m ZION STATION m

t.

EFFLUENT'AND HASTE DISPOSAL SEMIANNUAL REPORT 1989

/,

LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT 1 LC.. Liquid Effluents Released - Summary Sheet First Units January February March Quarter

1. Gross Radioactivity 1 a.

Total Release C1 2.9 E-1 1.1 E-1 3.6 E-1

  • 8.0 E-1 b.

Avg. Concentration pC1/ml 3.5 E-9 2.1 E-9 4.4 E-9 3.3 E-9 Released

~

c.

Max. Concentration pC1/ml 3.0 E-8 1.8 E-8 3.4 E-8 3.4 E-8 Released

0. /06 d.

% of Tech. Spec. Otr.

Limit-(1.5mR/5mR)2

/ 0.02 e.

% of Tech. Spec. Yearly 0.03 Limit (3mR/10mR)2 0.01

-2. Tritium a.

Total Release-Ci 7.2 E+1 4.6 E+1 2.1 E+1 1.4 E+2 b.

Avg. Concentration pCi/ml 8.8 E-7 8.6 E-7 2.6 E-7 6.7 E-7 Released

3. Dissolved Noble Gases a.

Total Release C1 6.2 E-2 2.0 E-1 4.0 E-2 3.0 E-1 b.

Avg. Concentration pC1/ml 7.6 E-10 3.7 E-9 4.9 E-10 1.7~E-9 Released

4. Gross Alpha Radioactivity l

a.

Total Release Ci 1.8 E-4 1.6 E-5 2.7 E-5 2.2 E-4 b.

Avg. Concentration C1/ml 2.2 E-12 -3.0 E-13 3.3 E-13 9.4 E-13 Released t

5.

Volume of Liquid Haste Liters 1.7 E+7 3.7 E+6 1.8 E+7 3.9~E+7 to Discharge 6.-

Volume of Dilution Water Liters 1.3 E+11 8.1 E+10 1.2 E+11 3.3 E+11 1 - Excludes Tritium, Alpha, and Dissolved Noble Gases 2 - Whole Body / Organ

<LLD - No detectable activity above background

- Errata data to Semi-Annual Report 2)7

~0711R 9003020009 900221

'PDR ADOCK 05000295 F

R.

PDC

=

m.

' ZION STATION l-EFFLUENT AND HASTE DISPOSAL SEMIANNUAL REPORT 1989

-LIQUID EFFLUENTS UNIT 1 D._ Liquid' Effluents Released - Isotopes fSjfUj'j Units January February March 0 ar er i,

Na-24 Ci 2.8 E-4 7.8 E-6 1.7 E-3 2.0 E-3 r

__Cr-51 Ci 5.5 E-3 1.5 E-2 1.4 E-2 3.5 E-2 Mn 1.3 E-3 9.9 E-4 1.9 E-4 2.5 E-3

__Co-57 4.2 E-3 9.1 E.5 2.9 E-5 4.3 E-3 Co-58 1.1 E-1 4.2 E-2 6.0 E-2 2.1 E-1 Fe-59 7.7 E-4 2.5 E-3 4.3 E-4 3.7 E-3 4.3 E-2

__Eg.55 Co-60 C1 7.8_E-2 1.9 E-2 3.3 E-2 1.3 E-1 Kr-85 C1

<LLD

<LLD

<LLD

<LLD

~

Kr-88

<LLD (LLD

<LLD

<LLD

__BhuB8

<LLD

<LLD

<LLD (LLD Sr-89

  • <LLD

<LLD

<LLD (LLD (LLD I

I Nb-95 C1 1.6 E-3 3.9 E-3 1.7 E-4 5.7 E-3 Zr-95 1.0 E-3 2.8 E-3 1.6 E-3 5.4 E-3 Mo-99 (LLD

<LLD 5.0 E-6 5.0 E-6

-Tc-99M

<LLD

<LLD 2.5 E-5 2.5 E-5

<LLD - No detectable activity above background

- Errata data to Semi-Annual Report 0711R-8 J

y 3

[v l.,

' ZION STATION EFFLUENT AND HASTE DISPOSAL SEMIANNUAL REPORT 1989 p'

GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES A. Gaseous Effluents Released - Summary Sheet Second Units April May June Quarter 1.

Gross Redioactivity Releases a.

Total Release Ci 7.1 E+1 1.6 E+2 4.2 E+1 2.7 E+2 b.

Max. Release Rate pCi/Hr.

2.3 E+5 3.0 E+5 3.3 E+4 3.0 E+5 c.

%-of Quarterly Limit-0.31 2

(5mRy/10mR B)1 O.79 2.

. Iodine Releases-a.

Total I-131, I-133 C1 6.3 E-5

4 E-4 9.0'E-5 3.9 E-4 j

~

3.

Particulate Releases a.

Grosri Radioactivity C1 2.1 E-4 1.0 E-3 7.8 E-3 9.0 E-3.

l 1

b.

Gro:s Alpha C1

  • <LLD c.

Gross Particulate with C1 4.5 E-5 2.7 E-4

~7.8 E-3 8.1 E-3 i

Half Lives > 8 Days j

4.

Sum of I-131, I-133 & Particulate Hith Half Lives Greater Than 8 Days a - Total C1

~1.1 E-4 5.1 E-4 7.9 E-3 8.5 E-3_

]

l b.

%'of Quarterly. Limit 3.52 (7.5 mR Organ) 5.

Trittum R91 eases j

r a.

Total Release Ci 9.2 E-1 3.5 E0 8.6 E-1 5.3 E0

)

h

~~

o 1-Noble Gas Gamma / Beta Errata data to the Semi-Annual Report

<LLD - No detectable activity above background 13

'0685R 1

p-ZION STATION 1

EFFLUENT AND HASTE DISPOSAL SEMIANNUAL REPORT 1989 GASE0US EFFLUENTS - ELEVATED RELEASE Gaseous Effit:ents Released - Itotopes (continued)

Second Isotopes Units April May June Ouarter Released-3.

Particulate Releases

__HA-24 Ci 5.8 E-7 1.0 E-6 7.9 E-7 2.4 E-6

__MD-54

__ <LLD

<LLD

<LLD

<LLD Mn-56

<LLD

<LLD 2.4 E-8 2.4 E-8 Co-58 C1 1.2 E-8 1.9 E-4 8.7 E-9 1.9 E-4

__Co-60 7.0 E-10 2.5 E-9 2.6 E-8 2.9 E-8 Ci Br-82

<LLD

<tLD

<LLD (LLD 1

Rb-88 Ci 3.8 E-5 7.3 E-5.

7.8 E-3 7.9 E-3

  • 1.2 E-8 Sr-91' Ci

<LLD__

<LLD

<lLD

<LLD Sr-92 (LLQ____

<LLD

<LLD (LLD Nb-95

<LLD 3.5 E-9

<LLD 3.5 E-9 Ci Mo-99 1.2 E-8 1.5 E-8 3.2 E-8 5.9 E-8 Tc-99M

<LLD

<LLD

<LLD

<LLD

<LLD - No detectable activity above background

- Errata data to the Semi-Annual Report 16 0685R

p ZION STATION

+-

s-EFFLUENT AND HASTE DISPOSAL SEMIANNUAL REPORT 1989

. LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES 3,:;

UNIT 1 C.l Liquid Effluents Released - Summary Sheet Second Units April May June-Quarter 1.

Gross Radioactivity 1

a. ~ Total Release C1 3.6 E-2

<LLD

<LLD

  • 6.3 E-2 b.

Avg. Concentration Ci/ml' l.2 E-9 (LLD

<LLD 4.0 E-10 Released a

c.

Max. Concentration pC1/mi 6.7 E-9

<LLD.

<LLD 6.7 E Released d.

% of Tech Spec. Qtr.

0'.01 Limit (1.5mR/5mR)2 0.00 0.03 e.

% of Tech. Spec. Yearly-Limit (3mR/10mR)2 0.01 2.-

Tritium a.

Total Release C1 2.2 E+1 3.2 E-3 1.3 E 2.2 E+1 b.

C centration pCi/ml 7.1-E-7 2.3 E-10 6.4 E-10 2.4 E-7 3.

Dissolved Noble Gases-a.

Total' Release C1 2.9 E-2

--. < LLD

<LLD 2.9 E,

b.-

C centration pC1/ml 9.4 E-10

<LLD

<LLD 3.1 E-10 4.

Gross Alpha Radioactivity l

a.

Total Release Cl 8.-9 E-7

<LLD

<LLD 8.9 E-7 b.

Av C centration pC1/ml 2.9 E-14

<LLD-

<LLD 9.7 E-15 5.

Volume of Liquid Haste to Discharge 1.9E+6l Liters 1.3 E+6 2.1 E+6 5.3 E+6 6.

Volume of Dilution Water Liters 1.2 E+11 1.1 E+11 1.1 E+11 3.4 E+11 1 - E'Acludes Tritium, Alpha, and Dissolved Noble Gases 2 - Whole body / organ

<LLD - No detectable activity above background

  • - Errata data to Semi-Annual Report 18 0685R

g ZION' STATION

[.

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1989 y

.i l'

LIQUID. EFFLUENTS

,2 UNIT.1 Liquid Effluents Released - Isotopes c

.l Second i

Isotopes Units April May June

~

Ouarter Released

_fla Ci

<LLD

<LLD

<LLD

<LLD Ar-41

<LLD

<LLD

<LLD

<LLD Cr-51 Ci

<LLD

<LLD

<LLD

<LLD

_)tl..54

<LLD

<LLD

<LLD

<LLD

_Co-57

<lLD

<LLD

<LLD

<LLD

_Co-58 4.4 E-3

<LLD

<LLD 4.4 E-3

. Fe-59 (LLD

<LLD

<LLD

<LLD

  • 2.7 E-2 Me-li5 Co-60 Ci 2.6 E-3

<LLD

<LLD 2.6 E-3 1

Kr-85 Ci

<LLD

<LLD

<LLD

<LLD Kr-88

<LLD

<LLD

<LLD

<LLD Rb-88

<LLD

<lLQ

<LLD (LLD

  • <LLD Sr-92

<LLD

<LLD

<LLD

<LLD 4

l' Nb-95 C1

<LLD

<LLD

<lLD

<LLD

-Zr-95

<LLD'

<LLD (LLD

<LLD Mo-99 2.4 E-4

<LLD

<LLD 2.4 E-4

<LLD - No detectable activity above background

- Errata data to Semi-Annual Report 19 0685R n-

-