%,Y s'

EDISON GdNN J. SWPSON vice President. Power January h, 1973 Mr. Frank E. Kruesi Director of Regulatory Operations U.S. Atomic Energy Commission Washingt.on, D.C.

205h5 Docket No. 50-3h6

Dear Mr. Kruesi:

You are hereby notified of a situation which could be considered re-portable in accordance with 10 CFR Part 50.55(e)(1)(1), " Conditions of Construction Per=its".

This situation relates to the veld records for the Davis-Besse Nuclear Power Station steam generators.

(N A recent audit of veld records conducted by Babcock & Wilcox's (nuclear

('s) steam supply system supplier, B & W) QC organization at their Barberton Works has shown that filler wire qualification test reports are incom-plete for several heats of weld filler materials used in steam generator fabrication. B & W is currently reviewing records to define the extent of the incomplete documentation.

We vill submit a written report on the documentation situation within 30 days.

Yours very truly, a > > 5:s W

.,/ -

,,_.7,,,

/

GJS:cd cc Mr. Boyce H. Grier, Regional Director Region III J

8002030 d 2 1764 THE TOLEDO EDISON COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO. OHIO 43652 1

~