TOLEDO

%ms EDISON Docket No. 50-346 N CHAAD P. Cnoust License No. NPF-3 EffU" Serial No. 822 ut ai ada s221 June 1, 1982 Director of Nuclear Reactor Regulation Attention:

Mr. John F. Stolz Operating Reactor Branch No. 4 Division of Operating Reactors United States Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Stolz:

Under separate cover, we are transmitting three (3) original and forty (40) conformed copies of an application for Amendment to Facility Operating License No. NPF-3 for the Davis-Besse Nuclear Power Station Unit No. 1.

This application requests that the Davis-Besse Nuclear Power Station Unit 1 Technical Specifications, Appendix A, be revised to reflect the changes attached. The proposed changes involve Technical Specifications contained in the Cycle 3 reload report (BAW - 1707 February 1982, submitted March 5, 1982, Serial No. 787).

The proposed change concerns the Reactor Protection System trip setpoints contained in Cycle 3 reload report. The proposed change to this trip setpoints is to eliminate the dual inclusion of the calibration related errors which presents an unnecessary restriction on plant operation.

This amendment request contains a revision of a previous submittal.

Therefore, no fee is incurred.

Very truly yours, t

/ffh= -

i RPC: GAB hf Attachment g

cc:

DB-1 Resident Inspector

/ /

l l

l l

THE TOLEDO ED:SCN COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO. OHIO 43652 l

I 8206070090 820601 PDR ADOCK 03000346 P

PDR