05000321/LER-1980-078-03, /03L-0:on 800630 & 0701,during Hot Standby Operation,Primary Containment Oxygen Concentration Exceeded Limit.Caused by Reactor Bldg to Torus Vacuum Breaker Valve Opening & Oxygen Analyzers Not Calibr.Monitoring Increased

From kanterella
(Redirected from ML19320D544)
Jump to navigation Jump to search
/03L-0:on 800630 & 0701,during Hot Standby Operation,Primary Containment Oxygen Concentration Exceeded Limit.Caused by Reactor Bldg to Torus Vacuum Breaker Valve Opening & Oxygen Analyzers Not Calibr.Monitoring Increased
ML19320D544
Person / Time
Site: Hatch 
Issue date: 07/15/1980
From: Baxley S
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19320D539 List:
References
LER-80-078-03L-01, LER-80-78-3L-1, NUDOCS 8007210492
Download: ML19320D544 (2)


LER-1980-078, /03L-0:on 800630 & 0701,during Hot Standby Operation,Primary Containment Oxygen Concentration Exceeded Limit.Caused by Reactor Bldg to Torus Vacuum Breaker Valve Opening & Oxygen Analyzers Not Calibr.Monitoring Increased
Event date:
Report date:
3211980078R03 - NRC Website

text

W.Lk (ZLCcLY11J WL4MW3VGEN N RC FORM 366 r,17)

LICENSEE EVENT REPORT oNTHol block:

l l

l l

l l

(PLEASE PHINT cR TYPE ALL FIEQUlHED INFORMATION) bM l G' A l El II Hl1 l@l0 l o l -l 0 l Ol 0 l Ol 0 l 10 l Ol@! 4 l1 l lli l 11@l l

l@

8 V LICENSEE CODE 14 lb LtCLNSE NVMI5EH 25 20 LICENSE 1YPE Jo 6 7 C A I 68 6

oN'T W

"Z Z Lt_J@l01 51 0101 0131 211 l@l n I si, ! nl a I nl@l 017 I ll s I nIn l@

8 60 G1 DOCKET NUMBE R 68 69 EVENT DATE 74 7b REPOlil OATE t10 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h

' i2l l During Hot Standby Operation, primary containment oxvoen concentration I

o i3i iexceeded the allowable Tech. Specs. limit 3.7.A.5 of less than 4% on 1

O i4 i l6-30-80 for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and on 7-1-80 for 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />.

There were no effects i

O isi i to public health and safety due to this event.

This is a renetitive I

o ic i l occurrence and was last reported on LER #50-321/1980-044, 1

l ALU l l

0181 l 80 C OE CODE St BCO E COMPONENT CODE SUB DE SU E

i s l E l@ bj@ (J__j @ 17 l Z l 717 l Zl Z i@ LZ_l@ L1.J @

0191 l

8 9

10 11 12 13 18 19 20 SEQUEN TI AL OCCURRENCE REPORT REVISION

,, EVENT YEAR REPORT NO.

CODE TYPE N O.

@ sgg/RO I 810 I L-J l 017 I 81 l-l 10 13i LL_l 1-I Lo_]

LER a

_ 21 22 23 24 26 27 28 29 30 31 32 AKEN AT 04 LANT 1ET HOURS SB IT F ORh.1 8.

SUPPLI R MAN FACTURER I H l@l 2 l@ DJ@

LZJ@

101 01111 l L_vj@

la_J@

l 7 I@

17 l olo 191@

34 3b 36 3/

40 41 42 43 44 47 33 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h liiOi lThe cause of the event on 6-30-80 has been attributed to openina y a Rxl l Bldg. to Torus vacuum breaker valve when Torus spray was initiatt. ;o I

i i l cool the Torus air volume.

The event 7-1-80 was due to the oxvoen ana-i 2 l

llyzers being out of calibration.

Operators have been cautioned to moni-l

, 3 l tor T'orus pressure to prevent valve ooenina durina Torus soray operation 1 i 4 80 7

8 9 ST S

% POWER OTH E R ST ATUS IS RY DISCOVERY DESCRIPTION W@ l0 l 1l Ol@l Hot Standby l

lAl@l Operator Observation l

i s CO# TENT AMOUNT OF AC$sVIN @ }

LOCATION OF RELEASE @

ACTIVITY r. ELE ASED OF RELE ASE NA l

NA l

L2_] @ [Z_j @ SiEs l

i 6 PtRSONNtt rxPOS oESCHieTiON @

NuMoEn TvPE Li_L_] j a 10 l 0 l@t_z__j@l aA I

Pe nSONNE L iN;u%ES NuvuE R

DESCRIPTION

l010101@l NA l

i a 80 lt) 8 9 11 12 i

LOSS Of' OH DAMAGE TO FAttLITY TYPF DESCRIPilON W @l NA l

9 80 p) tl i 10 g

3S[sp(t @l ESCRIPTION NA l

llllllllllll1; 2 o a a so4 8'0 0 7 2 110 Y Q S.X.BaXley, Supt. Operations pgoyg91 N m m 1

{

NAME OF PitEPAHEH

d

NARRATIVE

REPORT Ga. Power Company Plant E. I. Hatch Baxley, Ga. 31513 REPORTABLE OCCURRENCE REPORT N0. 50-321/1980-078 On. June 30, 1980,while maintaining Hot Standby condition for HPCI testing, the 02 content of the primary containment ex-ceeded 4% when a Rx. Bldg. to suppression chamber vacuum breaker opened causing' air from the Rx. Bldg. to be drawn into the' suppression chamber.

Opening of the vacuum breaker was caused by temperature decrease of the suppression chamber air volume when Torus spray was placed in service to cool the suppression chamber air volume.

Operators initiated Np makeup and a controlled shutdown was begun.

The 02 content wds re-duced to less than 4% within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and the shutdown terminated.

On July 1, 1980, it was discovered that the oxygen concentra-tion-was over 4% when the analyzers were calibrated and returned to service.

The 0 content was found to be 4.5%.

N makeup wasinitiatedand$shutdownwasbegun.

7 The oxygen contentra-tion was returned to less.than 4% within 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> and the shut-down was terminated.

Operators have been cautioned to monitor suppression chamber pressure during Torus spray operation to prevent vacuum breaker operation.

i

}

t-