Application to Amend Licenses DPR-57 & NPF-5,changing Tech Specs to Provide Emergency Relief from Drywell Inerting Limiting Condition,Rod Pattern Adjustments & Rod Block Clamp & Extension for Inoperable LPCI Inverter
ML20050C806
Person / Time
Site: Hatch  
Issue date: 04/05/1982
From: Beckham J
GEORGIA POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20050C807 List:
References
TAC-47885, TAC-48295, TAC-48297, NUDOCS 8204090369
Download: ML20050C806 (2)


Text

.

nmaw.vcrwi

, av p,n m i. vw.

/ ?:anta G.:Na a 3'n%

T+ deDN.f:0404 $26-7070 MFi N Ady %

Pc ! O' r o B.w ".545 A!w ta G<a eg a 30332 April 5, 1982 J. T. Beckham, Jr.

/ r., Pn - 9 r.t r et Genug f/ana7e Nw '.;ar G,

,.t-n G

Director of Nuclear Reactor Regulation 8

\\

U. S. Nuclear RegulatoIy Commission NECElyED Washington, D. C.

20555 9'

Apgg 7gg2h 72

{k maar%p T8C NRC DOCKETS 50-321, 50-366 a

UPERATING LICENSES DPR-57, NPF-5 4

EDWIN I. HATCH NUCLEAR PLANT UNITS 1, 2 g

REQUEST FOR CHANGES TO THE TECHNICAL SPECIFICATIONS Gentlemen:

Pursuant to 10 CFR 50.90, Georgia Power Company hereby Iequests changes to the Technical Specifications ( Appendix A to the Operating Licenses) for Units 1 and 2 of Plant E. I. Hatch.

Each requested change is presented as a separate attachment which includes a description of the requested change, copies of affected pages, and instructions for incorporation into the Technical Specifications.

Following is a brief description of the requested change for each attachment: -

ConfirmatoIy submittal for emergency relief of dIywell inerting LCO for Unit 1 per our letter of February 8, 1982. -

Extends time for corrective actions for making rod pattern adjustments for Unit 2. -

Adds a RBM rod block clamp at 107% of rated power on Unit 1. -

Extends LCO for an inoperable LPCI inverter for Unit 2.

Included with the proposed changes is a determination of amendment class (attachment 5).

We have deteImined this to be one Class 1;V amendment.

Payment is enclosed accordingly.

l y

d s. O 6

1 8204090369 820405 PDR ADOCK 05000321 P

PDR

l GeorgiaPower A Director of Nuclear Reactor Regulation U. S. TAJclear RegulatoIy Commission Washington, D. C.

20555 April 5, 1982 Page Two J. T. Beckham, Jr. states that he is Vice President of Georola Power Company and is authorized to execute this oath on behalf of Georgir' Power Company, and that to the best of his knowledge and belief the facts set forth in this letter are true.

GEORGIA POWER C0tPANY By :

Ch h

J. T. Beckham, Jr.

Sworn to and subscribed efore me this 5th day of April,1982 k/

"//

7

()

Public Notary Public, Georgia Ste e

i REB /mb Enclnsure xc:

M. ManIy R. F. Rogers, III J. P. O'Reilly (NRC - Region II) l

}

l

.__ _