Enclosure to NA 93-0050 Page 3 of 5
+
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1992)
SOLID WASTE SHIPMENTS A.
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel) r
- 1. Type of waste Unit 6-Month Est. Total Period Error I
- a. Spent resins, filter sludges, m3*
7.10E+00 evaporator bottoms, etc.
Ci 9.58E+01 2.50E+01
- b. Dry compressible waste, m3*
18.9E+00 contaminated equip. etc.
C1 1.28E400 2.50E+01 c.
Irradiated components, m3*
0.00E+00 control rods, etc.
Ci 0.00E+00 0.00E+00
- d. Other m3*
0.00E+00 Ci 0.00E+00 0.00E+00 m3* = cubic meters
- 2. Estimate of major nuclide composition (by type of waste)
Spent resins, filter sludges, evaporator bottoms, etc.
a.
Nuclide Percent Name Abundance Curies Cs-134 24.061%
2.30E+01 Cs-137 20.848%
2.00E+01 t
Fe-55 20.420I 1.96E+01 Ni-63 14.694I 1.41E+01 Co-60 8.860%
8.49E+00 Co-58 4.332%
4.15E+00 Be-7 3.257I 3.12E+00 Mn-54 2.127I 2.04E+00 Eu-155 1.274I 1.22E+00 C-14
.076%
7.28E-02 Sr-90
.028I 2.66E-02 H-3
.023I 2.19E-02 Pu-238
.0001 4.01E-05 Pu-239/40
.0002 3.94E-05 Cm-243/44
.000%
2.10E-05 Am-241
.000I 1.54E-05 Cm-242
.000%
0.00E+00 Pu-241
.000%
0.00E+00 1-129
.000%
0.00E+00 Tc-99
.000%
0.00E+00 Nb-94
.000%
0.00E+00 Ni-59
.000%
0.00E+00 9303150179 930309 PDR ADOCK 05000482 R
Enclosure to'NA 93-0050 Page 4 of 5 4
i w
- b. Dry compressible waste, contaminated equipment, etc.
Nuclide Percent Name Abundance Curies Fe-55 58.318Z 7.44E-01 Co-60 25.642Z 3.27E-01 Ni-63 7.700Z 9.82E Co-58 2.338Z 2.98E-02 i
Nb-95 1.723Z 2.20E-02 Cs-137 1.549Z 1.98E-02 Mn-54 1.411Z 1.80E-02 Cs-134 1.105Z 1.41E-02 I-131
.175Z 2.23E-03 H-3
.026Z 3.28E-04 Cr-51
.009Z 1.19E-04 C-14
.003Z 4.10E-05 Cm-242
.000%
0.00E+00 Pu-241
.000%
0.00E+00 I-129
.000%
0.00E+00 Tc-99
.000Z 0.00E+00 Sr-90
.000%
0.00E+00 Nb-94
.000%
0.00E+00 Ni-59
.000%
0.00E+00 c.
Irradiated components, control rods, etc.
none i
d.
Other none
- 3. Solid Waste Disposition L
Number of Shipments Mode of Transportation Destination 5
Truck
- Barnwell, South Carolina 4
Truck Richland, Washington 4.
Class of Solid Waste a.
Class A, Class B b.
Class A c.
Not applicable d.
Not applicable
- 5. Type of Container a.
LSA (Strong, tight) b.
LSA (Strong, tight) c.
Not applicable d.
Not applicable t.
-:1 f.
Enclosure to NA' 93-0050
~
Page 5 of 5-
-i
,v
- 6. Solidification Agent s.
Not applicable
-b.
Not applicable ~
' i c.
Not' applicable' d.
Not. applicable-I B.
IRRADIATED FUEL SHIPMENTS-(Disposition) i There were no irradiated fuel shipments during this reporting period..
[
t 6
h a
I
-j 1
?
.i a
)
I t
I
.]
3
- bI.
.