05000348/LER-2006-001, Regarding Security Computer Access Control Software Deficiency

From kanterella
(Redirected from 05000348/LER-2006-001)
Jump to navigation Jump to search
Regarding Security Computer Access Control Software Deficiency
ML061110035
Person / Time
Site: Farley  
Issue date: 04/20/2006
From: Stinson L
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-06-0808 LER 06-001-00
Download: ML061110035 (4)


LER-2006-001, Regarding Security Computer Access Control Software Deficiency
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(v), Loss of Safety Function
3482006001R00 - NRC Website

text

1. M. Stinson (Mike)

Southern Nuclear Vice President Operating Company, Inc.

40 lnverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.5181 Fax 205.992.0341 A p r i l 20, 2006 Docket Nos.:

50-348 50-364 COMPANY Energy to Serve Your World' U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Joseph M. Farley Nuclear Plant - Units land 2 Licensee Event Report 2006-001 -00 Security Computer Access Control Software Deficiency Ladies and Gentlemen:

Joseph M. Farley Nuclear Plant Units 1 and 2 Licensee Event Report (LER) No. 2006-001 -00 is being submitted in accordance with 10 CFR 73.71 (a)(4) and 10 CFR Part 73 Appendix G (I)(c).

This letter contains no NRC commitments. If you have any questions, please advise.

Sincerely, L. M. Stinson Enclosure: Licensee Event Report 2006-001 -00 cc:

Southern Nuclear Operating Company Mr. J. T. Gasser, Executive Vice President Mr. J. R. Johnson, General Manager - Plant Farley RTYPE: CFA04.054; LC# 14429 U. S. Nuclear Regulatory Commission Dr. W. D. Travers, Regional Administrator Mr. R. E. Martin, NRR Project Manager - Farley Mr. C. A. Patterson, Senior Resident Inspector - Farley

NRC FORM 366 (6-2004)

PRINTED ON RECYCLED PAPER NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION (6-2004)

LICENSEE EVENT REPORT (LER)

(See reverse for required number of digitslcharacters for each block)

1. FACILITY NAME Joseph M. Farley Nuclear Plant - Unit 1 APPROVED BY OMB: NO. 3150-0104 EXPIRES: 06/3012007

, the NRC may not conduct or sponsor, and a person is not requ~red to respond to, the information collection.

2. DOCKET NUMBER 05000 348
4. TITLE Security Computer Access Control Software Deficiency
3. PAGE 1 OF 3
8. OTHER FACILITIES INVOLVED
9. OPERATING MODE 1
10. POWER LEVEL 100 FACILITY NAME Farley Unit 2 FACILITY NAME
7. REPORT DATE
5. EVENT DATE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFRS: (Check all that apply) 20.2201(b) 20.2203(a)(3)(i) 50.73(a)(2)(i)(C) 50.73(a)(2)(vii) 20.2201(d) 20.2203(a)(3)(ii) 50,73(a)(2)(ii)(A) 50.73(a)(2)(viii)(A) 20.2203(a)(l) 20.2203(a)(4) 50.73(a)(2)(ii)(B) 50.73(a)(2)(viii)(B) 20.2203(a)(2)(i) 50.36(c)(l )(i)(A) 50.73(a)(2)(iii) 50.73(a)(2)(ix)(A) 20.2203(a)(2)(ii) 50,36(c)(l)(ii)(A) 50.73(a)(2)(iv)(A) 50.73(a)(2)(x) 20.2203(a)(2)(iii) 50.36(~)(2) 50.73(a)(2)(v)(A) iXI 73.71(a)(4) 20.2203(a)(2)(iv) 50.46(a)(3)(ii) 50.73(a)(2)(v)(B) 73.71(a)(5) 20.2203(a)(2)(v) 50.73(a)(2)(i)(A) 50.73(4(2)(v)(C)

OTHER 20.2203(a)(2)(vi) 50.73(a)(2)(i)(B) 50.73(a)(2)(v)(D)

Specify in Abstract below or in =

(If more space is required, use additional copies of NRC Form 366A) (17)

I

Safety Assessment

A review of the VA door logs for access by the individual involved showed that he had only entered the VA for very short periods, validating that his VA entries were for the legitimate purpose of obtaining keys to the mobile crane he was to operate.

I A review of all active badges identified no badge set for more access than was intended (other than the individual's badge that triggered this investigation).

All personnel granted any PA or VA access have passed Unescorted Access Authorization. However, they are only administratively cleared to enter specific areas based on job need. Therefore, this event did not allow anyone without Unescorted Access Authorization to enter any Vital Area of the plant. A three year review was conducted of all badges incorrectly assigned wrong access levels by the computer and no other entry into an area not administratively cleared occurred.

Therefore, this event did not result in anyone without Unescorted Access Authorization entering the Protected Area or Vital Area.

I

Corrective Action

I With vendor assistance an enhanced procedure for setting badge access was developed and implemented on March 16, 2006 to prevent incorrect assignment of access levels.

I The vendor developed a software patch that was installed and tested satisfactorily on April 5, 2006.

I

Additional Information

There have been no similar LERs in the past two years.

I NRC FORM 366 (7-2001)