ATTACHMENT TO LICENSE AMENDMENT NO. 165 TO FACILITY COMBINED LICENSE NO. NPF-92 DOCKET NO.52-026 Replace the following pages of the Facility Combined License No. NPF-92 with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.
Facility Combined License No. NPF-92 REMOVE INSERT 7 7 Appendix C to Facility Combined License No. NPF-92 REMOVE INSERT C-412 C-412 C-412a C-412a C-413 C-413 C-414 C-414 C-415 C-415 C-416 C-416 C-417 C-417 C-418 C-418 C-419 C-419 C-423 C-423 C-424 C-424 C-425 C-425 C-427 C-427 C-428 C-428
(7) Reporting Requirements (a) Within 30 days of a change to the initial test program described in UFSAR Section 14, Initial Test Program, made in accordance with 10 CFR 50.59 or in accordance with 10 CFR Part 52, Appendix D, Section VIII, Processes for Changes and Departures, SNC shall report the change to the Director of NRO, or the Directors designee, in accordance with 10 CFR 50.59(d).
(b) SNC shall report any violation of a requirement in Section 2.D.(3),
Section 2.D.(4), Section 2.D.(5), and Section 2.D.(6) of this license within 24 hours1 days <br />0.143 weeks <br />0.0329 months <br />. Initial notification shall be made to the NRC Operations Center in accordance with 10 CFR 50.72, with written follow up in accordance with 10 CFR 50.73.
(8) Incorporation The Technical Specifications, Environmental Protection Plan, and ITAAC in Appendices A, B, and C, respectively of this license, as revised through Amendment No. 165, are hereby incorporated into this license.
(9) Technical Specifications The technical specifications in Appendix A to this license become effective upon a Commission finding that the acceptance criteria in this license (ITAAC) are met in accordance with 10 CFR 52.103(g).
(10) Operational Program Implementation SNC shall implement the programs or portions of programs identified below, on or before the date SNC achieves the following milestones:
(a) Environmental Qualification Program implemented before initial fuel load; (b) Reactor Vessel Material Surveillance Program implemented before initial criticality; (c) Preservice Testing Program implemented before initial fuel load; (d) Containment Leakage Rate Testing Program implemented before initial fuel load; (e) Fire Protection Program
- 1. The fire protection measures in accordance with Regulatory Guide (RG) 1.189 for designated storage building areas (including adjacent fire areas that could affect the storage area) implemented before initial receipt 7 Amendment No. 165
Table 3.3-1 Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building (1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
(15)
Containment Building Internal Structure Shield Wall between Reactor Vessel Cavity and RCDT E-W wall parallel with column line 7 From 71'-6" to 83'-0" 3'-0"(10) Yes Room (Inside face is 3'-0" north of column line 7. Width of wall section with stated thickness is defined by inside wall of reactor vessel cavity.)
West Reactor Vessel Cavity Wall N-S wall parallel with column line N From 83'-0" to 98'-0" 7'-6"(10) Yes (Width of wall section with stated thickness is defined by inside wall of reactor vessel cavity.)
North Reactor Vessel Cavity Wall E-W wall parallel with column line 7 From 83'-0" to 98'-0" 9'-0"(10) Yes (Width of wall section with stated thickness is defined by inside wall of reactor vessel cavity.)
East Reactor Vessel Cavity Wall N-S wall parallel with column line N From 83'-0" to 98'-0" 7'-6"(10) Yes (Width of wall section with stated thickness is defined by inside wall of reactor vessel cavity.)
West Refueling Cavity Wall N-S wall parallel with column line N From 98'-0" to 135'-3" 4'-0" Yes North Refueling Cavity Wall E-W wall parallel with column line 7 From 98'-0" to 135'-3" 4'-0" Yes East Refueling Cavity Wall N-S wall parallel with column line N From 98'-0" to 135'-3" 4'-0" Yes South Refueling Cavity Wall E-W wall parallel with column line 7 From 98'-0" to 135'-3" 4'-0" Yes South wall of west steam generator compartment Not Applicable From 103'-0" to 153'-0" 2'-6" Yes West wall of west steam generator compartment N-S wall parallel with column line N From 103'-0" to 153'-0" 2'-6" Yes North wall of west steam generator compartment Not Applicable From 103'-0" to 153'-0" 2'-6" Yes C-412 Amendment No. 165
- 1. The column lines and floor elevations are identified and included on Figures 3.3-1 through 3.3-13.
- 2. These wall (and floor) thicknesses have a construction tolerance of +/- 1 inch, except as noted and for exterior walls below grade where the tolerance is +12 inches, - 1 inch. These tolerances are not applicable to the nuclear island basemat.
- 3. For walls that are part of structural modules, the concrete thickness also includes the steel face plates. Where faceplates with a nominal thickness of 0.5 inches are used in the construction of the wall modules, the wall thicknesses in this column apply. Where faceplates thicker than the nominal 0.5 inches are used in the construction of the structural wall modules, the wall thicknesses in the area of the thicker faceplates are greater than indicated in this column by the amount of faceplate thickness increase over the nominal 0.5 inches. Overlay plates are not considered part of the faceplates, and thus are not considered in the wall thicknesses identified in this column.
- 4. For floors with steel surface plates, the concrete thickness also includes the plate thickness.
- 5. Where a wall (or a floor) has openings, the concrete thickness does not apply at the opening.
- 6. The elevation ranges for the shield building items are rounded to the nearest inch.
- 7. The Wall or Section Description, Column Line information, and Floor Elevation or Elevation Ranges are provided as reference points to define the general location. The concrete thickness of an item intersecting other walls, roofs or floors at a designated location (e.g., column line) is not intended to be measured to the stated column line, but only to the point where the intersection occurs.
- 8. Where applicable, the upper wall portions extend to their associated roofs, which may vary in elevation, e.g., sloped roofs.
- 9. From one wall/floor section to another, the concrete thickness transitions from one thickness to another, consistent with the configurations in Figures 3.3-1 through 3.3-14.
- 10. This wall thickness has a tolerance of 1-5/8 inch.
- 11. This wall thickness has a tolerance of +4 inches, -1 inch above grade.
- 12. The concrete thickness is the total floor thickness, including the metal decking, where applicable.
- 13. The concrete in the kitchen and restroom areas is 2 inches thinner.
- 14. The 6-foot concrete thickness includes the thickness of the containment vessel bottom head in a local area at the center of containment.
- 15. Reconciliation of construction deviations in the nuclear island structures from the thickness and tolerances specified in this table is included in the reconciliation reports, and demonstrate that the as-built structures will withstand design basis loads without loss of structural integrity or safety functions and without impacting compliance with the radiation protection licensing basis, such as GDC 19, established radiological zoning and equipment qualification in accordance with ITAAC 3.3.00.02a.i.a, 3.3.00.02a.i.b, 3.3.00.02a.i.c, or 3.3.00.02a.i.d.
- 16. Construction deviations in the annex building from the thickness and tolerances specified in this table are evaluated in the thickness report to demonstrate that the as-built structures will withstand design basis loads without loss of structural integrity or safety functions and without impacting compliance with the radiation protection licensing basis, such as GDC 19, established radiological zoning and equipment qualification in accordance with ITAAC 3.3.00.02a.ii.e.
- 17. Construction deviations in the turbine building from the thickness and tolerances specified in this table are evaluated in the thickness report to demonstrate that the as-built structures will withstand design basis loads without loss of structural integrity or safety functions in accordance with ITAAC 3.3.00.02a.ii.f.
- 18. Nonconformances from the thicknesses and tolerances specified in Table 3.3-1 (i.e. out of tolerance conditions) are addressed under the 10 CFR Part 50, Appendix B process and subsequently are screened in accordance with the 10 CFR Part 52, Appendix D, Section VIII process, to ensure that the licensing basis is adequately maintained. Construction deviations will continue to be assessed against the licensing basis requirements and will be addressed in accordance with licensee procedures and regulatory requirements and, if applicable, a license amendment will be obtained prior to implementation of the change.
C-412a Amendment No. 165
Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building (1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
South wall of pressurizer compartment Not Applicable From 103'-0" to 153'-6" 2'-6" Yes West wall of pressurizer compartment N-S wall parallel with column line N From 107'-2" to 160'-0" 2'-6" Yes North wall of pressurizer compartment E-W wall parallel with column line 7 From 107'-2" to 160'-0" 2'-6" Yes East wall of pressurizer compartment N-S wall parallel with column line N From 118'-6" to 160'-0" 2'-6" Yes North-east wall of in-containment refueling water storage Parallel to column line N From 103'-0" to 135'-3" 2'-6" No tank West wall of in-containment refueling water storage tank Not applicable From 103'-0" to 135'-3" 5/8" steel plate with No stiffeners South wall of east steam generator compartment Not Applicable From 87'-6" to 153'-0" 2'-6" Yes East wall of east steam generator compartment N-S wall parallel with column line N From 94'-0" to 153'-0" 2'-6" Yes North wall of east steam generator compartment Not Applicable From 87'-6" to 153'-0" 2'-6" Yes with a 158'-0" portion Shield Building(6)(15)
Shield Building Cylinder Not Applicable From 100'-0" to 248'-6" 3'-0" (including Yes 3/4 inch thick min.
steel plate liner on each face on portion not protected by auxiliary building)
Air Inlet Not Applicable From 248'-6" to 251'-6" 3'-0" (including Yes 3/4 inch thick min.
steel plate liner on each face)
From 251'-6" to 254'-6" 3'-0" to 4'-6" Yes (including 1 inch thick steel plate liner on each face)
From 254'-6" to 266'-4" 4'-6" (including 1 inch Yes thick min. steel plate liner on each face)
Tension Ring Not Applicable From 266'-4" to 271'-6 (at top of 4'-6" (including Yes plate) 1-1/2 inch thick steel plate liner on each face)
C-413 Amendment No. 165
Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building(1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
Conical Roof Not Applicable From 271'-6" to 293'-9" 3'-0" (including Yes 1/2 inch thick min.
steel plate liner on bottom face, outside of PCS tank exterior wall)
PCS Tank External Cylindrical Wall Not Applicable From 293'-9" to 328'-9" 2'-0" Yes PCS Tank Internal Cylindrical Wall Not Applicable From 309'-4" to 329'-0" 1'-6" Yes PCS Tank Roof Not Applicable 328'-9" (Lowest) 329'-0" (Highest) 1'-3" No (14)
Nuclear Island Basemat Below shield building From 60'-6" to containment vessel 6'-0" to 22'-0" No or 82'-6" (varies)
Auxiliary Building Walls/Floors Radiologically Controlled(15)
Column Line 1 wall From I to N From 66'-6" to 100'-0" 3'-0" No Column Line 1 wall From I to 5'-7" west of K-2 From 100'-0" to 109'-3" 2'-3" Yes Column Line 1 wall From 5'-7" west of K-2 to N From 100'-0" to 109'-3" 3'-0" Yes Column Line 1 wall From I to 5'-6" east of L-2 From 109'-3" to 180'-0" 2'-3" Yes Column Line 1 wall From 5'-6" east of L-2 to N From 109'-3" to 125'-0" 3'-0" Yes Column Line 1 wall From 5'-6" east of L-2 to N From 125'-0" to 180'-0" 2'-3" Yes Column Line 2 wall From I to K-2 From 66'-6" to 135'-3" 2'-6" Yes Column Line 2 wall From K-2 to L-2 From 66'-6" to 135'-3" 5'-0" Yes Column Line 2 wall From L-2 to N From 82'-6" to 135'-3" 2'-6" Yes Column Line 2 wall From I to J-1 From 135'-3" to 153'-0" 2'-0" Yes Column Line 3 wall From J-1 to J-2 From 66'-6" to 82'-6" 2'-6" Yes Column Line 3 wall From J-1 to J-2 From 100'-0" to 135'-3" 2'-6" Yes Column Line 3 wall From J-2 to K-2 From 66'-6" to 135'-3" 2'-6" Yes Column Line 3 wall From K-2 to L-2 From 66'-6" to 92'-8 1/2" 2'-6" Yes Column Line 4 wall From I to J-1 From 66'-6" to 135'-3" 2'-6" Yes Column Line 4 wall From J-1 to J-2 From 66'-6" to 92'-6" 2'-6" Yes Column Line 4 wall From J-1 to J-2 From 107'-2" to 135'-3" 2'-6" Yes Column Line 4 wall From J-2 to K-2 From 66'-6" to 135'-3" 2'-6" Yes Column Line 4 wall From I to intersection with shield From 135'-3" to 180'-0" 2'-0" Yes building wall C-414 Amendment No. 165
Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building (1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
Column Line 5 wall From I to shield building; with From 66'-6" to 160'-6" 2'-0" Yes opening east of J-1 (below 107'-2" floor).
Wall, 17'-3" north of Column Line 7 From I to 8' east of J-1 From 66'-6" to 82'-6" 2'-0" Yes Wall, 10'-6" south of Column Line 7.3 From I to 5'-6"east of J-1 From 66'-6" to 82'-6" 2'-0" Yes Wall, 10'-6" south of Column Line 7.3 From I to just east of J From 82'-6" to 100'-0" 2'-0" Yes Column Line I wall From 1 to 4 From 66'-6" to 100'-0" 3'-0" No Column Line I wall From 4 to 16'-0" south of 5 From 66'-6" to 107'-2" 3'-0" No Column Line I wall From 16'-0" south of 5 to 5 From 66'-6" to 105'-0" 3'-0" No Column Line I wall From 5 to 7.3 From 66'-6" to 100'-0" 3'-0" No Column Line I wall From 1 to 3 From 100'-0" to roof 2'-0" Yes Column Line I wall From 3 to 4 From 100'-0" to roof 2'-0" Yes Column Line I wall From 4 to 16'-0" south of 5 From 107'-2" to roof 2'-0" No Column Line I wall From 16'-0" south of 5 to 5 From 105'-0" to roof 2'-0" No Column Line J-1 wall From 1 to 2 From 82'-6" to 100'-0" 2'-0" Yes Column Line J-1 wall From 2 to 4 From 66'-6" to 135'-3" 2'-6" Yes Column Line J-1 wall From 2 to 4 From 135'-3" to 153'-0" 2'-0" Yes Column Line J-1 wall From 4 to shield building From 66'-6" to 107'-2" 2'-0" Yes Column Line J-2 wall From 2 to 4 From 66'-6" to 135'-3" 2'-6" Yes Column Line J-2 wall From 4 to intersection with shield From 66'-6" to 135'-3" 2'-0" Yes building wall Column Line K-2 wall From 2 to 4 From 66'-6" to 135'-3" 4'-9" Yes Column Line L-2 wall From 2 to 4 From 66'-6" to 135'-3" 4'-0" Yes Column Line N wall From 1 to 2 From 66'-6" to 100'-0" 3'-0" No Column Line N wall From 1 to 12'-9" north of 1 From 100'-0" to 125'-0" 3'-9" Yes Column Line N wall From 1 to 12'-9" north of 1 From 125'-0" to 135'-3" 2'-0" Yes Column Line N wall From 12'-9" north of 1 to 2 From 100'-0" to 118'-2 1/2" 3'-0" Yes Column Line N wall From 12'-9" north of 1 to 2 From 118'-2 1/2" to 135'-3" 2'-0" Yes Column Line N wall From 2 to 4 (or to shield building) From 66'-6" to 98'-1" 5'-6" No Column Line N wall From 2 to 4 (or to shield building) From 98'-1" to 135'-3" 5'-6" (11) Yes C-415 Amendment No. 165
Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building (1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
Column Line N wall From 1 to 4 (or to shield building) From 135'-3" to 180'-0" 2'-0" Yes Labyrinth Wall between Col. Line 3 and 4 and J-1 to Not Applicable From 82'-6" to 92'-6" 2'-6" Yes 5'-2" from J-2 N-S Shield Wall (low wall) 5'-7" west of column line K-2 From 100'-0" to 110'-0" 2'-6" Yes extending 16'-0" from column line 1 north N-S Shield Wall 2'-9" east of column line L-2 extending From 100'-0" to 109'-3" 3'-0" Yes 12'-9" from column line 1 north N-S Shield Wall 2'-9" east of column line L-2 extending From 109'-3" to 125'-0" 2'-9" Yes 12'-9" from column line 1 north E-W Shield Wall 10'-0" north of column line 1 extending From 100'-0" to 125'-0" 2'-9" Yes 13'-3" from column line N east Auxiliary Area Basemat From 1-7.3 and I-N, excluding shield From 60'-6" to 66'-6" 6'-0" No building Floor From 1 to 2 and I to N 82'-6" 2'-0" Yes Floor From 2 to 4 and J-1 to J-2 82'-6" 2'-0" Yes Floor From 4 north to the shield building 82'-6" 0'-9" Yes ending 17'-4" south of column line 5 and J-1 to J-2 Pipe Chase Floor From 2 north to the shield building 92'-6" 2'-0" Yes ending 17'-4" south of column line 5 and J-1 to J-2 Floor From 2 to 3 and J-2 to K-2 90'-3" 3'-0" Yes Floor From 3 to 4 and J-2 to K-2 92'-6" 2'-0" Yes Floor From 4 to 7.3 and I to J-1 82'-6" 2'-0" Yes Floor From 1 to 2 and I to N 100'-0" 3'-0" Yes Floor From 2 to 4 and K-2 to L-2 92'-8 1/2" 3'-2 1/2" Yes Floor From I to J-2 and 4 to shield building 107'-2" 2'-0" Yes and vertical wall 17'-0" south of column line 5 Floor From I to shield building wall and 105'-0" 0'-9" Yes from intersecting vertical wall before column line 5 to column line 5 Floor From column line 1 to 10'-0" north of 125'-0" 3'-0" Yes column line 1 and from 2'-9" east of column line L-2 to N C-416 Amendment No. 165
Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building(1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
Floor From 12'-9" north of column line 1 118'-2 1/2" 2'-0" Yes to 2 and from 2'-9" east of column line L-2 to N Floor From 3 to 4 and J-2 to K-2 117'-6" 2'-0" Yes Floor From 2 to 4 and I to J-1 153'-0" 1'-3" Yes Roof From 1 to 4 and I to N 180'-0" to 180'-9" 1'-3" Yes Floor From 4 to 16'-0" south of column 135'-3" 0'-9" Yes line 5 and from I to intersection with shield building wall Floor From 16'-0" south of column line 5 133'-0" 0'-9" Yes to column line 5 and from I to intersection with shield building wall Auxiliary Building Walls/Floors Non-Radiologically Controlled(15)
Column Line 11 wall From I to Q From 66'-6" to 100'-0" 3'-0" No Column Line 11 wall From I to Q From 100'-0" to 117'-6" 2'-0" Yes Column Line 11 wall From I to L From 117'-6" to roof 2'-0" Yes Column Line 11 wall From L to M From 117'-6" to 135'-3" 4'-0" Yes Column Line 11 wall From M to P From 117'-6" to 135'-3" 2'-0" Yes Column Line 11 wall From P to Q From 117'-6" to 135'-3" 4'-0" Yes Column Line 11 wall From L to Q From 135'-3" to roof 2'-0" Yes Column Line 7.3 wall From I to shield building From 66'-6" to 100'-0" 3'-0" Yes Column Line 7.3 wall From I to shield building From 100'-0" to roof 2'-0" No Column Line I wall From 7.3 to 11 From 66'-6" to 100'-0" 3'-0" No Column Line I wall From 5 to 11 From 100'-0" to roof 2'-0" No Column Line J wall From 7.3 to 11 From 66'-6" to 117'-6" 2'-0" No Column Line K wall From shield building wall to 11 From 66'-6" to 135'-3" 2'-0" Yes Column Line L wall From shield building wall to 11 From 66'-6" to roof 2'-0" Yes Column Line M wall From shield building wall to 11 From 66'-6" to roof 2'-0" Yes Column Line P wall From shield building wall to 11 From 66'-6" to roof 2'-0" Yes Column Line Q wall From shield building wall to 11 From 66'-6" to 100'-0" 3'-0" No Column Line Q wall From shield building wall to 11 From 100'-0" to roof 2'-0" Yes Column Line 9.2 wall From I to J and K to L From 117'-6" to 135'-3" 2'-0" Yes C-417 Amendment No. 165
Table 3.3-1 Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building (1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall (7)
Wall or Section Description Column Lines Elevation Range(7)(8) Thickness(2)(3)(4)(5) (9)(18) (Yes/No)
Labyrinth Wall between Column Line 7.3 and 9.2 and J to J to K From 117'-6" to 135'-3" 2'-0" Yes K
Auxiliary Area Basemat From 7.3-11 and I-Q, excluding From 60'-6" to 66'-6" 6'-0" No shield building Floor From 5 to 10'-6" south of 7.3 and I to 100'-0" 2'-0" Yes shield building wall Floor From 10'-6" south of 7.3 to 7.3 and I 100'-0" 3'-0" Yes to shield building wall Floor From K to L and shield building wall 100'-0" 0'-9" Yes to column line 10 Main Control Room Floor From 9.2 to 11 and I to L 117'-6" 2'-0" Yes Floor Bounded by shield bldg, 7.3, J, 9.2 117'-6" 2'-0" Yes and L Floor From shield building to 11 and L to 117'-6" 2'-0" Yes Q
Floor From 5 to 7.3 and from I to 135'-3" 0'-9" Yes intersection with shield building wall Annex Building(16)
Column line 2 wall From E to H From 107'-2" to 135'-3" 19 3/4" Yes Column line 4 wall From E to H From 107'-2" to 162'-6" & 166'-0" 2'-0" Yes N-S Shield Wall between E and F From 2 to 4 From 107'-2" to 135'-3" 1'-0" Yes Column line 4.1 wall From E to H From 107'-2" to 135'-3" 2'-0" Yes N-S Labyrinth Wall between column Not Applicable From 100'-0" to 112'-0" 2'-0" Yes line 7.8 and 9 and G to H E-W Labyrinth Wall between column Not Applicable From 100'-0" to 112'-0" 2'-0" Yes line 7.1 and 7.8 and G to H Column Line 9 wall From E to connecting wall From 107'-2" to 117'-6" 2'-0" Yes between G and H Column Line E wall From 9 to 13 From 100'-0" to 135'-3" 2'-0" Yes Column Line 13 wall From E to I.1 From 100'-0" to 135'-3" 2'-0" Yes Column Line I.1 wall From 11.09 to 13 From 100'-0" to 135'-3" 2'-0" Yes Corridor Wall between G and H From 9 to near 13 From 100'-0" to 117'-6" 1'-6" Yes C-418 Amendment No. 165
Table 3.3-1 (cont.)
Definition of Wall Thicknesses for Nuclear Island Buildings, Turbine Building, and Annex Building(1)
Applicable Radiation Floor Elevation or Concrete Shielding Wall Wall or Section Description Column Lines(7) Elevation Range(7)(8) Thickness(2)(3)(4)(5)(9)(18) (Yes/No)
Corridor Wall between G and H From 9 to 13 From 117'-6" to 135'-3" 1'-6" Yes Column Line 9 wall From E to H From 117'-6" to 158'-0" 2'-0" Yes Floor From 2 to 4 and E to H 135'-3" 0'-8" Yes (12)
Floor From 4 to 4.1 and E to H 135'-3" 1'-0" Yes Floor From 9 to 13 and E to I.1 117'-6" 0'-8" (12)(13) Yes (12)
Floor From 9 to 13 and E to I.1 135'-3" 0'-8" Yes Containment Filtration Rms A and B (North Wall) Between column line E to H From 135'-3" to 158'-0" 1'-0" Yes Containment Filtration Rms A and B (East wall) Between column line E to F From 135'-3" to 158'-0" 1'-0" Yes Containment Filtration Rm A (Floor) Between column line E to H 135'-3" 1'-0" (12) Yes (12)
Containment Filtration Rm B (Floor) Between column line E to H 150'-3" 0'-8" Yes Turbine Building(17)
Wall adjacent to Column Line I.2 From Col. Line 11.05 to 11.2 From 100'-0" to 169'-0" 3'-0" No Wall along Column Line 11.2 From near I.2 to near Col. Line R From 100'-0" to 169'-0" 2'-0" No Wall adjacent to Column Line R From Col. Line 11.2 to Col. Line From 100'-0" to 169'-0" 3'-0" No 11.02 Wall along Column Line 11.02 From near Col. Line R to near Col. From 100'-0" to 169'-0" 2'-0" No Line Q Wall along Column Line 11.05 From Col. Line K.4 to near Col. Line From 100'-0" to 169'-0" 2'-0" No I.2 C-419 Amendment No. 165
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 759 3.3.00.01 1. The physical arrangement of the An inspection of the nuclear The as-built nuclear island nuclear island structures and the annex island structures, the annex structures, the annex building, building is as described in the Design building, the radwaste building, the radwaste building, the Description of this Section 3.3 and the turbine building, and the turbine building, and the Figures 3.3-1 through 3.3-14. The diesel generator building will be diesel generator building physical arrangement of the radwaste performed. conform with the physical building, the turbine building, and the arrangement as described in diesel generator building is as the Design Description of this described in the Design Description of Section 3.3 and Figures 3.3-1 this Section 3.3. through 3.3-14.
760 3.3.00.02a.i.a 2.a) The nuclear island structures, i) An inspection of the nuclear i.a) A report exists which including the critical sections listed in island structures will be reconciles deviations during Table 3.3-7, are seismic Category I and performed. Deviations from the construction, including are designed and constructed to design due to as-built conditions Table 3.3-1 wall and floor withstand design basis loads as will be analyzed for the design thicknesses, and concludes specified in the Design Description, basis loads, and for radiation that the as-built containment without loss of structural integrity and shielding. internal structures, including the safety-related functions. the critical sections, conform 3.) Walls and floors of the nuclear to the approved design and island structures as defined on will withstand the design basis Table 3.3-1 except for designed loads specified in the Design openings or penetrations, provide Description without loss of shielding during normal operations. structural integrity or the safety-related functions, and without impacting compliance with the radiation protection licensing basis.
761 3.3.00.02a.i.b 2.a) The nuclear island structures, i) An inspection of the nuclear i.b) A report exists which including the critical sections listed in island structures will be reconciles deviations during Table 3.3-7, are seismic Category I and performed. Deviations from the construction, including are designed and constructed to design due to as-built conditions Table 3.3-1 wall and floor withstand design basis loads as will be analyzed for the design thickneses, and concludes that specified in the Design Description, basis loads, and for radiation the as-built shield building without loss of structural integrity and shielding. structures, including the critical the safety-related functions. sections, conform to the 3.) Walls and floors of the nuclear approved design and will island structures as defined on withstand the design basis Table 3.3-1 except for designed loads specified in the Design openings or penetrations, provide Description without loss of shielding during normal operations. structural integrity or the safety-related functions, and without impacting compliance with the radiation protection licensing basis.
C-423 Amendment No. 165
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 762 3.3.00.02a.i.c 2.a) The nuclear island structures, i) An inspection of the nuclear i.c) A report exists which including the critical sections listed in island structures will be reconciles deviations during Table 3.3-7, are seismic Category I and performed. Deviations from the construction, including are designed and constructed to design due to as-built conditions Table 3.3-1 wall and floor withstand design basis loads as will be analyzed for the design thicknesses, and concludes that specified in the Design Description, basis loads, and for radiation the as-built structures in the without loss of structural integrity and shielding. non-radiologically controlled the safety-related functions. area of the auxiliary building, 3.) Walls and floors of the nuclear including the critical sections, island structures as defined on conform to the approved Table 3.3-1 except for designed design and will withstand the openings or penetrations, provide design basis loads specified in shielding during normal operations. the Design Description without loss of structural integrity or the safety-related functions, and without impacting compliance with the radiation protection licensing basis.
763 3.3.00.02a.i.d 2.a) The nuclear island structures, i) An inspection of the nuclear i.d) A report exists which including the critical sections listed in island structures will be reconciles deviations during Table 3.3-7, are seismic Category I and performed. Deviations from the construction, including are designed and constructed to design due to as-built conditions Table 3.3-1 wall and floor withstand design basis loads as will be analyzed for the design thicknesses, and concludes specified in the Design Description, basis loads, and for radiation that the as-built structures in without loss of structural integrity and shielding. the radiologically controlled the safety-related functions. area of the auxiliary building, 3.) Walls and floors of the nuclear including the critical sections, island structures as defined on conform to the approved Table 3.3-1 except for designed design and will withstand the openings or penetrations, provide design basis loads specified in shielding during normal operations. the Design Description without loss of structural integrity or the safety-related functions, and without impacting compliance with the radiation protection licensing basis.
764 3.3.00.02a.ii.a Not used per Amendment No. 165 765 3.3.00.02a.ii.b Not used per Amendment No. 165 C-424 Amendment No. 165
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 766 3.3.00.02a.ii.c Not used per Amendment No. 165 767 3.3.00.02a.ii.d Not used per Amendment No. 165 768 3.3.00.02a.ii.e 2.a) The nuclear island structures, ii) An inspection of the as-built ii.e) A report exists that including the critical sections listed in concrete thickness will be concludes that the as-built Table 3.3-7, are seismic Category I performed. concrete thicknesses of the and are designed and constructed to annex building sections withstand design basis loads as conform with the building specified in the Design Description, sections defined in without loss of structural integrity and Table 3.3-1, except for the safety-related functions. designed openings or 4.a) Walls and floors of the annex penetrations, or the report building as defined on Table 3.3-1 documents an evaluation of except for designed openings or thickness deviations identified penetrations provide shielding during during construction and normal operations. demonstrates that the as-built structures will withstand the design basis loads without loss of structural integrity and without impacting compliance with the radiation protection licensing basis.
769 3.3.00.02a.ii.f 2.a) The nuclear island structures, ii) An inspection of the as-built ii.f) A report exists that including the critical sections listed in concrete thickness will be concludes that the as-built Table 3.3-7, are seismic Category I performed. concrete thicknesses of the and are designed and constructed to turbine building sections withstand design basis loads as conform to the building specified in the Design Description, sections defined in without loss of structural integrity and Table 3.3-1, except for the safety-related functions. designed openings or penetrations, or the report documents an evaluation of thickness deviations identified during construction and demonstrates that the as-built structures will withstand the design basis loads without loss of structural integrity.
770 3.3.00.02b 2.b) Site grade level is located relative Inspection of the as-built site Site grade is consistent with to floor elevation 100'-0" per grade will be conducted. design plant grade within the Table 3.3-5. dimension defined on Table 3.3-5.
771 3.3.00.02c Not used per Amendment No. 84 C-425 Amendment No. 165
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 777 3.3.00.03a Not used per Amendment No. 165 778 3.3.00.03b Not used per Amendment No. 165 779 3.3.00.03c Not used per Amendment No. 165 780 3.3.00.03d Not used per Amendment No. 165 C-427 Amendment No. 165
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 781 3.3.00.04a Not used per Amendment No. 165 782 3.3.00.04b 4.b) Walls of the waste accumulation Inspection of the as-built A report exists and concludes room in the radwaste building except radwaste building wall that the shield walls of the for designed openings or penetrations thicknesses will be performed. waste accumulation room in provide shielding during normal the radwaste building except operations. for designed openings or penetrations are consistent with the concrete wall thicknesses of 1'-4", and a concrete wall thickness of 1'-8" near the radwaste bunkers, or the report documents an evaluation of thickness deviations identified during construction and demonstrates there is no impact to compliance with the radiation protection licensing basis.
783 Deleted.
784 3.3.00.05a 5.a) Exterior walls and the basemat of An inspection of the as-built A report exists that confirms the nuclear island have a water barrier water barrier will be performed that a water barrier exists on up to site grade. during construction. the nuclear island exterior walls up to site grade.
785 3.3.00.05b 5.b) The boundaries between rooms An inspection of the auxiliary A report exists that confirms identified in Table 3.3-2 of the building rooms will be floors and walls as identified auxiliary building are designed to performed. on Table 3.3-2 have provisions prevent flooding of rooms that contain to prevent flooding between safety-related equipment. rooms up to the maximum flood levels for each room defined in Table 3.3-2.