05000333/LER-1980-069-03, /03L-0:on 800807,during Normal Shutdown,While Conducting Surveillance Test F-ST-22A,auto Depressurization Sys Timer Found Set Below Limit.Caused by Setpoint Drift. Timer Adjusted & Returned to Svc

From kanterella
(Redirected from ML19331D417)
Jump to navigation Jump to search
/03L-0:on 800807,during Normal Shutdown,While Conducting Surveillance Test F-ST-22A,auto Depressurization Sys Timer Found Set Below Limit.Caused by Setpoint Drift. Timer Adjusted & Returned to Svc
ML19331D417
Person / Time
Site: FitzPatrick 
Issue date: 08/29/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19331D414 List:
References
LER-80-069-03L, LER-80-69-3L, NUDOCS 8009020422
Download: ML19331D417 (1)


LER-1980-069, /03L-0:on 800807,during Normal Shutdown,While Conducting Surveillance Test F-ST-22A,auto Depressurization Sys Timer Found Set Below Limit.Caused by Setpoint Drift. Timer Adjusted & Returned to Svc
Event date:
Report date:
3331980069R03 - NRC Website

text

RC F

..M 366 M. a. *N vb e.ke

.3 u v L,A e w n

....o....

(7 77) iiCENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

lo lil lN lY lJ l A lF l1 !@l0 l0 l-l0 l0 l0 l0 l -I OI 0l 0l@l hl 1l 1l 1l 1l@l l

l@

i 8 3 LICENSEE COOL 14 15 LICENSE NUMBER 25 26 LICENSE TYPE Jo 57 CATSd CON'T 10!11 3$g"c' l L l@l 015 lo lo 10 13 13 13 @l n I g l n l y I n I e l@l n I g I > l o f a l o l@

7 8

60 61 DOCKET NUMBER 63 69 EVENT DATE 74 75 REPORT DATE 80 EVENT OESCRIPTION AND PROB ABLE CONSEQUENCES h I

10121l During normal shutdown while conducting Survnillnnca Tn e F " ??A

  • he !nc ti-=
o l3l l was found set at 112 seconds when TS Table 3.2-2 required a setpoint of 115 to 125 l

cause n sicm 4 P enn e l 1 o l.i l l seconds. Operation of the timer 3.,

( seconds early would not l o 151 l change in Che operation of the system.

The system was not reauired to be ocarnblo I

I l o is 1 1 with the reactor in the old condition.

l lo l 71 l 1

I o IU l CE CODE SU8C E COMPONENT CODE SUSC D'E SU E

10191 l S I F l@ lE l@ J@ l II N l S l T l R I U l@ W@ Lzl @

7 8

9 to 11 12 13 18 19 20 SE QUENTI AL OCCURRENCE REPORT REVISION LER RO EVENT YEAR REPORT NO.

CODE TYPE N O.

h aE l 8I 0l l-l l O l 619 l d

10l3l l Ll l-l

(,,g_j

_2n 22 23 24 26 27 23 29 30 31 32 T K *= AC O ON PLANT ME HOURS 22 S8 iTT D FOR b 8.

SUF PLIER MAN FACTURER I E l@l Z l@

l Z l@

l Z l@

l 0 l 010 l 0 l W@

lYl@

lNl@

lGl0l8l0l@

33 34 S

36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS j i l o l l The improper set point is attributed to drif t.

The timer was adjusted nna -nan l

l i l i 1 l fully operable on the following day.

No additional action fa rocuiraA I

l J

li121l_

I liiall I

I i 14 I I 30 7

8 9 ST S

% POWER OTHER STATUS CIS O RY DISCOVERY DESCRIPTION NA l

W h ! Survo m nnc~

l IiIsI(c_]@ l01010l@l

'2 n

u

.s 4

80 A!TIV,TY CORTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE I

l I

Ii Ie I Ltl @ LzJ@l m

na 7

8 9 10 11 44 45 00 PERSONNEL E XPOSURES NUMBER TYPE CESCRIPTION l

1iTTl I O I O l 0 l@LZJ@l NA PERSONN EL iN;uViES oESCRiPTiON@

NUMBER l

li la l 1010101@l NA 80 7

8 9 11 12 LOSS OF OR DAMAGE TO FACILITY TYPE OESCRIPTION l

L' 19.1 l ZJ@l NA 80 1

8 9 10 PUBLICITY NRC USE ONLY IS$uf D

DESCRIPTION

NA l

l l l l I I l l l l l 1 1 },

j 121o1LN_jhl 68 69 80 C 7

g g 8 009 0 2 0 T, hap pggp,ggg 315-342-3840 j

W. Verne ChiIds pgang; u