/04L-0:on 800530,during Normal Shutdown,Both Recorders for Gaseous Release Rate from Reactor Bldg Ventilation Sys & Plant Process Computer Were Out of Order During Same 16-h Period.Caused by Personnel Error
ML19318C445
Person / Time
Site: FitzPatrick 
Issue date: 06/27/1980
From:
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19318C442 List:
References
LER-80-054-04L, LER-80-54-4L, NUDOCS 8007010485
Download: ML19318C445 (2)


LER-1980-054, /04L-0:on 800530,during Normal Shutdown,Both Recorders for Gaseous Release Rate from Reactor Bldg Ventilation Sys & Plant Process Computer Were Out of Order During Same 16-h Period.Caused by Personnel Error
Event date:
Report date:
3331980054R04 - NRC Website

text

-

NRCFoawl3M U. S. NUCLEAR REGULATORY COMMISSION (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 6 jo jil lN lY lJ l A lF l 1 l@l 0 l0 l-10 l0 l 0 l 0 l -l 0 l O l O l@l 14 l 1 l I l 1 l 1 l@l l

l@

7 8 9 UCENSEE CCOE 14 15 UCENSE NUMBER 25 26 LICENSE TYPE 40 57 CAT 58 CON'T IoI1I Eu"RCE I L l@l0 l 5 lo l0 l0 l3 [3 13 l@l 0 l 5 l 3 l 0 l 8 l 0 l@l01( l2 l7 l8 l0 l@

8 60 61 OCCK ET NUMSER 68 69 EVENT OATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSECUENCES h ioi2; l During normal shutdown, personnel noted that for a sixteen (16) hour period that l

Io t al I part of the surveillance required by,.ETS 2.3.B.1.a was not met for the Reactor l

io,4; ; Building Ventilation Exhaust when the plant computer was out of service.

No l

t to ist i significant hazard existed.

See attachment for additional details.

lo is i 1 l

l0l7l [

l I

l o ia l l 80 7

$ 9 E

CCOE SUSC E COMPONENT CCCE SUSCODE SU E

jol91 l Z l Z l@ l Dl@ l Z l@ l Zl Zl Zl Zl Zl Zl@

l Z l@ l Zl@

7 3

9 to 11 12 13 18 19 20 SEQUENTIAL QCCURRENCE REPORT REVISION 1

EVENT YEAR REPORT NO.

CODE TYPE N C.

@ g.ER> AOl218l0l l-l 1015l4l l/l l0l4l l Ll l-l l0 l g

22 23 24 26 27 28 23 30 31 32 T K N AC C Q P NT MET HOURS S8 i PCR 8.

SUPPLIE MANUF RER lxigl24xl@

l Z i@

lZl@

l 0 l0 l0 l0 l lYl@

lNI@

lZj@

l Z l 9 l9 19 lj 33 JS 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h li j o l l The cause of the missed surveillance is attributed to personnel error.

Retrainina l

lili1 I and procedure changes should prevent recurrence.

No additional action is reauired.

I

)

i, ;7i l See attachment for details.

I 11 631 I I

til4 11 I

7 8 9 90 ST

% POWER OTHER STATUS 01 RY CiSCOVERY DESCRIPTION l_' I 5 I l G l @ l0 l0l0l@l NA l

l Al@l Operator Observation l

8 A!nviTY CsTENT AMOUNTOF ACUVITY @ l LOCATION OF RELEASE @

RetEASEO ePaELEASE Na 1

I li is I LIJ @ L2J@l a

7

$ 9 to 11 44 45 80 PERSONNEL EXPOSURES NUM8ER TYPE CESCRIPTION l t l 7 l l 0 l 0 l 0 l@l Z lhl NA l

l

,E ScN~EL iNJES CESCRi,Tio~ @

NuM8ER it lall0l0l0lhl NA l

7 5 9 11 12 80 LOSS OP CA DAMACE TO FACILITY Q TY8E CESCRIPT10N v

NA l

l i l 9 ] l Z l@l l

7 8 9 to 80 ISSU E CE CRIPTION 12 { o l l N fhl NA l

llllllllllIIly L

.F 3 9 IO 68 69 80 2

(

e POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT DOCKET NO. 50-333 ATTACHMENT TO LER 80- 054/04L-0 Page 1

of 1

During normal shutdown operations, part of the survelliance re-quired by Environmental Technical Specifications paragraph 2 3.B.1.a was not completed.

For a sixteen (16) hour period from approximately 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br /> 29 May 1980 until approximately 0800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> on 30 May 1980 both the recorders associated with the gaseous release rate from the Reactor Building Ventilation System and the plant Process Computer, which also records the same data, were out of service.

The recorder associated with the ventilation radiation monitor was placed out of service on 28 May 1980 for repair.

Following cleaning, lubrication and calibration it was returned to service at approximately 0800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> on 30 May 1980.

From approximately 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br /> on 29 May 1980 until approximately 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> on 30 May 1980, the plant process computer was out of service. As a result no data recording to determine the gaseous activity release rate on an hourly basis was available for approximately sixteen (16) hours. The ventilation radiation monitors and the associated alarm and trip units were operable, investigation of the event revealed that Operations Surveillance Test F-5T-40C titled " Computer Out of Service Surveillance" did not require initiation when the plant is shutdown. To prevent recurrence, F-ST-40C will be revised to clearly indicate that the surveillance must be initiated even if the plant is shutdown and the event will be included in the Licensed Operator Retraining Program.

No addtional action is required and the event did not cause a significant hazard to the public health and safety.