Forwards line-by-line Descriptions of Changes to Amend 80 to FSAR
ML20065L072
Person / Time
Site: Comanche Peak  
Issue date: 11/30/1990
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
TXX-901031, NUDOCS 9012050193
Download: ML20065L072 (28)


Text

_.

t.

1 i

w

.N.--,

F Log # TXX 901031

.=

File # 10010 r

=

Ref. # 10CFR50.34(b) 7t/ ELECTRIC November 30, 1990 l

William J. Cahill, Jr.

Esrcutive Vke Presdent U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS 50-445 AND 50 446 FSAR AMENDMENT 80 DESCRIPTION-Gentlemen:

Amendment 80 to the CPSES FSAR was transmitted to you under a separate cover letter TXX 901030. dated November 30, 1990. The attachment to this letter provides line by-line descriptions of the the changes in Amendment 80.

FSAR pages which do not have technical changes but are included in the amendment (because they. are the opposite side of the sheet from a page that was changed, because the change shifted the existing material to another page or because only editorial changes were made on these pages) are not discussed in the l

attachment.

As has been the TV Electric practice in the past several amendments, all changes described in the attachment have been evaluated for relative significance (i.e., the group number 1, 2, 3 or 4 following each change justification as discussed in TU Electric TXX-88467 dated June 1,1988).

In addition, all changes applicable to CPSE3 Unit I have been reviewed under the TV Electric 10CFR50.59 process and found not to include any "unreviewed safety questions."

Sincerely, William J. Cahill, Jr.

l-BSD/bsd Attachrart

. c

.Hr. R. D. Hartin. Region IV l

Resident Inspectors, CPSES (3) 9012050193 901130 PDR ADUCK 05000445 h /)Q P

PDC f// (

~

400 North Olive Street LB. 81 Dallas, Texas 75201 l

. [

4tta_chtent to TXX 901031-

~

i 4 Nove:ber 30,11990 Pa'ge 1 of-27 1

j CPSES FSAR AMENDMENr 80 DETAILED DESCRIPTION FSAR Page (A1 amended)

Daterintion

~1A(B) 91

==

Description:==

-(Revision)

Auditing of Quality Assurance Programs Will Comply With Regulatory Guide 1.144, Revision 1 (9/80)

Justification:

The commitment for auditing QA Programs has been re-vised.

Compliance with Regulatory Guide 1.144 Revi-sion 1 (9/80), which endorses ANSI N45.2.12-1977. is now mandatory for Construction and Operation of.CPSES.

Previously, the auditing of the QA Programs "or Con-struction and Operation met the requirements of diffar-ent, earlier draft revisions of the ANSI Standard.

Cc.npliance with the same revision of the ANSI Standard

?

ensures continuity and consistency in the auditing of Construction and Operation phase 0A Programs.

This.

change does not represent a reduction in commitments in the OA Program as described in the FSAR.

Group:'2-FSAR Change Request Number: 90 202 Related SER Section: T17.1:

SSER17 T17.1 SER/SSER ILpact: Yes The SER discusses compliance with the Regulatory Guide 1.144. Revision 0 and the~SER and SSER 17 discuss com-pliance with ANSI N45.2.12. Revision 2, Draft 4.

This-change commits to later revisions of the Regulatory Guide and ANSI Standard, 2,4 63, 68

==

Description:==

(Correction)

Revises design basis groundwater elevations references in FSAR Section 2.4.13.3 to be consistent with the i_

revised text.for FSAR.Section. 2.5.4.10.3 previously l

submitted in Amendment 79 L

Justification:

The Service Water Intake Structure has been reanalyzed

-i I

using a conservative groundwater elevation of 793 feet.

Section 2.5.4.10.3 was revised in Amendment 79 to reflect the revised design _ basis groundwater. elevation.

This clarification-to Section 2.4.13.3 revises the the design basis groundwater elevations values for CPSES to be consistent with other references in the-l' text.

Group: 3

.FSAR. Change Request Number: 90 165 Related SER Section: 2.4.6 SER/SSER Impact: Yes Safety-related structures are conservatively designed for hydrostatic loads with a design basis groundwater elevation of 810', except for the SWIS.

Hydrostatic loads on the SWIS are determined with a design basis groundwater elevation of 793*.

i

e

.t Attach ent to TXX 901031 Ngvenber-30 -1990 Page 2 of.27-FSAR Page I

(11 amended)

Description Table 3-2 1 See Sheet No(s):03 Description (Clarification)

Acd Reference Justification:

Reference to-Table 17A-1 has been added to Note 5 for clarification.

Table 17A-1 contains specifics and ex-ceptions not necessarily contained in FSAR Section 3.2.

Group: 4 FSAR Change Request Number: 90 078.01 Related SER Section: 3.2 SER/SSER Impact: No Table 3.2 3 See Sheet No(s):04

==

Description:==

(Addition)

Add the chlorination system to the Station Service Water. system Justification:

Add the new chlorination system flow diagram to.the list Group: 2 FSAR Change Request Number: 90 085.2 Related SER-Section: 9.2.1:

SSER22 9.2.1 SER/SSER Impact: No Table 3.6B-1 See Sheet No(s):08

==

Description:==

-(Addition)

Addition ofta note to the remarks column'for high energy line 3AF-1-78-2002-3.

Justification:

Remarks column note inadvertently not included for this line-in a previous amendment. The remarks column note is provided to present the basis for not postulating high energy line breaks due to Turbine Driven Pump Auxiliary Feedwater piping and check valve configurat-ion.

Group: 3 FSAR Change Request Number: 90-138.1 Related SER Section: 3.6.2:

SSER6 3.6.2 SER/SSER-Impact: No Table 3.6B-1 See Sheet No(s):54 and 55

==

Description:==

(Correction)

Correct high energy line list by removing six pipe lines in the Steam Generator Blowdown System with maxi-mum operating temperatures and pressures that satisfy-moderate energy piping classification per Standard Re-view Plan 3.'6,1.

Justification:

Deletion of the subject six Steam Generator Blowdown System lines from the High Energy Line List reconciles the FSAR table with as-built plant design basis documentation that substantiates the classification as

L t

AttachIent to TXX 901031 Novc3ber 30, 1990 Page-3 of 27

,FSAR Page (31 amendid)

Description moderate energy piping.

Group: 2 FSAR Change Request Number: 90-138.2 Related SER Section: 3.6.2:

SSER6 3.6.2 SER/SSER Impact: No

. Figure'3.6B-43

==

Description:==

-(Revision)

Revise FSAR figure to reflect three new high energy line breaks postulated at the welded attachments in the l

Steam Generator Blowdown. System (8SB-1 060-1302 5) within the Turbine Building.

Justificat10n:

Of the three new postulated.high energy line breaks postulated in the Steam Generator Blowdown (SGB)-System only one has the potential for affecting a system cre-dited with mitigating the consequences of a'high energy line break (HELB). The effected system is only required to mitigate the envirnomental effects of a break in that system. This new HELB i: located-in the same area as existing postulated HELB's that have been previously l

analyzed for HELB effects, so no unacceptable con-sequences are presented by this new HELB designated 17200/L.'The remaining two new HELB's (i.e. HELB's de-signated 705C/L and 1696C/L) are located outside of' h

areas containing essential components required for safe f.

shutdown or to perform a safety function.

-Group: 3 lt FSAR Change Request Number: 90-138.5 OL Related SER Section: 3,6.2:

SSER6 3.6.2 SER/SSER Impact:-No

. Figure.3.6B-48-1. 48-2 See-Sheet No(s):49,;52 1,152-2 -53, 64 1 and 64-2 1

==

Description:==

(Update)

FSAR Stress Node-Break Point and Restraint Location figures are updated to reflect consolidation of piping stress problem boundaries.

Justification:

Conselidation of-piping stresss problem boundary number

.i designation results in no impact upon CPSES as-built i

plant design.

Group: 4 FSAR Change Request Number: 90-138.3 Related SER Section: 3.6.2:

SSER6 3.6.2

'SER/SSER Impact: No Figure 3.6B-68-1, 68-2 See Sheet No(s):74

==

Description:==

(Update)

FSAR Stress-Node Break Point and Restraint Location figures are updated to reflect consolidation of piping stress problem boundaries.

Justification:

Consolidation of piping stresss problem boundary number

m-I 1')_

t Attach 2ent to TXX 901031

Nave:ber :30, 1990 Page 4 of 27 FSAR Page

_(ar amended)

Description designation results in no impact upon CPSES as built plant design.

Group: 4 FSAR Change Request Number: 90-138.4 Related'SER Section: 3.6.2:

SSER6 3.6.2 SER/SSER Impact: No Table 3.9N-10 See Sheet No(s):02

==

Description:==

(Correction)

Corrections are made to the'NSSS Active Valve List to correct 6 typographical error in designating the valve.

i

. number 8145 as 8115. the valve's active function to provide a RCS pressure boundary and the valve type is a globe valve consistent with FSAR Table 9.3 9 sheet 25.

Justification:

The correct valve tag number, type and active function are reflected by CPSES design basis documents'and con-

-sistent with FSAR Figure.9.3-10 sheet 2 and Table.9.3-9 sheet 25.

Group: 4 FSAR Change Request Number: 90 144-Related SER Section: 3.9.3:

SSER22 3.10.2 SER/SSER Impact: No 4.2-6 See Page No(s):212-134

==

Description:==

(Editorial)

Adds the response'to Question 212.70 to the text of Section 4.2.1.3.

(The text of the response has been edited for incorporation.)

Justification:

This change is made to ready the Q & R section for de-letion when the USAR-is prepared.

Group: 4 FSAR Change Request Number: 90-180.2 Related SER Section: 44.2.1 1

SER/SSER Impact: No j

6.3-10 See Page No(s):

212-206. Table:17A-1 (sh 7)

==

Description:==

(Editorial) p Changes the description of the head rating for the SI pumps from high head to intermediate head.

Justification:

This change is made to assist in readying the 0&R section for deletion when the USAR is prepared.

In ad-dition, it brings-the classification into conformance with what is used in other project documents.

This is a wording change only; no design change is involved.

Group: 4 FSAR Change Request Number: 90-182.2 Related SER Section: 6.3.2 SER/SSER Impact: No

i i

l AttaczenttolTXX-901031 Nave:ber 30,.1990 Page 5 of'27 FSAR Page (n Angsled)

Description 9.1 24 See Page No(s):010 18

==

Description:==

(Update)

Revise the section to incorporate seismic classifi-cation of the spent fuel pool cooling and cleanup system.

Justification:

This change is made to incorporate the response to 0&R 010.11 into revised section 9.1.3.2.1, which delineates E

the seismic classification boundary of the spent fuel pool cooling and cleanup system.

Group: 3 FSAR Change Request Number: 90 195.1 Related SER Section: 9.1.3; SSER22 9.1.3 SER/SSER Impact: No i

9.2-4

==

Description:==

(Addition)

Add the chlorination system to Station Service Water System Justification:

Add the new chlorination' system to the plant which will inject sodium hypochlorite and sodium bromide for the control of organic fouling of the Station Sevice Water system.

Group: 2 FSAR Change Request Number: 90 085.1 Related SER Section: 9.2.1; SSER22 9.2.1 SER/SSER Impact: No 9.2-28

==

Description:==

(Editorial).

Add the following to complete the sentence:

" preventive maintenance can be_ conducted as necessary L without: interruption of-the CCWS operation" Justification:

Complete the sentence for the test and inspection lsection of the CCWS, which was inadvertently deleted due to the repagination error in FSAR Amendment 78.

Group:.4 FSAR Change Request Number: 90-171

'Related SER Section: 9.2.2; SSER22 9.2.2 4

SER/SSER Impact: No i

Figure 9.2-1 See Sheet No(s):01 and 04

==

Description:==

(Addition) l' Add the new chlorination system to the Station Service L

Water system j

Justification:

Add the chlorination system to the plant which will L

inject the Sodium Hypochlorite and Sodium Bromide for the control of organic fouling in the Station Service L

Water system.

L Group: 3 i

FSAR Change Request Number: 90-085.3

L' 7

s' At' tach;ent to TXX 901031 Nove2ber 30, 1990 Page 6 of 27 FSAR Page (11 amended)

Description Related SER Section: 9 P.1:

SSER22 9.2.1 SER/SSER Impact: No Figure 9.2 4A See Sheet No(s):02

==

Description:==

(Addition)

Add double isolation to the cross-tie between the degasified water clear well and the R. O. system clean-ing tank.

Justification:

Double isolation valves capacity is added to the cross-tie to meet the separation criteria for Potable Water system to a contamination source which also meets the requirement of the Texas Department of Health.

Group: 3 FSAR Change Request Number: 90-101 Related-SER Section: 9.2.4; SSER22 9.2.4 SER/SSER Impact: No 9.3 2

==

Description:==

(Addit:on)

Add the breathing air requirement to the Instrument Air system.

Justification:

Addition of breathing air requirement to the Instrument-Air system is within the design limit of the Instrument

. Air System, and willinot challange the plant's ability to power operation or. safely shutdown with loss of air.

Group: 3 FSAR Change Request Number: 90-193 Related SER Section: 9.3.1; SSER22 9.3.1 SER/SSER Impact: No-Figure 9.3 4 See Sheet No(s):01. 02, 03, and 03A

==

Description:==

(Correction)

To show the valve position on sample syem flow-diagram and delete sample cylinder tag numbers Justification:

To indicate valve position used for sample system operation, to show equipment as installed and to allow-the use of and of the sample' cylinders.for all,of the samples.

Group: 3 FSAR Change Request Number: 90-155.1 Related SER Section: 9.3.2:

SSER22 9.3.2 SER/SSER Impact: No 9.4E-2 See Page No(s):010-23

==

Description:==

(Update)

Add design and operational requirement of the plant chi lied water system, which incorporates Q&R 010.16 Justification:

Incorporate Q&R 010.16 into revised section 9.4E, which include the design and operational requirements of the

- v'*

.s Attachrent'to TXXa901031

Nqve2ber 30.'1990 Page 7 of 27-FSAR Page

.(Al Amendid)

Pescrintion plant chilled water system in the event of an seismic event.

Group: 3 FSAR Change Request Number: 90 207.1 Related SER Section: 9.4; SSER22 9.4 SER/SSER Impact: No Figure 9.5-61

'See Sheet No(s):01

==

Description:==

(Addition)

Add fire suppression for Material Staging Building.

Justification:

The plant Fire Irotection Water Supply System was s

modified to provide a water source for the fire suppression systems associated with the new Material i

Staging Building.

This modification does not-affect the capability of supplying fire protection water to safety related plant areas.

Group: 2 FSAR Change Request Number: 90-094 Related SSER Section: SSER12 9.5.1 SER/SSER Impact: No Figure _10.3 1 See Sheet No(s):04 Description (Addition) l Addition of Equipment Tag Numbers for Feedwater Pump L

Turbine.Stop and Control Valves l'

Justification:

Tag' numbers on major. system equipment aids in identifi-cation by the operator.

Group: 4 FSAR Change Request Number: 90 194 SER/SSER-Impact:_ No t

I Figure-10.4-8 See Sheet No(s):01

==

Description:==

(Correction)

Remove' Check Valve 100-0440 and Relief Valve 1AF-0251 Justification:

f Check valve 100-0440 and relief valve 1AF-0251 were.

L added in an earlier amendment to pro"ide overpressure-h protection for a portion of the Auxiliary Feedwater System.

Leakage though normally closed valve 100 0195 l

was limited by check valve 1C0-0440 and the system was' l

protected by relief valve 1AF-0251.

Amenbient ' 78 incorporated an alternate means of protecticn.

If valve 100-0196 is normally open, it serves as a path for the leakage through 100-0195, The alternate datign was prepared before valves 100-0440 and 1AF-0251 were physically added. This amendment is consistent with current as-built design.

l Group: 3 FSAR Change Request Number: 90-038 L

SER/SSER Impact: No 1-

-m

-At' tach;ent'to TXX 901031

. Nave 2ber 30, 1990 Page 8 of 27 FSAR Page (Al~Atinded)

P_,jeriotion Figure 10.4-14 See Sheet No(s):01

==

Description:==

(Correction)

Change normal position of valve 1HD 0888 frop normally closed to normally open and add valve 1HD 0889 to match

-the as-built configuration of the Heater Drains System.

Justification:

The Secondary Plant Sampling System is designed to con-tinuously measure parameters in samples from the secon-dary cycle.

The sample line valves, which include 1HD-0888, must be normally open to provide flow.

1HD 0889 is provided for non continuous sampling of other parameters and is normally closed.

Group: 3 FSAR Change Request Number: 90 147 SER/SSER Impact: No Figure 10.4-16 See Sheet No(s):01 and 04

==

Description:==

(Correction)

Correct the Auxiliary Steam System Configuration to i

Match the As Built Design Justification:

The changes consist of:

J 1.

Addition of blowdown valves for the Auxilary Steam l>

Header Drip Pot-traps. (Sheet 1) 2.

Addition of vent and drain' valves and relief-valve on the Economizer section of the Auxiliary Boiler.

(Sheet 4) 3.

Clarification of instrument line configuration on the Auxiliary: Boiler / Steam Drum.

(Sheet 4)-

4.

. Addition of valves and changes to piping configura-tion on the Auxiliary Boiler burner control system.

(Sheet 4)

These changes are all minor. The operation of the Aux-iliary Steam System is not affected by any of these changes.

Group:-3 FSAR Change Request Number: 90-142 SER/SSER-Impact: No Table 12.2-26 See Sheet No(s):03

==

Description:==

(Correction)

Correct the subtitle on table 12.2-26 from NORMAL OPERATIONS to SHVTDOWN and REFUELING.

l Justification:

The isotope inventory listed on the table reflect the airborne concentrations of materials expected during shutdown and refueling operations.

This restores the table to its proper title.

Group: 4

1

.'Aftach ent to TXX 901031

.Nove:ber 30, 1990 Page 9 of 27 j

.FSAR Page (Al Amended)

Description l

FSAR Change Request Number: 90 170 Related SSER Section: SSER22 12.2 SER/SSER Impact: No 13.1-8, 9

==

Description:==

(Update) 1 Update to reflect the current CPSES organizational structure and management incumbents.

Justification:

Update the CPSES organization to support Unit 1 operation and Unit 2-construction efforts, as well as, to accomodate personnel attrition.

Group: 4 FSAR Change Request Number: 90-157 Related SSER Section: SSER22 13.1 SER/SSER Impact: No 13.1 A 1 -

See Page No(s):15 and 16

==

Description:==

(Update)

Update to reflect the current CPSES organizational-structure and management incumbents.

Justification:

Update CPSES personnel-resumes to-accomodate personnel attrition or reassignments.

Group: 4 FSAR Change Request Number: 90 157 L

Related SSER Section: SSER22 13.1 SER/SSER Impact: No Table 14.2-3' See Sheet No(s):29-

-Description: (Revision)

Revises T14.2 3, Sheet 29, test prequisite #4 to delete the requirement' that all RCCA's be ' inserted when the reactor is shutdown prior to initial criticality.

Justification:

The basis for the prerequisiste that "the reactor is shutdown prior to initial criticality" is to ensure the reactor leakage is within specification prior to 5

increasing the radioactive content of the coolant by achieving initial criticality.

The requi:ement for:the reactor to be shutdown and the requirement for testing-prior to criticality is unchanged, The posit 1cn of the RCCAs has no bearing to the validity of the'tes'.

result!.

The postion of the RCCA's are controlied by other initial startup procedures and are not necessarily fully inserted.

This complies with the L

Regulatory Guide 1.68 requirement that the sequence of startup tests be ordered so that safety is not dependent on untested structures, systems or compontents.

This change to the inital startup program was previously transmitted to the NRC in TXX-90155 dated April 20, 1990.

Group: 3 l.

l:

a Atla'ch;ent to TXX 901031

'Nove;ber 30, 1990 q

Page 10 of 27 FSAR Page.

(AA RRtadid)

Eticription

~

FSAR Change Request Number: 90-160 Related SER Section: 14.0 SER/SSER Impact: No 15.1-21 See Page No(s):032 31, 10.2-17

==

Description:==

(Editorial)

Adds a portion of the response to Question 032.30 to_

the text in Section 15.1.5.1.

Justification:

This change is made to assist in readying the 0 & R section for deletion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 179.2 Related SER Section: 15.3.5 SER/SSER Impact: No 15.2 4 See Page No(s):212-199

==

Description:==

(Editorial)

Adds a portion'of the response to Question 212.127 to the text of Section 15.2.2.1.

Justification:

This change is made to assist in readying the 0 & R section for deletion when the USAR is prepared.

Group: 4 L

FSAR Change Request Number: 90-187.2 Related SER Section: 15.2.2 SER/SSER Impact: No-15'.2-14

.See Page No(s):212-136

==

Description:==

(Editorial)

Adds the response to Question 212.72 to the text of' Section 15.2.5.

Justification:

This. change is made to ready the 0 &- R section for de-letion when the USAR is prepared..(The text of the response has been edited for incorporation.)

Group: 4 FSAR' Change Request Number: 90-175.2 Related SER Section: 15.2.2 SER/SSER Impact: No 15.2 See'Page No(s):212-199

==

Description:==

(Update)-

Changes the identification of Reference 1.

Justification:

1 This change is made to make the reference cited here i

I consistent with that identified subsequently in the response to Question 212.127.

(In that response. Rev.

1 of WCAP-7769 was cited, rather than the original version.)

Group: 3 FSAR Change Request Number: 90-187.3 L

Attachasnt to TXX 901031 November 30, 1990 Page 11 of 27 FSAR Page

- ( Al AMDAtd)

Pitcription Related SER Section: 15.2.2 SER/SSER 1mpact: No 15.3 7 See Fage No(s):212-140 Descriptions (Editorial)

Adds the response to Our

.on 212.76 to the text of Section 15.3.2.1.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 176.2 Related SER Section: 15.3 SER/SSER 1mpact: No 15.4 12 See Page No(s):232 9 Description (Editorial)

Adds a portion of the response to Question 232.9 to the text of Section 15.4.2.2.

Justification:

This change is made to assist in readying the 0 & R section for deletion when the USAR is prepared.

Group 4 FSAR Change Request Number: 90 186.2 Related SER Section: 15.3.2 SER/SSER 1mpact: No 16.6 1, 2 See Page No(s):212 143 Description (Editorial)

Incorporates into FSAR sectidn 15.6.1.1 the substantive portions of the response to. Question 212.79.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

The first sentence of the response is deleted since designating the acci-dent es " hypothetical" is not relevant to the response.

The second sentence is also deleted, except for the specific valve relieving capacities, since the other information is already included in the text of Section 15.6.1.1.

Group: 4 FSAR Change Request Number: 90 177.2 Related SER Section: 15.2.2 SER/SSER 1mpact: No 17.1 10

==

Description:==

(Revision)

Remove Reference to ANSI N45.2.12. Draft 3. Rev. O and Reference FSAR Appendices lA(H) and 1A(B).

Justification:

The commitment to R.G. 1.144 which is located in FSAR Appendices 1A(N) and 1A(B) is being revised for compli-ance with Revision 1 (9/80).

Revision 1 endorses ANSI

Attachment te TXX 901031 Ngvember 30, 1990 Page 12 of 27 FSAR Page (11 Amended)

Description N45.2.12 1977 which is a later revision than Draft 3 Rev. O.

This section is being revised to remove direct reference to the committed revision and refer to 1A(N) and 1A(B) where the committed revision is directly stated. This change does not represent a reduction in commitments in the QA Program as described in the FSAR.

Group: 2 FSAR Change Request Number: 90 202.1 Related SEC Section: T17.1 SSER17 T17.1 SER/SSER 16. pact: Yes The SER discusses compliance with Regulatory Guide 1.144. Revision 0 and the SER and SSER 17 discuss com-p11ance with ANSI N45.2.12 Revision 2, Draft 4.

The change to 1A(N) and 1A(B) commits to later revisions of the Regulatory Guide and ANSI Standard.

Table 17A 1 See Sheet No(s):07

==

Description:==

(Correction)

Correct Safety Class Applicable Code, Code Class, Seismic Category, and Quality Assurance notes for the Safety Injection System components Justification:

The valve isolation tanks, expansion joints and piping were declassified to NNS in a previous amendment of the FSAR, as shown on Figure 6.3 1.

Table 17A 1 is being changed to agree.

Note 57 has been added to indicate that seismic analysis is performed for small bore piping and supports.

Groupt 4 FSAR Change Request Number: 90 078.02 SER/SSER Impact: No Table 17A 1 See Sheet No(s):07 and also see 212 206, 6.3 10

==

Description:==

_ (Editorial)

Changes the description of the head rating for the SI pumps from high head to intermediate head.

Justification:

This change is made to assist in readying the Q&R section for deletion when the USAR is prepared.

in ad-dition it brings the classification into conformance with what it used in other project documents. This is a wording change only: no design change is involved.

l Group: 4 l

FSAR Change Request Number: 90 182.3 Related SER Section: 6.3.2 SER/SSER 3mpact: No Table 17A-1 See Sheet Ho(s):09

==

Description:==

(Clarification)

Revise the seismic Category and Quality Assurance Notes for the Boron Recycle System Evaporator Package components

E Attachment tn TXX 901031 November 30, 1990 Page 13 of 27 FSAR Page zt

-(n matDdfj)

Dg}crietion Jussification:

J The Distillate water side and Distillate side of the Evapo"ator condenser and the Gas side of the Vent Con-denser have been changed to Seismic Category NONE.

Only their mounting, anchors and supports are Seismic Category !! and subject to the Note D Operations OA Program.

Generic Justification:

The purpose of Table 17A 1 is to list items with quali-ty assurance (QA) requirements. Currently Table 17A 1 may list items as Seismic Category !! if any portion of the item meets the criteria of FSAR Section 3.2.1.2.

However, without the critical attributes specified. it is not readily apparent for which portions of the item t

OA is required.

Table 17A 1 is being changed to more clearly specify the critical attributes of Seismic Category !! items which are subject to 0A requirements.

By listing the critical attributes, the Table more accurately reflects how the seismic qualification is maintained.

In most cases, the OA requirements are only applicable to an-chors and supports.

For items where subcomponents or mountings are the only portions that have Seismic Cate-3 -

s;ry 11 QA requirements, " Seismic Category II" has been replaced by "NONE" and the Seismic Category 11 attri-butes have been listed in the Notes at the end of Table 17A 1.

Since this change only clarifies which attributes have 0A requirements without changing the overall seismic qualification of the item, it does not represent a re-duction if the commitments of the QA Program.

Group: 4 FSAR Change Request Number: 90 078.03 SER/SSER Impact: No Table 17A 3 See Sheet No(s):10 and 11'

==

Description:==

(Correction)

Correct the Safety Class, Applicable Code, Code Class, Seismic Category, and Quality Assurance notes for the Containment Spray System Components Justification:

The valve isolation tanks, expansion joints and piping were declascified to NHS in a previous amendment of the FSAR, as shown on Figure 6.2.21.

Table 17A 1 has been chenged to agree.

Note 57 has been added to indicate that seismic analysis is performed for small bore piping and supports.

Group: 4 FSAR Change Request Number: 90-078.04 SER/SSER Impact: No

, <=

Attachment to TXX*901031 Nove:ber 30, 1990 Page 14 of 27 FSAR Page (31 metaded)

Description Table 17A 1 See Sheet No(s):11 and 12 Descriptions (Clarification)

Clarify the Seismic Category and Quality Assurance Notes for the Combustible Gas Control System Justification:

The exhaust fans and supply blowers for the Hydrogen Purge System have been changed to Seismic Category NONE Only their mountings, anchors, structural steel and are Seismic Category !! per Note 70 and are subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A*1, Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.05 SER/SSER Impact: No Table 17A 1 See Sheet No(s):11 and 12 Description (Clarification)

Clarify Seismic Category of Dampers in the Combustible Gas Control Systems Justification:

Added Note 71 to clarify that NVAC Dampers are Seismic Category NONE.

Only their mounting and supports per Note 71 are Seismic Category !! and are subject to the Note B Operations 0A Program.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.13 SER/SSER 1mpact: No Table 17A 1 See Sheet No(s):12

==

Description:==

(Clarification)

Clarify the Applicability of Quality Assurance Requirements for Component Cooling Water System Justification:

The valves for the Radiation Monitor Sainple Lines have been removed from the Table.

The valves are Seismic Category NONE and have no 0A requirements.

Seismic Category 11 applies only to the piping.

See the Generic Justification for Table 17A 1. Sheet 9.

Group: 4

)

FSAR Change Request Number: 90 078.06 SER/SSER Impact: No l

Table 17A 1 See Sheet No(s):13 L

==

Description:==

(Clarification)

Clarify the Applicable, Code Class. Seismic Category, and Quality Assurance notes for the Service Water Sys-i tem Screen Wash Pumps Justification:

The Screen Wash Pumps have been changed to Seismic Cat-egory NONE.

Only their mountings, anchors and supports are Seismic Category 11 per Note 72 and subject to the

a ei Attachment to TXX 901031 Nqvember 30, 1990 Page 15 of 27 FSAR Page (in.eemdad)

De cripilen Note B Operations OA Program.

See the Generic Justificati;n for Table 17A 1, Sheet 9.

i Group: 4 FSAR Change Request Number: 90 078.07 SER/SSER Impact: No 1

Table 17A 1 See Sheet No(s):16 Descriptions (Clarification)

Clarify Table 17A 1 for the Systems / Components Listed for the Diesel Generator Fuel Oil Storage & Transfer System Justification:

A separate line item for Class 5 piping and supports has been added for consistency with other system lists.

The Seismic Category has been changed from !! to

!!/NONE to reflect that not all Class 5 piping and supports are required to be seismic category !!.

Code Class "NNS." an editorial error, has been removed.

See the Generic Justification for Table 17A 1, Sheet 9.

Group 4 FSAR Change Request Number: 90 078.08 SER/SSER Impact: No Table 17A 1 See Sheet Ho(s):17 Description (Clarification)

Clarify Safety Class, Code Class, Seismic Category, and Quality Assurance notes for Diesel Generator Starting Air System components Justifications-The compressors, af ter coolers and air dryers have been changed to Seismic Category NONE.

Only the mounting, anchors-and supports are Seismic Category !! per Note 72 and are subject to the Note B Operations OA Program.

Class 5 piping and supports has been 6dded to the com-ponent list for consistency with similar systems.

See the Generic Justification for Table 17A 1. Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.09 Related SSER Section: SSER22 9.5.6 SER/SSER 1mpact: Yes The NRC states that "...any classification is accept-able provided failure of these components will not I

affect safety related components.

The components in question are seismic category !! which the staff finds acceptable.

Seismic testing... is not required."

Table 17A-1 See Sheet No(s):19 Descriptien (Clarification)

Clarify Seismic Category and Quality Assurance notes for Diesel Generator Combustion Air Intake & Exhaust Syste.n components Justification:

l

Attach:ent to TXX 901031 Novemb:r 30, 1990 Page 16 of 27 FSAR Page (u amendtd)

Dticription The Exhaust Relief Valve and the Flexible Connectors do not have seismic requirements.

The anchor bolts, r,tructural steel and mounting of the flexible connec-tors are subject to the Operations OA Program per Note 70.

Cod Class NNS,

an editorial error, has been re-moved.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.10 Related SSER Section: SSER22 9.5.8 SER/SSER impact: Yes The NRC questioned the seismic !! categorization of flexible connectors, exhaust relief valve and exhaust piping on the roof. These components were determined to be functional during and af ter the seismic event.

The NRC, therefore, accepted seismic category II.

Table 17A-1 See Sheet No(s):20 through 23 Descriptions (Clarification)

Clarify Seismic Category and Quality Assurance Notes for Liquid Waste Processing System Justification:

The Waste Holdup Tank, Waste Evaporator Feed Pump, Waste Evaporator feed Filter. Waste Evaporator Package Feed Preheater, Gas Stripper, Submerged Tube Evapora-tor Evaporator Condenser (Distillate Side), Distillate Cooler (Distillate Side). Absorption Tower, Vent Con-denser (Gas Side), Distillate Pump, Concentrate Pump, Piping and Valves for feed Distillate, Concentrate and Vent, and Floor Drain Waste Evaporator Package Evapora-1 l

tor Condenser (Distillate Side), Distillate Condenser i

(Distillate Side), and Vent Condenser (Gas Side) have l

been changed to Seismic Category NONE.

Only the mount-ings, anchors and supports are Seismic Category 11 per Note 72 and are subject to the Note B Operations OA i

l_

Program, j

See the Generic Justification 1st Table 17A 1, Sheet 9.

Group: 4 i

l FSAR Change Request Number: 90 078.11 SER/SSER 1mpact: No i

L i

Table 17A 1 See Sheet No(s):25

==

Description:==

(Clarification)

Clarify Seismic Category and Quality Assurance Notes for Gaseous Waste Processing System Justification:

l-The Gas Decay Tanks (numbers 9 & 10) have been changed I

to Seismic Category NONE.

Only the mountings, anchors and supports are Seismic Category 11 per Note 72 and are subject to the Note B Operations OA Program.

f See the Generic Justification for Table 17A-1. Sheet 9.

i Group: 4 1;

Attachment to TXX 901031 1

Nqvember 30, 1990 Page 17 of 27 FSAR Page (11 angadtd)

Description FSAR Change Kequest Number: 90 078.12 SER/SSER Impact: No Table 17A 1 See Sheet No(s):26 and 27

==

Description:==

(Clarification)

Clarify the Seismic Category and Quality Assur6 ace Notes for Dampers in the Containment Ventilation System Justification:

Added Note 71 to clarify that HVAC dampers are Seismic Category NONE. Only their mountings, structural steel ond anchors are Seismic Category !! per Note 70 and are subject to the Note B Operations OA Program.

Added Note 23 to Containment Preaccess Filtration Unit for specification of critical parts.

The term " dampers and supports" has been changed to

" dampers" because the dampers are inside the ductwork.

"Ductwork and supports" are a separate entry in the Table.

See the Generic Justification for Table 17A-1. Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.14 SER/SSER Impact: No Table 17A 1 See Sheet No(s):29 and 31 Descript4 9n (Clarification)

Clar4 4 'he Seismic Category and Quality Assurance Notes f e the Safeguard Building HVAC System and Uncontrolled Acces Area Ventilation System Justification:

Supply Units / Fans have been changed to Seismic Category NONE.

Only their mountings, structural steel and an-l chors are Seismic Category 11 per Note 70 and are sub-5 ject to the Note B Operations OA Program.

See the Generic-Justification for Table 17A-1. Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.15 SER/SSER Impact: No Table 17A 1 See Sheet No(s):29,30,31 and 32

==

Description:==

(Clarification)

Clarify the Seismic Category and Quality Assurance Notes for Dampers in the Sefeguard Building HVAC Sys-tem, Fuel Building Ventilation System, Uncontrolled Ac-cess Area Ventilation System. Primary Plant Ventilation and Auxiliary Building Ventilation System.

Justification:

Added Note 71 to c9arify that HVAC dampers are Seismic Category N(iNE. Only their mountings, structural steel and anchors are Seismic Category 11 per Note 70 and are subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A 1. Sheet 9.

At'tachment to TXX 901031 Nqvember 30, 1990 Page 18 of 27 FSAR Page (Ali Atendtd)

Dgseriotien Group: 4 FSAR Change Request Number: 90 078.16 SER/SSER Impact: No Table 17A 1 See Sheet No(s):32 Description (Correction)

Remove Redundant Entries for Dampers and Ductwork in the Auxiliary Building HVAC System Justification:

The separate line items for dampers /ductwork and sup-ports for the Boron Injection Surge Tank Room Emergency System were removed.

The dampers /ductwork and supports are enveloped by the generic safety class 3 items.

4 Group: 4 FSAR Change Request Number: 90 078.17 SER/SSER Impact: No Table 17A 1 See Sheet No(s):37 Descriptions (Clarification)

Clarify the Seismic Category and Remarks for the Roll-Away Missile Shield t

Justification:

The non-critical parts of the roll away missile shield have been changed to Seismic Category NONE.

Only the mountings, anchors and structural steel are Seismic Category !! per Note 70 and are subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A 1. Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.18 SER/SSER 1mpact: No-Table 17A-1 See Sheet No(s):39 Descriptions (Clarification)

Clarify the Remarks for Removable Precast Block Walls and Gypsum Walls Justification:

Added Note 70 to clarify that the mountings, anchors and structural steel of removable precast block walls and gypsum walls are subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 FSAR Change Request Number: 90-078.19 SER/SSER 1mpact: No Table 17A 1 See Sheet No(s):41

==

Description:==

(Clarification)

Clarify Wire and Cable Raceway System Applicability and the Seismic Category and Quality Assurance Notes for Conduit (Not Containing Class 1E Wires and Cables)

Justification:

r At' tach::nt to TXX 901031 Navenber 30, 1990 Page 19 of 27 FSAR Page (Al amended)

Etteriotion The title of the section has been changed to reflect applicability to Seismic Category I buildings. The Conduit (not containing Class 1E wires or cables) has been changed to Seismic Category NONE.

Only the con-duit supports are Seismic Category 11 per Note 67 and are subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.21 SER/SSER 1mpact: No Table 17A-1 See Sheet No(s):42 and 43

^

Description (Correction)

Add ANSI Safety Classification for Radiation Monitoring System Monitors Justification:

The ANSI Safety Classification has been added for the Containment Air Monitors, Plant Vent Stack Monitors, Component Cooling Water Monitors, Ventilation Duct Mon-itors and Liquid Waste Effluent Monitors. The Safety Class was previously listed as "N/A".

The addition is consistent with the system flow diagrams and the design basis documents.

Group: 4 L

FSAR Change Request Number: 90 154 SER/SSER Impact: No Table 17A 1 See Sheet No(s):42 and 43

==

Description:==

(Clarification)

Clarify Seismic Category and Quality Assurance Notes for the Radiation Monitoring System Justification:

L The Main Steam Line Monitors, Component Cooling Water Monitors and Waste Gas Monitors have been changed to Seismic Category NONE.

Only the critical parts per Notes 73 and 74 are Seismic Category 11 and are subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 l

FSAR Change Request Number: 90 078.22 l

Related SER Section: 11.3 SER/SSER 1mpact: No Table 17A 1 See Sheet No(s):43 and 44 l

==

Description:==

(Cl ari fi cati or,)

?

Clarify Seismic Catego'y and Quality Assurance notes l-for Fire Protection S,istem Components Justification:

l Fire Suppression Systems, Portable Extinguishers, Fire Rated Coating Systems, Detection Systems, Fire Doors, Fire Dampers and Fire Rated Barriers have been changed to Seismic Category NONE.

Only mountings, anchors and

o At'tachment to TXX 901031 November 30, 1990 Page 20 of 27 FSAR Page (al spended)

Q9*_riDtion supports are Seismic Category !! per Note 72 and are subject to the Note B Operations OA Program.

Fire Ex-tinguisher Brackets have been added as a separate item with the same Seismic and 0A requirements.

Valves have been removed from the RCP Lube Oil Collection System as they are Seismic Category NONE and have no OA require-ments.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 FSAR Change Request Number: 90 078.23 SER/SSER 1mpact: No Table 17A 1 See Sheet No(s):44

==

Description:==

(Correction)

Correct Seismic Category for Class 5 Piping and Supports in the Hydrogen System Justification:

All Class 6 piping and supports in the Hydrogen System are Seismic Category !! for compliance with BTP CMEB 9.5 1 as previously committed in SSER 12, page 9 23.

Seismic Category NONE has been removed for consistency.

Group 3 FSAR Change Request Number: 90 078.24 Related SSER Section: SSER12 9.5.1.4 SER/SSER Impact: No Table 17A 1 See Sheet No(s):47 Description (Clarification)

Clarify Seismic Category and Quality Assurance Notes for Instrumentation and Controls Justification:

1 Control Room Benchboards, Vertical Panels or Hot Shut-down Panel Mounted Equipment Classified as Non 1E has been changed to Seismic Category NONE.

Note 70 has been added to clarify that the anchor bolts, structural Steel and/or mounting for these components are subject to the Operations 0A Program.

See the Generic Justification for Table 17A 1 Sheet 9.

Group: 4 l

FSAR Change Request Number: 90 078.26 SER/SSER 1mpact: No Table 17A 1 See Sheet No(s):47

==

Description:==

(Clarification)

Clarify Seismic Category for Tornado Venting Components Justification:

Dampers and Blowout Panels have been changed from Seis-mic Category 11 to II/NONE because not all are Seismic Category 11.

In addition, Note 76 clarifies that only Control Room blowout panels are Seismic Category 11 and subject to the Note B Operations OA Program.

See the Generic Justification for Table 17A 1. Sheet 9.

At'tachment to TXX 901031 Nmwember 30, 1990 Page 21 of 27 FSAR Page (11 AMadtd)

Descriptio3 Group: 4 FSAR Change Request Number: 90 078.27 Related SER Section: 3.3.2 SER/SSER 1mpact: No Table 17A 1 See Sheet No(s):48 Description (Correction)

Correct Applicable Code and Code Class for Potable and Sanitary Water System Justification:

The Safet> Classification of the Domestic Water Storage T:r.k was previously changed to NHS.

The Applicable Code and Code Class have been changed to be consistent with FSAR Table 3.2 1.

Note 23 has been added to clar-ify the applicability of the Note B Operations OA Pro-gram.

Group: 4 FSAR Change Request Number: 90 078.28 SER/SSER Impact: No Table 17A 1 See Sheet No(s):50

==

Description:==

(Clarification)

Correct Table 17A 1 Note 9 Justification:

Clarify that the Fuel Handling Bridge Crane parts are non safety related for consistency with Table 17A 1 and clarify that " applicable" quality assurance require-ments of 10CFR50. Appendix B are met.

The Fuel Handling Bridge Crane is provided as safety-related because some plants have requirements for Crane operation to preclude / mitigate the effects of a fuel handling accident.

Comanche Peak is not one of those plants.

Group: 4 FSAR Change Request Number: 90 078.29 SER/SSER 1mpact: No l

Table 17A-1 See Sheet No(s):54

==

Description:==

(Revision)

Revise Table 17A-1 Note 44 Justification:

Note 44 has been changed to remove the non existent combination of Seismic Category NONE Piping with Seis-mic 11 Supports.

An evaluation of all class 5 piping in category I buildings was performed.- Seismic failure was not credible, so none of the supports were required h

to be Seismic Category II.

Hence, the combination of l

Seismic Category II supports on Seismic Category NONE l

piping does not exist.

Group: 3 FSAR Change Request Number: 90 078.37 SER/SSER Impact: No

e.

At'tachzent to TXX 901031 Nov0;ber 30, 1990 Page 22 of 27 FSAR Page (11 amended)

Description Table 17 A 1 See Sheet No(s):55 Description (Revision)

Revise Table 17A 1 Note 54 Justification:

Updated Note 54 to reflect removal of Fire Dampers from ventilation flow diagrams and to specify the thermal link as the Seismic Category Il part.

See the Generic Justification for Table 17A 1, Sheet 9.

Group: 4 FSAR Change Request Number: 90-078.32 SER/SSER Impact: No Table 17A 1 See Sheet No(s):56 Description (Clarification)

Clarify Table 17A 1 Note 64 Justification:

Changed the wording to more clearly convey the intent of the Note.

The intent is not that the insulation may be removed.

The intent is that the insulation need not be non crushable, i.e., other insulation is acceptable.

Grc'8D: 4 FSAR Change Request Number: 90-078.33 SER/SSER impact: No Table 17A 1 See Sheet No(s):57 Description (Clarification)

Clarify Table 17A 1 Note 67 Justification:

Note 67 has been changed to remove the definition of seismic categories. Seismic categories are defined in FSAR Chapter 3.2.

Specific seismic and quality assur-ance requirements for conduit and conduit supports has been added.

Group: 4 FSAR Change Request Number: 90-078.34 SER/SSER Impact: No Tr.ble 17A-1 See Sheet No(s):57 I

==

Description:==

(Clarification)

Add Notes 70 through 76 to Table 17A 1 Justification:

Notes 70 through 74 and 76 have been added to specify the applicability of Seismic Category 11 and the Note B Operations OA Program for the structures, systems and l

components in Table 17A 1.

A justification for each use of these new notes has been provided as part of the description for each time the new notes have been used for items in Table 17A-1.

In addition _, Note 75 has been added to specify the operability requirements for the Diesel Generator Exhaust Relief Valve.

See the Generic Justification for Table 17A 1. Sheet 9.

e.

i At'tachment to TXX 901031 Nwember 30, 1990 i

Page 23 of 27 j

FSAR Page (31 amended)

Description Group: 4 FSAR Change Request Number: 90 078.35 SER/SSER Impact: No Table 17A 2 See Sheet No(s):01

==

Description:==

(Revision)

Remove Unused Safety Classification and Seismic Category Justification:

Remove "NS" from SAFETY CLASS as it is no longer used.

Remove "II" from SEISMIC CATEGORY where associated with SAFETY CLASS 3 as it is no longer a valid category.

Group: 4 FSAR Change he uest Number: 90 078.36 SER/SSER Impacts ib O&R 010 17 See Page No(s):9.1 6 and 3.8-110

==

Description:==

(Editorial)

Replaces the response to Question 010.10 with a itieral to previously revised sections 9.1.2 and 3.8.4.1.2 Justification:

This change is made to ready the O&R section for delet-ion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90-190 Related SER Section: 9.1.2:

SSER22 9.1.2 SER/SSER Impact: No Q&R 010-18 See Page No(s):9.1-24

==

Description:==

_(Update)

Replaces the response to Question 010.11 with a revised FSAR section 9.1.3.2.1, item 19 l

Justification This change is made to ready the Q&R section for delet-ion when the USAR is prepared.

l Group 3 l

FSAR Change Request Number: 90-195.2 l

Related SER Section: 9.1.3:

SSER22 9.1.3 l'

SER/SSER Impact: No O&R 010-23 See Page No(s):9.4A 4. 9.4E 2, 15 2 16 & 18.

l

==

Description:==

(Editorial)

Replaces the response to Question 010.16 with a referra 1 to previously revised sections 15.2.6 Ind 9.4A.2.2, and revised section 9.4E.

I Justification:

This change is made to ready the 0&R esction for delet-ion when the USAR is prepared.

Group: 4 FSAR Change Request Number.90-207.2 Related SER Section: 9.4 SSER22 9.4 set /SSER 1mpact: No

e o

At' tach:ent to TXX+901031 a'

Nqve:ber 30, 1990 Page 24 of 27 FSAR Page (18 Angaded)

Dgicriotion Q&R 010 26 See Page No(s):15.2 30 & 35. Table 15.2-1 (sh 7&8)

Description (Editorial)

Deletes the response to Question 010.19 and replaces it with a referral to Sections 15.2.8,2 and 15.2.8.3, as well as to Table 15.2 1 (sh 7 & 8).

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

The current analysis of the Feedwater System Pipe Break event assumes no operator action for 30 minutes the results are accept-able as stated in Section 15.2.8.3.

The parenthetical statement referring to the incorrect 3000 seconds value specified in an earlier version of Table 15.2 1 is de-leted since it is deemed to be irrelevant to the question.

Group: 4 FSAR Change Request Number: 90 178.1 Related SER Section: 15.3.6 SER/SSER 1mpact: No Q&R 032 17

==

Description:==

(Correction)

Delete response to 032.16 and replace with a reference to section 7.2.1.1.9 which incorporates the response.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 188.01 SER/SSER Impact: No 0&R 032 19

==

Description:==

(Correction)

At 0/R 32.18 change the referenced section from 7.3.1.2.6 to 7.1.2.11.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.The referenced section was in error..The response is incorporated in 7.1.2.11 No new information is added or deleted.

Group: 4 FSAR ',hange Request Number: 90 188.02 SER/5SER Impact: No Q&R 032 31 Sr.e Page No(s):10.2 17. 15.1 21 rescription: (Editorial)

Deletes the response to Question 032.30 and replaces it with a referral to revised Section 15.1.5.1 and Section 10.2.2.7.7.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

A portion of the response is relocated to the text in Section 15.1.5.1,

    • e o

o Attach ;nt to TXX 901031 i

November 30, 1990 Page 25 of 27

'FSAR Page (n. mat!tdtd)

DescriStitD which discusses valve closures assumed in the analysis of the Steam Line Break accident; the remainder of the response is already included in Section 10.2.2.7.7.

Group: 4 FSAR Change Request Number: 90 179.1 Related SER Section: 15.3.5 SER/SSER 1mpact: No O&R 212 134 See Page No(s):4.2 6 Description (Editorial)

Deletes the response to Question 212.70 and replaces it with a referral to revised Section 4.2.1.3.

Justification This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 180.1 Related SER Section: 4.2.1 i

SER/SSER 1mpact: No 0&R 212-136 See Page No(s):15.2-14 Descriptions (Editorial)

Deletes the response to Question 212.72 and replaces it with a referral to revised Section 15.2.5.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

The information in the response is relocated (with editorial changes) to FSAR Section 15.2.5, which discusses the Loss of Con-i denser Vacuum event.

Group: 4 FSAR Change Request Number: 90 175.1 Related SER Section: 15.2.2 SER/SSER Impact: No Q&R 212-140 See Page No(s):15.3 7 Descriptions (Editorial)

Deletes the response to Question 212.76

.d reple:: it with a referral to revised Section 15.3.2.1 as well as Section 7.2.1.1.2 and Table 7.2 1.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90-176.1 Related SER Section: 15.3 SER/SSER Impact: No

. ** o o

Attach 2;nt to TXX 901031 NoWe ber 30, 1990 Page 26 of 27 FSAR Page (A1 amended)

Description O&R 212-143 See Page No(s):15.6 1

==

Description:==

(Editorial)

Deletes the response to Question 212.79 and replaces it wi+.h a referral to revised Section 15.6.1.1.

Justification:

This change is made to ready the Q & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 177,1 Related SER Section: 15.2.2 SLR/SSER Impact: No O&R 212 191 Descriotinn- (Editorial)

Deletes the response to Question 212.120 and replaces it with a referral to Sections 15.3.1.2 and 15.3.2.2.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 185.1 Related SER Section: 15.3 SER/SSER Impact: No Q&R 212-199 See Page No(s):15.2 4 DescH ption: (Editorial)

Deletes the response'to Question 212.127 and replaces it with a referral to revised Section 15.2.2.1 and to the list of references for Section 15.2.

Justification:

This change is made to ready the 0 & R section for de-letion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 187.1 Related SER Section: 15.2.2 SER/SSER Impact: No 0&R.212-206 See Page No(s):6.3 10, 15.6 27 Table 17A 1 (sh 7)

==

Description:==

(Editorial)

Deletes the response to Question 212.134 and replaces it with a referral to revised Sections 6.2.2.2.6, 15.6.5.3.2 and Table 17A 1 (sh 7), as well as Sections 5.4.7.2.2, 6.3.2, 6.3.2.2.5. Tables 6.3 9. 15.6-6 and 17A-1 (sh 4), and Figure 6.3 1 (sh 1, 4 & 5)

Justification:

This change is made to ready the O&R section for dele-tion when the USAR is prepared.

The term " minimum safeguards", which appears in the response, is deleted since that terminology is no longer used. The sheet number irdicated in the response as showing the Si and RHR pumps (i.e., sheet 3) is no longer correct; these pumps are now shown on sheets 4 and 5, respectively, of the same figure.

The single failure which the response

e a' o o

Attachment to TXX 901031 Nurember 30, 1990 Page 27 of 27 FSAR Page (11.MtPJdid)

Dg}crintion indicated was used in the large break [LOCA) analysis (i.e., partial safety injection or minimum safeguards performance, corresponding to one of each of the three different types of pumps), is changed to be consistent with the current assumption, as provided previously in a revision to the response to Question 212.65.

Group: 4 FSAR Change Request Number: 90 182.1 Related SER Section: 6.3.2 SER/SSER 1mpact: No O&R 232 9 See Page No(s):15.4 12 Descriptions (Editorial)

Deletes the response to Question 232.9 and replaces it with a referral to revised Section 15.4.2.2 and Sections 7.2.1.1.2 and 15.4.2.3.

Justification:

This change is made to ready the 0 & R section for de*

1etion when the USAR is prepared.

Group: 4 FSAR Change Request Number: 90 186.1 Related SER Section: 7.2.1 SER/SSER Impact: No i

i l

l t

1 l

l L

1