05000348/LER-1981-042-03, /03L-0:on 810610,pump Supplying Containment Atmosphere Particulate & Gaseous Radioactivity Monitoring Sys Failed to Start.Caused by Filter Paper Not Advancing Due to Paper Drive Malfunction.Drive Mechanism Adjusted

From kanterella
(Redirected from ML20009F914)
Jump to navigation Jump to search
/03L-0:on 810610,pump Supplying Containment Atmosphere Particulate & Gaseous Radioactivity Monitoring Sys Failed to Start.Caused by Filter Paper Not Advancing Due to Paper Drive Malfunction.Drive Mechanism Adjusted
ML20009F914
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 07/01/1981
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20009F907 List:
References
LER-81-042-03L, LER-81-42-3L, NUDOCS 8108030161
Download: ML20009F914 (1)


LER-1981-042, /03L-0:on 810610,pump Supplying Containment Atmosphere Particulate & Gaseous Radioactivity Monitoring Sys Failed to Start.Caused by Filter Paper Not Advancing Due to Paper Drive Malfunction.Drive Mechanism Adjusted
Event date:
Report date:
3481981042R03 - NRC Website

text

y,~dCNTT,CL BLCCK: [ l l

l l

l l

(PLEASE PRINT CR TYPE ALL REQUIRED INFORMATIONI

.f S

o 1il l A lL lJ lM lF l1l@l O! 0l -l 0 l 0 l 0 l 0 l 0 xl-l0 l0 l@l 4 l 1 l 1 l 1 l 1 l@l l

l@

S 9 UCENSEE CCCE 14 15 uCENSE NUMBED 25 26 UCENSE TY;E D 57 CAT $3 ft Sbc LLRl 0 l 5 ! 0 l 0 10 l 3 l4 l8 @l0l611 l0 l8 l1 @l0l7l0Il18 II lh 60 63 CCCKET NUMagR 6a 69 EV ENT CATE 74 75 REPORT CATE 30 EVENT DESCR8"TlCN AND PROBABLE CONSECUENCES h

,oi2l lAt 0935 on 6/10/81, the containment atmosphere particulate and gaseous radioactivity l

o63l l monitoring systems (Rll and R12 respectively) were declared inoperable when the pump l

$364; l supplying the systems would not start due to filter paper not advancing.

Tech. Spec.

l 0,3j ;3.4.6.1 requires Ril and R12 to be operabic. Tech. Spec. 3.4.6.1 action statement re-l 1otsl l cuirements were met.

A similar occurrence was reported in LER 80-066/03L-0.

Health /

l 9 o i 7_) l Safety of the public was not affected.

l lois!l l

80 7

5 9 SYSTEM

CAUSE

CAUSE COMP.

VALVE CCCE CCCE SUSCCCE COMPCNENT CCCE SU8CCCE SUSCCCE lcIsl lB lB lh lE lh l Blh lF lI lL lT lE l R lh l Zl@ l Z l @

9 10 11 12 13 18 19 20 SECUENTIAL CCCURRENCE REFORT REVISION LER EVENT Y E A R R EPCRT NO..

CCCE TYPE N O.

h gg/RO l8l1l l-l l0 14 l2l d

l0l3l lLl l-l l 0l 21 22 23 24 26 27 2S 29 30 31 32 N A C

C P T

V HCURS S SMt FOR 8.

ppt. ER MA UF RER lE!@ d @

lZl@

l Zl@

l 01 0! 0l 0l l Nl@ 'l Nlg {@

l C. l 5 l 1 l 8 lQ 33 34 05 OS 37 40

<1 42 43 44 47 CAUSE C'ESCRIPTICN ANC CCRRECTIVE ACTICNS h l1 lollThe filter paper would not advance due to the paper. drive not functioning properly. The {

,l3 iil [ drive mechanism was adjusted and Rll and R12 were returned to service at 1500 on 6/10/81. (

l Subsequently the drive mechanism was modified to prevent recurrence.

,,,,i it 131 I l

li la I I l

7 8 9 80 ST

% PCWER OTHER SrATUS 015 C RY CISCOVERY CESCRIPTION I1 15 l l E l@ l 1l 0 l 0 l@l NA

]

l A l@l Operator Observation

}

8

' dnv1TY C$ TENT P:ELEASEC CF aELEASE AMOUNT CF ACTIVtTY LCCATIC'N CF RELEASE NA l

l NA l

I1 16 l l 2 l h l 7. !hl 7

a 9 10 11 44 45 80 PERSONNEL EXPCSURES NUMSER TYPE OESCRIPTICN j t i 7 l l 0 l 0 l 0 l@l Z l@l NA l

PERSONNEI.'1NJU' ES I

NUMBER O ESCRIPTICN NA l

jf la] l 010 l 0 l@l 7

1 9 11 10 80

' LCS3 CF CR CAMAGE TO FACluTV TYPti CESCRIPTION Im s IZl@l l

NA 7

8 9 to 80 PU8uCITY 8108030161 810701 NRC USE CNLY ISSUED PDR ADOCK 05000348 i : l o l W@CESCRIPTtCN PDR l

l;ll lll[ ; Ill l l

NA S

7 g 9 11 68 69 80 g (205) 899-5 j

IJ. G. Hairst'on, III

- PHONE:

NAME CF PREP ARER