 0.000E+00 : 0.000Ef00 : 0.481E-05 1 0.000Ef00 :

Y91

~

CI

0 000Ef00 0.000E'+00 0.000E+00 1.0.-000Ef00 :

Y92 CI

0 000Ef00 ! 0.000Ef00 0.000Ef00 1 0.000Ef00 :

Y93

CI f 0.000Ef00 0.000E+00 ! 0.000Ef00 ! 0.000Ef00 :
2R95 CI' 0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.000E+00 :

' : ZR97

CI
0.000E+00 : 0.00dE+0010.000E+00: 0.000E+00 :.
NB95
- CI
~ 0.000Ef00 : 0.000Ef00 ! 0.000E+00 0.000E+00 :
HD99 CI
0.000Ef00 0.000Ef00.

0.000Ef00 1 0.000Ef00 !

TC99H CI

0.000$f00 1 0.000Ef00 0.000E+00 0.000Ef00 :

.___.___.________._____.______....______a.______.____..____...____.___

TC101

CI
0.000Ef00 0.000E+00 : 0.000Ef00. 0.000E+00 :

ENTER I C 3 TO ERASE SCREEN AND CONTINUE :

C N

-_..a-.-

~_

~'

. :~ ~

-1 I

3 PAGE7 3 0F 5 EITE: LIMERICK UN!T U1 i

USER: MART i.

' DATE: 02/22/94 09:33 EFFLUENT AND WASTE DISPOSAL REPORT s

LIOUID EFFLUENTS FOR RELEASE POINT:

1 LIQUID RAD WASTE DISCHARGE TO ECHUYLKILL RIVER CONTINU0US MODE PATCH NODE NUCLIDES : UNITS : QUARTER

QUARTER
QUARTER :

00ARTER REL'ASED :

3

.4 '

3 4

E LIQUID EFFLUENTS (CONTD)

RU103 CI
0.000Ef00 0.000Ef00 : 0.000E+00 0.000E 00 :

RU105 CI

0.000EY00 0.000E+00 : 0.000Ef00 : 0.000E 00 RU106

- CI

0.000E+00 : OiOO0E+00 : 0.0.00E+00 : ~0.000E+00 AG110H CI
0.000E+00 : 0.000EY00 : 0.000Ef00 : 0.000Ef00 :
TE125M CI
0.000Ef00 : 6.000Ef00 : 0.000E+00 1 0.000Ef00 :

l TE127H CI

0.000E+00': 0.000Ef00 0.000Ef00 0.000E+00 :

........._____.a______...______________________..__..._.........

TE127 CI

0.000E+00 ': 0.000E+00 : 0.000Ef00 : 04000Ef00 :

TE129M CI

! 0.000Ef00 : 0.000Ef00 0.000Ef00 0.000E+00 :

TE129^

CI

0.000Ef00 0.000Ef00 0.000Ef00 0.000E+00 :

TE131M CI

0.000E+00 1 0 000Ef00 0.006E+00 0.000Ef00 :

TE131 CI

.0.000Ef00 0.000E+00 0.000E+00 1 0.000Ef00 :

TE132 CI

0.000E+00 0.000Ef00 ! 0.000Ef00 0.000E+00 :

1130 CI

0.000Ef00.1 0.000Ef00 : 0.000Ef00 1 0.000Ef00 :

1131 CI 0 000E+00 0.000Ef00 0.000Ef00 : 0.000Ef00 :

I132

^

CI

0.000Ef00 : 0.000Ef00 1 0.000Ef00 i 0.000Ef00 1133.

CI

. 0.000E+00, 0.000Ef00 1 0.000E+00 1 0.906E-05 :

I134 CI

0.'000E+00 0.000Ef00.1 0.000E+00 : 0.000Ef00 !

1135 CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000Ef00 :

C ENTER E C ] TO ERASE SCREEN AND CONTINUE : _

9 0

m

.rwr Fr m w w---m9 m

e--em 4.==--w r--

r-3-

+r--"

- - ~

-M" m-

- =^

4 v

+ov--se e--*

l l --

PAGE 4 -OF 5

r SITE: LIMERICK UNIT: U1 l

USER: HART I

4 DATE: 02/22/94 09:34 j

EFFLUENT, AND WASTE DISPOSAt.' REPORT

.t LIQUID EFFLUENTS FOR RELEASE POINT:

1 LIOUID RAD WASTE DISCHARGE TO SCHUYLKILL RIVER CONTINUQUS H0DE PATCN MODE.

_____________....... ~.__... _____.....______...__.__._.._________....

NUCLIDES

UNITS : QUARTER
QUARTER
OVARTER QUARTER :
RELEASED 3

4 3

4 LIQUID EFFLUENTS (CONTD)

CS134 CI
0.000Ef00 : 0.000Ef00 0.157E-04 : 0.817E-05 :

CS136 CI

0.000Ef00 : 0.000Ef00 0.000EY00 : 0.000EY00 :

CS137 CI~

0.000Ef00 : 0.000Ef00 0.865E-04 0.274E-04 :
CS138 CI
0.000Ef00 0.000Ef00 1.0.000Ef00 : 0.000Ef00 :

BA13?

CI

0.000Ef00 0.'000Ef00 : 0.000EYOO ! 0.000Ef00 :
  1. BA140 CI,

! 0.000Ef00 : 0.000Ef00 0.234E-O'4 ! 0.345E-O'4 :

^

~,'-

BA141

.CI

0.000Ef00 : 0.000Ef00 1 0.000Ef00 : 0.000Ef00 :

BA142 CI

0.000Ef00 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
LA140 CI
0.000Ef00 0.000Ef00 : 0.306E-02 0.277E-02 LA142 CI'

- 0.000Ef00 0.000Ef00 -! 0.000Ef00 0.000Ef00 :

C'E141 CI

0.000Ef00 : 0.000Ef00 : 0 151E-03 : 0.556E-03 :
CE143 CI
0.000Ef00 0.000Ef00 1 0.000Ef00 0.000Ef00 :

g

'CE144 CI
0.000Ef00 : 0.000E+00 : 0.245E-04 ! 0.000Ef00 !
PR143 CI
0.000Ef00 : 0.000Ef00 0.000Ef00 0.000Ef00 :

PR144 CI

!0.000Eih010.000Ef00: 0.000Ef00 6.000Ef00 :

.: ND147 CI

0.000Ef00 : 0.000Et00 : 0.000Ef00 1 0.000Ef00 :

AS76 CI

0.000Ef00 : 0.000Ef00

0.0 00Ef00'

0.000Ef00 :

W187' CI.
0.000Ef00 1 0.000Ef00 0.000Ef00 1 0.000Ef00 :

ENTER I C 3 TO ERASE SCREEN AND CONTINUE :

C

~

v 9

W

PAGE 5 0F 5 S!TE: LIMERICK UNIT: UI USER: MART DATE: 02/22/94 09:34 EFFLUENT AND WASTE DISPOSAL REPORT LIGUID EFFLUENTS FOR RELEASE POINT:

1 LIQUID RAD WASTE DISCHARGE TO SCHUYLKILL IVER-CONTINUGUS MODE BATCH MODE NUCLIDES

UNITS J GUARTER :

DUARTER

QUARTER : QUARTER R.EL.E A SED.

3 4

.3 4

--_____-._-_---_---....-________...._-____.-_.__.._-_-___==

LIQUID EFFLUENTS (CONTD)

NONE CI
0.000E+00 1 0.000EY00 0.000Ef00 0.000Ef00 :

o

TOTAL FOR f,
PERIOD
- C I,

! 0.000E+00 : 0.000E+00 0.400Ef01 0.944E+01 :

(ABOVE)

XE-133 CI
0.000Ef00 : 0.000Ef00 : 0.109E-01 :_0.135E-01 :

XE-135 CI

0.000Ef00 : D.000EiOO : 0.91SE-02 1 0.130E-01 :

_ 5FFLUENT RELEASE '

SUMMARY

OPTIONS

~

1 -- 7ERMINATE 2-JACCUMULATE DASEOUS RELE'ASES -

  • 3 -., ACCUMULATE LIQUID PELEASES 4 -- PRINT WASTE

SUMMARY

REPORT ENTER OPTION SELECTION C 1-4 3 :

~

ROUTINE RELEASE CALCULATION DPTIONS (LEVEL 2)

._7_________.._......___________________....__

1 -- RETURN TO TOP' LEVEL

~

2 -- CALCULATE X/0 OR DOSE 3 -- CALCULATE DOSES FOR GAEEOUS PATHWAYS

~

1 4 -- CALCULATE HYPDTHETICALLY HIGHEST EXPOSED RECEPTOR 5 -b CALCULATE DDSES FOR LIQUID PATHUAYS 6 -- PREPARE PATHWAYS DDSE

SUMMARY

FOR APPENDIX I REPORTS.

7 -- PREPARE GASEOUS AND LIQUID EFFLUENT

SUMMARY

REPORT S -- PREPARE SOLID WASTE REPORT ENTER OPTION SELECTION C 1-2 3 :

=

m' mwme m

p

II.

TABLES C.

SOLID WASTE DISPOSITION REPORT July 1, 1993 to December 31, 1993 I

i 1

I-1' l

3 A

PAGE 1.0F 4 A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT IRRADIATED FUEL) 7/1/93 - 12/31/93 1.

TYPE OF WASTE UNIT 6-MONTH EST. TOTAL PERIOD ERROR %

a. SPENT RESINS, FILTER SLUDGES, m(3) 1.19E+02 EVAPORTOR BOTTOMS, ETC.

Ci 3.40E+02 25%

b.

DRY COMPRESSIBLE WASTE, m(3) 1.86E+01

~ CONTAMINATED EQUIP., ETC.

Ci 2.22E+00 25%

c.

IRRADIATED COMPONENTS, CONTROL m(3) 0 RODS, ETC.

Ci 0

d.

OTHER (DESCRIBE)

NONE ACTIVITIY IS ESTIMATED 1

l t

l i

r 1

I l

I

PAGE 2 OF 4 ESTIMATE OF MAJOR NUCLIDE COMPOSITION (BY WASTE TYPE) 2.

CATEGORY B - DRY CATEGORY A -- SPENT RESINS,

COMPRESSIBLE-FILTER SLUDGES, EVAPORATOR WASTE, CONTAMINA-BOTTOMS, ETC.

TED EQUIPMENT, ETC WASTE WASTE WASTE CLASS B PERCENT CLASS A PERCENT CLASS A PERCENT ISOTOPE CURIES ABUNDANCE CURIES ABUNDANCE CURIES ABUNDANCE Cr-51 1.14E+02 38.37 1.80E+00 4.21 3.59E-01 16.15 Mn-54 8.27E+00 2.78 3.75E+00 8.79 2.07E-01 9.32 Fe-55 1.97E-02 0.01 2.27E+00 5.33 3.04E-01 13.72 Co-58 1.16E+01 3.90 8.20E-01 1.92 6.87E-02 3.09 Co-60 3.86E+01 12.98 5.48E+00 12.85 5.92E-01 26.65 Ni-63 2.17E-01 0.07 1.40E+00 3.28 4.76E-02 2.14 Zn-65 9.32E+01 31.38 9.40E+00 22.03 4.92E-01 22.15 H-3 1.43E-02 0.00 6.90E-02 0.16 2.34E-04 0.01 C-14 3.97E-03 0.00 2.43E-01 0.57 1.17E-03 0.05 Tc-99 9.39E-04 0.00 0.00E+00 0.00 0.00E+00 0.00 I-129 1.73E-04 0.00 0.00E+00 0.00 0.00E+00 0.00 Cs-134 7.S6E+00 2.54 6.12E+00 14.34 2.50E-02 1.13 Cs-137 1.09E+01 3.66 1.05E+01 24.61 8.80E-02 3.96 I-131 0.00E+00 0.00 6.07E-01 1.42 4.67E-03 0.21 Pu-238 1.17E-03 0.00 0.00E+00 0.00 0.00E+00 0.00 Pu-239/409.81E-04 0.00 4.96E-03 0.01 2.61E-05 0.00 Cm-242 9.26E-03 0.00 1.55E-05 0.00 0.00E+00 0.00 Sr-90 3.97E+00 1.34 5.33E-03 0.01 0.00E+00 0.00 Sr-89 8.74E+00 2.94 6.00E-03 0.01 0.00E+00 0.00 Pu-241 6.26E-02 0.02 0.00E+00 0.00 0.00E+00 0.00 cm-243/442.53E-04 0.00 0.00E+00 0.00 0.00E+00 0.00 BA-140 0.00E+00 0.00 9.53E-02 0.22'1.04E-03 0.05 LA-140 0.00E+00 0.00 9.53E-02 0.22 1.04E-03 0.05 Ce-144 0.00E+00 0.00 1.61E-05 0.00 0.00E+00 0.00 Sb-125 0.00E+00 0.00 0.00E*00

'O.00 2.90E-02

.1.31 TOTALS 2.97E+02 100.00 4.27E+01 100.00 2.22E+00 100.00 ACTIVITY IS ESTIMATED.

CATEGORY A - 1 SHIPMENT > TYPE A LSA CATEGORY A - 141 SHIPMENTS TYPE A LSA CATEGORY B - 44 SHIPMENTS TYPE A LSA CATEGORIES A AND B BLENDED - 1 SHIPMENT TYPE A LSA CATEGORIES C AND D - NO SHIPMENTS MADE

PAGE 3 OF 4 3.

SOLID WASTE DISPOSITION NUMBER OF MODE OF DESTINATION OF SHIPMENTS TRANSPORTATION 4

TRUCK LIMERICK TO BARNWELL 12 TRUCK QUADREX TO BARNWELL 171 TRUCK SEG TO BARNWELL COMMENTS:

24 SHIPMENTS MADE FROM LIMERICK TO SEG FOR PROCESSING.

2 SHIPMENTS MADE TO QUADREX FOR PROCESSING.

NO SOLIDIFICATIONS WERE PERFORMED.

THERE WERE NO CHANGES TO THE PCP DURING THIS PERIOD.

l l

.=u

, a e

.xn a

+aaw-u-e--+

a.*.-

x--n ae

  • ~. <

-a sea 4

4 e

PAGE 4 OF 4 B.

IRRADIATED FUEL SHIPMENTS (DISPOSITION)

NUMBER OF SHIPMENTS MODE OF TRANSPORTATION. DESTINATION O

N/A N/A t

F

i 1

II.

TABLES D.

OFFSITE RADIATION DOSE ASSESSMENT January 1, 1993 to December 31, 1993 One (1) page is included in Table D.

r i

.A I

J

_-r-g n

<a~

e

,rs-2

t l'

' SITE: LIMERICK UNIT: U1 USER: MART DATE: 02/22/94 10:35

SUMMARY

OF MAXIMUM INDIVIDUAL DOSES TOTAL ACCUMULATION FOR PERIODS:

LIQUID:

FROM 01/

/93 0:00 TO 12/

/93 23:00 GASEOUS: FROM 01/

/93 0:00 TO 12/

/93 23:00 AIR:

FROM 01/

/93 0:00 TO 12/

/93 23:00 APPLICABLE ESTIMATED AGE LOCATION

% OF LIMIT EFFLUENT ORGAN DOSE GROUP DIST DIR APPLICABLE (MR)

(MREM)

(M) (TOWARD)

LIMIT LIQUID TOTAL BODY 7.47E-02 ADULT RECEPTOR 1 1.2E+00 6.0 LIQUID LIVER 1.24E-01 TEEN RECEPTOR 1 6.2E-01 20.0 NOBLE GAS AIR DOSE 6.07E-02 762. ESE 3.0E-01 20.0 (GAMMA-MRAD)

NOBLE GAS AIR DOSE 9.43E-02 762. ESE 2.4E-01 40.0 (BETA-MRAD)

NOBLE GAS T. BODY (GAMMA) 7.61E-03 ALL 965. ESE 3.8E-02 20.0 NOBLE GAS SKIN (BETA) 2.01E-02 ALL 965. ESE 5.0E-02 40.0 IODINE +

THYROID 1.71E-01 INFANT 965. ESE 5.7E-01 30.0 PARTICULATES

SUMMARY

OF POPULATION DOSES TOTAL ACCUMULATION FOR PERIODS:

LIQUID:

FROM 01/01/93 0:00 TO 12/31/93 23:00 GASEOUS: FROM 01/01/93 0:00 TO 12/31/93 23:00 EFFLUENT APPLICABLE ESTIMATED ORGAN POPULATION DOSE (PERSON-REM)

LIQUID TOTAL BODY 1.8E+00 LIQUID THYROID 1.2E+00 GASEOUS TOTAL BODY 4.2E-01 GASEOUS THYROID 2.2E+00

1, c

e t

E i

l I

f 9

II.

TABLES E.

RADIATION DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE SITE BOUNDARY January 1, 1993 to December 31, 1993 4

Two (2) pages are included in Table E.

?

i

TABLE II. E Page 1 of 2 RADIATION DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE SITE BOUNDARY Per ODCM Control 3.6, the Semi-Annual Effluent Release Report shall include an assessment of the radiation doses from radioactive liquid and gaseous effluents to members of the public due to their activities inside the Site Boundary during the report period.

Technical Specifications /ODCM Controls state that Members of the Public shall include all persons not occupationally associated with the plant.

This category does not include employees of the utility or contractors. Also excluded from this category are persons who enter the site to service equipment or to make deliveries.

This category does include persons who use portions of the site for recreational, occupational education, or other purposes not associated with the plant.

The Limerick Information Center on Longview Road near the rear exit of the plant, Frick's Lock Environmental Laboratory on the west shore of the river and the railroad tracks which run above the east shore of the Schuylkill River are all areas within the site boundary where radiation dose of this type could occur.

The radiation doses to Members of the Public have been estimated using methodology stated in the ODCM.

The maximum gaseous dose to members of the public at these locations is based on the following assumptions:

1.

Real time meteorology and actual effluent releases.

2.

Beta air dose attributed to noble gas releases.

3.

Highest exposed sector of the railroad tracks (W), and the sectors enclosing Frick's Lock and the Information Center available for occupancy.

4.

The maximum expected occupancy f actor is a working year (or 25%) in any of the locations.

5.

Distance to the railroad tracks, which pass through the Site Boundary in the W sector, is approximately 225 meters.

6.

Distance to the Limerick Information Center is approximately 884 meters in the ESE sector.

7.

Distance to Frick's Lock Environmental Laboratory is approximately 450 meters in the WSW sector.

A summary of gaseous radiation doses to members of the public at these locations is included in this Attachment.

-TABLE II. E Page 2 of 2 RADIATION DOSE TO MEMBERS OF PUBLIC WITHIN LIMERICK-GENERATING STATION SITE BOUNDARY FOR AFFECTED SECTORS AND DISTANCES APPROXIMATE GAMMA AIR BETA AIR IODINE / PARTICULATE H-3/ BETA-EMMITTER LOCATION SECTOR DISTANCE DOSE, MRAD DOSE, MRAD

_ ORGAN DOSE, MREM INGESTION DOSE, (METERS)

MREM FRICK'S LOCK-WSW 450 6.02E-8 7.68E-8 2.10E-1 O.00E0 INFO.-CENTER ESE 884 9.34E-8 1.19E-7 4.38E-1 0.00E0 I.R.R.

TRACKS W

225 2.79E-7 3.56E-7 9.01E-1 0.00E0

III. ATTAC MESLS A.

SUPPLEMENTAL INFORMATION L

Facility: Limerick Generating Station - Units 1 and 2 License : NPF-39 (Unit 1) and NPF-85 (Unit 2) 1.

Regulatory Limits (Technical Specification Limits)

A.

Noble Gases:

1. s 500 mRems/yr - total body

" instantaneous" limits s 3000 mRems/yr - skin per Tech Spec 3.11.2.1 and ODCM Control 3.3.2

2. s 10 mRads - air gamma

- quarterly air dose limits s 20 mRads - air beta per Tech Spec 3.11.2.2 and ODCM Control 3.3.3

3. s 20 mRads - air gamma

_ yearly air dose limits s 40 mRads - air beta per Tech Spec. 3.11.2.2 and ODCM Control 3.3.3 B.

Iodines, tritium, narticulates with half life > 8 days:

1. s 1500 mRems/yr - any organ

" instantaneous" limits (inhalation path) per Tech Spec. 3.11.2.1 and ODCM Control 3.3.2 2.

s 15 mRems - any organ

- quarterly dose limits per Tech Spec. 3.11.2.3 and ODCM Control 3.3.4

3. s 30 mRems - any organ

- yearly dose limits per Tech. Spec. 3.11.2.3 and ODCM Control 3.3.4 C.

Liquid Effluents:

1. Concentration s 10CFR20

" instantaneous" limits Appendix B, Table II, Col.2 per Tech. Spec. 3.11.1.1 and ODCM Control 3.2.2 2.

s 3 mRems - total body

- quarterly dose limits per s 10 mRems - any organ Tech. Spec. 3.11.1.2 and ODCM Control 3.2.3 3.

s 6 mRems - total body

- yearly dose limits per s 20 mRems - any organ Tech. Spec. 3.11.1.2 and ODCM Control 3.2.3 2.

Maximum Permissible Concentrations Per LGS ODCM Control 3.2.2, MPCs are not used to calculate permissible release rates and concentrations for gaseous releases. The MPCs specified in 10CFR20, Appendix B, Table II, Column 2

for identified nuclides are used to calculate permissible release rates and concentrations for liquid releases.

cop mn I for identified nuclides are used.to calculate permissible release rates and concentrations for liquid releases.,

3.

Averace Enercy "ised on gaseous effluent releases for the report period, average beta energy is 0.303 MeV and average gamma energy is 0.245 Mev.

4.

Measurements and Anoroximations of Total Radioactivity A.

Fission and Activation Gases The method used is-the Canberra Series 90 Counting System; GS - Gas Marinelli.

B.

Iodine:

The method used is the Canberra Series 90 Counting System; CH - Charcoal Cartridge.

C.

Particulate:

The method used is the Canberra Series 90 Counting System; PT - Air Particulate Sample, 47 mm filter.

D.

Liauid Effluents:

The method used is the Canberra Series 90 Counting System and the Radwaste Liquid Discharge Pre-Release Method with a 3.5 liter Marinelli.

5.

Batch Releases A.

Licuid Q1 91

  1. of Batch Releases:

73 130 4,654 8486 Total time period for batch releases, Maximum time peried for a batch release

  • 120 85 63.8 65.3 Average time period for batch release, 4

50 Minimum time period for a batch release, i

Average stream flow (Schuylkill River) 3.44E5 1.22E6 during periods of release of effluents into a flowing stream, gpm.

B.

Gaseous

  1. of Batch Releases:

0 0

Total time period for batch releases, 0

0 Maximum time period for a batch release, 0

0 Average time period for batch release, O

O Minimum time period for a batch release, 0

0

6,.

Sb21prmal Rele&Sfta A.

Liquid None B.

Gaseous None 7.

Description of LGS Effluent Release Points Release Point 1 = North Stack, Common Release Point 2 = South Stack, Unit 1 Release Point 3 = South Stack, Unit 2 Release Point 4 = Hot Me.intenance Shop Liquid Release Point = LGS Liquid Radwaste Discharge 8.

Description of LGS Liquid Dose Recentors Receptor 1 = LGS Liquid Radwaste Discharge Point Receptor 2 = Citizens Home Water Company Receptor 3 = Phoenixville Water Company Receptor 4 = Philadelphia suburban Water Company Receptor 5 = City of Philadelphia Crew Course t

?

t a

r w

-r-

III.

ATTACHMENTS (continued) l l

l B.

RADIATION MONITORS OUT-OF-SERVICE CONDITION l

On 10/14/93 at 2050, the Unit 2 Service Water Rad. Monitor was declared inoperable based on the monitor being in a Low Flow Alarm condition. (With a liquid effluent monitor inoperable, ODCM Control 3.2 Action Statement 101 was entered.

This action states in part:

With less than the minimum number of radioactive liquid effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table I3.2-1.

The ACTION from Table I3.2-1 states in part to take grab samples and analyze for radioactivity by gamma isotopic analysis at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

Pursuant to the ACTION Statement, sampling was initiated at 2150.

The Service Water Rad. Monitor Low Flow condition was rectified by replacing 100 feet of sample piping.

The Unit 2 Service Water Rad. Monitor was declared operable on 1/26/94 at 1425.

Service Water sampling frequency was maintained during the entire inoperable status time frame (10/14/93 2050 -

1/26/94 1425).

e t

L

.rw,

-c y

F III.

ATTACHMENTS (continued)

C.

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING LOCATION CHANGE.

Milk farm 25B1 (1.3 miles, WSW sector) went out of business in March 1993.

.It is one of the three(3) semimonthly milk farms and was replaced to comply with ODCM (Rev. 11) Table I3.4-1 i

Section 4.a.

The milk farm with the next highest dose potential is Farm 19B1 (1.9 miles, SSW).

Milk Farm 19B1 has replaced Farm 25B1. All required sampling occurred during the transition.

v

1 1

i PAGE D1 l

III.

ATTACHMENTS (continued)

D.

REVISIONS TO PREVIOUS SUBMITTALS A problem has been identified in the values reported in the Semiannual Effluent Release Report No. 18 (January 1, 1993 through June 30, 1993) for the total amount of fission gases released from the Unit 1 and Unit 2 South Stack and the North Stack release points.

The computed values reported were conservatively high.

The corrected values are attached as pages D2 through D15.

A typographical error was identified in Semiannual Effluent Release Report No. 16 (January 1, 1992 through June 30, 1992).

The error was in Section II. part C.

SOLID WASTE DISPOSITION REPORT.

The Solid Waste and Irradiated Fuel Shipment time period was reported as 7/1/91 through 12/31/91, but the shipment activity was correctly given for the period 1/1/92 through 6/30/92.

The corrected page is attached as page D16.

i j

4 4

w

PAGE D2 l

i MITE: LIMERICK l

JNIT: U1 USER: MART IATE: 01/11/94 10:39

' EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS FOR RELEASE POINT:

1 NORTH STACK CONTINUOUS MODE BATCH MODE NUCLIDES

UNITS.:

QUARTER QUARTER : QUARTER QUARTER RELEASED 1

1 2

1 2

2e 20 DINES I131 CI

Oe646E-02 : De449E-02 : 0.000Ef00
  • 0.000Ef00 :

I133 CI

Oe298E-02 : 0.230E-02 : De000Ef00 : De000Ef00 :

TOTAL FOR :

^.000c'0^. *

^ e ^. 0 ^. r. t' ^. '

0e944r-O'.*. Oe787

-0'

  • e or

.e e.

.c.e p.T e.n C.'

e e

e e

e

( Ao0i)e) e e

e e

0. 4..C.T. * *L h.6. T 7 C.

t

i. e 1

w e. A. r. e. T V.inoe. e, + 0 ^ 6. -. n. ^.

A A

ariAA.

b w

v t.

A.. A. A. U.T v.

L. e ^ 6. e r ' A a.

r.i a.

c T.

+

V J.Tvb e e

w e

e

^

^A e.

v e v. 0T 4. A. A.

A.. A. b. 7 ' r A.

^6 A. e.a rJ. r 4. A. A J A.

A*Ar A. e. V L

a. A. A.

TJ e

FT

r. O.. E.1 w e e

A A ^r v e. n. V. a. n n.

A. e. i. b. r 16 A A

  • V e V ^ A..r 4. A 0
  • A.. A. A a r 4. A A.

v e

A ^

. Tov e

  • T.

sV. v W

. dJ.R..I L

V v

e e

^ ^^^

^ A V e V V V. C. a. ^ rJ V a. A. A C 4. ^V.A V. V 'J V. 4. ^ A.

^

^^^f V

e V e. A.f. L" A n ^

^ A V-e C.P M. Q.

F. T V

ivv e e

e e

^ S,a ar. Y A. A.

e, v e. A. A. e. 4. A A A A e

^

e

.a, e. A. A.. Y V ^

VetJv A

n e A. e. a a r a o. V n

F.*. c =

r; e.

L V e ss e JL-e e

e e

-s-.

Je.n^C.r?J/ e A

r r f*!C.T.A iA n

  • L

?.e t. r. k. ^v.

A. k. C A. r A.

kV.

AA.

J e

ri-.

.e see.

v e

. n.L?

e e

e

- - -.. - -... - -.. - -............................ -... - - - -... - -... - ~ ~ ~....

O e. f. ?. r. ;. 0 A.

A e...* *

  • 7. T' A. S,
r. e. A. A. T A. A. A.

?

A

.. A. m. V; A. 0 A.

e

.;4..;.

.e F*

+

e

^A r.V. ATLA'.

A.

A A A. " a. A A.

A. e ? A.

  • r A, A. f.

A.

" A. A. c. A. r. t J

v.

w F*

vv C u e

C C. C :

e

^ A nr 4

v e. A. V. 4. v*. A.

f., e.a*.3 7 4..* O, f.

e A. e. A. A.." A. A. A A

A.eJ0V Tv.^rinA

  • A e
3..*.. '*)

. T.

t e

^ AA V e v. o. r a. r. A.

A. e. r. f. r A. P A f

. Js e A.. S. q V Y ^ A.

.^r A.. A. ^ ^ r 1. A A.

  • e e

i.t.e. r e.

. T.

V e

VV-v e

4 V^ a. n d " A. A. A A

A e.

  • A. *L f A. A.

A

. e "<. A. T A. r f JL s

.S A.. A. A. A. 4. V.^A e

. :

  • t..".1

(.*.

e e

e V e. A *.T. A. P A.

^ A A. e. A. A. f 4 6. fJ

  • A

.. A. A.

  • T a. A. A.

vb J

e A..A.V.r4.f A.

  • A.

J e

T e

P r..e i a.

e L.

e V e VV w 16 ^J ' *e

^

^^A Q e. A. f.i.1. ^ Q

  • e M

C Ves AC.A. A.A.

^ Af A.. A. A A..r 1. A. A V

e<

e

.T J

e

,0171 V

v e

.s e

e

..----.............----.........---.............-.....--4..--.---.....

O e. A. A. 7 4. A. A.

A.- e. f A. C A. A. A.

A.. f. 0 6 ?. L. A. A.

A.

  • 6. ? *s: f A. A. 'e A

e OJ

,e

. C.t i. *.

L.

e

=.

M' T..* M t i r L

T B.a# C. 7 C. r. O C C.),f ' n" n"t9

.ON770 f.

r.

T A.

utt r

.e

. a 1

l

-~

PAG *E D3

' SITE! L2MERICK UNIT 2 U1 USER: MART DATE: 01/11/94 10:38 EF' FLU,NNT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS FOR RELEASE POINT!

1 NORTH STACK CONTINUDUS MODE PATCH NODE

NUCLIPES : UNITS :

QUARTER QUARTER GUARTER : QUARTER

RELEASED :

1 2

1 2

1. FISSION GASES i
AR41
.CI
0.000Ef00 : 0.000E400 : 0.000E400 : 0.000Ef00 :

l KR83M CI

0.000E+00 : 0.000Ef00 : 0.000Ef00 : 0.000E+00 :

l 1

1

KR85M CI
0.404E-04 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
KRB5 CI
0.11EE-03 : 0.000Et00 0.000E+00 : 0.000Et00 :
KRE7 CI
0.000EiOO : 0.000E+00 : 0.000Ef00 : 0.000E400 :

s..(s. :fn.0 0.000E.+00 A*_

h:: B o.,

..?

n.. n. e. s. _::. v" A.

e. A. r. n. e : A. r KRB9 CI

0.000EYOO : 0.C00Ef00 : 0.000E400 : 0.000E400 :

A..A.C.rC_fr0 0.000Ef00 A.. r., a.r :"l. i.b"s

6.. r A. A. 7 4. P h'h' 9 &.

I.' ?.

s s.

s

XE131h CI
0.000E+00 0.000Ef00 : 0.000Ef00 0.000Ef00 :
X E 133."

l CI

0.c04E-02 : 0.000E+00 0.000Ef00 : 0.000Ef00 :

Lc.t i, er 0.. c.. : : a. A.

A.. w.. c _ s.

A.

0 0 A. :_4. s. e,. n. 0 0 C,.r.4 0 0 i.

. e. 0 0,0 e.+ n 0 Le..t m...

r..*
n.. n.s. r e. v r
r...a e, c. r t. e e.

0. A. A. r.,.e f.) n.

o

.s v.

A..O '.t.* O.*..*..

f. e.t.* P t' a..* *....

A..A.A.**47A.

. V.AAAr.TVVdww.IAA

. A

.?

V C.17. c'

.J v

^_.

e A. A&.AfIr ^V b. P *. F..T A. t' P

.*?

f. A. ? A..T A. A..*.

A.. * * /* T A. A. r a _.1 7. "/

Yr db v v v67 f Y C.T r..w.

1 1

h J 4 c. O. i, 4 0 * ".r o.

A. ;..

a...

e.., ss.a

(__..

."..' r. 0.W..

a t.f.

s L, ? H..H. i.M. 8.!.* Pt..i nN;. c.

t.a.

As.tt.t v.

A.n.e D..M. 1.4 f t'I.t.M..L.e. o 1

AT

"'.M. :.1 &..f T.. ".

Q 1./.t i./ C. /ll

.t r

  • 7 3. *. A. wR U

t

. a n-

. A A. P..". 4. A. A.

A.

7 0 hOf A, A.,

0.

  • r A. r a. A..\\

. ?. A. A..r a. *. i a

./.r. 4 T. O

.a*

s n T e. i r_..

J F. C. D...T A..T.

r.?

0. 9
u. ; a. A..t t.i. s.a, '.t ; + A.
  • p. 0 r. o. * + 0 L,
0. e 6 0.e. 4 00 s

u.n

f. H r v (j e.g

...d.

.,..__.1 n...$

4....t.

e L.

.1._h 9

~

i l

FAGE-.

94 SITE! LIMERICK i

UNIT: U1 USER: MART LATE: 01/11/94 10:29 l

1

' EFFLUENT AND UASTE DISPOSAL REPORT DASEOUS EFFLUENTS FOR RELEASE POINT:

1 NORTH STACK i

CONTINU0US MODE PATCH MODE HUCLIDES

UNITS :

QUARTER GUARTER

QUARTER :

QUARTER

-RELEAEED :

1 2

1 2

3. PARTICULATES (CONTD)

BA140 CI'

0.283E-05 : 0.000Ef00 : 0.000Ef00 l 0.000Ef00 ;

l CE141 CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 0 000Ef00 l

CE144 CI.

0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
r. n T A_r.e n. a..

CI

0.2c2E-05 0.000Et00 : 0.000E+00 : 0.000Ef00 :

( A. o.- n...5

. s

..M. *..". O..P r.

1 T. C.

C.D. A C E

. -., C.c c r N A.kLfi C 01.l*4.T.H il; C

w-TOFCOMr 11-JAN-1994 10:40:0o.14, messsse from user SYSTEM 01/11/94 10:40:05 OMUPDT: CDMMUNICATICNS IS FAULTY ON RM-11 HUMPER 1 e.

9 t

i e

3, e-w.-

.,y

FAGE 93 SITE! LIMERICK

. UNIT:.U1 USER: MART DATE: 01/11/94 10:40 EFFLUENT AND UASTE DISPOSAL REPORT GASEOUS EFFLUENTS FOR RELEASE POINT!

2 UNIT 2 - SOUTH STACK CONTINUOUS MODE FATCH MODE NUCLIDES

UNITS :

GUARTER DUARTER 1

QUARTER 00ARTER 1

R i A.

I,.

1

.t

1. c.re=rnfa. GAc S s_

AR41 CI

0.000Ef00 0.000Ef00 0.000Ef00 : 0.000Ef00 KRE3M CI
0.000Ef00 0.000Ef00 0.000Ef00 0.000Ef00 i

l MR95M CI

0.000Ef00 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

1 l

KRE5 CI

0.000E 00 : 0.000Ef00 : 0.000Ef00 : 0.0C0I400 :

+

KR??

CI

.0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

.t.\\. l.', fs. ? f n. 0 *. 0. *.* n. n. t.* L. C. v%

  • 0. n. o. t..s. n. a.

n.

V..*. C ;

f' I

n.. S. r. n. *. A. n. %.
n. 000efr0 0.00,0e+0n.

0. n. 0 n. e. r. 0 0

+

.r..e..= =

cI

n. 0 a. n. :. A. n. n.

s M * ? '.

C!

0.000EYOO : 0.000Ef00 : 0.000Et00 : 0.000Ef00 :

XE131M CI

0.000E'f00 : 0.000Ef00 0.000Ef00 : 0.000Ef00 XE13?P CI
0.000Ef00-0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

n..en.0ei.n,0 0.0r.C. 400 0.n.Orr;_:1. 0 0.,

y : <.,.

e. r.

n n.,.~.e : z.. n.

s

. s XE115M CI

0.000Ef00
  • 0.000Ef00 ! 0.000Ef00 0.000Ef00

.v.e.s v..-

' 2 a,.. i t. :.a. n. n.

n,,. a. 0 C.c a. 0es *. 0.0t0 1.a.n.

0.n.00ef 0n,,.

n t

0.0n.eef00

n.. n ~ 0 e s. 0 n... 0. 0 s. n. e t. 0 s_
a.. n. e.: n..-

.v. = 1,

Cr sv sc-.

XE173 CI
0.000Ef00 : 0.000EYOO : 0 000Ef00 0 000Ef00 :
v. n. e. n...e n.:.

0. 0 r 0e. t. 0 n,,

n.. v. 0 c 2. 0 C.

0. 0 n. 0 e r. a. n.

sn _

n.. o. 4. : n. e.,

s c r..e. n. r.

e..r 2..

a I s. t. i.:Ls t. r e

r. u. t. r_ e-.,,. Tea :.:. Ae.r.

e.r.' c.e.r.n.. H N *, C C et i.1o.r

.n

n. e. e c g. o. f,m use SV.C77.M t.rA...t. t c. c. 4

.1 n. 1.1

  • A. c.

2,. t P. O F n..W. r e n..w.y.n p.. e.g t..t g y

.t S F A'.".T Y O.N O.M..' 1 N"_ P. ro..

-1

.. / _1_1/ e.1..

1 o

f. 5. n., x O Mn o r,..

.2 4,

%0?COM: 11-JAN-1?c4 10:42:09,12, messace free user SY5 TEM COF.".." M.~ F..IO NC. f c. F A.U'. T Y ", a"

.e. x. $ '.. N ". F. 5 e. R' ' 1

n..i.r i.i./ g a. 10 4,. *. O*.

O M". > T.i.

a.

9 m

r m

m m.

mi a.

i

PAGE D6 3fTE:.LIHERICK JNIT: U1 JSER: MART

) ATE: 01/11/94 10:42

.IFFLUENT AND WASTE DISPOSAL REPORT 3ASEOUS EFFLUENTS FOR RELEASE POINT: 2 UNIT 1 - SOUTH STACK CONTINUOUS NODE PATCH HDDE NUCLIDES UNITS :

QUARTER :

QUARTER QUARTER QUARTER R.eL E AerD 1

.n 1

.n u-

2. IDDINES I131 CI
0.000E+00 ! 0.000E+00 : 0.000E+00 : 0.000E+00 :

l 1133 CI

0.000E+00 1 0.000E+00 0.000E+00 : 0.000Ef00 :

TOTAL FOR :

PERIOD

CI
0.000E+00 : 0.000E+00 : 0.000E+00 : 0.000Et00 ;

(c )

, A.s c

.. c s o. 1 r_ bn_ H l r. c

.h.

. v. 0 e+ 0 0

  • 0. A. 0 A. r + 0 0 *. 0. A. A. A. C f 0 0 *. 0. 0 0 A. E A. r 0 *.

no _

.4 F..t CR!!

CI

0.461E-04 0.144E-Of : 0.000E+00 1 0.000E+00 :

A.. C.C.C, r + 0 0 *. 0. v* A. n. E + A. C.

  • e. A. C o. r 4. 0 0 *.

A...) A. p r 4. A. A.

we-24 C?

.s e

FE59 CI

0.000E+00 1 0.000Ef00 : 0.000E+00 : 0.000Ef00 :

A.. O. ^.] c 4. A. A.

L" A. 9 0 C.?

A. o. n.r 4. 0 0 * ^. A. A. r r 4. A. o.

v. 0 A

  • f 4. 0 A.
  • ^

u.

.6 v

e v s.

s e s. A. _" 4. A. A A.. A. A. A _r 4. A. A.

AA

  • ^

^A

  • r
f. A. A. A. r i A A v. A. A. A. C f V.

r ? 4 A.

L.

v e v

e

.Tvv.

e

. A. r. a C. 4. A. A.

(.. A A. e..r 4. A. A.

. ^

a a.

,a. A A. A. r i o. (/

V. A. A. A. r a. r. V e

r. ?

" f. r_,

+

e J v

.T e

e e

A. e. S. A. P a. r. A.

A.. A n r. r + A. A.

A s

A.. A. r r..* 4. r. r A.. r A A..r 4. A ^*V.*

...- Q C.

L".?

e so.

e

.. 0. A.

P.T A. + A. A. A. C + ^ ^

A...*. A. *. f 4. A. A.

A.. A. A. A..* 4. L, A.

J. A. A. A. r a. r A.

^

____.________._____.____.....__'V

. b e

A. e J. A. P 4. A. A.

AA e

A. + A. ^ ^ r l A ^

A.. B. A. A. C 1.s A A.. P. A. P

  • 4, A ^

_9

  • O. t
r. *.

L e

Vb TvV e

.Tk e

. vV e

/

e.. s. A. 0. t. A. A.

s. A 0 r e a. 0 0. C.

A..e s. A. r.

r. A. e..

x. A. cA.

s es<n e:

s.

..._i.

A.. r A. A r a. g C.

  • A.. ^. ^. 0 r + ^ ^
  • : 4 7. 4
e. i A.. Q Q Q.r 4. Q A.

Q. r A..*. c r. e. r s

e A.. A. 0 t r + 0 0 *. 0. r' A. r e 4. A. A.

o.. A. A. *. r 4. 0 A, 0. A. C. A. r + 0 A, 4
c..:.t i. c-cI.

9.

s.

e A.. A. o. n E 4. e. A.

A,. u s v* E + 0 0 *. 0. A A. A. r + A. A.

0. A. r. s. r a. t,an ar

c. :.e 7..

C7 s

e ENTER E C ] TO ERAEE SCREEN AND CONTINUE :

C

PAGE g

38TE.LIMER2CK JNIT: U1 JSER! NART JATE: 01/11/94 10:42 EFFLUENT AND blASTE DISPOSAL REPORT 3ASEOUS EFFLUENTS FOR RELEASE POINT! 2 UNIT 1 - SOUTH STACK CONTINUOUS HDDE BATCH NODE NUCLIDES

UNITS :.00ARTER QUARTER DUARTER GUARTER RELEASED 1

2 1

2 i

1

2. PARTICULfTES (CONTD)

PA140 CI

0.000E400 : 0.000Ef00 1 0.000Ef00 1 0.000E+00 :

o CE141 CI

0.000Ef00 0.000Ef00 : 0.000Ef00 0.000Ef00 :

i CE144 CI

0.219E-04 ; 0.000E+00 0 000E400 0.000E400 :

TDTAL FOR :

PERIOD CI

0.680E-04 : 0.144E-06 : 0.000Ef00 0.000Et00 :

(ABDVE) i.

ESTER I C ] TO ERAEE SCREEN AND CONTINUE :

C 1

i I

j 4

9 9

1

[

i s

a t

4 4

t a

4 1

v

PAGE

.D8 SITE!. LIMERICK

' UNIT: U1 USER: MART DATE: 01/11/94 10:43 EFFLUENT AND WASTE DISPOSAL REPORT tl' GASEQUS EFFLUENTS FOR RELEASE POINT:

3 UNIT 2 - SOUTH STACK l

CONTINUOUS H0DE BATCH MODE NUCLIDES

UNITS :

.0 VAR ETR OUARTER QUARTER i QUARTER 1

.n F r.i.E. Ae.E.r 1

.S. I nJf.T h'T S 1131 CI

0.786E-05
  • 0.000Ef00 1 0.000Ef00 0.000Ef00 :

I!33 CI

0 326E-04 0.000Ef00 : 0.000E+00 0.000Ef00 :

, C,7. AL r n..e.

D e ^ v^ A r + A. A,

.e v e v 00r a. v^ u a a m e a. v. 0.r A. A. A.

AA 0.80gr_^s a

e e e

a*

C.C.O..T 0.fa L.

v v

.v

  1. . 4.*. rJ V.c )

e.

7. e D..S.D.T. T P U' A T. r. r.

L 0. ^ ^ A. r 4. A A.

+

A. 0 A A..r 4. A. r; 0.00frf0A C e 0 A. A. C A. A. A.

+

L" 7 vv J

S..i rI e*

J v.

v V

t,. A g or'. 6. 0.'

A. A A. A. r. 2. p A.

e A.. '*J. A. C ' A. 0 * ^. v^ 4. A. r 4. A. A.

A

.t

. v

r..D. M.1 C.T J _

v v e

.. o< e 4

e..r C. 6A.t.r.07 0.030r4.0A.

0. 0 A. A. e 2. *. A.

0. 0 0 0 e 4. A. f.,

w.

FE30 CI

0.000Ef00 : Oe000E+00 : 0.000E+00 ; 0.000E+00 :

A.

0 c^ Ar.a. v^ ^

0.0^0.TA.A.A.

0.0A.o.r.a.0A.

C M. E. C.

LJ

0. A.0A..CI A. 0 e*

v v.

v T

O. '^/ ^ A. r 2. A. m

  • A. V ^ %. r 4. A. ?.

A.. A. A. A C A. A. A.

^

^

V.1997.^4 P n. 4 A.

f..*

s V

J.

V.

k V.

w,

3

/.

e

+

=

i A.. A A A. ra. A. V A.. A. A. k,.r J. S. A.

A.. o. f. f. " a *. S.

.. A. A. A. r a. r. A.

^

  • a
  • ^

_~ N. A R.

P. T vd.

.w N.T J.

i. e. A. A..T A. A. A.

A e. 6. f r a, f fJ A.. A. E. n. t. 4. P. A.

V. A. A. *.

  • a r..*

A

  • ^
  • A 00..33 w

b, e J O C.r.a. n. Ci *.

A.. A. 0 A. r A. A. A.

A.. C, A. n. r a. 0.*

A.. A..* A. r. J. A. A,

+

+

  • e 200.6
e. 7

+

f. n C.f

  • 4. :s.A c a. o. o. rA. A.

n e

A J o. A. f. is. o. f)

A r

. ' e s 0 A. ra. 0 0

  • e
  • A

...'. O. m

.~ T.

9 J J JL a'

e A.. V. f..". A. f fe t'. A.." ;. A. A.

A.. A. A..*." A. f. ?.,

^f

^*

A. eV J.r4.A.A Afo.

..s.'.9 4 r.?

e e v

s v. A. v^ *d.a. o,0 *,

^

r

?.:.: 7. M P..T A.. V 0 0 ~4. A. A.

A.. A. A. f r a. A. A.

A.. A. 0 A. *.1. A. A,

^

t e

__e..............

  • ^

f. A. A. A. *. t' A. A.

v. A. A. 67 4.A. A.

A.. A. A. A. C '. A. A.

F. 017 4 F. T 0. A..h^, r 1. 0 A.

J i

J t...

.J e e

e. y e T _T.w.

1 1. f a r. t o. e. 9 1 A..* 14

  • A. 9 e.11.F
  • ' n. t a n..w.

m e e.e., n.

.Ht.

6.

s.

r. n M.M o..n..t [.4. T..i e. ni e*e { g u.t. T. v.

n y Q..M. 1 1.y n..W.% c w 1 A. +. M.. o. t.

n..w.y o.ri. *

  • d.

T.

e94

/

n..i.r.i.g J

w.

.3 A.. A. A A. r a. f V A.V A.r.a. AA.

^ *

^r

+

f s. k... r a. f fJJ.

A^*

v e v v v L" 4. ^ ^

^ ^^^

. c.1

  • 7,
f.
  • v V

v.

vv.

w e

.s...m...__..._me-m..p...m_...e........_...m...mm.._.........mm........

C_ u.

e.. r C.,. i. n. r e.. r e. r c. r. o. r. r u. e N n. e. n e. T..t N o. r a,

r

.4

=

i PAGE 39 j

S3TE: L3HERICK 3

UNZT: U1 USER: MART

%0PCOM, 11-JAN-1994 10:43:09.13. messase from user SYSTEM R

01/11/94 10:43:05 ONUPDT: COMMUNICATIONS IS FAULTY ON RM-11 HUMBER 1 DATE: 01/11/94 10:43 1

EFFLUENT AND WASTE DISPOSAL REPORT g

9 0ASE005 EFFLUENTS FOR RELEASE POINT:

3 UNIT 2 - SOUTH STACK j

i s.

CONTINU0US MODE FATCH HODE NUCLIDES

UNITS :

QUARTER GUARTER GUARTER OUARTER RELEASED :

1 1

2 1

2

1. FISSION GASES AR41 CI
0.000E+00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

KRS3M CI

0.000Ef00 : 0.000Ef00 : 0.000E+00 1 0.000E+00 :

KR95M CI

0.306E-02 : 0.000Ef00 : 0.000E+00 : 0.000Ef00 :

MR85 CI

! 0.000Ef00 0.000E+00 0.000Ef00 : 0.000E400 :

MRS7 CI

0 000Ef00 : C.000E+00 : 0.000Ef00 : 0.0C 0E l-00 :

KRS8 CI

0.000E+00 0.000E+00 1 0.000Ef00 : 0.000Ef00 :

l ERSC CI

0.000E+00 : 0 000E+00 : 0.000E400 : 0.000Ef00 :

ER 0 CI

0.000E+00 : 0.000E+00 : 0.000E+00 1 0.000Ef00 :

XE121M CI

0.000Ef00 0.000Ef00 : 0.000E+00 : 0.000Ef00 :

XE122M CI

0.000E+00 0.000E+00 : 0.000E+00 : 0.000E+X :

.V.O 17 7 C?

A.

6 09.C4 6. 4 0.1.1 9 7 4. 0 A.

A.. S. A. A. E. A. S.0.

$.. 0 6 6. _7 4. A. e'

3.. n o. r. e. t. e.
0. 4.o. r n. A.

S n. a..r + n. o.

. n 00, E + 0 n s

v.r.i. t. u.

7. 7

_v t.

?s. a. n e. r.. c. ?.

.v.... n.

r. -

A...s a. 4 e r. 0.,

. o...n i.s :+ 0.,

n,. 0 0 e.r.+ e.

s.

XE177 CI

0.000Ef00 : 0.000E400-0.000Ef00 : 0.000Ef00 :
0. ?s 0 o. r a. s..,

. ir

...... - - _ _ _ - _ _ _ _.. - -.... - _ _"t. 0 0,.

A.. A. n. a. r. 4. A. 0

6.. S. A. A, r A. 0 A, r.n.06 4

.N.r.1 7. :

P. T s

u t

.nr.n.

e.n e.

. r.

e e

C. 4K0C+09 C. 9 4 0 01. 0.*,

A.

0.) 0.C + Ci C A.

0.% A..C A. ) ".

.O.r *r. ?. A..h C.T

..s

, A o r,.(ie )

ENTER E C 3 TO ERASE SCREEN AND CONTINUE :

C

=

1 PAGE.

DIO c.r T.r.e. L f M e R.I CK

. UNIT: U1 USER! MART DATE: 01/11/94 I0:44 EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS FOR RELEASE POINT! 4 HOT NAINTENANCE SHOP CONTINUDUS HDDE BATCH NODE 1

NUCLIDES

UNITS :

QUARTER :

QUARTER QUARTER 00ARTER 1

Er.i r ASrE.

1

!. FISSION GASES AE41 CI

0.000Ef00 0.000Ef00 0.000Ef00 0.000Ef00 :
KRSIM CI
0.000Ef00 0.000Ef00 : 0.000Ef00 : 0.000E+00 :

KRSSH CI

0.000Ef00 : 0.000E+00 : 0.000Ef00 : 0.000Ef00 RE5 CI
0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :

l KRP7 CI

0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.00)Ef00 :
f. e. a. nr e n. n.
f.. n. o. n. : A, e. r.

S Ce. An. ^ ra. n. n.

e. Q nJ ^ r a. nJ eA.

.r: C C.

F..T J

V.

v y_

s...

A.,3 C,n. r a. n. 0.

n. 0 0 C.E. + C,0
n. 0n.0:_4. 0 Ca
0. 000.r4. 0s.

C. r". :. C.

P. T.

s A.. n n. 0 t. n. C..

F4

n...S e. c. r J. a. h.

^ f 0^~4. ^b,03 b. n. V. = 4. 0. n.

n an.

r *.

s h':o. rJ O

v.J VL e

.Y..:.1 7..t M.

C*

0. 000 7_4. 0 n.

0. 0 0 0 F 4. 0 0., n...)n. n. :. A. n. 0

n.. a. 0 n. _r 4. 0 0 0. ^v 0 ^ _r 4. s. n.
0. 0 0 ^ c"f 0 0. v^. n. '^s. e. n, r
e.. n. n o..r + 0 0 n.

.Y..:.1 *J. M.

._.T s.

T.

v v

A..<,.

e. r.

0. n. n. :; r :.

0. 0 0 n r.1. C.C,.

n.. e. n. n. v.a. n. n.

s. n. n. 0 r f n..)

~

..J.

s

.v... z.u.

e.r

n. 0 n. r e x. 0 3.
e.. n. r. 0e.s. a. r.

c. r n... r... s.

.. s 0 C r.s. s e v.e.4 v. c

e. r C. n. n. a. r.. n. r.

r 0 n. a. r n. =-

n.. e r.
n.. )n. n. _ i. n, C..

.. n. e. n.. n. ?.

n. 0,)n. e s. a.n.

... r.. e s. e. r

s.. n. n. n. -1. n. )

c

e..r A.. r n. e. c. t. e 0. n..., n. 0 e r. 0 n.

y r.i t. e

e. t v. n. n. 07 4. \\ e.

e 000.ra.rr s

....,:::n_

.*u..

e..r
n.. o n. ea. n. ?.

r g o o r.. e. r.

e...

  • . r.er

.. n. n. o.: s. s. e

. ::: r..

n: D....e a r 6' ?..? 65 s.t r a.

\\. *.

.r.u * ::..... r..i i. n

_7 " A C :

.? P. r..r e..n$ i. t...O M

.t r ri

r..v *..:.-

?.

7 T. 9 C. S...A..*.:C. F. D.r.- >}

.4. 6l.f.. n. nI *..t.u l.l.e.

s 1 1. l M.

1 C. y* 4 1 A.. A. r.. v

.1 1

. e c. e..,d e a

.. e. r O V. C. T. : M.

.nc

".?

.a n. M. r

.s.

.. unu.cenn t.c At1T.v. r D.I ow_g.

  • .* F. M. M.I ' 8.t' T ^ ^ T. t n u c.

".M. 'L. h'8.

U I t.-

.i d r

i. n.. d. M. '. a r ra a..

. s. J.bn 4 W Tf

n..t.f.f s./ c,..t e

JJ

?.

As.

l

-PAGE D11 38TE: LZHER8CK JNf T: U1 JSER MART

' IATE: 01/11/94 10:44 IFFLUENT AND WASTE DISPOSAL REPORT 3ASE00S EFFLUENTS FOR RELEASE POINT:

3 UNIT 2 - SOUTH STACK CONTINUOUS MODE BATCH MODE HUCLIDES

UNITS :

GUARTER QUARTER OUARTER QUARTER RELEASED 1

1 2

1 2

I. FARTICULATES (CONTD)

PA140 CI
0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.000Ef00 :

l CE141 CI

0.000Ef00 0.000Ef00 0.000Ef00 : 0.000Ef00 :

l CE144

CI
0.000Ef00 1 0.000Ef00 1 0.000Ef00 1 0.000Ef00 :

0TAL FOR :

i

?ERIOL CI

0.194E-06 : 0.000Ef00 : 0.000Ef00 0.000Ef00 :

(APOVE)

ENTER [ C I TO ERASE SCREEN AND CONTINUE :

C i

e

rau' D12 SITE: LINERICK UNIT: U1 e

USER: HART DATE! 01/11/94 10:45 l

l EFFLUENT AND WASTE DISPOSAL REPORT l

GASEOUS EFFLUENTS FOR RELEASE POINT:

4 HOT HAINTENANCE SHOP 1

BATCH MODE CONTINUOUS HODE e.

NUCLIDES

UNITS :

DUARTER 00ARTER QUARTER QUARTER :

RELEASED 1

2 1

2 2e 10 DINES I121 CI

Oee14E-05 : 0*000Ef00 ! De000Ef00 : Os000Ef00 :

1122 CI

Os000Ef00 : Oe000E400 ! 0*000Ef00 : De000E400 :

e e

e e

e e

TOTAi_.e n..e.

e e

e e

e e

e e

PERIO~

CI

Oe914E-05 : Ce000Ef00 : 0*000Ef00 : Oe000Et00 :

e e

e e

n.

i. A e.. )

i e

e e

e e

e e

7.o a C' A.2. ". 7.* 6.M. a* T.1" C C14 CI Ce000Ef00 ! Ce000Ef00 : Ce000Ef00 : De000Ef00 :

e O e. r. o. e 2. 30 e O e 0 0 A..r a. n. 0 e A

n. 00 A. r.4 0 0 e A

e e

A. e. 3 0_e f 0 vn e

x. I e,

r_ ?

e e

.t.

e e

e HN54 C:

Oe0005400 : 0.000Ef00 : Ce000Ef00 : 0.000E+00 :

0 * ^ ^ r..r a. v" 0 e A

^^A v e v v. r.a. 6" 0 e A. e. ^ $. _r 1 A. A A

e A. e. 0 0 " f ^ A.

A t v e

e

.?

e E.T C O.

e e

vv e

v T v e e

r.

e e

e A ^^

e V s. r. A..r 4. A. ^J v e VV0r.. pJ, e

a A se.Vv_T.AV e Aang e A e

(, e. 0 A..r 4. A. V A

A e

e a

e r

e

r. '"e J.s e

L e

e e

e

.........=_..........

A. e v. r. r. a. ^,r) v e, A. a r.a. r, o.

AA e

A, e. A. ^.r.f 0 A.

A A e

A A. e. A. A. ". 4, A. A A

F. A. / A.

r. ?

e e

e v

e e

Y e s

e A.e

^^ra.reJJ e A

e A. e.

  • f. r 4. *. A.

e,J.ACAQA

  • A e

S e

A. e ^J., r.,.r a. A. A.

f r

e

'.N'.L e.,

r. ?

e e

e vu.

L.

o e

y_

V e e

e e

D e v. A, r..'.v^ A.

AA e

A.. V. A. C A. A. A.

A.

A. A a..r A. 0 t.-

s. a A. A. ". A. A. a.

^6 e

e

  • e e

C S. c c.

e e

o.

e e

e V e % s.". A n ^

a AAA

e. e. a.
  • i.t o. r.

A...

A. e. A. ^J. T V.ti^A e

A e

w e. A. *. r 1. A. A.

A f.

C S. C..*

.e

r. ?

e.

e sv4

  • k.

e e

r.

e ve J. A._rA. A. ^V v s. A. A..r a. A. A.

A gaA e

J e V ^ ^. r.1 A. A

^

e

^ A e

A. e J. A..r A. A. r) r rA T..o. o. t.

e.

r. *.

e e

V T V e e

e e

V e. A. A r.a. a. V^

  • V e. t. A. *L. A. A.

a A d e ^. V..r 4 A. r)

^A e

^ A a

e

??

e A. e. A. A r4. A. A.

a A

e e

c...t.S **1 n

e e

e e

e e

A.. A A. a..r a.,.* 0 e v e.,v. r A. A A.

,e A

A. e v% ^ ^ r 4. A. v eAA. v A e A A o

v e. A A. r_ a, A. A e

.P.?

e

r. e.t v. /I e

4 vv_

e v

v s a e

e s

v e V ^ 0 " A ^ $.

V a. A. A. r A. A. V A ^

e A.. A. n. ^ _r a. ^ $.

^ A A

A e. A. o. r. i. A. A.

e.

e A

e

.?

e

e. c..t 7..;

e v cv e

V v

e e

a AAA e

/ e. A. A. r i n a V e V ^. A. r 1 A. V V e V s v _r 4. A. A.

A e ^ ^

A e

A A. e. V. :" T. A, A^A_1A e

a:

.e r_.?

e L..t i. a e

_TVV e

w e

e

/

e e

  • A.

c.:. A 0 ; c r..C,r_ r.N A N f.i r.,0 N *s.?.kllt_e C

i e

E N i..o..r r.."

r e

l

.. m

. _ _..--- _~

PAbE.

p13 4

SITE! LTMERICX UNIT! U1 USER: MART DATE: 01/11/94 10:45 EFFLUENT AND blASTE DISPOSAL REPORT j-d 1

}-

GASEQUS EFFLUENTS FOR RELEASE POINT:

4 HOT MAINTENANCE SHOP CONTINUGUS MODE PATCH MODE NUCLIDES

UNITS :

GUARTER

'0UARTER :

DUARTER :

QUARTER i

1 F r.i e ASer.,

1

2. PARTICULATES (CONTD) 1 iA140 CI
0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000Ef00 CE141
CI
0.000Ef00 0.000Ef00 1 0 000Ef00 : 0.000Ef00 :

e CE144 CI

0.000Ef00 0.000Ef00 : 0 000Ef00 : 0.000Et00
2 u

--_AL._.:.

FERIDF

CI
0.000Et00 : 0.000Et00
  • 0.000Et00 : 0.000Ef0C l
s..u.. C.o. r s

.______.______..__.ee-__......__....._____e-_..s_...___._

1 AJIh CONTI.lJ..

.O....e.%.

2...e. 6. A m6 I

s t

a a

4 i

l H

(

s-w-

ar--

a.

a---twr w

-w t'

w

SITE: LIMERICK PAGE D14 UNIT U1 USER: MARY DATE: 01/11/94 10:38 EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS -- SUMMATION OF ALL RELEASES

! UNITS :

GUARTER GUARTER lEST.

TOTAL:

l 1

1 2

.: ERROR, %

1 l

(

A. FISSION AND ACTIVATION GASES l

1. TOTAL RELEASE CI
0.244Ef02 : 0.392Ef02 0.453Ef02 :

i

2. AVERAGE RELEASE
UCI/SEC: 0.314Ef01 : 0.498Et01 :

RATE FOR PERIOD l 3. PERCENT OF TECHNICAL:

0.000Ef00 : 0.000Ef00 l SPECIFICATION LIMIT :

E. IDDINES

1. TOTAL 10 DINE-131 CI
0.64BE-02 : 0.44?E-02 : 0.453Ef02 :
2. AVERAGE RELEASE UCI/SEC: 0.533E-03 : 0.571E-03 :

RATE FOR PERIOD l 2. PERCENT OF TECHNICAL:

0.000E+00 : 0.000Et00 :

S?ECIFICATION LIMIT :

C. FARTICULATES

1. PARTICULATES WITH CI
0.710E-04 : 0.144E-06 : 0.453Et02 :

HALF-LIVES >B DAYS 6

l 2. AVERAGE RELEASE UCI/SEC: 0.914E-05 : 0.154E-C7 :

RATE FOR PERIOD

3. PERCENT OF TECHNICAL:' %

0.000Ef00 ! 0.000E+00 :

_F< _C r..i F T F A T I O N L _T.W..i

  • l 4. GROSS ALPHA CI
0.000Ef00 : 0.000Ef00 :

RADI0 ACTIVITY D. TRITIUM

1. TOTAL RELEASE CI
0.000Ef00 : 0.000Et00 : 0.4E3Ef0" :

l 2. AVERAGE RELEASE UCI/SEC: 0.000Et00 : 0.000Et00 :

RATE FOR PERIOD

3, PERCENT OF TECHNICAL:
0.000Ef00 0.000E+00 :

SPECIFICATION LIMIT :

ENTER C C 2 TO ERASE SCREEN AND CONTINUE :

C

=

EITE
LIMERICK.

UNIT: U1 PAGE D15 USER: MART DATE: 01/11/94 10:46' EFFLUENT AND WASTE DISPOSAL REPORT

%DPCOM, 11-JAN-1994 10:46:09.14s message from' user SYSTEM 01/11/94 10:46:05 OMUPDT: COMMUNICATIONS IS FAULTY ON RM-11 NUMDER 1 LIQUID EFFLUENTS -- SUMMATION OF ALL RELEASES

! UNITS :

QUARTER QUARTER ;EST.

TOTAL:

1 2

ERROR, A. FISSION AND ACTIVATION PRODUCTS l 1. TOTAL RELEASE (EXCL.:

CI

0.387E-01 : 0.111E-01 : c 428Ef01 :

TRIT., GASES, ALPHA):

l 2. AVERAGE-DILUTED UCI/ML : 0.281E-06 ! 0.708E-07 :

CONC. DURIN0 PERIOD :

l 3. PERCENT OF

0.000Ef00 : 0.000Et00 :

APPLICABLE LIMIT

?. TRITIUM l 1. TOTAL RELEASE CI

0.779Ef01 : 0.452Ef01 : 0.628Ef01 :

l 2. AVERAGE DILUTED UCI/ML : 0.565E-04 : 0.299E-04 :

CONC. DURING PERIOD :

3. PERCENT OF
0.000E+00 : 0.000E+00 :

APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASEE t 1. TOTAL RELEASE CI

0.241E-01 : 0.62SE-01 : 0.629Ef01 :
2. AVERACE. DILUTED
UCI/ML : 0.175E-06 : 0.402E-06 :

~

PAHr.

t. i!*n.T A1E. P7 0. 7 M D
  • l 3. PERCENT OF
0.973E-01 1 0.201Ef00 :

APPLICAPLE LIMIT

?. GROSS ALPHA RADI0 ACTIVITY l 1. TOTAL RELEASE CI

0.000Ef00 0.000Ef00 0.628E401 E. VOLUME UASTE RELEASED ILITERE : 0.152Ef07 : 0.171Et07 : 0.000Et00 :

(PRIOR TO DILUTION)

F. VOLUME DILUTION UATER l LITERS : 0.138Et09 0.156Ef09 : 0.000Ef00 :

UEED DURING PERIOD


~~-------------------


n

PAGE D16 j

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD 01/01/92 TO 06/30/92 A. SOUD WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT IRRADIATED FUEL) l

1. TYPE OF WASTE UNIT 6-MONTH ESTIMATE TOTAL PERIOD ERROR %
a. SPENT RESINS, FILTERS SLUDGES, m(3) 1.94E+ 02 EVAPORATOR BOTTOMS, ETC.

Ci 1.32E+ 02 2.50E + 01 (PROCESS - DEWATERED )

b. COMPRESSIBLE WASTE, m(3) 1.50E+ 01 CONTAMINATED EQUIPMENT, ETC.

Ci 5.83E-01 2.50E + 01 (PROCESS - COMPACTED )

c. IRRADIATED COMPONENTS, m(3) 0.00E+ 00 CONTROL RODS, ETC.

Ci 0.00E+ 00 0.00E + 00

d. OTHER (DESCRIBE) m(3) 4.06E+00 CRD FILTER & TRASH Ci 9.91E+ 01 2.50E + 01 cPORTIONS OF THE WASTE PROCESSED BY OFFSITE VENDORS (OUADREX, SEG)

ACTIVITY IS ESTIMATED.