MONTHYEARML20024E9291983-08-30030 August 1983 Application to Amend CPPR-100 Extending Completion Date to 831231 to Allow for Potential Delays in Const & Testing. Supporting Documentation Encl ML20041D9261982-03-0202 March 1982 Application to Amend CPPR-100,extending Completion Date to 830930.EIA Supporting Request & Fee Encl ML20004B8971981-05-20020 May 1981 Request for Amend of CPPR-99,revising Latest Completion Date to 820430.Fee Encl 1983-08-30
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20210R3501999-08-13013 August 1999 Application for Amends to Licenses NPF-11 & NPF-18,allowing Performance of CRDM & Ni Replacement to Not Be Considered Core Alterations During Operational Condition 5,Refueling, While Fuel Is in Reactor Vessel ML20210Q3951999-08-0606 August 1999 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Section 3/4.6.4, Vacuum Relief, by Removing Specific Operability Requirements Related to Position Indication for Suppression chamber-drywell Vacuum Breakers ML20209G3551999-07-14014 July 1999 Application for Amends to Licenses NPF-11 & NPF-18 to Revise TS Allowing Both LaSalle County Units to Operate at Uprated Power Level of 3489 Mwt.Proprietary Rev 2 to NEDC-32701P, Power Uprate Sar..., Encl.Proprietary Encl Withheld ML20209D3171999-07-0707 July 1999 Application for Amends to Licenses NPF-11 & NPF-18,revising MCPR Safety Limit & Adding Approved Siemens Power Corp Methodology List of TRs for COLR ML20209D3881999-07-0707 July 1999 Suppl Application for Amends to Licenses NPF-11 & NPF-18, Changing Proposed Degradation Voltage Low Limit Setpoint & Adding High Limit Setpoint & Allowable,Per 981109 Application ML20206T1331999-05-19019 May 1999 Application for Amends to Licenses NPF-11 & NPF-18, Relocating TS Section 3/4.4.4, Chemistry, to UFSAR to Be Consistent with NUREG-1433,rev 1 ML20206J6921999-05-0505 May 1999 Application for Amends to Licenses NPF-11 & NPF-18,to Revise Basis for Evaluation of Vr Exhaust Plenum Masonry Walls for Plant.With One Oversize Drawing ML20195E0471998-11-0909 November 1998 Application for Amends to Licenses NPF-11 & NPF-18,to Modify Degraded Voltage Second Level Undervoltage Relay Setpoint & Allowable Value in TS 3/4.3.3 & TS Table 3.3.3-2 ML20195D9931998-11-0909 November 1998 Application for Amends to Licenses NPF-11 & NPF-18,to Add Automatic Primary Containment Isolation on Ambient & Differential Temperature to High for RWCU Sys Pump,Pump Valve,Holdup Pipe & Filter/Demineralizer Valve Rooms ML20154M4551998-10-16016 October 1998 Application for Amends to Licenses NPF-11 & NPF-18,lowering Power Level Below Which TCV & TSV Closure Scram Signals & EOC-RPT Signal Are Not in Effect.Proprietary Rev 1,suppl 1 to NEDC-31531P,encl.Proprietary Info Withheld ML20217B5721998-04-16016 April 1998 Supplemental Application for Amend to License NPF-11, Changing Leak & Break Detection Isolation Instrumentation. Util Response to RAI & Rev 1 to Calculation L-001443,encl ML20217J2731998-03-24024 March 1998 Application for Amends to Licenses NPF-11 & NPF-18,deleting License Condition 2.C.(30)(a) in Entirety & Revising TS 6.1-3 ML20203G4871997-12-12012 December 1997 Application for Amends to Licenses NPF-11 & NPF-18,modifying Bypass Logic for Msli Valve Isolation Actuation Instrumentation on Condenser Low Vacuum as Stated in Note of TS Tables 3.3.2-1 & 4.3.2.1-1 ML20199K5181997-11-24024 November 1997 Application for Amend to License NPF-11,adding Automatic Primary Containment Isolation on Ambient & Differential Temp High for RWCU Pump,Pump Valve,Holdup Pipe & F/D Valve Rooms. W/Environ Assessment Statement & Calculations ML20211P9171997-10-15015 October 1997 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Unnecessary Details from Accident Monitoring Instrumentation Surveillance Requirements ML20217C3581997-09-26026 September 1997 Application for Amends to Licenses NPF-11 & NPF-18,adding Ventilation Filter Testing Program ML20141J5521997-08-12012 August 1997 Application for Amends to Licenses NPF-11 & NPF-18,proposing Deletion of Surveillance Requirement 4.7.1.3.c & Addressing Sedimentation Concerns in Intake Structure Under Svc Water Performance Monitoring Program,Iaw GL 89-13 ML20148U2551997-07-0101 July 1997 Application for Amends to Licenses NPF-11 & NPF-18,changing Definition of Channel Calibration & Correcting Miscellaneous Errors in TS & Bases ML20148Q4161997-07-0101 July 1997 Application for Amends to Licenses NPF-11 & NPF-18,revising TSs to Reflect Improvements Made to Control Room Ventilation Air Intake Radiation Monitoring Sys Logic to Reduce Spurious Actuation of Emergency Filtration Mode of Operation ML20141L0311997-05-27027 May 1997 Application for Amends to Licenses NPF-11 & NPF-18, Incorporating Restructured Station Organization,Change to Submittal Frequency of Radiological Effluent Release Rept & Other Administration Changes ML20137W5071997-04-14014 April 1997 Application for Amends to Licenses NPF-11 & NPF-18,changing TS to Reflect Design Change to Trip Logic for Feedwater/Main Turbine Trip Sys Actuation Instrumentation for Reactor Vessel Water Level-High,Level 8 Trip Function ML20134A1781997-01-20020 January 1997 Application for Amends to Licenses NPF-11 & NPF-18, Requesting Relocation of Alarm Only Instrumentation Surveillance Requirements & Adding or Changing Action Statement for Selected TSs ML20135E6551996-12-0202 December 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising Section 3.4.2 SRV Configuration to Include Only 13 of Current 18 SRVs ML20129J4461996-10-31031 October 1996 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Seismic Monitoring Instrumentation Requirements ML20116A9501996-07-15015 July 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising App A,Ts,Per 10CFR50.90 to Relocate Fire Protection Requirements of Listed TS Sections ML20113C8581996-06-21021 June 1996 Application for Amends to Licenses NPF-11 & NPF-18,including Extension of 18 Month Surveillance Interval & One Time Change to TS to Extend AOT for Each Subsystem of CR & Auxiliary Electric Equipment Room Emergency Filtration Sys ML20107F0541996-04-16016 April 1996 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Selected Response Time Testing Requirements ML20107A8351996-04-0808 April 1996 Application for Amends to Licenses NPF-11 & NPF-18, Reflecting Transition of Fuel Supplier from GE to Siemens Power Corp.Nonproprietary & Proprietary Versions of EMF-94-217,Rev 1 Repts Encl.Proprietary Rept Withheld ML20097D6451996-02-0909 February 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising TS to Support Elimination of MSIV Leakage Control Sys & Instead Use MSL Drains & Condenser to Process MSIV Leakage ML20096G3261996-01-18018 January 1996 Application for Amends to Licenses NPF-11 & NPF-18,changing Setpoints for Automatic Primary Containment Isolation on MSL Tunnel Differential Temp High & Deleting Automatic Isolation Function on MSL Tunnel Temp High ML20095K6931995-12-21021 December 1995 Application for Amends to Licenses NPF-11 & NPF-18,deleting TS LCO 3.4.2,Action Statement B ML20093D4251995-10-0202 October 1995 Application for Amend to License NPF-11,revising SRV Safety Function Lift Setting Tolerance.Nonproprietary & Proprietary Versions of GE SRV Setpoint Tolerance Relaxation Analysis Encl.Proprietary Analysis Withheld ML20091P8901995-08-28028 August 1995 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating MSIV Leakage Control Sys & Increasing MSIV Leakage Limits,Including Request for Exemption for MSIV Leakages from Acceptance Test Criteria in App J of 10CFR50 ML20084U2921995-06-0808 June 1995 Application for Amends to Licenses NPF-11,NPF-18,NPF-72, NPF-77,NPF-37 & NPF-66.Amends Would Revise SRs & Administrative Requirements Associated W/Edgs ML20084C2221995-05-23023 May 1995 Application for Amends to Licenses NPF-11 & NPF-18, Clarifying Described Equipment out-of-svc Options ML20083P6211995-05-19019 May 1995 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Requirement That Verifies Each Fire Protection Valve in Correct Position at Least Once Per 31 Days ML20082J9261995-04-11011 April 1995 Application for Amends to Licenses NPF-11 & NPF-18,extending Specific 18 Month TS Surveillance Requirements to Allow Surveillance Testing ML20087H7851995-03-31031 March 1995 Application for Amend to License NPF-18,revising SRV Safety Function Lift Setting Tolerances.Nonproprietary & Proprietary GE SRV Setpoint Relaxation Analysis Encl. Proprietary GE SRV Setpoint Relaxation Analysis Withheld ML20078H1441995-01-30030 January 1995 Application for Amend to License NPF-18,requesting Emergency Amend to TS 3.3.1,for One Time Extension of Functional Test for Main Steam Line Isolation Valve - Closure Scram Functional Unit in RPS ML20077S2901995-01-13013 January 1995 Application for Amends to Licenses NPF-11 & NPF-18,to Revise Pressure Alarm Setpoint Allowable Values for ECCS & RCIC Sys Keep Filled Pressure Instrumentation Channels ML20078R7031994-12-14014 December 1994 Application for Amends to Licenses NPF-11 & NPF-18,revising TSs to Minimize Unnecessary Testing & Excessively Restrictive AOT for Certain Actuation Instrumentation. Rev 3 to MDE-83-0485 & Rev 1 to RE-025 Encl.Encls Withheld ML20078B9491994-10-24024 October 1994 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Section 3.6.Exemption Requests from 10CFR50,App J Requirements Encl ML20069J7671994-06-0909 June 1994 Application for Amends to Licenses NPF-11 & NPF-18, Implementing Partial Application of GE ARTS Program.Ge Proprietary Rept NEDC-31531P, ARTS Improvements Program Analysis... Encl.Rept Withheld (Ref 10CFR2.790(b)) ML20065A1871994-03-22022 March 1994 Application for Amends to Licenses NPF-11 & NPF-18,deleting TS 3/4.6.1.5, Primary Containment Structural Integrity ML20063F3081994-01-28028 January 1994 Application for Exigent Amends to Licenses NPF-11 & NPF-18, Revising TS 3.3.1 & 3.3.4 to Extend Surveillance Test Interval from Monthly to Quarterly.Ge Proprietary TS Improvement Analysis Encl.Ge Proprietary Analysis Withheld ML20063E1631994-01-24024 January 1994 Application for Amends to Licenses NPF-11 & NPF-18,deleting Requirement for Response Time Testing Where Required Time Corresponds to Diesel Start Time from TS Table 3.3.2-3,per Line Item 5 of GL 93-05 & NUREG-1366 ML20063B2311994-01-21021 January 1994 Suppl to 931228 Application for Amends to Licenses NPF-11 & NPF-18,changing TS Bases Section B 3/4 2-6 to Include Ref to Plant LOCA Analysis Performed by GE ML20059E2681993-12-30030 December 1993 Amends 57,57,45,45,93,77,152 & 140 to Licenses NPF-37, NPF-66,NPF-72,NPF-77,NPF-11,NPF-18,DPR-39 & DPR-48, Respectively.Amends Change Instantaneous Limits for Radioactive Liquid & Gaseous Effluent Release Rates ML20058K3371993-12-10010 December 1993 Application for Exigent Amend to License NPF-11,revising TS 3.4.2, Safety Relief Valves, Adding Footnote to Exempt Safety/Relief Valves 1B21-F013B & 1B21-F013F from Requirements of TS 4.0.3 ML20058A8661993-11-17017 November 1993 Application for Emergency Amends to Licenses NPF-11 & NPF-18,requesting NRC Approval of USQ Re Existing Condition for Which Operator Action Proposed for Tripping Mechanical Vacuum Pump in Place of Automatic Trip 1999-08-06
[Table view] |
Text
. . .
I Commonwealth Edison
]O
'\
-\
) one First National PlazS,' Chicago, I!!inois
~7 Address Reply to: Post Office Box 767
/ Chicago, Illinois 60690 August'30, 1983 Mr. H:trold R. Denton, Director-Office of. Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
LaSalle County Station Unit 2 Construction Permit Extension Request NRC Docket No. 50-374 References (a): V. F. Moora letter to B. Lee, Jr. dated September 10, 1973 transmitting Construction Permit No. CPPR-100.
(b): R. S. Boyd letter to B. Lee, Jr. dated May 31, 1978 transmitting extension to Construction Permit No. CPPR-100.
(c): O. D. Parr letter to D. L. Peoples dated January 17, 1980 transmitting extension
/
to Construction Permit No. CPPR-100.
(d): R. A. Purple letter to L. O. DeGeorge dated May 3, 1982 Transmitting Extension to Construction Permit No. CPPR-100.
(e): L. O. DelGeorge letter to H. R. Denton dated March 2, 1982.
Dear Mr. Denton:
Commonwealth Edison requests an amendment to the LaSalle County Station Construction Permit CPPR-100 as issued by Reference (a) and amended by Reference (b), (c), and (d). This request is made pursuant to the provisions of 10 CFR 50.55(b). For the reasons delineated below, we request that the " latest completion date" be revised to December 31, 1983 ,
for LaSalle County Unit 2. This amendment does not in the judgement of '
the applicant, involve a significant hazard consideration. The revised completion date reflects a conservative estimate of actual construction and testing completion allowing margin for potential future delays. The specific bases upon which this request for extension is founded, are the ;
l following .
1 1.' Because Unit 2 Fuel Load is scheduled for September 30, 1983, any slippage would bring us beyond our Construc-tion Permit expiration date.
- 2. Potential delays due to late part delivery has, and continues to, impact Preoperational Testing. As testing on Unit 2 continues requirements for parts for equipment \ I replacement and maintenance continue to show up. As TyI 8309070307 830830 t I l
{
PDR ADOCK 05000374 A PDR 486j- V IfM" CMLON e
l l
H. R'. Denton August 30,.1983 discussed in Reference (e) paragraph 2, delivery of key parts may impact our schedule of Preoperational Completion. Our primary concerns are instrumentation and valve delivery.
It should again be emphasized that the factors addressed in this request do not involve a'significant hazard consideration. There are no major unreviewed safety questions involved as evidenced by the statement of the Advisory Committee on Rcactor Safeguards (ACRS) in the letter from J. Carson Mark to J. M. Hendrie dated April 16, 1981. In addition, Supplement 5 to NUREG 0519, the Safety Evaluation Report stated to the operation of LaSalle County Station, Units 1 and 2,. states:
"On the basis of its review, the NRC staff concludes that subject to certain license conditions and the favorable resolution of the other items discussed herein, the LaSalle County Station Unit 2 may be operated safely in accordance with the license conditions and Techni-cal Specifications without undue risk to the health and safety of the general public."
Also attached is a proposed " Finding of No Significant Impact" (FONSI) prepared by Commonwealth Edison to address the negative environmental impact of this construction permit extension request.
Three (3) signed originals and thirty-seven (37) copies of this submittal are provided for your review and approval.
Enclosed is a check in the amount of $1,200.00 submitted in accordance with the fee schedule defined in Section 170.22 of 10 CFR 170, in support of this construction permit extension request.
Very uly you ,
D. L. Farrar Director of Nuclear Licensing 1m cc: Mr. R. G. Page - Uranium Fuel Licensing Branch Division of Fuel Cycle and Material Safety NRC Resident Inspector - LSCS SUBSCRIBED and SWORN to before me this 3 D e-4 day of // n c o 4-r , 1981 0erbE Y.
Notary Public c, .
7218N
ENVIRONMENTAL IMPACT' APPRAISAL SUPPORTING THE REQUEST-FOR EXTENSION-OF THE DATE'FOR COMPLETION OF CONSTRUCTION OF-LASALLE COUNTY-STATION. UNIT 2-(CPPR-100)
COMMONWEALTH EDISON COMPANY DOCKET NO. 50-374
- 1. Description or proposed Action The, action requested is the issuance of an ORDER pertaining to the LaSalle County Station-(LSCS), Unit No. 2. The G3 DER would 6 extend for 4 months the latest date for completion of Unit No. 2.
The construction permit for Unit 2 (CPPR-100) would be extended from a latest completion -date of September 30, 1983 to December 31, 1983.
- 2. Summary Description of-the Probable-Impacts of the Proposed Action The environmental impacts associated with construction of LSCS have been previously addressed in the NRC staff's final environmental construction permit stage (FES-CP) issued February, 1973, st tement,in the NRC staff's final environmental statement, operation adbressed license stage (FES-OL) issued November, 1978, and determined by the Atomic Safety and Licensing Board in their Initial Decisions dated September 5,-1973 (6 AEC 645) and March 18,'1974 (7 AEC 289), and the Atomic Safety and Licensing Appeal Board in their decisions of October 19, 1973 ( ALAB 153, 6 AEC 821, af firmed 6 AEC 1072), and April 15, 1974 (ALAB 193, 7 AEC 423).
The Atomic Safety and Licensing Board identified in the Initial Decision the following five major effects due to construction:
A. Dredging and construction of facilities on the Illinois River will have an impact on the river bottom and channel.
4 B. The construction of the cooling lake and the station itself will involve major earthmoving and will generate some noise and dust.
C. Short-term traffic problems may occur.
D. Ancillary activities such as transmission line and rail spur construction, and the increased use of local roads may create minor impacts.
E. Station-related construction will temporarily ~ remove ninety acres of land from agricultural production.
The first two construction related effects noted above have already occurred. The_ dredging and construction of river facilities were completed in 1975. The major earthmoving activities were completed in 1976. Therefore, because these major construction effects have already occurred, the construction permit extensions will not~ add to impacts in these areas.
In respect to the third effect, the construction work force has already peaked, thus, local community-related impacts (such as traffic congestion) have already reached a maximum and are now declining.
In relation to the fourth construction effect'noted above, the rail spur has been completed, station-related heavy components have already been transported to the site and all transmission line construction has been completed.
The last effect (#E) mentioned above will generally be postponed as a result of the construction permit extensions. However, 120 acres of land on the station site have already been returned to argicultural production.
In summary, the environmental impact resulting from extending the construction permit will be either a postponement or continuation of certain identified and evaluated impacts mentioned above (effects C,D, and E above) or have already occurred (effects A and B).
The Appeals Board highlighted another impact due to construction: The creation of the cooling lake which resulted in the removal of approximately 2058 acres of arable farmland from agricultural use. This impact has already occurred, and the extension of the construction permits, therefore, will result in no further adverse effect relative to changes in land use.
Subsequent to construction of the cooling lake, significant erosion was identified downstream from the station site along the banks of a drainage creek called Armstrong Run. The banks of the run have been reshaped and reseeded and vegetation has been established on the dike that insures maximum flows in the run will be less than preconstruction levels. This construction effect has been corrected and should not recur.
-;e
- On May 23, 1979, in a letter from-C. Reed to 0. Parr, the NRC was notified of the existence of-erosion on certain portions of the make-up.and blowdown water pipeline corridor. Reshaping of the affected areas occurred in August of 1979, followed by seeding in September. The construction permit extensions would not result in any additional erosion impacts.
The blowdown'line ruptured on-January 23, 1980 at Station 125 +
00 (about 2 miles from the Illinois River). The water flowed across Edison property damaging a driveway'and depositing silt in a drainage ditch. .
The pipeline was repaired by February 12, 1980. The driveway was repaired and ditch dredged in March, 1980. The pertinent areas were reseeded in June 1980.
This construction effect has been corrected and should not recur.
The monitoring program at groundwater observation wells around the cooling pond have indicated a general rise in water levels. We will continue to monitor these wells until it has been determined if it is a construction effect or not. If it is a construction effect, methods to alleviate the situation will be investigated. In as much as the cooling pond has been filled since 1978, the effect, if any, will have already occurred and extension of the construction permit would not result in any additional impacts.
- 3. Conclusion and Basis for Finding of No Sianificant Impact 10n the basis of the above, it is concluded that there will be no significant impacts attributable to the requested action other than those already predicted and described in the FES-CP issued in February, 1973, the FES-OL issued in November, 1978, the Board's Initial Decisions issued in September, 1973 and March, 1974, subsequent Appeal Board Decisions, or described herein.