05000296/LER-1982-048-03, /03L-0:on 821011,following Rod Pattern Adjustment, Calculated R Factor Found Less than R Factor Used to Set Average Power Range Monitor Scram & Rod Block.Caused by Insertion of Pattern Revised Rods

From kanterella
(Redirected from ML20028A548)
Jump to navigation Jump to search
/03L-0:on 821011,following Rod Pattern Adjustment, Calculated R Factor Found Less than R Factor Used to Set Average Power Range Monitor Scram & Rod Block.Caused by Insertion of Pattern Revised Rods
ML20028A548
Person / Time
Site: Browns Ferry 
Issue date: 11/09/1982
From: Nave E
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20028A545 List:
References
LER-82-048-03L-02, LER-82-48-3L-2, NUDOCS 8211220279
Download: ML20028A548 (2)


LER-1982-048, /03L-0:on 821011,following Rod Pattern Adjustment, Calculated R Factor Found Less than R Factor Used to Set Average Power Range Monitor Scram & Rod Block.Caused by Insertion of Pattern Revised Rods
Event date:
Report date:
2961982048R03 - NRC Website

text

. ves.g w

's 1

U. h. iiUcLi. AH 66 t'*3UL A T OH 4 CO*. *.110010?J LICENSEE EVENT REPORT CO'JTROL ritocg. {

}

l l

l l

l (PLEASE PAlfJT OR TYI'E ALL REQUIRED INFORP.1ATIONI i

s.

@ l Al Ll nl Rl Fl 1l@l Ol 0l -l 0 l 0l 0 l 0 l 0 l-l 0 l 0 l@l 4 l1 l111 l1 l@l l

{

u,.., @

. 2 Uw.a u.w t

.4 n,

aw.a N U.= n a

a o w.x,,. E

,a

'J ' T T

"C I L!@l 0 15 l 01 0 l 0 l 2 l 9 l 6 !@l 1 l 0 l 1 11 l 8 l 2 l@[1 l 1 l 0 l 9 [ 8 l 2 l@

eO,

EVENT DESCalPTIOrJ A JO PMOUAG E C tJ NCES

]l Following a rod pattern adjustment, the calculated "R" factor (RRP/CMFLPD) (0.982) l g I was less than the "R" f actor used to set the APRM scram and rod block (1.0') for g

^

Bl 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and 15 minutes (T.S. 2.1.A.1.b & d).

There was no effect on public health gl or safety. The calculated scram value was not exceeded during this time.

g Bl l

Dl I

n<

l "g

9 80 SYS T E *.t cat 5E C AL:0E C O*.' P.

VALVE CCDE C'J:;E SUSCODE CO*.?PONENT CODE SU3COOE SU COOE li i I l A l@ l Xl@ l Zl@ l Z l Z l Z l Z lZ lZ lh b @ Q @

u 9

10 11 IJ 13 til

.Is 20 SECUESJ TI AL OC004 9 E NCE REPOnT RE V'0IC'A

,,,,EVENTYEAR HEPOH T NO.

CODE TYPE rio.

@,"(j[.a sagi a l 21 1-1 Inl41al

. l/l I 01 31 lLI L-j l 01

.g 21 22 2J 24 26 27 23 TJ JJ 31 32 AC Tieta S U TU r:E EFFECT SHUTUOWN A TT ACs".'E N T P. PRO-4 PRIVE CO*.*P.

CO"*C'. F J T T A F. E ra AC TI O*4 C*4 P L A *4 T WE THC,0 HOUHS SUB us TT E D FOHM Wu.

$UPPU(4 MANUFACTLHER 1 El@lc l@

IZ l@

LZ_J@

l01010101 111@

l N l@

l Zl(3 l Zl 9l 9l 9l{

JJ J4 36 JI 4J 4t J

E DESCRIPTIO*J AND COnHECTIVE ACTION.S h 42 43 44 47 CAu

'] l Event was due to the insertion of control rods required to maintain operation

[

]l with pre _ scribed load line.

Action was taken to revise the control rod pattern.

I gl "R" was within limits in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and - 15 minutes. Tech specs have been submitted l

] ! for units 2. and 3 (similar to present unit 1 tech specs) to allow 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> l

]l to correct "R".

l ea r A C 4 '. t i V

% T a l: r.

% POV.E R OTHrae,TAftt3 DKCOVLHY DISCOVER Y DESC.MH 7 UT.

) l E lh l Ol 8l 5lf3l 8

a NA l

W @l Engineer observation l

' A. r re t t y C

T E *4 r et e6 5.% J -

5.H ' t '. I

] d ((y [_gj fi;l A*.tOUN T Cf AC TIVI t Y toCA riON OF HELE A';E ; 'l NA l

l NA l

1

')

80 t1 44 4',

  • r. n * ;,. ; e,,

r. e...i s t e, 84

  • t,7 *. t e s f t p s.

71(',Jn.r f tf /4 1

I!0!OI0.jQ'dIhl NA l

.o....

. t ' to P t o;*.

..a 'i..o. ' !. t.;

8 l 01010 @\\

NA l

.i i

o,.... w.a..t ro r.w i.i< Ug

.c..,,3.

[ Z lG l NA l

i l

8211220279 821109 "7' U.$....,,, :. (h

$DRADOCK 05000296 NdC '6L c:st <

S,}d',I PDR g

g;;;;;;,[;[]

si -

..v E ce c.,r, an t o Parl Nave (20'O 7 20--nu s

i

.6 Tennessee Vallev Authority Form BF 17 Brov:ns Ferry Nuclear I'lant BF 15.2 2/12/82 LER SUPPLIGIENTAL INFORMATION BFit0-50 _296_/. 82048 Technical specification Involve (l 2.1.A.L b&d i

Reportet! Unth:r Technical Specification _h,L2 b..(2)* Date Due NRC 11/10/gp 3

E-

.: ':a rra t i....

I I

Unit 1 was operating at 97-percent power; unit 2 was in a refueling outage.

These units were unaffected by this event. Unit 3 was operating at 85-percent power following a control rod pattern adjustment. The unit was prevented from returning to full power following the control rod pattern due to feed pump problems. The delay at low flow caused a gradual load line increase as xenon burned out.

h' hen control rods were inserted as required to reduce the load line, "R" was reduced to 0.982 at 0122. This condition was in violation of Technical Specification 2.1.A.1.b and 2.1.A.1.d since the "R" factor setpoint was 1.0.

The red pattern was readjusted and the "R" was within limits (1.008) at 0337. There was no effect on public health or safety. The calculated APRM scram value was i

not exceeded during this event. A technical specification revision ~has been proposed and submitted to the NRC to allow up to six hours for "R" factor being less than the "R" setpoint as currently permitted by unit 1 technical specifications.

9'

.:. i, u..eui!.:. cer BFRO-50-259/82019 260/81037, 82022 296/81045, 81041, 81040, 82038 t'

Peri n! - I.:fet i :, th".pon:,ibili:V - iketuaent C ntrol Supervisor

,...fv'

(

I

. :,.. u.

,j