05000317/LER-1980-060-03, /03L-0:on 801018,surveillance Testing Found RC-200 & RC-201 Lift Setpoints to Be 70 Psi & 56 Psi,Respectively, Above Max Tech Spec.Cause Not Stated.Setpoints Adjusted

From kanterella
(Redirected from ML20002A781)
Jump to navigation Jump to search
/03L-0:on 801018,surveillance Testing Found RC-200 & RC-201 Lift Setpoints to Be 70 Psi & 56 Psi,Respectively, Above Max Tech Spec.Cause Not Stated.Setpoints Adjusted
ML20002A781
Person / Time
Site: Calvert Cliffs 
Issue date: 11/17/1980
From: Miernicki M, Wenderlich R
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20002A780 List:
References
LER-80-060-03L, LER-80-60-3L, NUDOCS 8011210534
Download: ML20002A781 (2)


LER-1980-060, /03L-0:on 801018,surveillance Testing Found RC-200 & RC-201 Lift Setpoints to Be 70 Psi & 56 Psi,Respectively, Above Max Tech Spec.Cause Not Stated.Setpoints Adjusted
Event date:
Report date:
3171980060R03 - NRC Website

text

"

LICENSEE EVENT REPORT e

O CONTROL BLOCK: l l-l l

l l

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATl!NI U

i 8

lo lil l M l D l C l C l N l 1 l@l 0 l 0 l - } 0 l 0 l 0 l 0 l 0 l-l 0 l 0 l@26l 4 l1 l 1 l 1 l 1 l@

l lg 7

8 9 LICENSEE CocE 14 15 ucENsE NuM8ER 25 license TvPE Jo 57 CAT 68 CON'T lol'l E"RU l ll@l 0 l 5 l 0 } 0 l 0 l 3 l 1 l 7 }@j l l 0 l 1 l 8 l 8 l 0 }@l1 l 1 l 1 l 7 l 8 l 0 l@

7 8

60 81 coCKET NUM8ER 68 63 EVENT oATE 74 75 REPORT oATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h While in Mode 3 during surveillance testing, at 1645, found RC-200 lift I

io iai l setpoint to be 70 PSI above the maximum (T.S. 3.4.3). - The setpoint was l

g o,3, l gl adjusted to 2494 PSIG at 1720 on 10/18/80. While in Mode 4 during sur-l F5Ti1 I veillance testing, 'at 2330 on 10/18/80, found RC-201 lift setpoint to be 56 PSI above the maximum (T.S. 3.4.2).

The setpoint was adjusted to l

ro rg-l i lo ; 21 l 2552 PSIG at 0400 on 10/19/80. Both PORV's remained operable during l

these events. This is not a repetitive event.

l

,og,,

sf8%"SE sen'oE

  • EI:'E
  • ^M s58f#E couroNENT coof

^

c Loj.SJ I cl B l@ LEj@ l B l@ IV lA ll IV [E lX l@ l Xl@ [Bj @

7 8

9 10 at 12 10 18 19 20 LE R/Ro EVENTvEAR REPORT o coE N,

@,Rg l218 l0 l l_l l0 l6 l0 l y

l 0l 3l lLl l-l O

22 23 24

6 27 28 29 30 31 32 AK N A o

oNP NT M T WoVRs 22 s8 i FoR 8.

sVP9L E MA USACTURER l E lgl34Z lg l3SZ lg l36Zl@l0 l0l0 [0'l lY lg lY lg l43N l g l0 l2 l4 l3 l g 33 37 40 41 42 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h [T1T1 i Set pressures on both valves had previously been set at manufacturer's 1

i,i,ii facility following refurbishment. Valves were tested inplace in ambient i

operating environment using hydroset method. This resulted in a more i

,,,,,i gi accurate adjustment of the lift pressures.

l I

it iAi i oTNER sTAius @5'sc"o Nv' oiscovERv oEsCRipTioN @

TM spowER C

li 15 I (_frj @ l 0 l 0 l 0 l @ l NA l

[3_J@l Surveillance Test l

Co'0TEyT 7

' AcriviTy f.ELEAsto oF RELE ASE AMOUNT oF ACTIVITY LCrCATioN oF RELEASE I1 I s I [Z ] @ [,IJ@l NA

'l l

NA l

' etRsoNNd ExposMEs oEscRierioN@

NuMQER rvre l

L'_ll.J 10 10 10 l@l -Z l@l NA

  • ERsoNNE't iN;uZ Es oEsCRiefioN@

NuM8ER

}

101010l@l NA 1 a oss oF oR o AG O FACillTY l

I i l 9 l (Z_j@l NA 80 7

8 9.

10 [2].o_j @,,,,J@of CRIPTioN l

NA l

llll1IIIIIIIl5 is5UE 68 69 80 E 7

8 9 10 R.L. Wenderlich/M.J. Hiernicki pgang (301) 269-4776/4860 2,

NAMC OF PREPARER

- - - "i 8 01121 o 5 M

e LER NO.

80 DOCKET NO.

50-317 LICENSE NO. DPR-53 EVENT DATE 10-18-80 REPORT DATE 11-17-80' ATTACHMENT EVENT DESCRIPTION AND PR08ABLE CONSEQUENCES CONTINUE 0 While in Mode 3 during performance of STP-M-2-1, at 1645 found RC-200 lift setpoint to be 2580 PSIG, 70 PSI above the maximum lift setpoint.

This was a degradation of the requirements of T.S. 3.4.3.

The setpoint of RC-200 was adjusted to 2494 PSIG at 1720 on 10/18/80. While in Mode 4 during performance of STP-M-2-1, at 2330 on 10/18/80, found RC-201 lift setpoint to be 2631 PSIG, 56 PSI above the maximum lift setpoint.

This was a degradation of T.S. 3.4.2.

The setpoint of RC-201 was ad-justed to 2552 PSIG at 0400 on 10/19/80. The redundant RC-200 remained operable during this event. Both PORV's remained operable during these events. These events had no impact on public health or safety, and are non-repeti tive.

=