v e

ms ZION' GENERATING STATION UNIT 1/2.

?I m

. Month Seotember'

. Year 1988 3.

' SOLID' RADIOACTIVE WASTE.

~

(Tech Spec 6.6.1.D.3)

Destination Haste Principal Container Solidification Volume Activity

  • LSA/

Date of Material Material

. Radionuclides-*

NON LSA Type Agent (ft8)

(millicuries)

(If Aeolicable) 09 Dewatered

-Co-60(M)

Fe-55(E)

SEP Spent H-3(E)

N1-63(E)

LSA NA 205.8 412.39(C)

-215 88 Barnwell Resins Co-58(M) 09

..Brokered Co-60(E)

Fe-55(E) 165 x 52 SEP DAN Cs-137(E) Ni-63(E)

LSA gal drums MA 1163.25 334.38(E) 88 Oak Ridge Cs-134(E) Co-58(E) 12 Solidified' Co-60(M)

Fe-55(E) 8-120" Flat" SEP Spent Cs-134(M)

LSA Liner; Cement 125.2 35,513.98(C) 88 Barnwell Resins-Cs-137(M) -- N1-63(E)

S-53 19 Dewatered Co-60(M) Cs-134(M)

PL 14-215 SEP Spent Co-58(M)

-N1-63(E)

LSA NA 205.8 8,259.50(C) 88 Barnwell Resins Cs-137(M)

Poly HIC 22 Co-60(E)

Fe-55(E) 65 DAW SEP DAN Cs-137(E) N1-63(E)

LSA NA 626.9 480.2055 (E) 88 Richland Cs-134(E) Co-58(E)

Drums 27 Solidified Co-58(M)

N1-63(E) 8-120" Flat" SEP Spent Co-60(M)

~Fe-55(E)

LSA Liner; Cement 125.2 974,411.8(C) 88 Barnwell Resins C-14(E)

S-57 4

MONTH TOTAL 2_452.15 L919.412.26(C)

Specify whether measured-(M),-estimated (E), or a combination.(C).

k[f 0752R 9003020010 900221

~3 -

PDR -ADOCK 05000295 R

PDC r

..... w