Ocon n 1 UNIT 3/7/73 DATE 50-269 DOCKET NO.

OPERATING STATUS 1.

REPORTING PERIOD:

Decemier 1, 1974 THROUGH December 31. 1974 HOURS IN REPORTING PERIOD:

744 2.

CURRENTLY AUTHORIZED POWER LEVEL (MWthe 2568 MAX. DEPENDABLE CAI ACITY (MWe. NET, A71 None 3.

LOWEST POWER LEVEL TO WHICH SPECIFICALL) RESTRICTED (lb ANY> tMWe. NET).

4 REASONS FOR RESTRICTION (IF ANYl:

THIS CUMULATIVE REPORTING Pl RIOD YR TO DATE TO DATE 0

5446.7 9800.5 5.

HOURS REACTOR WAS CRITICAL.

0 0

0 6.

REACTOR RESERVE SHUTDOWN HOLRS 0

5265.2 8254.3 7.

HOURS GENERATOR Oh OlNE.

0 0

0 8

UNIT RESERVE SHUTDOWN HOURS,

5 GRGSS THERMAL ENERGY 0

12226629 18237510 GENERATED (MWH) 10.

GROSS ELECTRICAL ENERGY 0

4230112 6318700 GENERATED (MWil) 11.

NET ELECTRICAL ENERGY GENER ATED

-4547 3993941 5953019 (MWH) 0 62.2 76.5 12.

REACTOR AVAILABILITY F ACTOR (1) 13.

UNIT AVAILABILITY F ACTOR (2) 60 I 64.4 O

0 52.4 53.3 14.

UNIT CAPACITY F ACTOR (3 p 100 10.1 9.7 15.

UNIT FORCED OUTAGE RATE (4).

16.

SHUTDOWNS SCilEDULED TO BEGIN IN NEXT 6 MONTHS (STATE TYPE.DATE. AND DUR ATION OF EACH):

17.

IF SHUT DOWN AT END OF REPORT PERIOD. ESTIMATED DATE Oi STARTCP.

18.

UNITS IN TEST STATLS (PRIOR TO COMMERCIAL OPERATION) Rt PORT Tile FOLLOWING:

DATE LAST DkTE FORECAST AClilEVED INITIAL CRITICALITY INITIAL ELECTRIC AL POWER GENER ATION COM MERCIAL OPL RATION (1)

REACTOR AVAILABILITY FACTOR =

X l00 0

(2)

UNIT AVAILABILITY F ACTOR

=

RS PORTING Pi. D NFT Elf ( TRIC \\L POwFR <;F NER ATFD (3)

UNITCAPACITY FACTOR p

=

FORCED OUTAGE liOURS (4)

UNIT FORCED OUTAGl: RATE HOURS GLNERATOR ON LINE + FORCFD OUTAGE HOURS i.8001130/7 @

/

D CKET NO.

50-269 UNIT SHUTDOWNS UNI l' NAMli Oconee Unit-1 I)ATl; 3/7/75 REPORT MONTil _ December,1974 TYPE METHOD OT F FORCED DURATION SHUTTING DOWN NO DATE S-SCtIEDULED (HOURS)

REASON (1)

THE REACTOR (2)

CORRECTIVE ACTIONS / COMMENTS 16 741019 S

552.0 C

1 17 741224 F

192 A

1 Reactor coolant pump neal repairs (1) REASON (2) METIIOD A -EQUIPMFNT I AILURF (EXPLAIN) 1-M ANilA L B-MAINT. OR TEST.

2-MANUAL C-RLl'ULLING SCRAM

}

D-REGULA10RY RESTRICilON 3-AUTOM ATIC L-OPFRA10R TRAINING AND SCRAM LICI NSE EXAMINATION F-A DMINIST R A1!VE G-OPER AllONAL ERROR (LXPLAIN)

II-OlllLR (EXPl.AIN)

SUMMARY

m

-.