05000317/LER-1981-055-03, /03L-0:on 810701,pressurizer Pressure Channel 2E & Subcooled Margin Monitor 11 Removed from Svc & Reactor Protection Sys Channel B Trip Units Bypassed to Check Deviation Between Channels.Caused by Instrument Drift

From kanterella
(Redirected from ML20010A393)
Jump to navigation Jump to search
/03L-0:on 810701,pressurizer Pressure Channel 2E & Subcooled Margin Monitor 11 Removed from Svc & Reactor Protection Sys Channel B Trip Units Bypassed to Check Deviation Between Channels.Caused by Instrument Drift
ML20010A393
Person / Time
Site: Calvert Cliffs 
Issue date: 07/31/1981
From: Lagiewski J, Rizzo P
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20010A391 List:
References
LER-81-055-03L, LER-81-55-3L, NUDOCS 8108110389
Download: ML20010A393 (2)


LER-1981-055, /03L-0:on 810701,pressurizer Pressure Channel 2E & Subcooled Margin Monitor 11 Removed from Svc & Reactor Protection Sys Channel B Trip Units Bypassed to Check Deviation Between Channels.Caused by Instrument Drift
Event date:
Report date:
3171981055R03 - NRC Website

text

NRC FORM 366 U. S. NUCLEAR REGULATORY COMMISSION (7 77)

LICEf4SEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

lo li l di D l C l C l N I 1 ]@l 0 l 0 l - l 010 l 0 l 010 l-l 0 l 0 l@[ 4 l1 l1 l1 l 1 l@l l

l@

7 8 9 LICENSEE CODE 14 LICENSE NUMBER 25 26 LICENSE TYPE JO

$7 CAT 58 CON'T IoIiI 3$n$ l L l@[0j, 510 l 0 l 0 l 3 l 1 17 l@l 0 l 7 l 0 l1 l 8 l 1 l@l0 l 713 l 1 l 8 l 1 l@

7 8

60 61 DOCK ET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h lo [2l l At 0750 and 0845 ESFAS Ch ZE Pressurizer Pressure (Pzr Press) and 11 Sub-1 io i3i l cooled Margin Monitor were removed from se.vice and RPS Ch B trip units l

1O i4 l l for Hi Pzr Press and Thermal Margin / Low Pressure were bypassed to inves-1 iO isi l tigate a >.16 volt deviation between channels (T.S. 3.3.2.1, 3.3.1.1, 1

0 6 l

3.3.3.6).

All instruments were returned to service at 1445. On 7-9-81 l

l 0 l 71 l the isolating transmitter was adjusted and the loop checked satisfac-1 iOiRi i torily. All redundant channels remained operable during this event.

I 80 7

8 9 C DE CODE SUBCO E COMPONENT CODE SUBC DE S

ODE lolol l I I A l@ [ E_j@ [X_J @ II lN l S lT lR lU l@ l X l@ [Z_j @

7 8-9 10 11 12 13 18 19 20 SEQUENTI AL OCCURRENCE REPORT REVISION L E R RO EVENT YE AR REPORT NO.

CODE TYPE N O.

@ RgPg l218 l1 l l-l 10 l 5 l 5 l y

l 0l 3l lLl 9

[0j

??

23 24 26 27 28 29 30 31 32 TAKEN A ON ON PL N ET HOURS 22 SUB IT FOR B.

SUPPLI E R MAN FAC URER l E l@[Zj@

[Z j@

lZl@

l 0101010 l [Y_j @

lY l@

l Ll@

lRl313l5l@

33 34 35_

36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h 111011 Narra.' rance outout of isolatine transmitter 1-PY-102B (RIS #XSC-1302-I [i li l l 80618) had drif ted low by an amount equivalent to 35 psi. On 7-1-81.

I i 7 l

Ch B High Pressure Trip and Pre-trip setpoints were lowered to account l

lii3ll for the signal offset. On 7-9-81, the PY and setpoints were readjusted.

l i 4 i

No preventive action is deemed necessary as this is the first such event.

l 80 7

8 9 ST 15

% POW'R OTHER STATUS disco RY DISDOVERY DESCRIPTION IiISI LEj @ l110l0l@l NA l

l A l@l Operator Observation l

A TIVITY CO TENT RELE ASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELE ASE Iil6I Llj @ LIJ @ l NA I

l NA l

7 8 9 10 11 44 45 80 PERSONNEL E XPOSURES NUMBER TYPE D E SCRIP TION l

IWil l 01 Ol 01@l ZI@l NA PERSONNE t INJURIES NUYUER DESCRIP TION lOl01Ol@l NA J

i a 80 J

H 9 11 12 T PE E5CF PTON I

LzJ@l NA i o I 81 0389 810731

""C # ""

issuf o@OEscRiPT,08 @

PUBLI TY PDR ADOOK 05000317 [yj l

NA FDR l

l l l l l l l l l 1 LL] !

6 2 n 68 69 BO. ;

7 8 9 to

. S. Lagiewski/P. G. Rizzo (301) 269-4747/4786

,g gy, ;

NAME OF PREPARER

i r

LER No.

81-55/3L DOCKET NO.

50-317 LICENSE NO.

DPR-53 EVENT DATE 07-01-81 REPORT DATE 07-31-81 ATTACHMENT EVENT DESCRIPTION AND PROBABLE CONSEQUENCES (CONT'D)

At 0750, during normal operation, ESFAS Channel "ZE" Pressurizer Pressure (Pzr.

Press.) was removed from service to investigate a >.16 volt deviation between channels (T.S. 3.3.2.1). At 0845, RPS Channel "B" trip units for Hi Pressurizer-Pressure and Thermal Margin / Low Pressure were bypassed and #11 Subcooled Margin Monitor placed out of service for additional troubleshooting (T.S. 3.3.1.1 and 3.3.3.6). It was surmised that the Pressurizer Pressure Transmitter had zero l

shif ted, therefore, the Pressurizer Pressure Hi trip setpoint was lowered 35 psi as an interim measure until the transmitter could be checked.- All instruments were -

1 returned to service at 1445. On 7-9-81, during the next outage, the Pressurizer Pressure Transmitter was checked and found to be in calibration. Upon further investigation it was found that the E/E isolator (1-PY-102-B) was out of adjustment. Span and zero adjustments were made, the loop checked l

satisfactorily, and all instruments returned to service. The Hi Pressurizer Pressure trip setpoint was returned to normal on 7-11-81. ~ All redundant channels remained operable during this event, however, #12 Subcooled Margin Monitor remained out of service. This is not a repetitive event.

t I