05000249/LER-2013-001, Regarding Secondary Containment Inoperable Due to Two Interlock Doors Being Open Simultaneously

From kanterella
(Redirected from 05000249/LER-2013-001)
Jump to navigation Jump to search
Regarding Secondary Containment Inoperable Due to Two Interlock Doors Being Open Simultaneously
ML14037A211
Person / Time
Site: Dresden 
Issue date: 01/27/2014
From: Marik S
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
SVPLTR 14-0006 LER 13-001-00
Download: ML14037A211 (4)


LER-2013-001, Regarding Secondary Containment Inoperable Due to Two Interlock Doors Being Open Simultaneously
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications
2492013001R00 - NRC Website

text

ADresden Nuclear Power Station EAelolnG nn 6500 North Dresden Road Exeon GenerationIL 0450 815-942-2920 Telephone www.exeloncorp.com 10 CFR 50.73 SVPLTR # 14-0006 January 27, 2014 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Dresden Nuclear Power Station Unit 3 Renewed Facility Operating License No. DPR-25 NRC Docket No 50-249

Subject:

Licensee Event Report 249/2013-001-00, Secondary Containment Inoperable Due to Two Interlock Doors Being Open Simultaneously Enclosed is Licensee Event Report 249/2013-001-00, "Secondary Containment Inoperable Due to Two Interlock Doors Being Open Simultaneously." This report describes an event which is being reported in accordance with 10 CFR 50.73(a)(2)(v)(C), any event or condition that could have prevented the fulfillment of the safety function of structures or systems that are needed to control the release of radioactive material.

There are no regulatory commitments contained in this submittal.

Should you have any questions concerning this letter, please contact Mr. Glen Morrow at (815) 416-2800.

Respectfully, Shane M. Marik Site Vice President Dresden Nuclear Power Station Enclosure: Licensee Event Report 249/2013-001-00 cc:

Regional Administrator - NRC Region 1it NRC Senior Resident Inspector - Dresden Nuclear Power Station

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 01/31/2017 (01-2014)

Estimated burden per response to comply with this mandatory collection request: 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />.

S

.Reported lessons leamed are incorporated into the licensing process and fed back to industry.

A,

Send comments regarding burden estimate to the FOIA, Privacy and Information Collections Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by

.'.. LIC"ENSEE EVENMT REPORT (LER)~

intemet e-mail to lnfoco*iects.Resource@nrc.gov, and to the Desk Officer, Office of Inforration and LICENS~EE. EVENTI REPORT (E

)

Regulatory Affairs, NEOB-10202, (3150-0104). Office of Management and Budget, Washington, DC (See Page 2 for required number of 20503. If a means used to impose an information collection does not display a currently valid OMB for each block) control number, the NRC may not conduct or sponsor, and a person is not required to respond to, digits/characters fthe information collection

3. PAGE Dresden Nuclear Power Station, Unit 3 05000249 1 OF 3
4. TITLE Secondary Containment Inoperable Due to Two Interlock Doors Being Open Simultaneously
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED MONTH DAY YEAR YEAR SEQUENTIAL REV MONTH DAY YEAR N/A 05000 O T MT E IFACILITY NAME DOCKET NUMBER 11 28 2013 2013
- 001 00 01 27 2014 N/A 05000
9. OPERATING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)

Ql 20.2201(b) 0 20.2203(a)(3)(i)

[0 50.73(a)(2)(i)(C)

[] 50.73(a)(2)(vii)

E 20.2201(d) 0 20.2203(a)(3)(ii) 0 50.73(a)(2)(ii)(A) 0 50.73(a)(2)(viii)(A) 20.2203(a)(1)

[3 20.2203(a)(4)

[I 50.73(a)(2)(ii)(B) 0 50.73(a)(2)(viii)(B) o 20.2203(a)(2)(i)

[0 50.36(c)(1)(i)(A) 03 50.73(a)(2)(iii)

[I 50.73(a)(2)(ix)(A)

10. POWER LEVEL El 20.2203(a)(2)(ii)

[3 50.36(c)(1)(ii)(A) 0l 50.73(a)(2)(iv)(A)

[I 50.73(a)(2)(x)

Ql 20.2203(a)(2)(iii) 0 50.36(c)(2) 0 50.73(a)(2)(v)(A)

[1 73.71(a)(4) 100 El 20.2203(a)(2)(iv) 0 50.46(a)(3)(ii) 0 50.73(a)(2)(v)(B)

[1 73.71 (a)(5)

El 20.2203(a)(2)(v) 0 50.73(a)(2)(i)(A)

[

50.73(a)(2)(v)(C)

E0 OTHER Ql 20.2203(a)(2)(vi) j[ 50.73(a)(2)(i)(B) 0[ 50.73(a)(2)(v)(D)

Specify in Abstract below or in I

PLANT AND SYSTEM IDENTIFICATION

Dresden Nuclear Power Station (DNPS) Unit 3 is a General Electric Company Boiling Water Reactor with a licensed maximum power level of 2957 megawatts thermal. The Energy Industry Identification System codes used in the text are identified as [XX].

A.

Plant Conditions Prior to Event:

Unit: 03 Event Date: 11-28-2013 Event Time: 0258 hours0.00299 days <br />0.0717 hours <br />4.265873e-4 weeks <br />9.8169e-5 months <br /> CST Reactor Mode: 1 Mode Name: Power Operation Power Level: 100 percent B.

Description of Event

On 11/28/13 a Radiation Protection Technician (RPT) and laborers went to the Unit 2 Secondary Containment [NG] X-Area (i.e., Main Steam Tunnel Area) to remove and demobilize the remaining lead blankets in the area. The RPT and laborers entered the Unit 2 X-Area by opening the outer door of the interlock that required an RP "R-Key' to open. The door was held open by the laborers while the RPT used his Dresden Station (DS) key to open the inner interlock door at the same time. The inner door seemed stuck closed to the RPT. He looked around and saw a manual button that defeats the interlock mechanism. The RPT pushed the button, and the inner door opened. The RPT and laborers entered the room and proceeded to remove and demobilize the lead.

Concurrent with the events taking place at the Unit 2 X-Area, the Unit 2 Control Room received alarm 902-4 F-19 on the X-Area interlock door. Operations sent an equipment operator into the field to investigate and found the RPT and laborers in the area removing lead blankets from the room. He notified the RPT that the control room had received an alarm for secondary containment. The RPT closed the doors and the alarm was reset.

This event is being reported in accordance with 10 CFR 50.73(a)(2)(v)(C), any event or condition that could have prevented the fulfillment of the safety function of structures or systems that are needed to control the release of radioactive material. At the time of the event, the requirements of Technical Specification 3.6.4.1 were not applicable to Unit 2 because Unit 2 was in Mode 4.

Therefore, this event is only reportable for Dresden Unit 3.

C.

Cause of Event

The cause of this event was determined to be a failure to recognize a hazard while proceeding in the face of uncertainty. Specifically, an RPT did not recognize that there was a change in plant conditions (i.e., the X-Area was restored to part of the Secondary Containment boundary) and decided that it was permissible to override the X-Area interlock doors by using an emergency manual push-button without first stopping to question when conditions were not as expected.

A contributing cause of this event was a lack of procedural guidance that would communicate to RP the restoration of the X-Area to service. The procedure required communications (i.e., Signoffs) to Operations and to Engineering. However, the procedure did not require RP to be notified of the restoration.

D.

Safety Analysis

The Secondary Containment interlock doors were open for approximately fifteen minutes. Based upon the number of individuals present at the interlock that were capable of closing the interlock, and that the Secondary Containment differential pressure remained negative during the course of this event, this event is of low safety significance.

E.

Corrective Actions

As a result of this event, the station has completed or is planning to complete the following:

1. Performance management of the RPT involved in this event has been completed.
2. A Stand-Down with the RP Department, discussing this event, was completed.
3. An action was created for each RP employee to review human performance procedures.
4. Conducted a discussion with RPTs on how the U2 X-Area interlock doors work in order to verify understanding of the door operations.
5. Established requirement for additional briefs for X-Area entries.
6. Add additional communications to the station procedure for removal and restoration of the X-Area from service.

F.

Previous Occurrences

The station did not find previous occurrences over the past two years that specifically related to an event where an individual manually defeated interlocks.

G.

Comoonent Failure Data:

N/A