_.._. __
[
~
g Ll4-80(03-31')-9 v
U-0136 ILLINDIS POWER COMPANY ]g I E___
500 SOUTH 27TH STREET, DECATUR,ILlJNOIS 62525 j
r i
March. 31, 1980 I
r l
Mr. James G. Keppler i
Director, Region III l
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission 793 Roosevelt Road Glen Ellyn, Illinois 60137 i
Dear Mr. Keppler:
Clinton Power Station Unit 1 Docket No. 50-461 Construction Permit CPPR-137 1
)
On February 29, 1980, Illinois Power Company verbally notified Mr. Frank Jablonski, NRC Region III, of a potential reportable deficiency per 10CFR50.55(e).
We reported at that time that IP had
,-l learned of-a potential deficiency on Clinton Unit I when we were
,I advised that an error was found at Sargent & Lundy (S&L), the i
architect-engineer, which involved the use of an incorrect soil characteristic value as design. input to a computer model for developing building response spectra.
Illinois Power has continued to investigate the impact of.
this error.
Presently, not enough information is available to evaluate the impact or significance of this error, or the determi-nation of the reportability of the potential deficiency.
This letter confirms the verbal communication made today to Mr. H. Wescott, NRC Region III, and is intended to serve as an interim report on this potential deficiency.
We shall continue i
our investigation of this error and will keep you apprised of our determination as early as feasible.
t Sincerely, a
W L. J. Koch Vice President t
80073sog31!;