05000296/LER-1980-038-03, /03L-0:on 800907,during Surveillance Testing,Msiv 3-FCV-1-26 Closed Too Fast.Caused by Low Oil Level in Hydraulic Cylinder.One Gallon of Oil Added & Flow Control Valve Adjusted to Obtain Correct Valve Speed

From kanterella
(Redirected from ML19351D637)
Jump to navigation Jump to search
/03L-0:on 800907,during Surveillance Testing,Msiv 3-FCV-1-26 Closed Too Fast.Caused by Low Oil Level in Hydraulic Cylinder.One Gallon of Oil Added & Flow Control Valve Adjusted to Obtain Correct Valve Speed
ML19351D637
Person / Time
Site: Browns Ferry 
Issue date: 10/06/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19351D636 List:
References
LER-80-038-03L-03, LER-80-38-3L-3, NUDOCS 8010140390
Download: ML19351D637 (2)


LER-1980-038, /03L-0:on 800907,during Surveillance Testing,Msiv 3-FCV-1-26 Closed Too Fast.Caused by Low Oil Level in Hydraulic Cylinder.One Gallon of Oil Added & Flow Control Valve Adjusted to Obtain Correct Valve Speed
Event date:
Report date:
2961980038R03 - NRC Website

text

... <

Nna N is.,

..... ~.. _.

47 77)

LICENSEE EVENT REPORT ct,Nrnoi nLocc l l

l l

l l

l@

iPLEasE PAINT OR TYPE ALL AEQUIRED INFOR64ATION4 i Al L I B l R l Fl 3 l@l 0 l 0 l ~ 10 l0 l 0 l 0 l0 l-lo l0 l@l 4l 1l Il 1l 1l@l l

l@

i s

8 L'CEN5E E Cygg se it LICENSE NuMWER 29 d6 LICENSE Tv78 JO

$7 C A T 54 ccNT

$,* "c' l L l@l 0 l 5 l 0 l 0 l 0 l 2 l 916 l@l 0 l 910 l7 l 8 l 0 )@l11010161810 l@

loItI 7

4 60 61 DOCK ET NuMc Esq the 69 tytNT DATE 74 7%

ptPORTDATt 83 LVENT DESCHsPTION AND PROS A8LE CONSEcutNCES h t o 121 LWith unit at 99 percent steady state power, main steam isolation valve 3-FCV-1-26 l

g j closed too fast while running Surveillance Instruction 4.7.D.1.b.2.

The re was n,.,

l

("T3 j. ; [ danger to the health or safety of the public. The valve was closed and power l

t jo!3) ;was reduced for 144 hours0.00167 days <br />0.04 hours <br />2.380952e-4 weeks <br />5.4792e-5 months <br /> as a result.

"A",

"C",

and "D" main steam lines were l

joj,,j joperable. See Technical Specification 3.7.D.1.

Previous similar occurrences were j

f7T71 1 reported on LER BFRO-50-296/78014.

l 1

I o is 11 I

SYSTEM C AUSE

CAUSE

COMP v ALg g CCDE CooE sveCood COMPONENT CODE SLSCCDE susC006 fo"Til I CI ol@ W@ W@ l vl Al Ll Vl Ol Plh Wh W h i

s 9

10 is et IJ is td 20 Sf 0LE NTI AL OCCuHaENCL REPORT af vision

,,,,EVENTvtAR af PORI No.

COCE fvPt NO

@ ;lg n mi 18 10 I l--J l 01 31 81 Ld 1013I It I L,, J LO_J g,a;

_i, a

n 24 n

v n

n n

YA< M 'AW,'y o'N !<Si7

'TMF

- oos @ 's'J.*S,"*is'

,oT"L'.

'"s'u",'P5is' u!E"IfA'u'R, lxIglzl@

l a l@

[z j@

l 01 1l 4! 41 L.YJ@

L7.J@

LLJ@

lAlsisisit 14 Jh 36 J) 4Q 4%

4)

()

44 (f

cAusE DESCRIPTION AND CCARECilVE ACTIONS h lilollThe oil level in the hydraulic cylinder was low.

No leakace was found. One l

L'._LJ l gallon of oil was added and the flow control valve adiusted to obtain correct I

( ; T--} l speed settina. No future corrective action is needed due to low occurrence rate.

I g l Atwood and Morrell. 26 inch C.S., Wye pattern. 1250 lb.

l li l 41 l i

e e i ao

% POWE84 OTHtR$fATUS

$0 m DiSCOV ERV CESCRepfloN 51 y W @ l 0l 9l 9l @l NA l

lBl@l SI 4.7.D.1.b.2 l

Ahtvtiv CO ftNT RE LE A$f D Op a.g gg Alf AMOUNT Ol' A,.Ts' s f y LOCAflON OF RELg Asg I i i s I Lz 1 @ Lz_l@l N^

l I

N^

l J

e 9 10 11 A4 46 80 P( RtONNE L F 8 POSbH E1 No. 'M9 f R TYPf Of LCRIPTION I O I o I o l@LZJ@l I

i >

Pi..co.d' N,u'ics e [ lD

_l n otsCR,PnoN@

D c

9-}\\_f i

D

.uv..R l0l0l0l@[

T1 l

NA.

i

\\

i -

i

~ ~

~ '

""'d i

e 1 ti 12 so e O3 op pig riusAct TO FACit ifv Q t,PC nt.bMIPisON v

Whl Pot cr reduced to 75% for 144 hrs.

and unit outace of 48 hrs.

l 1

9 d

'I 3

IJ SO Om

..,w g a r;reiPTioN 1,f,,,Jo]L;i[81=aa-I IIIIIIi!l!III.'

i n

)

in u n U 19 f) 68 49 so ;

r "J AW OF Ps1EP AHt.H

  1. 640NE

g 9. -er Tennessee Valley Authority Form BF-17 Browns Ferry Nucicar Plant BF 15.2 1/10/79 LER SUPPLEMENTAL INFORMATION BFRO-50 296 / 8G38 Technical Specification Involved 3.7.D.1 Re' ported Under Technical Specification

6. 7. 2. b (2)

Date of Occurrence 9/7/80 3:30a.m.

3 Time of Occurrence Unit Identification and Description ^of Occurrence:

While running SI 4.7.D.lb.2 with unit at 99% steady state power, main steam isolation valve FCV 3-1-26 clor d too f ast.

Conditions ' Prior to Occurrence:

Unit 1 - 96% steady state power.

Unit 2 - scheduled refueling outage Unit 3 - 99% steady state power Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment. Describe.

A, C, and D main steam lines were operable Apparent Cause of Occurrence:

i The oil level was low in the liydraulic cylinder. No leaks were detected..

Analysis of Occurrence:

l There was no danger to the health or safety of the public, no damage to plant or equipment and no release of activity. There vas a power reduction to 75%

for 144 hours0.00167 days <br />0.04 hours <br />2.380952e-4 weeks <br />5.4792e-5 months <br />, and a unit outage for approximately 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

i

Corrective Action

Valve was closed until one gallon of oil was added to cylinder and valve was tested satisf actorily.

FaGure Data:

LER BFRO-50-296/78014, 296/78013, 259/74002, 259/74012, 259/74038.

  • Retention :

eriod - Lifetime; Responsibility - Administrative Supervisor

  • Revision:

/

QU m