| 05000249/LER-1981-001, Has Been Cancelled | Has Been Cancelled | |
| 05000010/LER-1981-001-03, /03X-1:on 801210,radwaste Storage Tank Sampling Frequency Failed to Meet Tech Spec Requirements.Caused by Personnel Failure to Follow Procedures.Personnel Reinstructed | /03X-1:on 801210,radwaste Storage Tank Sampling Frequency Failed to Meet Tech Spec Requirements.Caused by Personnel Failure to Follow Procedures.Personnel Reinstructed | |
| 05000010/LER-1981-001, Forwards LER 81-001/03X-1 | Forwards LER 81-001/03X-1 | |
| 05000249/LER-1981-003-03, /03L-0:on 810120,Model 288 Differential Pressure Indicating switch,3-1349B,tripped Above Tech Spec Limit. Caused by Instrument Drift.Switch Readjusted & Repeatability Verified | /03L-0:on 810120,Model 288 Differential Pressure Indicating switch,3-1349B,tripped Above Tech Spec Limit. Caused by Instrument Drift.Switch Readjusted & Repeatability Verified | |
| 05000249/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000010/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000237/LER-1981-005, Forwards Updated LER 81-005/03X-L.Deviation Rept Encl | Forwards Updated LER 81-005/03X-L.Deviation Rept Encl | |
| 05000237/LER-1981-005-03, During Local Leak Rate Testing,Measured Leakage of Single Isolation Valve Exceeded Tech Specs.Caused by Normal Deterioration of Valve Seat. Valve Replaced | During Local Leak Rate Testing,Measured Leakage of Single Isolation Valve Exceeded Tech Specs.Caused by Normal Deterioration of Valve Seat. Valve Replaced | |
| 05000237/LER-1981-006, Forwards Updated LER 81-006/01X-1 | Forwards Updated LER 81-006/01X-1 | |
| 05000237/LER-1981-006-01, Excessive Leakage Indicated Various Penetrations in Feedwater Check Valves. Caused by Cracked O Ring & Worn Swing Pins.Valves Repaired & Broken Components Replaced | Excessive Leakage Indicated Various Penetrations in Feedwater Check Valves. Caused by Cracked O Ring & Worn Swing Pins.Valves Repaired & Broken Components Replaced | |
| 05000237/LER-1981-007-03, /03L-0:on 810122,temp Switch TS 2-261-18D Failed to Trip.Caused by Fill Matl Leakage Due to Broken Capillary Tube Close to Sensing Bulb.Broken Switch Replaced W/New Calibr Switch | /03L-0:on 810122,temp Switch TS 2-261-18D Failed to Trip.Caused by Fill Matl Leakage Due to Broken Capillary Tube Close to Sensing Bulb.Broken Switch Replaced W/New Calibr Switch | |
| 05000237/LER-1981-007, /03L for Dresden, Unit 2 Re While Conducting Steam Line Area Temperature Switch Calibration Surveillance, Temperature Switch TS 2-261-180 Failed to Trip | /03L for Dresden, Unit 2 Re While Conducting Steam Line Area Temperature Switch Calibration Surveillance, Temperature Switch TS 2-261-180 Failed to Trip | |
| 05000237/LER-1981-011-03, L-0 for Dresden, Unit 2 Re Observed Inadequacies in the Implementation of Administrative or Procedural Controls Which Threaten to Cause Reduction of Degree of Redundancy Provided in Reactor Protection Systems or Engineered S | L-0 for Dresden, Unit 2 Re Observed Inadequacies in the Implementation of Administrative or Procedural Controls Which Threaten to Cause Reduction of Degree of Redundancy Provided in Reactor Protection Systems or Engineered Safety Feature | |
| 05000249/LER-1981-014, Forwards LER 81-014/03L-0 | Forwards LER 81-014/03L-0 | |
| 05000249/LER-1981-014-03, /03L-0:on 810616,during Scram Air Sys Header Pressure Switch Calibr,Pressure Switches 3-302-99A & B Actuated W/Setpoint Lower than Required.Caused by Instrument Setpoint Drift.Switches Reset | /03L-0:on 810616,during Scram Air Sys Header Pressure Switch Calibr,Pressure Switches 3-302-99A & B Actuated W/Setpoint Lower than Required.Caused by Instrument Setpoint Drift.Switches Reset | |
| 05000237/LER-1981-015, /03L-0 for Dresden, Unit 2 Re the Fire Marshall Discovered That the Heat Detectors Were Not Functionally Tested within the 6 Month Interval Required by Tech. Spec. 4.12.A.1 | /03L-0 for Dresden, Unit 2 Re the Fire Marshall Discovered That the Heat Detectors Were Not Functionally Tested within the 6 Month Interval Required by Tech. Spec. 4.12.A.1 | |
| 05000249/LER-1981-015-03, /03L-0:on 810618,switch Actuated at 32.8 Inches During Calibr of Isolation Condenser Steam/Condensate Line High Flow.Caused by Instrument Drift.Switch Reset | /03L-0:on 810618,switch Actuated at 32.8 Inches During Calibr of Isolation Condenser Steam/Condensate Line High Flow.Caused by Instrument Drift.Switch Reset | |
| 05000249/LER-1981-015, Forwards LER 81-015/03L-0 | Forwards LER 81-015/03L-0 | |
| 05000237/LER-1981-016, Forwards LER 81-016/03X-1 | Forwards LER 81-016/03X-1 | |
| 05000237/LER-1981-016-03, /03X-1:on 810408,noted That off-stream Liquid Effluent Monitor Had Not Been Functionally Tested on Monthly Basis.Caused by Deletion of Surveillance After Replacing on-stream Monitor w/off-stream Monitor | /03X-1:on 810408,noted That off-stream Liquid Effluent Monitor Had Not Been Functionally Tested on Monthly Basis.Caused by Deletion of Surveillance After Replacing on-stream Monitor w/off-stream Monitor | |
| 05000249/LER-1981-016, Forwards LER 81-016/03L-0 | Forwards LER 81-016/03L-0 | |
| 05000249/LER-1981-016-03, /03L-0:on 810618,water Level Instrument Surveillance Found LIS 263-57A Tripping Above Tech Spec Levels for Low Level Scram & Low Water Level Isolation. Caused by Instrument Setpoint Drift.Setpoint Adjusted | /03L-0:on 810618,water Level Instrument Surveillance Found LIS 263-57A Tripping Above Tech Spec Levels for Low Level Scram & Low Water Level Isolation. Caused by Instrument Setpoint Drift.Setpoint Adjusted | |
| 05000249/LER-1981-017, Forwards Updated LER 81-017/03X-1 | Forwards Updated LER 81-017/03X-1 | |
| 05000249/LER-1981-017-03, 3B Motor Generator Set Undervoltage Relay Failed to Trip on Undervoltage Signal. Caused by Sticking Relay Tripping Device.Tripping Device Cleaned,Lubed & Placed Back in Svc | 3B Motor Generator Set Undervoltage Relay Failed to Trip on Undervoltage Signal. Caused by Sticking Relay Tripping Device.Tripping Device Cleaned,Lubed & Placed Back in Svc | |
| 05000237/LER-1981-017-03, /03L-0:on 810408,QA Audit Discovered That Temp of Cells Adjacent to Pilot Cell Had Not Been Taken,Per Tech Specs.Caused by Inadvertent Oversight Due to Inadequate Procedures.Change Will Be Implemented by June 1981 | /03L-0:on 810408,QA Audit Discovered That Temp of Cells Adjacent to Pilot Cell Had Not Been Taken,Per Tech Specs.Caused by Inadvertent Oversight Due to Inadequate Procedures.Change Will Be Implemented by June 1981 | |
| 05000237/LER-1981-017, Forwards LER 81-017/03L-0 | Forwards LER 81-017/03L-0 | |
| 05000249/LER-1981-018, Forwards LER 81-018/03L-0 | Forwards LER 81-018/03L-0 | |
| 05000249/LER-1981-018-03, /03L-0:on 810619,LIS 263-72B Found Tripping Above Tech Spec Limit During Monthly Water Level ECCS Instrument Surveillance.Caused by Instrument Setpoint Drift.Setpoint Adjusted.Deviation Rept Encl | /03L-0:on 810619,LIS 263-72B Found Tripping Above Tech Spec Limit During Monthly Water Level ECCS Instrument Surveillance.Caused by Instrument Setpoint Drift.Setpoint Adjusted.Deviation Rept Encl | |
| 05000249/LER-1981-019-03, /03L-0:on 810821,main Steam Line High Flow Switches Dpis 3-261-2 & 3-261-2D Found Above Tech Spec Limits.Caused by Torque Shaft Gears Binding on Linkage Gears from Normal Wear & Filings Buildup.Gears Cleaned | /03L-0:on 810821,main Steam Line High Flow Switches Dpis 3-261-2 & 3-261-2D Found Above Tech Spec Limits.Caused by Torque Shaft Gears Binding on Linkage Gears from Normal Wear & Filings Buildup.Gears Cleaned | |
| 05000249/LER-1981-019, Forwards LER 81-019/03L-0 | Forwards LER 81-019/03L-0 | |
| 05000237/LER-1981-020-01, During ASME Hydrostatic Test,Water Observed Seeping from Cracks in 2.5-inch Rx Head Spray Line.Caused by Chloride Induced Stress Corrosion Cracking.Cracks Cut Out & Piping Replaced | During ASME Hydrostatic Test,Water Observed Seeping from Cracks in 2.5-inch Rx Head Spray Line.Caused by Chloride Induced Stress Corrosion Cracking.Cracks Cut Out & Piping Replaced | |
| 05000237/LER-1981-020, Forwards Updated LER 81-020/01X-1 | Forwards Updated LER 81-020/01X-1 | |
| 05000249/LER-1981-020, Is Canceled | Is Canceled | |
| 05000249/LER-1981-021-03, Pinhole Leak Found on Reactor Water Cleanup Line from Regenerative Heat Exchanger. Caused by Sensitization During Initial Welding.Other Internal Cracks Discovered.Heat Exchanger Loop Replaced | Pinhole Leak Found on Reactor Water Cleanup Line from Regenerative Heat Exchanger. Caused by Sensitization During Initial Welding.Other Internal Cracks Discovered.Heat Exchanger Loop Replaced | |
| 05000249/LER-1981-021, Forwards LER 81-021/03L-0 | Forwards LER 81-021/03L-0 | |
| 05000249/LER-1981-022, Forwards LER 81-022/03L-0 | Forwards LER 81-022/03L-0 | |
| 05000249/LER-1981-022-03, /03L-0:on 810902,vessel low-low Water Level Isolation Switch Had Setpoint of 116.8 Inches,Exceeding Tech Spec Limit.Caused by Instrument Setpoint Drift.Setpoint Adjusted | /03L-0:on 810902,vessel low-low Water Level Isolation Switch Had Setpoint of 116.8 Inches,Exceeding Tech Spec Limit.Caused by Instrument Setpoint Drift.Setpoint Adjusted | |
| 05000237/LER-1981-023, Forwards LER 81-023/03L-0 | Forwards LER 81-023/03L-0 | |
| 05000237/LER-1981-023-03, /03L-0:on 810511,while Running HPCI Pump Test, Operator Observed Torus Wide Range Level Instrument Reading 0 Inches & Narrow Range Level Instrument Reading Approx 2 Inches & Oscillating.Caused by Personnel Error | /03L-0:on 810511,while Running HPCI Pump Test, Operator Observed Torus Wide Range Level Instrument Reading 0 Inches & Narrow Range Level Instrument Reading Approx 2 Inches & Oscillating.Caused by Personnel Error | |
| 05000249/LER-1981-023-03, /03L-0:on 810904,while Conducting Quarterly Scram Discharge Vol Continuous Level Monitor Calibr Check,West & East Bank/East Transducer high-high Level Alarm Tripped. Caused by Setpoint Drift | /03L-0:on 810904,while Conducting Quarterly Scram Discharge Vol Continuous Level Monitor Calibr Check,West & East Bank/East Transducer high-high Level Alarm Tripped. Caused by Setpoint Drift | |
| 05000249/LER-1981-023, Forwards LER 81-023/03L-0 | Forwards LER 81-023/03L-0 | |
| 05000249/LER-1981-024-01, /01T-0:on 810914,ultrasonic Testing Revealed Water in Steam Supply Line to HPCI Turbine.Caused by Low Point in Horizontal Section of Pipe.Drain Line Installed in Low Point & Routed Back to Same Line at Lower Elevation | /01T-0:on 810914,ultrasonic Testing Revealed Water in Steam Supply Line to HPCI Turbine.Caused by Low Point in Horizontal Section of Pipe.Drain Line Installed in Low Point & Routed Back to Same Line at Lower Elevation | |
| 05000237/LER-1981-024-03, /03L-0:on 810513,monthly Surveillance for Standby Liquid Control Tank Sampling Found 3 Days Overdue.Caused by Lack of Personnel Attention.Personnel Admonished.Tank Sampled | /03L-0:on 810513,monthly Surveillance for Standby Liquid Control Tank Sampling Found 3 Days Overdue.Caused by Lack of Personnel Attention.Personnel Admonished.Tank Sampled | |
| 05000249/LER-1981-024, Forwards LER 81-024/01T-0 | Forwards LER 81-024/01T-0 | |
| 05000237/LER-1981-024, /03L-0 for Dresden, Unit 2 Re While Conducting Routine Review of Surveillance, It Was Found That the Monthly Surveillance Required by Tech. Spec. 4.4.c.1 for Standby Liquid Control Tank Sampling Was Three Days Overdue | /03L-0 for Dresden, Unit 2 Re While Conducting Routine Review of Surveillance, It Was Found That the Monthly Surveillance Required by Tech. Spec. 4.4.c.1 for Standby Liquid Control Tank Sampling Was Three Days Overdue | |
| 05000237/LER-1981-025, Forwards LER 81-025/03L-0 | Forwards LER 81-025/03L-0 | |
| 05000237/LER-1981-025-03, /03L-0:on 810518,during Plant Tour by Operations Personnel,Low Pressure Leg of Isolation Condenser Level Indication Found Valved Out.Probably Caused by Valve Not Being Reopened After Sampling.Valve Opened | /03L-0:on 810518,during Plant Tour by Operations Personnel,Low Pressure Leg of Isolation Condenser Level Indication Found Valved Out.Probably Caused by Valve Not Being Reopened After Sampling.Valve Opened | |
| 05000249/LER-1981-025-01, During Automatic Depressurization Sys Valve Operability Surveillance,B Electromatic Relief Valve Failed to Open at Rated Pressure. Caused by Excessive Leakage on Threads | During Automatic Depressurization Sys Valve Operability Surveillance,B Electromatic Relief Valve Failed to Open at Rated Pressure. Caused by Excessive Leakage on Threads | |
| 05000249/LER-1981-025, Forwards Updated LER 81-025/01X-1 | Forwards Updated LER 81-025/01X-1 | |
| 05000249/LER-1981-026-03, /03L-0:on 810915,while Shutting Down,Rod P-10 Showed Wrong Position on Rod Worth Minimizer.Caused by Several Diode Failures on Two Digital Output Printed Circuit Boards.Boards Removed,Repaired & Tested Satisfactorily | /03L-0:on 810915,while Shutting Down,Rod P-10 Showed Wrong Position on Rod Worth Minimizer.Caused by Several Diode Failures on Two Digital Output Printed Circuit Boards.Boards Removed,Repaired & Tested Satisfactorily | |