05000311/LER-1981-044-04, /04T:on 810707,contamination of Onsite Storage Area Ten Times Normal Background Reading Discovered Where Old Spent Fuel Storage Racks Had Been Stored.Caused by Rinsing of Racks & High Ambient Temps

From kanterella
(Redirected from ML20009E851)
Jump to navigation Jump to search
/04T:on 810707,contamination of Onsite Storage Area Ten Times Normal Background Reading Discovered Where Old Spent Fuel Storage Racks Had Been Stored.Caused by Rinsing of Racks & High Ambient Temps
ML20009E851
Person / Time
Site: Salem 
Issue date: 07/20/1981
From: Espey J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20009E846 List:
References
LER-81-044-04T, LER-81-44-4T, NUDOCS 8107280487
Download: ML20009E851 (1)


LER-1981-044, /04T:on 810707,contamination of Onsite Storage Area Ten Times Normal Background Reading Discovered Where Old Spent Fuel Storage Racks Had Been Stored.Caused by Rinsing of Racks & High Ambient Temps
Event date:
Report date:
3111981044R04 - NRC Website

text

C RC F E M 366 (7 77)

LICENSEE EVENT REPORT

~

CONTGOL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPE ALL Cetus;ED INFOIMATIONI i

e M lN l J l S lG lS l 2 l@15 o l o l -l 0 l 0 l 0 l 0 l 0 l - l 0 l 0 l@364l1l1l1l1l@l l

l@

7 8 9 LICENSEE CODE to LICENSE NLMBER 25 1,8 CENSE TYPE JO 67 CAT 68

  • COffT A

50"C L2J@l 01 s101 0101 31 il il@l 01710 I 7 I e I @74l nl 717 hinIil@

7 8

60 41 DOCKET NUMBER S

89 EVENT DATE 75 REPORT DATE 80 ITT n i Inadvertent contamination of an on h EVENT DESCRIPTION AND PROB AdL'E CONSEQUENCES site storage area in excess of 10 times the j

normal background reading was discovered in the area where old spent fuel storage l

o 3 l No release of l

ITTT1 I racks had been stored while awaiting shipment to a disposal site.

ITTTl I contamination was made to the off-site environment.

l i

L212_Il l

10171 I J

10181 l s0 SYSTEM

CAUSE

CAUSE COMP.

VALVE COCE COOE SUSCODE COMPONENT CODE SugCODE SU8 CODE l0l9l l Z l Z l@

lZlZlZlZlZlZl@

Q 7

8 9

to 11 12 1J 10 19 20 SE QUE NTI AL OCCU R R E NCE REPORT RE VIS'ON EVENTYEAR REPORT NO.

COCE TYPE No.

O,"LER ROl218 l1 l l-l l0 l4 l4 l d

l0 l4 l y

b W

l Ug E

22 23 24 26 27 N

3 30 31 32 K N AC ON ON PL NT MET HOUR 5 22 58 i FO S.

SUPPLI MAN ACTUREPZ@

l L"J@l."J@

Izl@

tzJ@

loIolol I

W@

I"I@

l z i@

l ZI ZI zi I

34 3b 36 37 40 el 42 43 44 ay 33 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h Ii IO 1 l The rinsing of the old spent fuel storage racks with the normally acidic rainfall, l

g i along with the higher ambient temperatures caused some previously fixed contami-l gl nation to wash into the ground.

contaminated dirt and stones have been removed and l l

Pe'sonnel I

l g i are stored in sealed drums while awaiting shipment to a burial site.

r l

l gl have been counseled in the proper methods of radioactive material storage.

I so i

e 9 STA 5

% POWER OTHERSTATUS i50 RY Dl5COVERY DESCRIPTION [1_l J [Gj@ l0 l 0 l 0 lhl N/A l

[CJhl Yard Survey l

487 viTY cO0 TENT RELE ASE AMOUNT OF ACTIVITY LOC ATION OF RELE ASE W y @D OF RELE ASE[p J@l 1000 ccPM co l

l Sterage Area l

7 8 9 to 11 44 45 30 PERSONNEL EXPOSURES NUMBER TYPE DE SCRIPTION l

l d O!0l@l ljhl NA 1 7

,ERSO~~El'i~;uLs oESCR:,TiO~@

NuM.ER I

d 0l Olhl 1 H NA 80 7

A 9 11 12 l

LOS$ OF OR DauAGE TO FACILITY TYPE DESCR8PT80N l

hl 1 9 NA 80 7

8 9 10 2 l O l ly_,J@ DESCRIPTION I

IIIIIIIIIIII15 ISSUED l

NA es s9 so.

s9 to J. J. Espey 609-935-0998 8107280487'8T 'f5d"" ~~