LER-1982-046, Forwards LER 82-046/03L-0
Event date:
Report date:
2961982046R00 - NRC Website

text

'

e a

~

4 TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 37401 1750 Chestnut Street Tower II T

October 27, 1982 cc N

w

' ' T:

co c,

>~

.-4 22 Mr.' James P. O'Reilly, Director ro I -A U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement p

S.

I Region II 5

g 101 Marietta Street, Suite 3100

i n Atlanta, Georgia 30303 c.O Tj,

w a

Dear Mr. O'Reilly:

a TENNESSEE VALLEY AUTHORITY - BROWNS FERRY NUCLEAR PLANT UNIT 3 - DOCKET NO. 50-296 - FACILITY OPERATING LICENSE DPR REPORTABLE OCCURRENCE REPORT BFRO-50-296/82046 The enclosed report provides details concerning a malfunction of 3D diesel generator speed control governor. This report is submitted in accordance with Browns Ferry unit 3 Technical Specification 6.7.2.b(2).

Very truly yours, TENNESSEE VALLEY AUTHORITY h..,J.Gredd(Y Director of Nuclear Power 1

Enclosure cc (Enclosure):

Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center Institute of Nuclear Power Operations Suite 1500 1100 Circle 75 Parkway 4