MONTHYEARML20210R3501999-08-13013 August 1999 Application for Amends to Licenses NPF-11 & NPF-18,allowing Performance of CRDM & Ni Replacement to Not Be Considered Core Alterations During Operational Condition 5,Refueling, While Fuel Is in Reactor Vessel ML20210Q3951999-08-0606 August 1999 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Section 3/4.6.4, Vacuum Relief, by Removing Specific Operability Requirements Related to Position Indication for Suppression chamber-drywell Vacuum Breakers ML20209G3551999-07-14014 July 1999 Application for Amends to Licenses NPF-11 & NPF-18 to Revise TS Allowing Both LaSalle County Units to Operate at Uprated Power Level of 3489 Mwt.Proprietary Rev 2 to NEDC-32701P, Power Uprate Sar..., Encl.Proprietary Encl Withheld ML20209D3881999-07-0707 July 1999 Suppl Application for Amends to Licenses NPF-11 & NPF-18, Changing Proposed Degradation Voltage Low Limit Setpoint & Adding High Limit Setpoint & Allowable,Per 981109 Application ML20209D3171999-07-0707 July 1999 Application for Amends to Licenses NPF-11 & NPF-18,revising MCPR Safety Limit & Adding Approved Siemens Power Corp Methodology List of TRs for COLR ML20206T1331999-05-19019 May 1999 Application for Amends to Licenses NPF-11 & NPF-18, Relocating TS Section 3/4.4.4, Chemistry, to UFSAR to Be Consistent with NUREG-1433,rev 1 ML20206J6921999-05-0505 May 1999 Application for Amends to Licenses NPF-11 & NPF-18,to Revise Basis for Evaluation of Vr Exhaust Plenum Masonry Walls for Plant.With One Oversize Drawing ML20195E0471998-11-0909 November 1998 Application for Amends to Licenses NPF-11 & NPF-18,to Modify Degraded Voltage Second Level Undervoltage Relay Setpoint & Allowable Value in TS 3/4.3.3 & TS Table 3.3.3-2 ML20195D9931998-11-0909 November 1998 Application for Amends to Licenses NPF-11 & NPF-18,to Add Automatic Primary Containment Isolation on Ambient & Differential Temperature to High for RWCU Sys Pump,Pump Valve,Holdup Pipe & Filter/Demineralizer Valve Rooms ML20154M4551998-10-16016 October 1998 Application for Amends to Licenses NPF-11 & NPF-18,lowering Power Level Below Which TCV & TSV Closure Scram Signals & EOC-RPT Signal Are Not in Effect.Proprietary Rev 1,suppl 1 to NEDC-31531P,encl.Proprietary Info Withheld ML20217B5721998-04-16016 April 1998 Supplemental Application for Amend to License NPF-11, Changing Leak & Break Detection Isolation Instrumentation. Util Response to RAI & Rev 1 to Calculation L-001443,encl ML20217J2731998-03-24024 March 1998 Application for Amends to Licenses NPF-11 & NPF-18,deleting License Condition 2.C.(30)(a) in Entirety & Revising TS 6.1-3 ML20203G4871997-12-12012 December 1997 Application for Amends to Licenses NPF-11 & NPF-18,modifying Bypass Logic for Msli Valve Isolation Actuation Instrumentation on Condenser Low Vacuum as Stated in Note of TS Tables 3.3.2-1 & 4.3.2.1-1 ML20199K5181997-11-24024 November 1997 Application for Amend to License NPF-11,adding Automatic Primary Containment Isolation on Ambient & Differential Temp High for RWCU Pump,Pump Valve,Holdup Pipe & F/D Valve Rooms. W/Environ Assessment Statement & Calculations ML20211P9171997-10-15015 October 1997 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Unnecessary Details from Accident Monitoring Instrumentation Surveillance Requirements ML20217C3581997-09-26026 September 1997 Application for Amends to Licenses NPF-11 & NPF-18,adding Ventilation Filter Testing Program ML20141J5521997-08-12012 August 1997 Application for Amends to Licenses NPF-11 & NPF-18,proposing Deletion of Surveillance Requirement 4.7.1.3.c & Addressing Sedimentation Concerns in Intake Structure Under Svc Water Performance Monitoring Program,Iaw GL 89-13 ML20148Q4161997-07-0101 July 1997 Application for Amends to Licenses NPF-11 & NPF-18,revising TSs to Reflect Improvements Made to Control Room Ventilation Air Intake Radiation Monitoring Sys Logic to Reduce Spurious Actuation of Emergency Filtration Mode of Operation ML20148U2551997-07-0101 July 1997 Application for Amends to Licenses NPF-11 & NPF-18,changing Definition of Channel Calibration & Correcting Miscellaneous Errors in TS & Bases ML20141L0311997-05-27027 May 1997 Application for Amends to Licenses NPF-11 & NPF-18, Incorporating Restructured Station Organization,Change to Submittal Frequency of Radiological Effluent Release Rept & Other Administration Changes ML20137W5071997-04-14014 April 1997 Application for Amends to Licenses NPF-11 & NPF-18,changing TS to Reflect Design Change to Trip Logic for Feedwater/Main Turbine Trip Sys Actuation Instrumentation for Reactor Vessel Water Level-High,Level 8 Trip Function ML20134A1781997-01-20020 January 1997 Application for Amends to Licenses NPF-11 & NPF-18, Requesting Relocation of Alarm Only Instrumentation Surveillance Requirements & Adding or Changing Action Statement for Selected TSs ML20135E6551996-12-0202 December 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising Section 3.4.2 SRV Configuration to Include Only 13 of Current 18 SRVs ML20129J4461996-10-31031 October 1996 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Seismic Monitoring Instrumentation Requirements ML20116A9501996-07-15015 July 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising App A,Ts,Per 10CFR50.90 to Relocate Fire Protection Requirements of Listed TS Sections ML20113C8581996-06-21021 June 1996 Application for Amends to Licenses NPF-11 & NPF-18,including Extension of 18 Month Surveillance Interval & One Time Change to TS to Extend AOT for Each Subsystem of CR & Auxiliary Electric Equipment Room Emergency Filtration Sys ML20107F0541996-04-16016 April 1996 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Selected Response Time Testing Requirements ML20107A8351996-04-0808 April 1996 Application for Amends to Licenses NPF-11 & NPF-18, Reflecting Transition of Fuel Supplier from GE to Siemens Power Corp.Nonproprietary & Proprietary Versions of EMF-94-217,Rev 1 Repts Encl.Proprietary Rept Withheld ML20097D6451996-02-0909 February 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising TS to Support Elimination of MSIV Leakage Control Sys & Instead Use MSL Drains & Condenser to Process MSIV Leakage ML20096G3261996-01-18018 January 1996 Application for Amends to Licenses NPF-11 & NPF-18,changing Setpoints for Automatic Primary Containment Isolation on MSL Tunnel Differential Temp High & Deleting Automatic Isolation Function on MSL Tunnel Temp High ML20095K6931995-12-21021 December 1995 Application for Amends to Licenses NPF-11 & NPF-18,deleting TS LCO 3.4.2,Action Statement B ML20093D4251995-10-0202 October 1995 Application for Amend to License NPF-11,revising SRV Safety Function Lift Setting Tolerance.Nonproprietary & Proprietary Versions of GE SRV Setpoint Tolerance Relaxation Analysis Encl.Proprietary Analysis Withheld ML20091P8901995-08-28028 August 1995 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating MSIV Leakage Control Sys & Increasing MSIV Leakage Limits,Including Request for Exemption for MSIV Leakages from Acceptance Test Criteria in App J of 10CFR50 ML20084U2921995-06-0808 June 1995 Application for Amends to Licenses NPF-11,NPF-18,NPF-72, NPF-77,NPF-37 & NPF-66.Amends Would Revise SRs & Administrative Requirements Associated W/Edgs ML20084C2221995-05-23023 May 1995 Application for Amends to Licenses NPF-11 & NPF-18, Clarifying Described Equipment out-of-svc Options ML20083P6211995-05-19019 May 1995 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Requirement That Verifies Each Fire Protection Valve in Correct Position at Least Once Per 31 Days ML20082J9261995-04-11011 April 1995 Application for Amends to Licenses NPF-11 & NPF-18,extending Specific 18 Month TS Surveillance Requirements to Allow Surveillance Testing ML20087H7851995-03-31031 March 1995 Application for Amend to License NPF-18,revising SRV Safety Function Lift Setting Tolerances.Nonproprietary & Proprietary GE SRV Setpoint Relaxation Analysis Encl. Proprietary GE SRV Setpoint Relaxation Analysis Withheld ML20078H1441995-01-30030 January 1995 Application for Amend to License NPF-18,requesting Emergency Amend to TS 3.3.1,for One Time Extension of Functional Test for Main Steam Line Isolation Valve - Closure Scram Functional Unit in RPS ML20077S2901995-01-13013 January 1995 Application for Amends to Licenses NPF-11 & NPF-18,to Revise Pressure Alarm Setpoint Allowable Values for ECCS & RCIC Sys Keep Filled Pressure Instrumentation Channels ML20078R7031994-12-14014 December 1994 Application for Amends to Licenses NPF-11 & NPF-18,revising TSs to Minimize Unnecessary Testing & Excessively Restrictive AOT for Certain Actuation Instrumentation. Rev 3 to MDE-83-0485 & Rev 1 to RE-025 Encl.Encls Withheld ML20078B9491994-10-24024 October 1994 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Section 3.6.Exemption Requests from 10CFR50,App J Requirements Encl ML20069J7671994-06-0909 June 1994 Application for Amends to Licenses NPF-11 & NPF-18, Implementing Partial Application of GE ARTS Program.Ge Proprietary Rept NEDC-31531P, ARTS Improvements Program Analysis... Encl.Rept Withheld (Ref 10CFR2.790(b)) ML20065A1871994-03-22022 March 1994 Application for Amends to Licenses NPF-11 & NPF-18,deleting TS 3/4.6.1.5, Primary Containment Structural Integrity ML20063F3081994-01-28028 January 1994 Application for Exigent Amends to Licenses NPF-11 & NPF-18, Revising TS 3.3.1 & 3.3.4 to Extend Surveillance Test Interval from Monthly to Quarterly.Ge Proprietary TS Improvement Analysis Encl.Ge Proprietary Analysis Withheld ML20063E1631994-01-24024 January 1994 Application for Amends to Licenses NPF-11 & NPF-18,deleting Requirement for Response Time Testing Where Required Time Corresponds to Diesel Start Time from TS Table 3.3.2-3,per Line Item 5 of GL 93-05 & NUREG-1366 ML20063B2311994-01-21021 January 1994 Suppl to 931228 Application for Amends to Licenses NPF-11 & NPF-18,changing TS Bases Section B 3/4 2-6 to Include Ref to Plant LOCA Analysis Performed by GE ML20058K3371993-12-10010 December 1993 Application for Exigent Amend to License NPF-11,revising TS 3.4.2, Safety Relief Valves, Adding Footnote to Exempt Safety/Relief Valves 1B21-F013B & 1B21-F013F from Requirements of TS 4.0.3 ML20058A8661993-11-17017 November 1993 Application for Emergency Amends to Licenses NPF-11 & NPF-18,requesting NRC Approval of USQ Re Existing Condition for Which Operator Action Proposed for Tripping Mechanical Vacuum Pump in Place of Automatic Trip ML20058A2591993-11-10010 November 1993 Application for Amends to Licenses NPF-37,NPF-66,NPF-72, NPF-77,DPR-39,DPR-48,NPF-11 & NPF-18 Re Limitations on Radioactive Matl Released in Liquid Effluents,New 10CFR21 & Radioactive Matl Released in Gaseous Effluents 1999-08-06
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20210R3501999-08-13013 August 1999 Application for Amends to Licenses NPF-11 & NPF-18,allowing Performance of CRDM & Ni Replacement to Not Be Considered Core Alterations During Operational Condition 5,Refueling, While Fuel Is in Reactor Vessel ML20210Q3951999-08-0606 August 1999 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Section 3/4.6.4, Vacuum Relief, by Removing Specific Operability Requirements Related to Position Indication for Suppression chamber-drywell Vacuum Breakers ML20209G3551999-07-14014 July 1999 Application for Amends to Licenses NPF-11 & NPF-18 to Revise TS Allowing Both LaSalle County Units to Operate at Uprated Power Level of 3489 Mwt.Proprietary Rev 2 to NEDC-32701P, Power Uprate Sar..., Encl.Proprietary Encl Withheld ML20209D3171999-07-0707 July 1999 Application for Amends to Licenses NPF-11 & NPF-18,revising MCPR Safety Limit & Adding Approved Siemens Power Corp Methodology List of TRs for COLR ML20209D3881999-07-0707 July 1999 Suppl Application for Amends to Licenses NPF-11 & NPF-18, Changing Proposed Degradation Voltage Low Limit Setpoint & Adding High Limit Setpoint & Allowable,Per 981109 Application ML20206T1331999-05-19019 May 1999 Application for Amends to Licenses NPF-11 & NPF-18, Relocating TS Section 3/4.4.4, Chemistry, to UFSAR to Be Consistent with NUREG-1433,rev 1 ML20206J6921999-05-0505 May 1999 Application for Amends to Licenses NPF-11 & NPF-18,to Revise Basis for Evaluation of Vr Exhaust Plenum Masonry Walls for Plant.With One Oversize Drawing ML20195E0471998-11-0909 November 1998 Application for Amends to Licenses NPF-11 & NPF-18,to Modify Degraded Voltage Second Level Undervoltage Relay Setpoint & Allowable Value in TS 3/4.3.3 & TS Table 3.3.3-2 ML20195D9931998-11-0909 November 1998 Application for Amends to Licenses NPF-11 & NPF-18,to Add Automatic Primary Containment Isolation on Ambient & Differential Temperature to High for RWCU Sys Pump,Pump Valve,Holdup Pipe & Filter/Demineralizer Valve Rooms ML20154M4551998-10-16016 October 1998 Application for Amends to Licenses NPF-11 & NPF-18,lowering Power Level Below Which TCV & TSV Closure Scram Signals & EOC-RPT Signal Are Not in Effect.Proprietary Rev 1,suppl 1 to NEDC-31531P,encl.Proprietary Info Withheld ML20217B5721998-04-16016 April 1998 Supplemental Application for Amend to License NPF-11, Changing Leak & Break Detection Isolation Instrumentation. Util Response to RAI & Rev 1 to Calculation L-001443,encl ML20217J2731998-03-24024 March 1998 Application for Amends to Licenses NPF-11 & NPF-18,deleting License Condition 2.C.(30)(a) in Entirety & Revising TS 6.1-3 ML20203G4871997-12-12012 December 1997 Application for Amends to Licenses NPF-11 & NPF-18,modifying Bypass Logic for Msli Valve Isolation Actuation Instrumentation on Condenser Low Vacuum as Stated in Note of TS Tables 3.3.2-1 & 4.3.2.1-1 ML20199K5181997-11-24024 November 1997 Application for Amend to License NPF-11,adding Automatic Primary Containment Isolation on Ambient & Differential Temp High for RWCU Pump,Pump Valve,Holdup Pipe & F/D Valve Rooms. W/Environ Assessment Statement & Calculations ML20211P9171997-10-15015 October 1997 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Unnecessary Details from Accident Monitoring Instrumentation Surveillance Requirements ML20217C3581997-09-26026 September 1997 Application for Amends to Licenses NPF-11 & NPF-18,adding Ventilation Filter Testing Program ML20141J5521997-08-12012 August 1997 Application for Amends to Licenses NPF-11 & NPF-18,proposing Deletion of Surveillance Requirement 4.7.1.3.c & Addressing Sedimentation Concerns in Intake Structure Under Svc Water Performance Monitoring Program,Iaw GL 89-13 ML20148U2551997-07-0101 July 1997 Application for Amends to Licenses NPF-11 & NPF-18,changing Definition of Channel Calibration & Correcting Miscellaneous Errors in TS & Bases ML20148Q4161997-07-0101 July 1997 Application for Amends to Licenses NPF-11 & NPF-18,revising TSs to Reflect Improvements Made to Control Room Ventilation Air Intake Radiation Monitoring Sys Logic to Reduce Spurious Actuation of Emergency Filtration Mode of Operation ML20141L0311997-05-27027 May 1997 Application for Amends to Licenses NPF-11 & NPF-18, Incorporating Restructured Station Organization,Change to Submittal Frequency of Radiological Effluent Release Rept & Other Administration Changes ML20137W5071997-04-14014 April 1997 Application for Amends to Licenses NPF-11 & NPF-18,changing TS to Reflect Design Change to Trip Logic for Feedwater/Main Turbine Trip Sys Actuation Instrumentation for Reactor Vessel Water Level-High,Level 8 Trip Function ML20134A1781997-01-20020 January 1997 Application for Amends to Licenses NPF-11 & NPF-18, Requesting Relocation of Alarm Only Instrumentation Surveillance Requirements & Adding or Changing Action Statement for Selected TSs ML20135E6551996-12-0202 December 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising Section 3.4.2 SRV Configuration to Include Only 13 of Current 18 SRVs ML20129J4461996-10-31031 October 1996 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Seismic Monitoring Instrumentation Requirements ML20116A9501996-07-15015 July 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising App A,Ts,Per 10CFR50.90 to Relocate Fire Protection Requirements of Listed TS Sections ML20113C8581996-06-21021 June 1996 Application for Amends to Licenses NPF-11 & NPF-18,including Extension of 18 Month Surveillance Interval & One Time Change to TS to Extend AOT for Each Subsystem of CR & Auxiliary Electric Equipment Room Emergency Filtration Sys ML20107F0541996-04-16016 April 1996 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating Selected Response Time Testing Requirements ML20107A8351996-04-0808 April 1996 Application for Amends to Licenses NPF-11 & NPF-18, Reflecting Transition of Fuel Supplier from GE to Siemens Power Corp.Nonproprietary & Proprietary Versions of EMF-94-217,Rev 1 Repts Encl.Proprietary Rept Withheld ML20097D6451996-02-0909 February 1996 Application for Amends to Licenses NPF-11 & NPF-18,revising TS to Support Elimination of MSIV Leakage Control Sys & Instead Use MSL Drains & Condenser to Process MSIV Leakage ML20096G3261996-01-18018 January 1996 Application for Amends to Licenses NPF-11 & NPF-18,changing Setpoints for Automatic Primary Containment Isolation on MSL Tunnel Differential Temp High & Deleting Automatic Isolation Function on MSL Tunnel Temp High ML20095K6931995-12-21021 December 1995 Application for Amends to Licenses NPF-11 & NPF-18,deleting TS LCO 3.4.2,Action Statement B ML20093D4251995-10-0202 October 1995 Application for Amend to License NPF-11,revising SRV Safety Function Lift Setting Tolerance.Nonproprietary & Proprietary Versions of GE SRV Setpoint Tolerance Relaxation Analysis Encl.Proprietary Analysis Withheld ML20091P8901995-08-28028 August 1995 Application for Amends to Licenses NPF-11 & NPF-18, Eliminating MSIV Leakage Control Sys & Increasing MSIV Leakage Limits,Including Request for Exemption for MSIV Leakages from Acceptance Test Criteria in App J of 10CFR50 ML20084U2921995-06-0808 June 1995 Application for Amends to Licenses NPF-11,NPF-18,NPF-72, NPF-77,NPF-37 & NPF-66.Amends Would Revise SRs & Administrative Requirements Associated W/Edgs ML20084C2221995-05-23023 May 1995 Application for Amends to Licenses NPF-11 & NPF-18, Clarifying Described Equipment out-of-svc Options ML20083P6211995-05-19019 May 1995 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Requirement That Verifies Each Fire Protection Valve in Correct Position at Least Once Per 31 Days ML20082J9261995-04-11011 April 1995 Application for Amends to Licenses NPF-11 & NPF-18,extending Specific 18 Month TS Surveillance Requirements to Allow Surveillance Testing ML20087H7851995-03-31031 March 1995 Application for Amend to License NPF-18,revising SRV Safety Function Lift Setting Tolerances.Nonproprietary & Proprietary GE SRV Setpoint Relaxation Analysis Encl. Proprietary GE SRV Setpoint Relaxation Analysis Withheld ML20078H1441995-01-30030 January 1995 Application for Amend to License NPF-18,requesting Emergency Amend to TS 3.3.1,for One Time Extension of Functional Test for Main Steam Line Isolation Valve - Closure Scram Functional Unit in RPS ML20077S2901995-01-13013 January 1995 Application for Amends to Licenses NPF-11 & NPF-18,to Revise Pressure Alarm Setpoint Allowable Values for ECCS & RCIC Sys Keep Filled Pressure Instrumentation Channels ML20078R7031994-12-14014 December 1994 Application for Amends to Licenses NPF-11 & NPF-18,revising TSs to Minimize Unnecessary Testing & Excessively Restrictive AOT for Certain Actuation Instrumentation. Rev 3 to MDE-83-0485 & Rev 1 to RE-025 Encl.Encls Withheld ML20078B9491994-10-24024 October 1994 Application for Amends to Licenses NPF-11 & NPF-18,revising TS Section 3.6.Exemption Requests from 10CFR50,App J Requirements Encl ML20069J7671994-06-0909 June 1994 Application for Amends to Licenses NPF-11 & NPF-18, Implementing Partial Application of GE ARTS Program.Ge Proprietary Rept NEDC-31531P, ARTS Improvements Program Analysis... Encl.Rept Withheld (Ref 10CFR2.790(b)) ML20065A1871994-03-22022 March 1994 Application for Amends to Licenses NPF-11 & NPF-18,deleting TS 3/4.6.1.5, Primary Containment Structural Integrity ML20063F3081994-01-28028 January 1994 Application for Exigent Amends to Licenses NPF-11 & NPF-18, Revising TS 3.3.1 & 3.3.4 to Extend Surveillance Test Interval from Monthly to Quarterly.Ge Proprietary TS Improvement Analysis Encl.Ge Proprietary Analysis Withheld ML20063E1631994-01-24024 January 1994 Application for Amends to Licenses NPF-11 & NPF-18,deleting Requirement for Response Time Testing Where Required Time Corresponds to Diesel Start Time from TS Table 3.3.2-3,per Line Item 5 of GL 93-05 & NUREG-1366 ML20063B2311994-01-21021 January 1994 Suppl to 931228 Application for Amends to Licenses NPF-11 & NPF-18,changing TS Bases Section B 3/4 2-6 to Include Ref to Plant LOCA Analysis Performed by GE ML20059E2681993-12-30030 December 1993 Amends 57,57,45,45,93,77,152 & 140 to Licenses NPF-37, NPF-66,NPF-72,NPF-77,NPF-11,NPF-18,DPR-39 & DPR-48, Respectively.Amends Change Instantaneous Limits for Radioactive Liquid & Gaseous Effluent Release Rates ML20058K3371993-12-10010 December 1993 Application for Exigent Amend to License NPF-11,revising TS 3.4.2, Safety Relief Valves, Adding Footnote to Exempt Safety/Relief Valves 1B21-F013B & 1B21-F013F from Requirements of TS 4.0.3 ML20058A8661993-11-17017 November 1993 Application for Emergency Amends to Licenses NPF-11 & NPF-18,requesting NRC Approval of USQ Re Existing Condition for Which Operator Action Proposed for Tripping Mechanical Vacuum Pump in Place of Automatic Trip 1999-08-06
[Table view] |
Text
Commonw cahh lilivm Osmpany IAalle Gener.Hing Station
. 2601 North 21st f(nad Marwilles,11. 613 i ! N"'57 Tel 815 3574~61 l
October 31,1996 l United States Nuclear Regulatory Commission i Attention: Document Control Desk Washington, D.C. 20555 l l
Subject:
LaSalle County Nuclear Power Station Units 1 and 2 Application for Amendment of Facility Operating Licenses NPF-11 and NPF-18, Appendix A, Technical Specifications, Elimination of Seismic Monitoring Instrumentation Requirements ;
NRC Docket Nos. 50-373 and 50-374 ;
I Pursuant to 10 CFR 50.90, Comed proposes to revise Appendix A, Technical Specifications of Facility Operating Licenses NPF-11 and NPF 18, ;
LaSalle County Station Units 1 and 2. The proposed amendment includes l changes to the Technical Specifications (TS) to eliminate seismic monitoring l instrumentation requirements. The TS affected are TS 3/4.3.7.2," Seismic ;
Monitoring Instrumentation", Table 3.3.7.2-1, " Seismic Monitoring '
Instrumentation", Table 4.3.7.2-1, " Seismic Monitoring Instrumentation i Surveillance Requirements", and Bases Section 3/4.3.7.2, " Seismic i Monitoring instrumentation". The proposed changes are suppor1ed by NRC
]
Generic Letter 95-10, " Relocation of Selected Technical Specifications Requirements Related to instrumentation."
This proposed amendment request is subdivided as follows:
- 1. Attachment A gives a description and safety analysis of the proposeo changes in this amendment.
- 2. Attachment B includes the marked-up License / Technical Specifications pages for LaSalle Units 1 and 2 with the requested changes indicated.
- 3. Attachment C describes Comed's evaluation performed in accordance with 10 CFR 50.92 (c), which confirms that no significant hazard consideration is involved.
g nRnnon 9611060269 961031 PDR ADOCK 05000373 f f P l PDR l A Umrom company
- 4. Attachment D provides an Environmental Assessment
, Applicability Review per 10 CFR 51.21.
. This proposed amendment has been reviewed and approved by Comed On-Site and Off-Site Review in accordance with procedures. j Comed requests NRC approval of this amendment request within approximately six months. There are no specific schedule requirements associated with this amendment proposal prior to February of 1997.
1 Comed is notifying the State of Illinois of this application for amendment by transmitting a copy of this letter and its attachments to the designated state official.
If there are any further questions or comments concerning this submittal, please refer them to JoEllen Burns at (815) 357-6761, extension 2383.
Respectfully, i
/@W. T. Subalusky i Site Vice President LaSalle County Statio Enclosure cc: A. B. Beach, NRC Region til Administrator M. P. Huber, NRC Senior Resident inspector - LaSalle D. M. Skay, Project Manager - NRR - LaSalle F. Niziolek, Office of Nuclear Facility Safety - IDNS DCD - Licensing (Hardcopy; Electronic: ) i Central File l I
l I
J
l t
STATE OF ILLINOIS )
l COUNTY OF LASALLE )
Docket Nos. 50-373 50-374 IN THE MATTER OF )
COMMONWEALTH EDISON COMPANY )
LASALLE COUNTY STATION - UNITS 1 & 2 )
AFFIDAVIT I affirm that the content of this transmittal is true and correct to the best of my knowledge, information and belief.
l l
L WillT5Im t Subalusky \ .
Site Vice President l
. OFFICIAL SEAL LaSalle County Station l . JAMES W. GIESEKER l l NOTARY PUBUC, STATE OF LUNOIS
( ! WY COMWISSION EXPIRES 812 2000 Subscribed and swom to before me, a Notary Public in and for the State and County above named, this El day of CY106rdt ,19$c,_. My Commission expires on hoevsT 12_ .-19 2cco W
aww u. Aux:e<a
/ Notary Public
ATTACHMENT A DESCRIPTION OF SAFETY ANALYSIS OF THE PROPOSED CHANGES Description of the Proposed Chance This is a proposed change to Technical Specification 3/4.3.7.2, " Seismic Monitoring Instrumentation", Table 3.3.7.2-1, " Seismic Monitoring Instrumentation", Table 4.3.7.2-1, " Seismic Monitoring instrumentation Surveillance Requirements", and Bases Section 3/4.3.7.2," Seismic Monitoring Instrumentation". Comed proposes to relocate these Technical Specification requirements to licensee-controlled documents as discussed in Nuclear Regulatory Commission (NRC) Generic Letter 95-10, " Relocation of Selected Technical Specifications Requirements Related to Instrumentation." The requirements for seismic monitoring instrumentation, including a list of the components, will be included in the UFSAR and will be added to the Administrative Technical Requirements.
The proposed relocation of the Seismic Monitoring Instrumentation requirements from the Technical Specifications was initially planned to be performed in conjunction with the Improved Technical Specifications (ITS). However, the ITS is not expected to be submitted to the NRC for approval until late October,1996. Implementation of ITS is not anticipated prior to late 1997 or early 1998. This proposed change to the Technical Specifications is desired prior to the implementation of ITS to support Modification M01-1-9400128. This modification will replace existing seismic monitoring instrumentation in Panel 0PA11J with new instrumentation which are not "like-for-like" replacements. These instrument replacements will directly impact the contents of Tables 3.3.7.2-1 and 4.3.7.2-1, which contain descriptions of the instruments as described below.
Modification M01-1-9400128 is required because spare parts for the existing seismic monitor instrumentation are no longer available and because the existing instruments have a history of spurious failures, especially during thunderstorms. This modification is being performed to improve system reliability and to prevent an extended period of system non-availability due to lack of spare parts in the event of an instrument failure.
The installation of new seismic monitor instrumentation will enhance the performance of the system by reducing susceptibility to spurious trips which have been experienced in the past, particularly during thunderstorm activity. The function of the seismic monitoring instrumentation wi!I remain unchanged by this modification. There will be j no change to alarm / annuciator setpoints. There will be no change to system ,
operation apparent to operators in the Main Control Room. The replacement seismic !
monitoring instrumentation will meet or exceed the specifications of the existing j instrumentation. The replacement instrumentation uses newer technology with A-1 l
l i
i 1
~
, . i
{
ATTACHMENT A DESCRIPTION OF SAFETY ANALYSIS OF THE PROPOSED CHANGES 4
i
] improved sensitivity, improved accuracy, and wider measurement ranges. The new !
1 instrumentation will have an uninterruptible power supply, the existing instrumentation !
~does r;st. The new instrumentation will store data electronically and display it by i means of a computer and a printer for selected output. The existing instrumentation uses tape recorders and strip chart recorders for recording, playback, and display. ;
i .
4 Modification M01-1-9400128 will replace existing seismic monitor instrumentation in l J Panel 0PA11J (except for the SWP-300 annunciator panel) with new instrumentation.
Existing seismic monitor instrumentation that is being removed from Panel OPA11J includes the following instruments: the SMR-102 playback unit, the DCA-300 digital cassette accelerograph, the RSA-50 response spectrum analyzer, and the CPS-117 power supply. Replacement seismic monitor instrumentation that is being installed in Panel 0PA11J includes the following instruments: the GNC-CR12 central recorder seismic data acquisition system, the UPS (uninterruptible power supply), the computer, and the printer. The existing SWP-300 annunciator instrument will remain installed.
In addition, four field mounted SSA-302 triaxial accelerometers and their enclosures will be replaced with newer Model SSA-320 accelerometers mounted inside new stainless steel NEMA 4X weatherproof enclosures in the same locations. The existing field mounted SP-215 seismic trigger and switch will remain installed. This change will involve internal wiring changes to Panel 0PA11J to accommodate the new instrumentation. This change will involve internal wiring changes for the four new field mounted SSA-320 triaxial accelerometers. The existing field cables will be utilized for the new accelerometers. No new cable pulls will be required to support this modification.
Existing Panel OPA11J will remain in place. A seismic evaluation has been performed to document the ability of the replacement instruments to withstand a seismic event and the ability of Panel 0PA11J with the new instrumentation installed to withstand a seismic event.
A-2 ;
l
1 ATTACHMENT A DESCRIPTION OF SAFETY ANALYSIS OF THE PROPOSED CHANGES Description of the Current Operatina License / Technical Specification Reauirement Technical Specification 3.3.7.2, Limiting Condition for Opuation, Requires the seismic monitoring instrumentation shown in Table 3.3.7.2-1 to be operable at all times. With one or more seismic monitor instruments inoperable for more than 30 days, a Special Report is required to be submitted to the NRC within the next 10 days outlining the cause of the malfunction and the plans for restoring the instruments to operable I status. Therefore, plant operability is not directly impacted by inoperable seismic monitoring instrumentation.
The surveillance requirements for the seismic monitoring instrumentation are specified in Technical Specifications 4.3.7.2.1 a:1d 4.3.7.2.2. Technical Specification 4.3.7.2.1 requires that each instrument be demonstrated operable by the performance of a channel check, channel functional test, and channel calibration surveillance tests at the frequencies shown in Table 4.3.7.2-1. Technical Specification 4.3.7.2.2 requires that any seismic monitoring instrument actuated during a seismic event greater than or equal to 0.02g shall be restored to operable status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and a channel calibration performed within 5 days following the seismic event. Data shall be retrieved from actuated instruments and analyzed to determine the magnitude of the vibratory ground motion. A Special Report shall be prepared and submitted to the NRC within 10 days describing the magnitude, frequency spectrum, and resultant effect upon unit features important to safety.
Bases for the Current Reauirement Technical Specification Bases Section 3/4.3.7.2 states, "The operability of the seismic monitoring instrumentation ensures that sufficient capability is available to promptly determine the magnitude of a seismic event and evaluate the response of those features important to safety. This capability is required to permit comparison of the measured response is dat used in the design basis for the unit. This instrumentation is consistent with the recommendations of Regulatory Guide 1.12, " Instrumentation for Earthquakes", April 1974."
A-3
ATTACHMENT A DESCRIPTION OF SAFETY ANALYSIS OF THE PROPOSED CHANGES ,
I l
Description of the Need for Amendina the Technical Specification The existing time-history accelerographs (accelerometers) are being replaced with newer models, as described above. The rew models have a wider frequency range than the existing models. This will affect the " Measurement Range" column of Table 3.3.7.2-1. Item 4a of Tables 3.3.7.2-1 and 4.3.7.2-1, " Terra Technology Digital Cassette with playback feature", is being removed from Panel 0PA11J. Therefore, l Tables 3.3.7.2-1 and 4.3.7.2-1, in their present form, will not accurately represent the seismic monitoring instrumentation as replaced by Modification M01-1-9400128.
Description of the Amended Technical Specification Reauirement Technical Specification 3/4.3.7.2, including Tables 3.3.7.2-1 and 4.3.7.2-1, and Bases Section 3/4.3.7.2, will be relocated from the Technical Specifications to the UFSAR and Administrative Technical Requirements (ATR). The surveillance requirements will be described in the UFSAR in section 3.7.4 and a list of the seismic monitoring i instruments will be added to the UFSAR as Table 3.7-11. The Limiting Condition for Operation (LCO) requirement specified in Section 3.3.7.2.a (to prepare and submit a l Special Report to the NRC within 10 days of the seismic monitoring instrumentation i being inoperable for more than 30 days) will not be included in the ATR. The ATR tables will be revised when the seismic monitoring instrumentation is replaced by ;
Modification M01-1-9400128, under 10CFR50.59, after approval of this request for i amendment.
Bases Section 3/4.3.7.2 is currently titled in error as Section '3.4.3.7.2'in both the Unit 1 and Unit 2 Technical Specifications. An administrative change will be made to correct this error and this section will be indicated as ' Deleted' in the amendment.
Bases for the Amended Technical Specification Reauest NRC Generic Letter 95-10 lists four criteria developed by the NRC to determine which of the design conditions and associated surveillances should be located in the Technical Specifications as limiting conditions for operation. Generic Letter 95-10 states, "The Commission's Final Policy Statement and documentation related to the A-4
ATTACHMENT A DESCRIPTION OF SAFETY ANALYSIS OF THE PROPOSED CHANGES revision of 10 CFR 50.36 acknowledged that implementation of these criteria may cause some requirements presently in Technical Specifications to be moved out of existing Technical Specifications to documents and programs controlled by licensees."
The seismic monitoring insuumentation wcs among the candidates listed for relocation to licensee-controlled documents.
The Seismic Monitoring Instrumentation provides information only and is not considered in any design basis accident or transient. It does provide information regarding seismic activity during a seismic event. However, the evaluation summarized in NEDO-31466 determined the loss of this instrumentation to be a non-aignificant risk contributor to core damage frequency and offsite release. Therefore, 4
the requirements specified in current Specification 3/4.3.7.2, Table 3.3.7.2-1, Table 4.3.7.2-1, and Bases Section 3/4.3.7.2 did not satisfy the NRC Policy Statement
, Technical Specification Criteria to the LaSalle Technical Specifications and wi!! be relocated to plant documents controlled in accordance with 10 CFR 50 59 The LCO requirement specified in Section 3.3.7.2.a (to prepare and submit r, Special Report to the NRC within 10 days of the seismic monitoring instrumentstion being inoperable for more than 30 days) is not required to be relocated to the ATR since the Technical Specification Special Report requirements are only applicable to the LCOs.
Schedule i Comed has requested NRC approval of this amendment request within approximately six months. There are no specific schedule requirements associated with this amendment proposal. This amendment will be implemented within 90 days of issuance of the amendment.
a A-5