i ALABAMA POWER COMPANY i

t i

FARLEY NUCLEAR PLANT UNIT ONE l

I i

LICENSE NO. NPF-2 I

1 I

.\\

?

t i

SEMI-ANNUAL RADI0 ACTIVE EtTLUENT RELEASE REPORT I

JULY l, 1980 THROUGH DECEMBER 31, 1980

(

i 9

1 i

f f

i i

I 4

l 4

I l

I I

i 81030803 %

[

TABLE OF CONTENTS i

e SUBJECT PAGE A.

Introduction 1

B.

Effluent and Waste Disposal Semiannual Report f

Supplemental Information 1.

Regulatory Limits 2

i l

  • a.

Fission and Activation Gases b

Iodines and Particulates

[

c.

Liquid Effluents 2.

Maximum Permissible Concentrations 2

l r

a.

Airborne j

i b.

Liquid 3.

Average Energy 3

4.

Measurements and Approximations of Total 3

Activity a.

Fission and Activation Gases b.

Iodines t

c.

Particulates i

d.

Liquid Effluents t

i 5.

Batch Releases 5

l a.

Liquid b.

Gaseous 6.

Abnormal Releases 6

a.

Liquid l

I b.

Gaseous 3

i

l i

i 1

TABLE OF CONTENTS (con't)

{

+

i SUBJECT FAGE i

i 1

7.

Estimate of Total Error 6

8.

' Solid Waste 7

)

9.

Radiolecimi Impact on Man 7

r i

t

10. Meteorological Data 7

f

11. Liquid Release " Principal Gamma Emitter" 8

i Evaluation

}

r a

i e

i b

i i

l J

I r

i E

e f

s

',,. =

t I

J.

i h

f

?

I

)

i l

t f,

I I

l i

[

i i

d' 1

n

,. _. - - ~

TABLES Title Table Number r

Gaseous Effluents - Summation of All Releases lA Gaseous Effluents - Elevated Releases 1B Gaseous Effluents - Ground Level Releases lc Liquid Effluents.- Summation of All Releases 2A Liquid Effluents - Continuous and Batch Modes 2B Solid Waste and Irradiated Fuel Shipments 3

Hours At Each Wind Speed and Direction 4A Classification Of Atmospheric Stability 4B Liquid Effluent Sampling Frequencies and Sensitivities 5

~

Gaseous Effluent Sampling Frequencies and Sensitivities 6

Liquid Discharges Not Meeting Specified Detection 7

Limits i

e e

l INTRODUCTION

[

i f

This semi-annual radioactive release report for the period JULY 1 to DECEMBER 31, 1980 is submitted in accordance with Appendix 3 to Farley Nuclear Plant License No. NPF-2.

Appendix B will hereinafter be referred to as the f

Environmental Technical Specifications or ETS.

i.

All liquid and airborne discharges to the environment during this reporting j

period were analyzed in accordance with requirements in the ETS. For all

[

effluent releases, the concentrations of radioactive material were within i

ETS limits.

I e

1 t

L I

1 i

i 1-i l

b 6

I i

r I

i i

i e

1 r

- ~

-.n.

l EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SUPPLEMENTARY INFORMATION 1.

Regulatory Limits i

a.

Fission and Activation Gases The release rate limit at any time of noble gases to areas at or beyond the site bcundary shall be such that' 14 2

106 pgi I K. I (X/Q)# Q"

<500 mrem /yr 1

uCi i

v and

~

~

+

14 2

~

6 10 pCi I

(Lg + 1.1 M1) I (X/Q)y Q

<3000 ty uCi i

y mrem /yr

~

where the terms are defined in section 2.3 of the ETS b.

Iodines and Particulates The release rate limit for campling period of all radioiodines and radioactive materials in particulate form and radionuclides other j

than noble gases released to the environs as part of the gaseous wastes from the site shall be such that 18 2

6 10 pCi I P v [ (X/Q),y I

Q

<6.3 mrem /yr g

ty uC1 1

'~

where the terms are defined in Section 2.3 of ET' c.

Liquid Effluents The concentration of radioactive materials released in liquid effluents to unrestricted areas from all reactors at the site shall not exceed at any time the values specified in 10 CFR Part 20, Appendix B, Table II, Column 2.

The concentration of dissolved or entrained noble gases, released in liquid effluents to unrestricted areas from all reactors at the site, shall not exceed at any time 4 E-5 pCi/ml in water.

2.

Maximum Permissible Concentrations Airborne - The maximum permissible concentration of radioactive a.

materials in gaseous effluents is limited by the dose rate restrictions of 10CFR20.

In thi: case, the maximum permissible concentrations are actually determined by the dose factors in Table 2.5, 2.6 and 2.7 of the ETS.

2

4 b.

Liquid - 10 CFR Part 20, Appendix B Table II, Column 2.*

  • NOTE: The MPC chosen is the most conservative value of either i

the soluble or insoluble NPC for each isotope.

l 3.

Average Energy Not Applicable for Farley's ETS.

~

4.

Measurements and Approximations of Total Activity The following discussion details the methods used to measure and approximate total activity for the following:

a.

Fission and Activation Gases b.

Iodines c.

Particulates d.

Liquid Effluents Tables 5 and 6 give sampling frequencies and minimum detectable sensitivity

[

requirements for the analysis of liquid and gaseous effluent streams.

Values in the attached tables given as zero do not mean that the nuclides were not present. A zero indicates that the nuclide was not present at levels greater than the sensitivity requirements shown in Tables 5 and l

6.

For some nuclides, lower detection limits than required may be readily achievable; when a nuclide is measured below its stated limits I _.

it is reported.

Fission and Activation Gases The following noble gases are considered in evaluating gaseous airborne discharge:

Ar-41 Kr-89 Xe-133m

~

Kr-85m Kr-90 Xe-135m Kr-85 Xe-131m Xe-135 Kr-87 Xe-133 Xe-137 Kr-88 Xe-138 Periodic grab samples from plant effluent streams are analyzed by a computerized pulse height analyzer system utilizing high resolution.

germanium detectors.

(See Table 6 for sampling and analytical requirements).

Isotopic values thus obtained are used for dose release rate calculations as given in section la of this report.

Only those nuclides that are detected are used in this computation.

During the period between grab samples, the amount of radioactivity released is based on the effluent monitor readings. Monitors are assigned a calibration factor based upon the last isotopic analysis using the following relationship:

Ci = pi + m, where Ci = isotopic calibration factor for isotope i.

t 3

I

i pi = concentration of isotope i in the grab sample, in pCi/ml.

t m = net monitor reading associated with the effluent stream.

(determinea at time of grab sample)

These calibration factors along with the hourly effluent monitor readings are input to the laboratory computer where the release rates for individual nuclides are calculated and stored.

To ensure that isotopic distributions do not change significantly during major operational occurences, the frequency of grab sampling is increased to satisfy the requirements of footnote "C" of Table 6, " Radioactive Gaseous Waste, Sampling and Analysis", (ETS Table 2-2).

Particulate and Iodine

[

The radioiodines and radioactive materials in particulate forms to be considered are:

Zn-65 Sr-89 Cs-134 Cr-51 Sr-90 Cs-136 tin-54 Zr-95 Cs-137 Fe-59 Sb-124 Ba-140 Co-58 I-131 Ce-141 Co-60 I-133 Other nuclides with

" ~~

half-life greater than 8 days f

Continuous Releases Continuous sampling is performed on the continuous release points (i.e. the Plant Vent Stack, Containment Purge and the Turbine Building Vent). Particulate material ir collected by filtration.

Iodines are collected by adsorption on a charcoal filter. Periodically these filters are removed and analyzed on the pulse height analyzer to identify and quantify radioactive materials collected on the filters. Particulate filters are then analyzed for gross alpha, i

and Strontium 89 and 90, as required.

Gross alpha detersinations are made using a 2 pi gas flow proportional counter. Sr-89 and 90 values are obtained by chemical separation and subsequent analysis using 2 pi gas flow proportional counters.

Batch Releases The processing of batch type releases (from Containment Purge and i

Waste Cas Decay Tanks) is analogous to that for continuous releases, except that the release is not commenced until grab samples have been obta'.ned and analyzed.

I; quid Effluents The radionuclides listed below are considered when evaluating liquid effluents:

4 1

i H-3 Sr-91 Cs-134 Co-58 Mo-90 Cs-136 Co-60 Te-99m Cs-137 Fe-59 Ru-103 Ba-140 Zn-65 Ru-106 La-140 Ma-54 I-131 Ce-141 Cr-51 I-132 Ce-144 Sr-89 I-133 Sr-90 I-135 Batch Releases - Representative pre-release grab samples are obtained and analyzed per Table 5.

Isotopic analyses are performed using the computerized pulse height analysis system previously described.

Aliquots of each pre-release sample proportional to the waste volume released, are composited in accordance with requirements in Table 5.

Strontium determinations are made by performing a chemical separation and counting the strontium thus separated using a 2 pi gas flow proportional counter. Gross beta-gamma and gross alpha determinations are made using 2 pi gas flow proportional counters.

Tritium concentrations are determined by using liquid scintillation techniques. Dissolved gases are determined employing grab sampling techniques and then counting on the pulse height analyzer system.

Continuous Releases Continuous Releases (from the Steam Generator Blowdown) are analogous to that of the batch releases except that they are to be analyzed on a weekly composite basis per Table 5.

5.

Batch Releases a.

Liquid 1.

Number of batch releases:

185 2.

Total time period for batch releases:

68,592 minutes 3.

Maximum time period for a batch release: 11,685 minutes 4.

Average time period for a batch release:

371 minutes 5.

Minimum time period for a batch release:

20 minutes l

6.

Average stream flow during periods of release of effluent into a flowing stream:

3,890 cfs b.

Gaseous 1.

Number of batch releases:

9 l

l 5

l l

_ -. =

2.

Total time period for batch releases:

99 hours0.00115 days <br />0.0275 hours <br />1.636905e-4 weeks <br />3.76695e-5 months <br /> 3.

Maximum time period for a batch release:

21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br /> t

4.

Average time period for a batch release:

11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br /> I

5.

Minimum time period for a batch release:

5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 6.

Abnormal Release a.

Liquid

[

i 1.

Number of releases: None 2.

Total activity released: N/A NOTE 1: See Table 7 for listing of Liquid Batch releases that did not meet specified detection limits.

b.

Gaseous 1.

Number of releases: None 2.

Total activity released: N/A 7.

Estimate of Total Error i

" ~ ~

a.

Liquid 1.

The maximum error associated with volume and flow measurements, based upon plant calibration practice is estimated to be 1 10%.

2.

The average arror associated with counting is estimated 1o be less than 1 15%.

b.

Gaseous 1.

The maximum errors associated with monitor readings, sample flow, vent flow, sample collection, monitor calibration and laboratory procedure are collectively estimated to be:

Fission and Activation Gases Iodine Particulates Tritium 75%

60%

50%

45%

e 6

L 10.

Meteorological Data r

See Table 4A.

i 1st Quarter Continuous 2nd Quarter Continuous 11.

Liquid Release " Principal Gamma Emitter" Evaluation Detectable limits for activity analyses are based upon the technical feasibility and on the potential significance in the environment of the quantities released. In practice, when an isotope's LLD could not be met due to other nuclides being present in much greater concentrations, computations were made to determine if the isotope (s) of interest were actually " Principal Gamma Emitters" by the following definition:

" Principal Gamma Emitters" - Those gamma emitters when quantified represent greater ' han 1% of the total activity or total dose commitment of the ;ffluent release in question.

8 4

l w-

=

i 8

i I

2.

The average error associated with counting i. estimated to be.

3 l

L Fission and Activation Gases Iodine Particulates Tritium t

6%

18%

19%

12%

l c.

Solid Radwaste The error involved in determining the contents of solid radwaste shipments is estimated to less than + 15%.

p 8.

Solid Waste See Table 3 i

9.

Radiological Impact On Man a.

Water Rela'ted Exposure Pathways 3rd Quarter 4th Quarter t

Total.Lody = 1.3E-02 mrem 6.0E-02 mrem l

Bone = 1.0E-02 mrem 4.4E-02 mrem I

Liver = 1.7E-02 mrem 8.0E-02 mrem

{

Thyroid = 1.4E-03 mrem 1.9E-03 mrem i

Kidney = 5.8E-03 mrem 2.7E-02 mrem Lungs = 2.2E-03 mrem 9.7E-03 mrem GI Tract = 4.1E-03 mrem 9.0E-03 mrem b.

Gaseous Related Exposure Pathways i

3rd Quarter 4th Quarter Total Body = 2.4E 00 mrem 1.0E-02 mrem Skin = 1.6E 00 mrem 1.0E-02. mrem c.

Particulate and Iodine 3rd Quarter 4th Quarter Organ Dose = 2.4E-02 mrem 1.1E-02 ' mrem I

l i

7 I

l

l 1980 TABLE 1A r

GASEOUS EFFLUENTS--SUMMATION OF. ALL RELEASES UNITS OTR 3 A.

Fission & activation gases:

i. Total release Ci 8.34E 03 2.

Average Release rate for period uCi/sec 1.05E 03 3.

% of Technical specification limit i.06E-Oi*

1.63E-Oi**

B.

Iodines

1. Total iodine-131 Ci 6.33E-08
2. Average Release rate for period uCi/sec 7.97E-09 3.

% of Technical specification limit 2.43E-iia 4*

C.

Particulates 1.

Particulates with 71/2>8 days Ci 2.14E-03 2.

Average Release rate for period uCi/sec 2.69E-04 3.

% of Technical specification limit 6.87E-06***

4.

Gross alpha radioactivity Ci 0.00E 00 D.

Tritium 1.

Total release Ci 1.56E 01 2.

Average Release rate for period uCi/sec i.96E 00

3. % of Technical specification limit 1.85E-07***
  • Whole body limit ((500 neen/yr)
      • Extren. limit (<3000 nren/yr)
        • % of 6.3 nren/yr for all 19 isotopes

1980 TA3LE 1A GASEQUS EFFLUENTS--SUMMATION OF ALL RELEASES UNITS OTR 4 A.

Fission & activati.on gases:

1.

Total relear,e Ci 1.28E 03

2. Average Release rate for period uCi/ set i.61E 02 3.

% of Technical specification limit 8.69E-03*

1.45E-02**

B.

Iodines 1.

Total iodine-131 Ci 6.80E-08

2. Average Release rate for period UCi/sec 8.56E-09 3.

% of Technical specification limit 1.75E-10***

C.

Particulates 1.

Particulates with Ti/2>9 days Ci 1.34E-05 l

2. Average Release rats for period uCi/sec 1.69E-06
3. % of Technical specification limit 1.83E-06***

4 Gross alpha radioactivity Ci 0.00E 00 D.

Tritium

i. Total release Ci 5.71E 02 2.

Average Release rate for period uCi/sec 7.18E 01 3.

% of Technical specification limit 6.65E-06***

  • Whole body limit ((500 nren/yr)

Extren. limit (<3000 nren/yr)

% of 6.3 nren/yr for all 19 isotopes

_ _ _ _ ~ _ - _

_ _ _ _ _ ~ -

j TA3LE IB 4

GASEQUS EFFLUENTS--ELEVATED RELEASE e

a 1

CONTINUOUS BATCH Mode Mode Nuclides Released Unit QTRt 3 OTRt 3 l

l 1.

Fission gases Ar-41 Ci 2.31E 03 5.39E-03 Xe-137 Ci 0.00E 00 1.31E-03 Kr-90 Ci 0.00E 00 0.00E 00 i

Xe-135M Ci 0.00E 00 0.00E 00 i

i Kr-85 Ci 3.iOE 00 1.93E 00 Xe-138 Ci 0.00E 00 1.81E-04 Kr-87 Ci 0.00E 00 6.03E-04 f

Kr-85M Ci 0.00E 00 2.71E-02 j

Xe-135 Ci 4.22E 01 5.67E-Oi j

Xe-133M Ci 5.96E 00 1.07E-01 Kr-89 Ci 0.00E 00 0.00E 00 Kr-88 Ci 0.00E 00 1.38E-02 Xe-131H Ci 1.69E 01 1.91E-01 j

Xe-133 Ci 5.84E 03 9.55E 00

}'

Total for period Ci 8.2iE 03 1.24E 01 3

)

2.

Iodines I

I~

I-133 Ci 0.00E 00 0.00E 00 l

I-131 Ci

-1.09E-07 1.72E-07 j

Total for period Ci

-1.09E-07 1.72E-07 3.

Particulates Sb-12*

Ci 0.00E 00 0.00E 00 Co-60 Ci 1.70E-05 2.77E-08 Zn-65 Ci 0.00E 00 0.00E 00 Fe-59 Ci 0.00E 00 0.00E 00 l

Mn-54 Ci 0.00E OG 9.57E-10

[

Cs-136 Ci 0.00E 00 0.00E 00 i

f Co-58 Ci 2.192-05 1.05E-08 l

1 Zr-95 Ci 0.00E 00 0.00E 00

[

[

Cs-137 Ci 0.00E 00 0.00E 00

}

Cs-134 Ci 0.00E 00 0.00E 00 r

Ba-140 Ci 0.00E 00 0.00E 00 l

I-133 Ci 0.00E 00 0.00E 00 l

~

I-131 Ci 4.02E-ii 6.33E-08 j

Cr-51 Ci 1.2iE-ii 0.00E 00 Ce-141 Ci 0.00E 00 0.00E 00 3

i Sr-89 Ci 3.83E-06 0.00E 00 Sr-90 Ci 0.00E 00 0.00E 00 i

Total for period Ci 4.26E-05 1.02E-07 4.

Trition 1

H-3 Ci 1.54E 01 3.94E-04 i

. ~. -

TABLE IB l

GASEOUS EFFLUENTS--ELEVATED RELEASE CONTINUQUS BATCH Mode Mode Nuclides Released Unit OTR$ 4 OTR 6 4 l

1.

."ission gases Ar-si Ci 1.01E 02 1.60E-02 Xe-137 Ci 0.00E 00 2.95E-03 Kr-90 Ci 1.59E-02 0.00E 00 Xe-135M Ci 0.00E 00 0.00E 00 Kr-85 Ci 7.52E-01 1.26E 0" Xe-138 Ci 0.00E 00 2.55E-03 Kr-87 Ci 0.00E 00 0.00E 00 Kr-85M Ci 1.65E-03 3.61E-03 Xe-135 Ci 1.15E 01 7.28E-02 Xe-133M Ci 3.12E-01 9.34E-02 Kr-89 Ci 0.00E 00 0.00E 00 Kr-88 Ci 0.00E 00 0.00E 00 Xe-131M Ci 1.89E-Oi 2.19E-01 Xe-133 Ci 2.27E 02 1.2iE 01 Total for period Ci 3.41E 02 1.38E 01 2.

Iodines I-133 Ci 0.00E 00 0.00E 00 l

I-131 Ci

-1.31E-10 2.61E-10 Total for period Ci

-i.31E-10 2.61E-10 3.

Particulates l

l Sb-124 Ci 0.00E 00 0.00E 00 i

Co-60 Ci 4.55E-06 5.86E-07 Zn-65 Ci 0.00E 00 0.00E 00 Fe-59 Ci 0.00E 00 0.00E 00 Mn-54 Ci G.90E 00 0.00E 00 Cs-136 Ci 0.00E 00 0.00E 00 Co-58 Ci 3.40E-06 0.00E 00 Zr-95 Ci 0.00E 00 0.00E 00 Cs-137 Ci 2.32E-08 0.00E 00 Cs-134 Ci 0.00E 00 0.00E 00 Ba-140 Ci 0.00E 00 0.00E 00 I-133 Ci 0.00E 00 0.00E 00 I-131 Ci 0.00E 00 1.31E-10 Cr-51 Ci 0.00E 00 0.00E 00 Ce-141 Ci 0.00E 00 0.00E 00 Sr-89 Ci 4.07E-06 2.67E-12 l

Sr-90 Ci 0.00E 00 0.00E 00 l

Total for period Ci 1.20E-05 5.86E-07 4.

Tritiun H-3 Ci 5.63E 02 1.13E-03

-. _ ~

TABLE 1C I

3 GASEOUS EFFLUENTS--GROUND-LEVEL RELEASE i

i CONTINUOUS BATCH Mode Mode i

Nuclides Released Unit OTR) 3 OTR t 3 l

1 1

i. Fission gases i

Ar-41 Ci 3.36E 01 1.08E-04 4

Xe-137 Ci 0.00E 00 3.36E-05

~

Kr-90 Ci 0.00E 00 0.00E 00 Xe-135M Ci 2.51E-05 0.00E 00 i

j Kr-85 Ci 6.48E-01 1.65E-02

}

{

Xe-138 Ci 1.77E-05

4. 63 E- 0 6

[

Kr-87 Ci 1.86E-02 1.49E-05

[

j Kr-85M Ci 0.00E 00 6.63E-04 I

i Xe-135 Ci 2.75E 00 1.42E-02 Xe-133M Ci 2.iiE 01 2.62E-03 3

l Kr-89 Ci 0.00E 00 0.00E 00 i

Kr-88 Ci 0.00E 00 3.41E-04

}

Xe-131M Ci 4.56E-02 3.iiE-03

[

t Xe-133 Ci 5.44E 01 2.05E-01 i

f Total for period Ci 1.13E 02 2.42E-Oi 2.

Iodines ih-I-133 Ci 0.00E 00 0.00E 00 I-131 Ci 2.2iE-13 0.00E 00 Total for period Ci 2.2iE-13 0.00E 00 1

I I

l

]

3.

Particulates Sb-124 Ci 0.00E OP 0.00E 00

[

Co-60 Ci 6.23E-08 0.00E 00

~

Zn-65 Ci 0.00E 00 0.00E 00 l

Fe-59 Ci 0.00E 00 0.0 0E 00 Mn-54 Ci 0.00E 00 0.00E 00 Cs-136 Ci 0.00E 00 0.00E 00 Co-58 Ci 1.34E-07 0.00E 00 i

{

Zr-95 Ci 0.00E 00 0.00E 00 Cs-137 Ci 0.00E 00 0.00E 00 Cs-134 Ci 0.00E 00 0.00E 00 l

i Ba -14 0 Ci 0.00E 00 0.00E 00 l

I-133 Ci 0.00E 00 0.00E 00 I-131' Ci 2.2iE-13 0.00E 00 t

i Cr-51 Ci 9.06E-14 0.00E 00 Ce-141 Ci 0.00E 00 0.00E 00 i

Sr-89 Ci 2.iOE-33 0.00E 00 f

Sr-90 Ci 0.00E 00 0.00E 00 t

l Total for period Ci 2.iOE-03 0.00E 00 f

4.

Tritium H-3 Ci 1.41E-01 0.00E 00 0

i

TMILE IC GASEOUS EFFLUENTS--GROUND-LEVEL RELEASE f

CONTINUOUS BATCH Mode Mode Nuclides Released Unit QTRt 4 QTR6 4 i

2.

Fission gases Ar-41 Ci 5.74E 01 2.30E-03

~

Xe-137 Ci 0.00E 00 4.79E-05 Kr-90 Ci 2.56E-Oi 0.00E 00 t

Xe-135M Ci 0.00E 00 0.0 0E 00 l

Kr-85 Ci 1.35E 01 7.20E-03 Xe-138 Ci 0.00E 00 0.00E 00 l

j Kr-87 Ci 0.00E 00 0.00E 00 Kr-85M Ci 0.00E 00 4.38E-05 l

1 Xe-135 Ci 2.71E 01 2.96E-03 l

Xe-133M Ci 9.12E 00 3.81E-03 Kr-89 Ci 0.00E 00 0.00E 00 Kr-88 Ci 0.00E 00 0.00E 00 Xe-131M Ci 4.40E-03 2.82E-03 r

Xe-133 Ci 8.2iE 02 3.37E-Oi l

Total for period Ci 9.29E 02 3.56E-01

{

i 2.

Iodines y~

I-133 Ci 6.65E-0'6 0.00E 00 I-131 Ci 6.79E-08 5.50E-12 l'

Total for period Ci 6.72E-06 5.50E-12 3.

Particulates I

[

Sb-124 Ci 2.54E-ii 0.00E 00 Co-60 Ci 1.83E-07 5.87E-09

{~

Zn-65 Ci 9.32E-09 0.00E 00 t

l Fe-59 Ci 1.26E-ii 0.00E 00 Mn-54 Ci 1.22E-ii 0.00E 00 Cs-136 Ci 1.04E-ii 0.00E 00 i

Co-58 Ci 1.24E-07 0.00E 00 Zr-95 Ci 1.35E-ii 0.00E 00 Cs-137 Ci 1.06E-09 0.00E 00 t

Cs-134 Ci 8.29E-12 0.00E 00 Ba-140 Ci 3.22E-ii 0.00E 00 i

I-133 Ci 6.65E-06 0.00E 00 I-131 Ci 6.39E-08 2.84E-12 Cr-Si Ci 6.28E-ii 0.00E 00 Ce-141 Ci 8.33E-12 0.00E 00 Sr-89 Ci 3.86E-07 3.50E-14 l

Sr-90 Ci 2.40E-13 0.00E 00 l

4 Total for period Ci 7.42E-06 5.87E-09 f

1 4.

Trition H-3 Ci 8.23E 00 1.62E-05

l TADLE 2A EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1980 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES A.

Fission and activation products

1. Total release Ci 9.91E-03 9.58E-2.

Average diluted concentration During period Note (1) uCi/n1 i.75E-09 1.33E -

3.

Percent of applicable limit During period Note (i) 3.20E-02 1.48E-B. Tritium 1.

Total release Ci 4.39E 02 6.19E 2.

Average diluted concentration During period Note (i) uCi/n1 7.74E-05 8.56E-

3. Percent of applicable limit During period Note (i) 2.58E 00 2.85E C. Dissolved and entrained gases 1.

Total release Ci 9.51E-04 1.05E-(

2.

Average diluted concentration During period Note (i) uCi/n1 i.68E-10

1. 45E ':

3.

Percent of applicable limit During period Note (1) 4.19E-04 3. 62E--

i ~D. Gross alpha radioactivity 1.

Total release Ci 2.37E-05 1.65E-E. Volume of waste released liters i.2BE 07 1.45E (prior to dilution)

F. Volume of dilution water used During period Note (i) liters 5.66E 09 7.21E

~ NOTE:

(i) During period of discharge

TABLE 2B LIQUID EFFLUENTS-ALL SOURCESJuly 80THROUGHDec.

80 Nuclides Quarter 3, 80 Quarter 4.

80 roleased Unit Batches Continuous Batches Continuous Sr-89 C1 1.40E-05 0.00E 00 0.00E 00 2.73E-06 Sr-90 Ci 0.00E 00 4.64E-05 0.00E 00

0. 00E 00 Co-57 Ci 5.57E-06 0.00E 00 8.41E-06 0.00E 00 Co-144 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Tc-99M Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Co-141 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Np-239 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Cr-51 Ci 5.22E-04 0.00E 00 3.07E-04 2.86E-05 1.75E-06 2.22E-04 I-131 Ci 6.06E-06 4.23E-04 Ru-iO3 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 I-133 Ci 8.69E-07 0.00E 00 0.00E 00 0.00E 00 Be-140 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 An-76 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Co-134 Ci 7.58E-05 2.96E-g4 7.46E-04 8.55E-04 Ru-106 Ci 5.27E-07 0.00E 00 0.00E 00 0.00E 00 Ce-137 Ci 1.23E-04 3.52E-04 7.76E-04 8.08E-04 No-99' Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Zr-95 Ci 5.87E-06 0.00E 00 6.68E-06 2.00E-07 Nb-95 Ci 5.71E-05 0.00E 00 6.20E-05 9.01E-06 I-132 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Co-58 Ci 4.02E-03 2.86E-04 2.79E-03 4.2iE-04 Cs-136 Ci 0.00E 00 0.00E 00 7.37E-07 7 37E-07 7.07E-05 Mn-54 Ci 2.71E-04 4.42E-05 2.88E-04 Ag-iiOM Ci 1.01E-04 0.00E 00 7.82E-05 1.25E-05 Sr-91 Ci 0.00E 00 0.00E'00 0.00E'00 0.00E 00 Zn-65 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 I-135 Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Fe-59 Ci 2.49E-05 0.00E 00 7.34E-06 0.00E 00 3.57E-03 6.40E-04 Co-60 Ci 3.16E-03 4.74E-05 Cu-64 Ci 1.89E-05 0.00E 00 0.00E 00 0.00E 00 No-24 Ci 6.72E-08 0.00E 00 6.96E-06 6.53E-06 Le-140 C1 2.02E-06 0.00E 00 0.00E 00 0.00E 00 Ni-65 Ci 9.78E-07
0. 00E 00 6.74E-07
0. 00E 00 Totals Ci 8.41E-03 1.50E-03 8.65E-03 3.08E-03 XG-133 Ci 9.35E-04 1.00E-03 XE-135 Ci 1.53E-05 4.36E-05

i l

TABI-E 3 EFFLUENT AND WASTE DISPOSAL SDtIANNUAL REPORT FOR SECOND HALF OF 1980 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel) 1.

Type of Waste UNIT 6-MONTH PERIOD t

a.

Spent resins, filter sludges, m

7.3 E 01 evaporator bottoms, etc.

Ci 9.8 E 00 a

1.4 E 02 b.

Dry compressible waste, contaminated equip, etc.

Ci 1.8 E 00 c.

Irradiated components, control m

None rods, etc.

Ci a

d.

Other (describe) u None

~

2.

Estimate of major nuclide composition Ci a.

Cobalt-58 7.9 E 00 7.7 E-1 Cobalt-60 5.6 E 01 5.5 E 00 Tritium (Hydrogen-3) 3.0 E 01 2.9 E 00 b.

Cobalt-58 2.8 E 01 4.8 E-01 Cobalt-60 2.3 E 01 4.0 E-01 Iron-59 3.5 E 01 6.1 E-01

..--.r

t i

TABLE 3 (con't)

EFFLUENT AND WASTE DISPOSAL SDtIANNUAL REPORT FOR SECOND !!ALF OF 1980 SOLID WASTE AND 1RRADIATED FUEL SilIPMENTS 3.

Solid Waste Disposition Number of Shipments Mode of Transportation Destination 15 Chem-Nuclear Transport Chem-Nuclear Systems, Incorporated Barnwell, South Carolina 4.

Type Of Container (la)

Type of Container (Ib)

LSA, 322 ft cylindrical STRONG TICllT (55 gal drums),

container 128 ft3 wooden boxes 5.

Solidification Agent (la)

Urea-formaldehyde B.

IRRADIATED FUEL SHIPMENTS (Disposition)

{

Number of Shipments Mode of Transportation Destination None N/A N/A

Table 4A CONTINUOUS RELEASE HODE QUARTER t 3 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 )

9-30-80 STABILITY CLASS A

ELEVATION 45.7n Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

i NE O

O O

0-0 0

0 ENE O

O O

O O

O O

E O

O O

O O

O O

i --

ESE 0

0 0

0 0

0 0

SE O

O O

O O

O O

SSE O

O O

O O

0 0

S 0

0 0

0 0

0 0

l SSW 0

0 0

0 0

0 0

SW 0

0 1

0 0

0 i

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE 3

4 0

0 0

i 8

0 0

1 0

0 0

i Total Periods of caln(hetrs).

3 Hours of missing data 0

l 4

9 1

l Table 4A CONTINUOUS RELEASE MODE QUARTER 4 3 HOURS AT EACH WIND SPEED AND DIRECTION l

PERIOD OF RECORD:

7 -i-80 )

9-30-80 4

STABILITY CLASS: A ELEVATION 10.0M

_______---___---______--_==-- - -__--________________---__---__--__-_-_________

Wind Speed (nph) at 10.0n level Wind Direction i-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE 3

0 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE 4

4 i

6 0

0 9

0 0

0 0

0 0

0 Total Periods of caln(hours):

3 Havrs of missing datas 0

i l

e i

l Table 4A CONTINUOUS RELEASE MODE QUARTER t 3 I

HOURS AT EACH WIND SPEED AND DIRECTION

?

PERIOD OF RECORD:

7 80 }

9-30-80 STABILITY CLASS: B ELEVATION:4S.7n l

Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 O

i 0

0 0

i NNE O

O O

O O

O O

1 NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

1-ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 1

0 0

0 i

VARIABLE O

O 2

0 0

0 2

0 0

2 0

0 0

2 Total Periods of caln(hours):

0 Hours of missing datas 0

e

Table 4A CONTINUOUS RELEASE MODE QUARTER # 3 l

HOURS AT EACH WIND SPEED AND DIRECTION i

l PERIOD OF RECORD:

7 -i-80 )

9-30-80 STABILITY CLASS: B ELEVATION:10.On Wind Speed (mph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL i

N 0

0 0

0 0

0 0

NNE O

O O

O O

O O

NE O

i i

0 0

0 2

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

r --

SE O

O i

0 0

0 i

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0'

0 0

NNW 0

0 0'

0 0

0 0

VARIABLE O

O i

0 0

0 1

- - - - - - - - - - - - - - - - - - - - - - - = = - - = = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ _ - --

0 1

2 0

0 0

3 W

Total Periods of caln(hours):

0 Hours of missing data 0

s

I Table 4A CONTINUGUS RELEASE MOL QUARTER t 3 HOURS AT EACH WIND SPEED AND DIRECTION 4

PERIOD OF RECORD:

7 80 )

9-30-80 STABILITY CLASS: C

{

ELEVATIONi45.7m Wind Speed (mph) at 45.7n level Wind 1

Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

1 0

0 0

i NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

i 0

1 0

0 2

E O

O O

O O

O O

4h-ESE O

O O

O O

O O

SE O

O O

O O

O 0

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

1 0

0 0

0 i

WSW 0

0 0

0 0

0 0

W 0

C i

0 0

0 i

WNW 0

0 2

0 0

0 2

NW 0

0 2

0 0

0 2

i NNW 0

0 1

0 0

0 i

VARIABLE O

3 8

i 0

0 12


==- =_

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - = = - -_ _-----

0 2

7 i

0 0

10 Total Periods of caln(hours):

0 Hours of missing data:

0 1

?

v

k l

Table 4A-l l

l l

CONTINUOUS RELEASE MODE QUARTER 4 3 l

r HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 -i-80 )

9-30-80 l

STABILITY CLASS C

ELEVATION:10.0m Wind Speed (mph) at 10.0m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

3 0

0 0

3 NNE O

O O

O O

O O

NE O

O i

0 0

0 i

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

i 0

0 0

0 i

SE O

O i

0 0

0 i

SSE O

O O

O 0

0 0

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

1 0

0 i

W D

0 0

0 0

0 0

9 WNW 0

0 0

0 0

0 0

NW 0

0 1

0 0

0' i

NNW 0

1 0

0 0

0 i

VARIABLE O

7 6

0 0

0 13 0

2 6

1 0

0 9

Total Periods of calm (hours):

0 Hours of missing data 0

t

1 Table 4A CONTINUOUS RELEASE MODE QUARTER 4 3 HOURS AT EACH WIN,D SPEED AND DIRECTION PERIOD OF RECORD:

7 -i-80 3 9-30-80 STABILITY CLASS: D ELEVATION 45.7m Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 i3-18 19-24

>24 TOTAL N

2 14 3

0 0

0 19 NNE i

4 3

i 0

0 9

NE O

10 10 1

0 0

21 ENE i

19 8

3 0

0 31 E

2 13 3

0 0

0 18 ESE O

12 5

0 0

0 17 SE i

5 3

2 0

0 11 SSE 2

4 0

0 0

0 6

S 4

7 i

i 0

0 13 SSW D

6 10 0

0 0

16 SW i

4 5

1 0

0 11 WSW i

17 3

0 0

0 21 W

0 9

10 0

0 0

19 WNW 3

13 27 i

0 0

44 NW i

3 9

0 0

0 13 NNW i

4 3

0 0

0 8

VARIABLE 60 343 137 18 i

0 559 20 144 103 10 0

0 277 Total Periods of caln(hours):

0 Hours of missing data s 0

i Table 4A

[

t CONTINU0US RELEASE MODE QUARTER

  • 3 t

HOURS AT EACH WIND SPEED AND DIRECTION t

i PERIOD OF RECORD:

7 -i-80 }

9-30-80 STABILITY CLASS: D ELEVATION:10.On i

Wind Speed (mph) at 10.0n level Wind I

Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 14 10 0

0 0

24 NNE i

8 4

0 0

0 13 NE 4

9 0

0 0

0 13 ENE 2

7 0

0 0

0 9

E 2

12 4

0 0

0 18 ESE 3

20

~ i0 0

0 0

33 SE i

8 3

0 0

0 12 SSE 2

15 i

0 0

0 18 S

4 5

i 0

0 0

10 SSW 2

5 0

0 0

0 7

SW 2

i i

0 0

0 4

WSW 0

6 4

0 0

0 10 W

i 4

3 1

0 0

9 WNW 5

9 2

0 0

0 16 NW 2

12 2

0 0

0 16 NNW i

24 10 0

0 0

35 VARIABLE 87 404 93 4

0 0

588 i

32 159 55 1

0 0

247 Total l

Periods of caln(hours):

i Hours of missing data s 0

r i

l I

i I

l

Table 4A CONTINUOUS RELEASE MODE QUARTER

  • 3 HOURS _AL.EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 -i-80 3 9-30-80 STABILITY CLASS: E ELEVATIONS 45.7m Wind Speed (mph) at 45.7m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

O 2

6 0

0 0

8 NNE i

3 2

0 0

0 6

NE i

11 12 0

0 0

24 ENE i

22 15 0

0 0

38 E

2 15 7

0 0

0 24 ESE 2

6 8

0 0

0 16 1-SE o

4 2

1 0

0 10 SSE O

i 4

0 0

0 5

S i

i 7

0 0

0 9

SSW i

17 13 1

0 0

32 SW 2

25 28 2

0 0

57 WSW 0

18 4

0 0

0 22 W

i 10 9

0 0

0 20 WNW 0

5 4

0 0

0 9

NW 0

i 6

0 0

0 7

NNW 0

4 3

2 0

0 9

VARIABLE 89 267 130 12 i

0 499 15 145 130 6

0 0

296 Total Periods of calm (hours):

3 Hours of missing data s 0

Table 4A CONTINUGUS RELEASE MODE QUARTER 4 3 ij __

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 3 9-30-80 STABILITY CLASS: E ELEVATION:10.On Wind Speed (mph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

5 3

0 0

0 0

8 NME 7

7 0

0 0

0 14

.4 E i

4 1

0 0

0 6

ENE 5

1 0

0 0

0 6

E 3

6 0

0 0

0 9

w--

ESE 9

13 0

0 0

0 22 SE 8

6 0

0 0

0 14 SSE 3

6 0

0 0

0 9

S 2

7 2

0 0

0 11 SSW 0

2 2

0 0

0 4

SW i

5 0

0 0

0 6

WSW i

4 2

0 0

0 7

W 14 37 5

0 0

J 56 WNW 12 11 2

0 0

0 25 NW 13 3

0 0

0 0

16 NNW 6

5 0

0 0

0 11 VARIABLE 289 227 24 0

0 0

540

___________________________________________=

=--- ____________________________

90 120 14 0

0 0

224 Total Periods of caln(hours):

34 Hours of missing data 0

l 4

Table 4A CONTINUOUS RELEASE NODE QUARTER 4 3 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 )

9-30-80 STABILITY CLASS: F ELEVATION:45.7M Wind Speed (nph) at 45.7m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

2 2

3 0

0 0

7 NNE O

2 1

0 0

0 3

NE O

7 2

0 0

0 9

ENE O

4 5

0 0

0 9

E O

7 0

0 0

0 7

ESE 2

8 4

0 0

0 14 SE i

i 7

0 0

0 9

SSE O

4 0

0 0

0 4

S i

3 1

0 0

0 5

SSW i

4 4

0 0

0 9

SW 0

7 3

0 0

0 10 WSW 2

9 1

0 0

0 12 W

0 12 2

0 0

0 14 WNW i

2 1

1 0

0 5

NW 2

6 1

0 0

0 9

NNW 0

4 i

0 0

0 5

VARIABLE 60 152 49 0

1 0

262


_----___----_----------------_---_--_=

_ _=_-----___---------_-_--_-_--_-.

12 82 36 1

0 0

131 Total Periods of caln(hours):

6 Hours of missing datas 0

i e

l l

i Table 4A CONTINUOUS RELEASE MODE QUARTER

  • 3 HOURS AT EACH WIND SPEED AND DIRECTION t

PERIOD OF RECORD:

7 -i-80 3 9-30-80 STABILITY CLASS: F ELEVATION:10.DM Wind Speed (aph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL t

N 11 1

0 0

0 0

12 I NNE 9

1 0

0 0

0 10 !

NE 3

0 0

0 0

0 3

ENE 4

0 0

0 0

0 4

E 4

0 0

0 0

0

'4 ESE 7

0 0

0 0

0 7

SE i

0 0

0 0

0 i ~

SSE 4

0 0

0 0

0 4

S 2

2 0

0 0

0 4

SSW 2

0 0

0 0

0 2

SW 3

1 0

0 0

0 4

WSW 2

1 0

0 0

0 3 ;

W 6

3 0

0 0

0 9

WNW 6

0 0

0 0

0 6

NW 6

0 0

0 0

0 6

NNW 5

0 0

0 0

0 5

VARIABLE 217 31 i

1 0

0 250 l 75 9

0 0

0 0

84 Total Periods of caln(hours):

65 Hours of missing data 0

l l

s

l Table 4A CONTINUOUS RELEASE MODE QUARTER 1 3 l

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 3 9-30-80 STABILITY CLASS: G ELEVATION:45.7m L'ind Speed (mph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-B 19-24

>24 TOTAL N

O 4

i 0

0 0

5 NNE i

4 4

0 0

0 9

NE i

4 5

0 0

0 10 ENE O

6 0

0 0

0 6

E i

5 i

0 0

0 7

EFE O

2 0

0 0

0 2

O 6

0 0

0 0

6 1

0 0

1 0

0 0

1

~

2 i

0 0

0 0

3 bdW 0

1 0

0 0

0 i

SW i

5 i

0 0

0 7

WSW i

7 0

0 0

0 8

W 2

0 1

0 0

0 3

WNW D

2 0

0 0

0 2

NW 2

3 0

0 0

0 5

NNW 0

1 2

0 0

0 3

VARIABLE 16 28 12 0

0 0

56 11 51 16 0

0 0

78 Total Periods of caln(hours):

3 Hours of Missing datai 0

l l

i Table 4A CONTINUOUS RELEASE MODE QUARTER 43 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 )

9-30-80 STAEILITY CLASS: G ELEVATION 10.On Wind Speed (mph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

9 i

0 0

0 0

10 NNE 14 3

0 0

0 0

17 NE 9

0 0

0 0

0 9

ENE 5

0 0

0 0

0 5

E 5

0 0

0 0

0 5

ESE 2

0 0

0 0

0 2

x_-

SE 3

0 0

0 0

0 3

SSE i

0 0

0 0

0 i

S i

i 0

0 0

0 2

SSW i

0 0

0 0

0 i

SW i

0 0

0 0

0 i

WSW 4

0 0

0 0

0 4

W i

0 0

0 0

0 i

WNW 2

0 0

0 0

0 2

NW i

0 0

0 0

0 i

NNW 3

0 0

0 0

0 3

VARIABLE 57 2

0 0

0 0

59

- -. - - - - - - - - - - - - - - - - - - _ _ = - - - _ = - - - - - - - - - - - - - - - - _ -

== -------------------..-.

62 5

0 0

0 0

67 Total Periods of calm (hours):

ii Hours of missing datai 0

Table 4A BATCH RELEASE MODE QUARTER 9 3 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 )

9-30-80 STABILITY CLASS: A ELEVATION:45.7m Wind Speed (nph) at 4S.7m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TGTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

1 0

0 0

ESE O

O O

?

O O

O SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW D

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 Hours of missing data 0

)

i i

l

I l

i Table 4A 1

I l

l BATCH RELEASE MODE QUARTER

  • 3 l

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 }

9-30-80 STABILITY CLASS: A ELEVATION:10.On Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE 0

0 0

0 0

0 0

S 0

0 J

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VAR I ABLE O

O O

O O

O O

- -.. - - - - - - - - - - - - - - - - - _ - _ _ _ _ = = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 Hours of missing datas 0

Table 4A BATCH RELEASE MODE QUARTER t 3 HOURS AT EACH WIND SPEED AND DIRECTION i

PERIOD OF RECORD:

7 80 3 9-30-80 STABILITY CLASS: B r

ELEVATION:45.7n Wind Speed (mph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

l ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O 0

0 0

SE O

O O

O O

O 0

c-SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

l W

0 0

0 0

0 0

0 WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total t

Periods of caln(hours):

0 Hours of missing data, 0

t 4

I Table 4A i

BATCH RELEASE MODE QUARTER 4 3 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 }

9-30-80 STABILITY CLASS: B ELEVATION:10.On Win'd Speed (mph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

t 0

0 0

0 0

0 NNE O

O 0

0 0

0 0

l NE O

O O

O O

O O

ENE 0

0 0

0 0

0 0

i E

O O

O O

O O

O ESE O

O O

O O

O O

l SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

j SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total i

Periods of caln(hours):

0 Hours of missing data 0

)

l i

I

l i

i Table 4A I

L BATCH RELEASE MODE QUARTER t 3 I

i HOURS AT EACH WIND SPEED AND DIRECTION

[

PERIOD OF RECORD:

7 -i-80 )

9-30-80

[

STABILITY CLASS: C l

ELEVATION 45.7n j

Uind Speed (mph) at 45.7m le9e1 f

Wind i

Direction 1-3 4-7 8-12 13-18 19-24

)24 TOTAL N

O

'c 0

0 0

0 0

NNE O

O O

O 0

0 0

(

NE O

O O

O O

O O

l ENE O

O O

O O

O O

i E

O O

O O

O O

O ESE O

O O

O O

O O

SE O

O O

O O

O O

3 SSE O

O O

O O

0 0

l S

0 0

0 0

0 0

0 l

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

[

WNW 0

0 0

0 0

0 0

4 NW 0

0 0

0 0

0 0

i NNW G

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

6 Total Periods of cain(hours):

0 Hours of missing data 0

e I

I I

lable 4A BATCH RELEASE MODE QUARTER

  • 3 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 80 3 9-30-80 STABILITY CLASS: C ELEVATION:10.On


==--

Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O 0

0 0

0 0

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 Hours of missing data-0

i Table 4A BATCH RELEASE MODE QUARTER 4 3 i

HOURS AT EACH WIND SPEED AND DIRECTION i

i PERIOD OF RECORD:

7 80 )

9-30-80 STABILITY CLASS: D ELEVATION:45.7n Wind Speed (nph) at 45.7m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL t

N 0

0 0

0 0

0 0

l NNE O

O O

0 0

0 0

i NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE i

i 0

0 0

0 2

SSE O

O O

O O

O O

S i

i 0

0 0

0 2

i SSW 0

1 0

0 0

0 i

SW i

0 0

0 0

0 i

t WSW 0

3 0

0 0

0 3

W 0

0 0

0 0

0 0

WNW 0

1 0

0 0

0 i

i NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

3 7

0 0

0 0

10 Total Periods of caln(hours):

0 Hours of missing datas 0

1 9

[

l i

e

Table 4A j

BATCH RELEASE MODE QUARTER 1 3 l

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

7 -i-80 3 9-30-80 STABILITY CLASS: D ELEVATION 10.0m Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S i

0 0

0 0

0 i

SSW 0

1 0

0 0

0 i

SW 2

0 0

0 0

0 2

WSW 0

1 0

0 0

0 i

W 0

0 0

0 0

0 0

WNW 3

1 0

0 0

0 4

NW 0

0 0

0 0

0 0

NNW i

0 0

0 0

0 i

VARIABLE O

O O

O O

O O

7 3

0 0

0 10 Total Periods of caln(hours):

0 Hours of missing datas 0

l j

a m

Table 4A BATCH RELEASE MODE QUARTER t 3 HOURS AT EACH WIND SPEED AND DIRECTION f

l PERIOD OF RECORD:

7 80 }

9-30-80 STABILITY CLASS: E ELEVATION 4S.7m Wind Speed (eph) at 4S.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O i

0 0

0 i

E O

i 0

0 0

0 i

ESE O

O O

O O

O O

SE O

i 0

0 0

0 i

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

i i

0 0

0 2

i SW 0

1 0

0 0

0 i

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

'JNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 4

2 0

0 0

6 Total Periods of caln(hours):

0 Hours of missing data:

0 h

i i

l l

i i

Table 4A BATCH RELEASE MODE QUARTER *3 HOURS AT EACH WIND SPEED AND DIRECTION r

PERIOD OF RECORD:

7 80 3 9-30-80 STABILITY CLASS: E ELEVATION:10.On Wind Speed (nph) at 10.On level i

Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESF i

i 0

0 0

0 2

SE O

O O'

0 0

0 0

SSE O

O O

O O

O O

S i

0 0

0 0

0 i

SSW 0

0 0

0 0

0 0

SW D

0 0

0 0

0 0

WSW i

0 0

0 0

0 i

W i

0 0

0 0

0 i

WNW 0

1 0

0 0

0 i

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

4 2

0 0

0 0

6 Total Periods of caln(hours):

0 Hours of missing data 0

5 i

l l

l Table 40 BATCH RELEAS.' dODE QUARTER 4 3 t

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD 7 -i-80 }

9-30-80 STABILITY CLASS: F ELEVATION 45.7m Wind Speed (mph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL i

N 2

1 0

0 0

0 3

NNE O

O i

0 0

0 i

NE O

i 0

0 0

0 i

ENE O

O 2

0 0

0 2

t E

O i

0 0

0 0

i ESE O

O O

O O

O O

l SE O

O O

O O

O O

[

SSE O

i 0

0 0

0 i

S 0

1 0

0 0

0 i

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

i W

0 0

0 0

0 C

0 t

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

f 2

5 3

0 0

0 10 Total Periods of caln(hours):

0 Hours of missing data:

0 s

1

Table 4A BATCH RELEASE MODE QUARTER 43 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD C I# CORD:

7 -i-80 )

9-30-80 STABILITY CLASS: F ELEVATION:10.0m Wind Speed (mph) at 10.0m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

3 0

0 0

0 0

3 NNE O

O O

O O

O O

NE i

0 0

0 0

0 i

ENE i

0 0

0 0

0 i

E i

0 0

0 0

0 i

ESE 2

0 0

0 0

0 2

SE O

O O

0 0

0 0

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 2

0 0

0 0

0 2

USW 0

0 0

0 0

0 0

W D

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

10 0

0 0

0 0

10 Total Periods of calm (hours):

0 Hours of missing data 0

1 1

Table 4A BATCH RELEASE MODE QUARTER 43 HOURS AT EACH WIND SPEED AND DIRECTION 1

PERIOD OF RECORD:

7 80 )

9-30-80 STABILITY CLASS: G ELEVATION 45.7m Wind Speed (nph) at 45,7m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 1

0 0

0 0

i i

NNE 0

0 1

0 0

0 1

NE O

O O

O O

O O

j ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

'i -

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

4 WSW 0

0 0

0 0

0 0

1 W

0 0

0 0

0 0

0

'JNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

O i

1 0

0 0

2 i

Total Periods of caln(hours):

0 Hours of nissing data 0

)

l 1

Table 4A BATCH RELEASE MODE QUARTER S 3 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD'OF RECORD:

7 80 )

9-30-80 STABILITY CLASS: G ELEVATION:10,0n Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE 2

0 0

0 0

0 2

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

0 0

0 0

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O J

0 0

2 0

0 0

0 0

2 Total Periods of caln(hours):

0 Hours of missing data 0

i F

Table 4A i

CONTINUOUS RELEASE MODE QUARTER 4 4 HOURS AT EACH WIND SPEED AND DIRECTION i

PERIOD OF RECORD: 10 -i-80 3 12-31-80 STABILITY CLASS: A ELEVATION 45.7m

[

Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

2 4

2 0

0 0

8 NNE 2

1 3

0 0

0 6

NE 2

2 16 i

0 0

21 ENE O

7 3

0 0

0 10 E

O 3

0 0

0 0

3 ESE i

1 0

0 0

0 2

SE O

i 0

0 0

0 i

SSE O

4 6

0 0

0 10 S

i 3

21 3

0 0

28 SSW 4

7 4

0 0

0 15 SW 2

6 4

0 0

0 12

~

WSW 4

9 i

0 0

0 14 W

3 13 7

0 0

0 23 WNW 0

3 8

0 0

0 11 NW 4

5 26 8

0 0

43 NNW 2

8 33 2

0 0

45 VARIABLE 28 53 33 5

0 0

119 27 77 134 14 0

0 252 l

Total Periods of caln(hours):

7 Hours of missing datas 0

Table 4A CONTINUOUS RELEASE MODE QUARTER 4 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 00 ) 12-31-80 STABILITY CLASS: A ELEVATION 10.On Wind Speed (mph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

15 13 8

0 0

0 36 NNE 15 20 15 0

0 0

50 NE 14 9

2 0

0 0

25 ENE i

i 0

0 0

0 2

E i

0 0

0 0

0 i

ESE i

2 1

0 0

0 4

SE 2

0 0

0 0

0 2

SSE i

1 0

0 0

0 2

S i

2 0

0 0

0 3

SSW 8

2 0

0 0

0 10 SW 15 9

2 0

0 0

26 WSW 4

12 7

0 0

0 23 W

3 i

0 0

0 0

4 WNW 3

6 0

0 0

0 9

NW 5

9 0

0 0

0 14 NNW 2

7 2

0 0

0 11 VARIABLE 60 57 13 0

0 0

130 91 94 37 0

0 0

222 Total Periods of caln(hours):

26 Hours of missing datas 0

l i

Table 4A l

i CONTINU0US RELEASE MODE QUARTER t 4 i

i HOURS AT EACH WIND SPEED AND DIRECTION i

PERIOD OF RECORD: 10 80 } 12-31-80 STABILITY CLASS: B ELEVATIONi45.7m Wind Speed (mph) a t 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL j

N 0

0 0

0 0

0 0

t NNE 0

0 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O 0

0 0

0 0

E O

O 0

0 0

0 0

i ESE O

O O

O 0

0 0

SE O

O O

O O

O O

SSE O

0 0

0 0

0 0

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

[

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

l W

0 0

0 0

0 0

0 WNW 0

0 0

0 0

0 0

~

NW 0

0 0

0 0

0 0

L NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

O O

O O

O O

O Total Periods of caln(hours):

i Hsurs of missing datai 0

.n,

I f

l l

l Table 4A I

CONTINUOUS RELEASE NODE QUARTER # 4 l

l 1 -

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 } 12-31-80 STABILITY CLASS: B ELEVATION 10.On Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE 0

0 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE 0

0 0

0 0

0 0

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W i

0 0

0 0

0 i

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE 0

0 0

0 0

0 0

i 0

0 0

0 0

i Total Periods of caln(hours):

0 Hours of missing data s 0

\\

i Table 4A I

CONTINUOUS RELEASE NODE QUARTER # 4 i

~

HOURS AT EACH WIND SPEED AND DIRECTION i

t PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: C ELEVATIONi45.7m

{

Wind Speed (mph) at 45.7m level Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL i

N 0

0 0

0 0

0 0

l NNE O

O O

O O

O O

NE O

0 0

0 0

0 0

ENE 0

0 0

0 0

0 0

E O

O G

0 0

0 0

ESE 0

0 0

0 0

0 0

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

i SSW 0

1 0

0 0

0 i

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE i

0 1

0 0

0 2

0 1

0 0

0 0

i Total Pcriods of cal.1(hours):

0 Hours of missing datas 0

A Table 4A CONTINU0US RELEASE MODE QUARTER 9 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: C ELEVATIONii0.0m Wind Speed (mph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NF 0

0 0

0 0

0 0

ENE O

O 0

0 0

0 0

E O

O O

O O

O O

ESE O

O 0

0 0

0 0

,y-SE O

O O

O O

O O

SSE O

O 0

0 0

0 0

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

1 0

0 0

0 i

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE i

0 1

0 0

0 2

0 1

0 0

0 0

i Total Periods of caln(hours):

0 Hours of missing data i 0

Table 4A CONTINUOUS RELEASE MODE QUARTER t 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: D ELEVATIONi45.7m Wind Speed (mph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 3

6 4

0 0

13 NNE O

O 6

0 0

0 6

NE O

i 0

0 0

0 i

ENE O

2 0

1 0

0 3

E O

O 2

0 0

0 2

ESE O

i 5

0 0

0 6

SE O

O 5

0 0

0 5

SSE O

O O

O O

O O

S 0

0 0

2 0

0 2

SSW 0

0 2

0 0

0 2

SW 0

0 0

0 0

0 0

WSW 0

0 i

i 0

0 2

W 0

1 2

3 0

0 6

WNW 0

i 7

2 2

0 12 NW 0

0 4

7 5

0 16 NNW 0

5 7

5 1

0 18 VARIABLE 12 62 86 27 6

0 193 i

0 14 47 25 8

0 94 Total Periods of caln(hours):

0 Hours of nissing data 0

Table 4A CONTINUOUS RELEASE MODE QUARTER 44 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: E ELEVATION 45.7m Wind Speed (nph) at 45,7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 4

11 0

0 0

15 NNE O

i 2

0 0

0 3

NE O

O 5

0 0

0 5

ENE O

2 8

2 1

0 13 E

O 4

9 4

0 0

17 ESE O

2 8

1 0

0 11 SE i

3 3

5 0

0 12 SSE O

4 6

1 0

0 11 S

0 4

3 1

0 0

8 SSW 0

i 6

i 0

0 B

SW 0

1 0

0 0

0 i

WSW i

3 3

0 0

0 7

W 0

3 ii 0

0 0

14 WNW 0

4 15 9

i 0

29 NW 0

2 28 8

3 0

41 NNW 2

6 13 1

0 0

22 VARIABLE 23 120 147 25 0

0 315 4

44 131 33 5

0 217 Total Periods of caln(hours):

i Hours of missing data 0

f Table 4A CONTINU0US RELEASE MODE QUARTER 4 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 ) 12-31-80 STABILITY CLAGS: D ELEVATION 10.On Wind Speed (mph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

O 3

6 3

0 0

12 NNE O

i 10 4

0 0

15 NE O

2 4

0 0

0 6

ENE O

3 2

0 0

0 5

E O

2 1

0 0

0 3

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

3 1

0 0

0 4

S 0

2 7

0 0

0 9

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

2 i

0 0

0 3

WNW 0

0 0

0 0

0 0

NW 0

1 0

0 0

0 i

NNW 0

2 7

2 0

0 11 VARIABLE 11 113 83 ii 0

0 218 0

21 39 9

0 0

69 Total Periods of caln(hours):

0 Haurs of missing data s 0

Table 4A CONTINUQUS RELEASE MODE QUARTER #4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 3 12-31-80 STABILITY CLASS: F ELEVATION:45.7m Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

i 0

0 0

0 0

i NNE O

i 2

0 0

0 3

NE O

3 ii 2

0 0

16 ENE O

5 12 2

0 0

19 E

O i

5 0

0 0

6 g_

ESE O

O i

0 0

0 i

SE i

1 0

0 0

0 2

SSE O

O O

O O

O O

i S

0 3

2 0

0 0

5 SSW 0

0 5

1 0

0 6

SW 0

i 5

0 0

0 6

WSW 0

2 0

0 0

0 2

W 0

0 3

0 0

0 3

WNW 0

2 10 1

0 0

13 NW 0

5 21 1

0 0

27 NNW 0

i 12 i

0 0

14 VARIABLE 16 62 72 14 0

0 164 2

25 89 8

0 0

124 Total Pariods of caln(hours):

2 Hours of missing data s 0

1

Table 4A CONTINUOUS RELEASE MODE QUARTER

  • 4 i

HOURS AT EACH WIND SPEED AND DIRECTION r

PERIOD OF RECORD: 10 -i-80 } 12-31-80 STABILITY CLASS: E ELEVATIONiiO.On

(

Wind Speed (mph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

3 21 16 3

0 0

43 NNE 4

14 5

0 0

0 23 NE O

7 0

0 0

0 7

ENE O

O O

O O

O O

E 2

4 2

0 0

0 8

i 3-ESE O

i i

0 0

0 2

SE i

6 10 0

0 0

17 SSE O

7 1

0 0

0 8

S 0

5 5

0 0

0 10 SSW 0

5 2

0 0

0 7

SW i

i i

0 0

0 3

WSW i

3 1

0 0

0 S

W 0

7 i

0 0

0 8

WNW 0

1 0

0 0

0 1

NW i

2 0

0 0

0 3

NNW 4

6 9

0 0

0 19 t

VARIABLE 97 190 70 3

0 0

360 17 90 54 3

0 0

164 Total Pariods of caln(hours):

9 Hours of missing datai 0

L

Table 4A

)

CONTINU0US RELEASE MODE QUARTER t 4 i

i HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: F ELEVATION 19.On Wind Speed (nph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

4 13 0

0 0

0 17 NNE i

13 4

0 0

0 18 NE O

O i

0 0

0 i

ENE O

O O

O O

O O

E 0

0 0

0 0

0 0

ESE O

9 8

0 0

0 17 SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW D

0 0

0 0

0 0

Su i

0 0

0 0

0 i

WSW 0

0 0

0 0

0 0

W 0

1 0

0 0

0, i

WNW i

0 0

0 0

0 i

NW 0

1 0

0 0

0 i

NNW 4

10 0

0 0

0 14 VARIABLE 95 90 23 0

0 0

208 ii 47 13 0

0 0

71 Total Periods of caln(hours):

ii Hours of missing datai 0

Table 4A CONTINUOUS RELEASE MODE QUARTER

  • 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: G ELEVATIONi45.7m Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 15 36 i

0 0

52 NNE O

4 14 1

0 0

19 NE O

3 32 5

0 0

40 ENE i

4 15 0

0 0

20 E

O 2

5 0

0 0

7 ESE O

2 1

0 0

0 3

SE i

4 1

0 0

0 6

SSE O

3 1

0 0

0 4

S 0

2 4

0 0

0 6

SSW 0

4 2

0 0

0 6

SW 0

1 6

0 0

0 7

WSW i

3 1

0 0

0 5

W i

5 1

0 0

0 7

WNW 0

6 5

5 0

0 16 NW i

6 23 1

0 0

31 NNW 0

14 39 2

0 0

55 VARIABLE 52 159 204 2

0 0

417 5

78 186 15 0

0 284 Total Periods of caln(hours):

15 Hours of missing datas 0

4

L l

l

?

l:

Table 4A i

e CONTINUOUS RELEASE MODE QUARTER t 4 4

HOURS AT EACH WIND SPEED Ai1D DIRECTION PERIOD OF RECORD: 10 -i-80 ) 12-31-80 STABILITY CLASS: G ELEVATION:10.On Wind Speed (mph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

20 5

0 0

0 0

25 NNE 35 24 5

0 0

0 64 NE 7

26 2

0 0

0 35 ENE 4

7 2

0 0

0 13 E

i i

6 0

0 0

8 ESE i

6 7

0 0

0 14 SE O

O O

O O

O O

SSE i

0 0

0 0

0 i

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW i

0 0

0 0

0 i

WSW 2

0 0

0 0

0 2

W D

0 0

0 0

0 0

WNW 0

1 0

0 0

0 1

NW 0

1 0

0 0

0 i

NNW 15 4

0 0

0 0

19 VARIABLE 276 146 37 0

0 0

457 87 75 22 0

0 0

184 Total Periods of caln(hours):

73 Hours of missing datas 0

I t

4 j

Table 4A i

BATCH RELEASE MODE QUARTER

  • 4 f

s HOURS AT EACH WIND SPEED AND DIRECTION i.

PERIOD OF RECORD: 10 80 3 12-31-80 l

STABILITY CLASS: A ELEVATION 45.7m i

Wind Speed (mph) at 4S.7m level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 i

i 0

0 0

2 NNE O

.i 0

0 0

0 i

NE O

i 10 1

0 0

12 I

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

O 9

SSE O

i 0

0 0

0 i

i S

0 0

0 0

0 0

0 SSW i

i 0

0 0

0 2

SW 0

2 1

0 0

0 3

WSW i

3 0

0 0

0 4

W 0

5 i

0 0

0 6

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

1 0

0 0

0 i

VARIABLE 11 13 6

0 0

0 30 2

16 13 1

0 0

32 Toval Periods of caln(hours):

i Hours of missing datas 0

l

Table 4A BATCH RELEASE MODE QUARTER 4 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 ) 12-31-80 STABILITY CLASS: A ELEVATION 10.On Wind Speed (mph) at 10.0n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

i 0

0 0

0 0

i NNE O

O O

O O

O O

NE 4

i 0

0 0

0 5

ENE O

O O

O O

O O

E i

0 0

0 0

0 i

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW i

0 0

0 0

0 i

SW 4

0 0

0 0

0 4

WSW i

0 0

0 0

0 i

W 2

0 0

0 0

0 2

WNW i

0 0

0 0

0 i

NW i

0 0

0 0

0 1

NNW i

0 0

0 0

0 i

VARIABLE 26 ii 0

0 0

0 37 17 i

0 0

0 0

18 Total Periods of caln(hours):

8 Hours of missing datas 0

I r

i Table 4A BATCH RELEASE MODE QUARTER 4 4 i

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 ) 12-31-80 STABILITY CLASS: B ELEVATION:4U.7n Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL i

l N

O O

O O

O O

O NNE 0

0 0

0 0

0 0

NE O

O O

O O

0 0

ENE 0

0 0

0 0

0 0

E O

O C

0 0

0 0

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

l W

0 0

0 0

0 0

0 WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total Periods of caln(hours) 0 Hours of missing datas 0

4

Table 4A i

BATCH RELEASE MODE QUARTER

  • 4 HOURS AT EACH WIND SPEED AND DIRECTION 1

PERIOD OF RECORD: 10 -i-80 } 12-31-80 f

STABILITY CLASS: B ELEVATION 10.On Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

0 0

ESE D

0 0

0 0

0 0

S F.

0 0

0 0

0 0

0 SSE' O

O O

O O

O O

t 0

0 0

0 0

0 0

SLW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 Hours of missing data:

0

\\

i

Table 4A BATCH RELEASE MODE QUARTER 4 4 r

HOURS AT EACH WIND SPEED AND DIRECTION

~

PERIOD OF RECORD 10 -i-80 ) 12-31-80 STABILITY CLASS: C ELEVATION:4S.7n Wind Speed (nph) at 4S.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL l

l N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

0 0

0 0

0 0

E O

O O

O O

O 0

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE D

0 0

0 0

0 0

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 i

Hours of missing datas 0

i i

i Table 4A t

t BATCH RELEASE MODE QUARTER

  • 4 t

HOURS AT'EACH WIND SPEED AND DIRECTION i

PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: C t

ELEVATION:10.On Wind Speed (nph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

0 0

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 Hours of missing datas 0

i

Table 4A BATCH RELEASE MODE QUARTER

  • 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 } 12-31-80 STADILITY CLASS: D ELEVATION 45.7n Wind Speed (nph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

l E

O O

O O

O O

O ESE 0

0 0

0 0

0-0 SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

1 0

0 i

VARIABLE O

i 5

1 0

0 7

0 0

0 1

0 0

i Total Periods of caln(hours):

0 Hours of missing datas 0

G

[

I

Table 4A BATCH RELEASE MODE QUARTER t 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: D ELEVATIONi10.On Wind Speed (mph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 O

i 0

0 0

i NNE 0

0 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O O

O O

0 0

E O

O O

O O

O O

ESE O

O O

O O

0 0

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW D

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

3 4

0 0

0 7

0 0

1 0

0 0

i Total Periods of caln(hours):

0 Hours of missing data:

0 i

)

Table 4A BATCH RELEASE MODE QUARTER # 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 -i-80 ) 12-31-80 STABILIT( CLASS: E ELEVATION 4S.7n Wind Speed (mph) at 45.7n leuel Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE 0

0 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O 0

0 0

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O 2

0 0

0 2

0 0

0 0

0 0

0 Total Periods of caln(hours):

0 Hours of Missing data 0

e

I i

Table 4A BATCH RELEASE MODE QUARTER 4 4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD 10 80 } 12-31-80 STABILITY CLASS: E j

ELEVATION 10.0m i

Wind Speed (mph) at 10.0m level Wind i

Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE 0

0 1

0 0

0 i

NE O

O O

O O

O 0

ENE O

O O

O O

O O

E O

O O

O O

O O

i ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

l NNW 0

0 0

0 0

0 0

VARIABLE O

i 0

0 0

0 i

0 0

1 0

0 0

i Total Periods of calm (hours):

0 Hours of missing datas 0

i l

~ - - - - -

t 7__

Table 4A l

BATCH RELEASE MODE QUARTER #4

' ~

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS F

ELEVATION 45.7n i

Wind Speed (mph) at 45.7n level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

l ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

i -

NNW 0

0 5

1 0

0 6

VARIABLE O

O 2

0 0

0 2

0 0

5 1

0 0

6 Total

[

Periods of caln(hours):

0 Hours of missing datas 0

[

n 4

Table 4A BATCH RELEASE MODE QUARTER # 4 HOURS AT CACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 STABILITY CLASS: F ELEVATION 10.On Wind Speed (mph) at 10.On level Wind

)

Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL 2

N 0

0 0

0 0

0 0

NNE i

5 0

0 0

0 6

NE O

O O

O O

O 0

ENE 0

0 0

0 0

0 0

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

2 0

0 0

0 2

i 5

0 0

0 0

6 Total Periods of caln(hours):

0 Hours of missing datas 0

l i

Table 4A

[

BATCH RELEASE NODE QUARTER 44 i

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 } 12-31-80 STABILITY CLASS G

ELEVATIONi4S.7m Wind Speed (nph) at 45.7m level Wind Direction 1-3 4-?

8-12 13-18 19-24

> 24, TOTAL N

0 0

0 0

0 0

0 NNE d

0 0

0 0

0 0

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

0 0

0 0

SE O

O O

O O

O 0

SSE O

O O

O O'

0 0

S 0

0 0

0 0

0 0

SSI.J 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW 0

0 0

0 0

0 0

NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

I 0

0 0

0 0

0 0

i Total Periods of caln(hours):

0 Hours of missing datai 0

i 1

6

Table 4A BATCH RELEASE MODE QUARTER #4 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD: 10 80 ) 12-31-80 i

STABILITY CLASS: G ELEVATION 10.On Wind Speed (mph) at 10.On level Wind Direction 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

0 0

0 0

0 NNE O

O O

O O

O O

NE O

O O

O O

O O

l ENE O

O 0

0 0

0 0

i E

O O

O O

O 0

0 i

ESE O

O O

O O

O O

SE O

O 0

0 0

0 0

l SSE O

O O

O O

O O

S 0

0 0

0 0

0 0

SSW 0

0 0

0 0

0 0

SW 0

0 0

0 0

0 0

WSW 0

0 0

0 0

0 0

W 0

0 0

0 0

0 0

WNW C

0 0

0 0

0 0

NW D

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O 0

0 0

0 0

0 0

0 0

0 i

Total Periods of caln(hours):

0 Hours of missing datas 0

L i

I f

4..

l h

f I

1 i

1 j

TAtlLE 48 i

CLASSIFICATION OF ATN05PHERIC STABILITY Stab +lity Pasquilt od Ter: peratwee change 8

Classification Categories idegrees) with height t*C/100ml Er.tremely unst:ble A

25.0

<-1.9 Modcr:tely unst:ble.

B 20.0 1.9 to l.7 Slightly unst:ble C

15.0

.I.7 to l.5 Neuttal D

10.0

.l.5 to 0.5 Sli hily stable E

5.0 0.5 to 1.5 t

Moder:tely stable F

2.5 1.5 to 4.0 E.stremely st:ble C

1.7

>4 0 2

2 Standstd devistion of hori:ent:1 wind direction fluctuation over a period of 15 minutes to I hour.The values shows: are avers; for cach st:bility c!sssif.:: tion.

I 4

s r

a

.,v r,

TASI.I 5 ItAU!OACTIVE I.! QUID SA'.1P!.!NG AND ANAL SIS f.iq uirl Sampling Type of Dc!cetable Sourcel Frequency Activity Analysis Concentrations fu Ci/mlia A.

Waste 31onitor Each Datch Principal Gamma Emitters 5 x 10-7D Tank Reicases One Batch /51onth Dissolved Gases 10-5 Weekly Composite

  • Ba-La-140. 1-131 10-6 l

70-5 H-1

.'.lonthly Composite Gross Alnha 10-7 c

Gross Beta 5 x 10-7 Quarterly Composite gr-89,Sr-90 5 x 10-8 C

D.

Steam Generntor Weekly Composite Princinal Gam'ma Emitters 5 x 10-7 d

Dlowdown B a-La-140. 1-131 10 0 One sample / month Dissolved Gases 10-5 Slonthly Composite H-3 1

10-5 Gross alohn I

10-7 Gross Beta 5 x 10 '

Quarterly Composite Sr-89. Sr-90 5 x 10-8 b

C. Turbine Building Each Batch Principal Gamma Emitters 5 x 10-7 d

Sump 3The detectability limits for activity analysis are based on the technical feasibility and on the potential significance in the environment of the quantities released. For some nuclides, lower detection limits may be readily achievable, and when nuclides are measured below the stated limits, they should also be reported.

bFor certain mixtures of gamma emitters. It may not be possible to measure radionuclides in con-centrations near their sensitivity limits when other nuclides are present in the ample in much greater concentrations. Under these circumstances, it will be more appropriate to calculate the concentrations of such radionuclides using measured ratios with those radionuclides which are routinely identified and measured.

CA composite sampic is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged.

dSampled and analyzed only in the event of primary to secondary leakage and then only if to be discharged to the environs.

!f the required sensitivity (10-6) can be obtained with the gamma scan on each batch, the weekly C

composite will not be required.

I A batch release is the discharge of liquid waste of a discrete volume,. A centinuous release is the discharge of liquid waste of a nondiscrete volume: a nondiscrete volume has an uninterrupted discharge flow during the continuous release.

TABLE 6 RADICACTIVC CASEGUS WASTE SAMPLING AND ANALYSIS Gascous Sampling Types of Detectahic Sourecc Frequency Activity Analysis Concententions 1

(u Ci/ml)"

A.

Waste Gas Decay Tank to be released Principal Gamma Emitters 10-4 Tank Rc! cases H-3 10-6 B. Containment Each Purgcc or Weekly Principal Gamma Emitters 10'4 Purge Releases for Continuous Purge H-3 10-6 C.

Condenser Sicam Monthly Principal Gamma EmittersD 10-4 Jet Air E]cetor (Gas Samples)C H-3 10-6 D.

Environmental Monthly Principal Gamma Emittersb 10-4 Release Points (Gas Samples)C (Plant Vent Stack)

H-3 10-6 Weekly (Charcoal I-131 10-12 Samole)d I-133 10-10 Weekly Principal Gamma Emitters (Particulates)d (Ba-La-140, I-131 and 10'11 others)

Monthly Composite (Particulates)

Gross alpha 10'11 e

f Quarterly Composite (Particulntes)

Sr-89. Sr-90 10-11 i

i 3The above dctcctability limits for activity analysis are based on technical feasibility and on the potential significance in the environment of the quantitics released. For some nuclides.

lower detection limits may be readily achievoble. and when nuclides are measured below the stated limits, they should also be reported.

b For certain mixtures of gamma emitters, it may not be possible to measure radionuclides at levels near their sensitivity limits when other nuclides are present in the sample at much 4

higher levels. Under these circumstances, it will be more appropriate to calculate the levels of such radionuclides using measured ratios with those radionuclides which are i

inessurabic.

C Analyscs shall also be performed fol'owing cach refueling, startup, or similar operational occurence which could alter the mixture of radionuclides, d

Analyses.shall also be performed daily for a week fcilowing cach refueling, startup or 3

sirrilar operational occurrence which could Icad to significant increase or decrease in radiciodine releases.

C A batch release is the discharge of gaseous waste of a discrete volum'e. A continuous release is the discharge of gaseous waste of a nondiscrete volume:

interrupted discharge flow du ring the continuous release. a nondiscrete volume has an un-

j TABLE 7 LIQUID DISCl!ARCES NOT MEETING ETS SPECIFIED ANALYSIS DETECTION LIMITS Total Isotope Count Volume Dilution Isotopic LLD for

% of Total

% of Time Discharged Water Activity (1) of Analysis Isotopic Total Batch #

Date Sec.

Gallons Callons (CL)

Interest (pC1/ml)

Activity Dose 305 10/31/80 20,000 3,100 1.45 E 06 1.11 E-03 Ce-144 5.6 E-07 1.7 E 00(2) 2.7 E-02 Np-239 7.0 E-07 2.1 E 00 4.8 E-02 Ru-106 8.6 E-07 2.6 E 00 4.5 E-01 Mo-99 7.6 E-07 2.3 E 00 2.2 E-02 I-132 1.4 E-06 4.2 E 00 6.1 E-04 Sr-91 6.2 E-07 1.9 E 00 1.6 E-01 (1)

Doco not include Tritium (2) Did not meet < 1.0% isotopic criteria.

Computed using the most conservative (highest) dose received for Whole Body or organ.

-.,