Reviews 730119 Grinnel Rept Re Improper Tack Welds for Facility Piping.Suggests Comprehensive Vendor Insp of Grinnel Shops
ML19326A343
Person / Time
Site: Davis Besse 
Issue date: 03/08/1973
From: Potapovs U
US ATOMIC ENERGY COMMISSION (AEC)
To: Henderson J
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19326A340 List:
References
NUDOCS 8002030160
Download: ML19326A343 (2)


Text

. O

~

Mne.ft'

  1. 4%

UNITED STATES b

ATOMIC ENERGY COMMISSION

- (-

l * 'M* D

J. B. Henderson, Chief, Reactor Construction Branch, RO THRU:

G. W Reihmuth, Chief, Technical Assistance Branch, RO

, b)l. )S$

GRINNELL REPORT ON IMPROPERLY MADE TACK WELDS FOR DAVIS-BESSE PIPING (Dated January 19, 1973)

The Grinnell report suggests that qualification requirements for tack welders are not clearly defined and that untested fitters have performed tack welding in many pipe fabrication shops and on many field erection sites. (pages 2, 3, 4 and 5 of the report)

It must be noted that the use of unqualified weldors for tack welding is a clear-cut violation of all nuclear construction codes.Specifically; Paragraph 1-727.4.2(b) of USAS B 31.7-1969 - Nuclear Power Piping states: "All tack welds shall be made by a qualified weldor."

Paragraph 127.4.2 (b) of USAS B 31.1.0-1967 - Power Piping states:

, []j

" Tack welds shall be made by qualified weldors. Tack welds made by

\\

an unqualified weldor shall be removed."

Paragraph NB-4321(b) of ASME Section III (1971) states: " Procedures, welders and welding operators used to join permanent or temporary attachments to pressure parts and to make permanent or temporary tack welds used in such welding shall also meet the qualification requirements of this article."

While the nondestructive testing review of the affected weld joints and post-welding qualification of the fitters provides reasonable assurance that the overall quality of these joints has not been compromised, the apparent unfamiliarity of the ITT-GrinnellCorporation with nuclear construction requirements raises a more general concern regarding the fabrication operations at that facility.

Similarly, the Grinnell report suggests (page 8) that,since the ASME code permits weldor qualification by radiography in lieu of mechanical testing of the weldment, each of the unqualified fitters could be automatically qualified by a single radiographic exposure of a weld joint for whidthe performed the tack weld. This rationale is also inconsistent with conventional interpretation of the ASME code (Ov) 8 0 02 0 3 0 \\bo Y

~

MR d 3 73 J. B. Henderson s' requirements since the code maices no provisions for qualifying more than one weldor per single test joint.

~

Because of the above examples of questionable code interpretations, it may be advisable to conduct a comprehensive vendor inspection of the Grinnell shops.

r

,ha h *('

Ltf o%

'gL;f(M i

Uldis Potapovs Senior Metallurgical Engineer i