05000317/LER-1980-055-03, /03L-0:on 801001,during Normal Operation Containment Atmosphere Particulate RMS Detector Failed.On 801008,channel Failed Again.Caused by Water Inside Sampler Wetting Detector & Connector & Broken Signal Lead

From kanterella
(Redirected from ML19339B618)
Jump to navigation Jump to search
/03L-0:on 801001,during Normal Operation Containment Atmosphere Particulate RMS Detector Failed.On 801008,channel Failed Again.Caused by Water Inside Sampler Wetting Detector & Connector & Broken Signal Lead
ML19339B618
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 10/31/1980
From: Rizzo P, Wenderlich R
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19339B615 List:
References
LER-80-055-03L, LER-80-55-3L, NUDOCS 8011070336
Download: ML19339B618 (2)


LER-1980-055, /03L-0:on 801001,during Normal Operation Containment Atmosphere Particulate RMS Detector Failed.On 801008,channel Failed Again.Caused by Water Inside Sampler Wetting Detector & Connector & Broken Signal Lead
Event date:
Report date:
3171980055R03 - NRC Website

text

__ __

a.m CONTROL SLOCK: l l

l l

l l.

I l.E I T C3 TYPE ALL REQUlIED INPOOMATioN)

IM 10 l C I c IN 11 l@l010 l-1010101010 l-1010 @l411111111

@l l

l@

o i 7

8 9 uct SEE Coot le ts ucE~stNuMcEm 21 '

2e ucENst TYPE 40 57 CAT 58 COvT E

Eu% l L l@l0 l 5 l0 l010 l311 17 l@l1 1010 Il 1810 l@l1 l01311 IS 10 l@

7 8

80 48 oOCKET NuMSER et 89 EVENT oATg 74 75 R EPoRT oATE 80 EVENT DESCRIPTION ANo PRO 8ASLE CONSEQUENCES h fB TT1 l Durino normal oower ranae coeration. at 0815. the Ctat atmosohere I

o I

particulate RMS detector failed.

It was restored to service at 1700 1

17171 I on 10/3/80. On 10/8/80. at 1700. the channel failed aaain and was l

l"BTirl I returned to service at 1705 on 10/9/80. The redundant Ctmt caseous I

i TTTTI I activity monitor and Ctmt sumo level alaru system remained ooerable.

I i

[TTTl i Therefore, the events had no impact upon the oublic health or safety.

I LER 79-21 (U-2) describes a similar event.

I i o is i susi"o'o'E si5N"oEE i

YoTE SE su'#EE coMao~E~r coot

' lTTTl lB lB l@ y@ y@ l Il N I S I T l R l U l@ lE l@ lZ l@

" as"T[

ccid"c'

'r;?"'

i nE~r v[..

~.

l

@,ag,,,o 1810l L_._j l 0 l 5l 51 Lt.1 10131 lL I l-1 LO_1 u

2i 22 23 24 26 27 28 29 29 31 22 N

P r

METH hours 22 s8 i Po 8.

u

  • MA F Rest (Ajg)24 lg l2sI lg gg li 0l0l0l l

[YJg iNl@

lAl@

M l1l2l0l@

22 2.

s 40 ai,

2 u

a

.7 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 iiioil In both failures, water was found inside the sampler wetting the detec-I ri s i i l tor and its connector. A broken signal lead at the detector was also I

gI found after the 10/1/80 a yt. The water aoparently condensed from the I

gi sample. Insnediate action included replacement of the detector (both I

mI events), cleaning and drying the connector and sample volume.

I erwansvarus @

"'sEo i#v' oiscovEnv oEsenimo @

)

'sTOT s,owEn C

i

((_j @ l 0l 91 0l @ l NA l

(_A,j@l anerator Ohtervatinn l

is i2 n

so s g g,,,

7 4Mou~ro,4criviry @ l tocario~e,atuut@

cEuesto@o, aEaufllj@l NA l

NA l

[1 ]

i s

' ' reso~~'Et o,osets oEscai,rio~ @

~uM.o rv,E Li L.J 101010 l@LIJ@l NA l

,Easo ~Et imuns oEsc-o~@

~uM.E.

lalo 10l@l NA l

i a

" g

,Aciury g ogo, on o a

[1.,j@l NA i

1 9 7

8 9 to 80 E CRIPvtoN issuto@l (1,j NA l

i Ill1111IlIlII 2 o 68 69 80 1 7

8 9 10 (M1) MQ 4776/4786 2,

R.L. Wenderlich/P.G. Riv7n pyoug NAME oP PREPARER 801107033(o

. m s

LER NO.

80-55 DOCKET NO.

50-317 EVENT DATE 10/01/80 REPORT DATE 10/31/80 ATTACHMENT

@SEDESCRIPTIONANDCORRECTIVEACTIONSCONT'D The source of humidity in the sampler lines has not been detemined.

No known leaks in containment were in the vicinity of the sample point. On 10/18/80 after shutdown for refueling, a general inspec-tion for leaks within containment performed by plant operators re-vealed no adjacent leaks.

It is assumed, however, that the general humidity level in containment was elevated by identified leaks in several remote locations. These leaks are being repaired during the current outage. The sampler has continued to function without failure since 10/10/80.