05000321/LER-1980-025-03, /03L-0:on 800301,during Normal Operation,Reactor Core Isolation Cooling Pump Discharge Flow Switch Found Out of Spec.Caused by Instrument Drift.Barton Model 289A Flow Switch Recalibr

From kanterella
(Redirected from ML19309A897)
Jump to navigation Jump to search
/03L-0:on 800301,during Normal Operation,Reactor Core Isolation Cooling Pump Discharge Flow Switch Found Out of Spec.Caused by Instrument Drift.Barton Model 289A Flow Switch Recalibr
ML19309A897
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 03/25/1980
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19309A895 List:
References
LER-80-025-03L, LER-80-25-3L, NUDOCS 8004010477
Download: ML19309A897 (2)


LER-1980-025, /03L-0:on 800301,during Normal Operation,Reactor Core Isolation Cooling Pump Discharge Flow Switch Found Out of Spec.Caused by Instrument Drift.Barton Model 289A Flow Switch Recalibr
Event date:
Report date:
3211980025R03 - NRC Website

text

U.[k NU@LGMO [35NVlowWLdCl2JUL%@

I NIC FORM 366

!Um LICENSEE EVENT REPORT 4

Q CoNTnot stoCx: I, I

l l

l l

j@

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

Io Iil I G l A l E l I lH l 1 l@l 010 l0 l0 (0 l0 l0 l0 l0 l 0l 0l@l 4l 1l 11 1l 1l@l l

l@

7 8 9 LICENTEE CODE 14 15 LICENSE NUM6EH 25 26 LeCENSE T YPE J0

$7 CAT 38 7

8.

$[3RC"'lLl@]0l510l0l0l31211l@l0] 31 0l1 1810 l@l 01 31 21 51 8l Ol@

con'T 0 1 60 61 DVKET NUVBER bd 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND pro 8ABLE CONSEGUENCES h 10121l During normal operation while performing the RCIC System Flow Switch FT&C, I

flow switch 1E51-N002 was found at 75.5 GPM which is less than the Tech j

! l o l 31 i o 4 i

Spec Table 3.2-3, item 6 setpoint of >80 GPM.

This is a repetitive i

o s I occurrence and was last reported on LER No. 50-321/1977-05. There was

]

l o s I no effect upon public health or safety due to this event.

I Io I7I I I

[0 l8 l l 80 Su'nCIoE sdNEoE coo'e"

'#"$E S$C$5E COuPONENT COoE C0 g

l 11 B l@ W@ lE l@ l Il Nl Sl Tl RI Ul@ W@ [Zj @

7 8

9 to Ii 12 33 18 19 20 SEQUEN TI A L OCCUR R E NCE REPORT REVISION

_ EVENT YE AR REPORT NO.

CODE TYPE NO.

@gg l2 6 8l 0l

[__-j l 0l 2l 5l l/l l 0l 3l y

g l0]

LER RO 22 2J 24 26 27 28 29 JO 31 32 K N AC ON O PLA T YET HOURS 8 iT FOR B.

SUPPLIE MANU ACTURER LI_J@LH_J@

L_2J@

l zl O I 01 0! 01 01 Lyv_l@

W@

l_NJ@

l BI 018101@

33 34 34 36 3/

40 41 42 as 44 47 CAUSE DESCRIPTION AND CoARECTIVE ACTICNS lil0ll This event was caused by instrument drift.

The switch is a Barten, Type i

~

289A DP1S and was recalibrated, functionally tested and returned to I

li 121 1

, 7 I

service. Unit II utilizes the same type instrument.

l l

i a l i

l li 14 I I 80 7

8 9 ST s

asPOWER OTHE R STATUS IS O RY OISCOVERY DESCRIPTION l El@ l019 l7 l@l NA l

lB l@l Surveillance Test l

i s 8

'8 A!nviTY CO# RENT LOCATION OF RELEASE @

AVOUNT OF ACTIVITY @ l NA l

NA l

Rete Ast0 OF RUE ASE

@ l Zl@l l 6 PERSONNEL EXPOS ES oEsCR:PfiON@

10l0l0l@ W @l NA l

Nuvae n TYPE l

7 eERsONNE t iNau'R'i E s enCni,nON@

l l

NuuoER NA l l_i ta l 1010101@l 80 7

8 9 11 12 LOSS OF OR DAMAGE TO FACILITY NO NA 800@1n

'7 TYPE DESCRIPi80N l l t 191 (_Zj@l

~

80

[

7 8 9 10 oEsCRIP TION @

issudfL 81 NA l

lllllllllllIlj 2 o 68 69 80 T, 7

8 9 10 M-EM

{

R. T. Nix pgong NAME OF PREPARER

4

~..

s Y

i

NARRATIVE

REPORT Georgia Power Company

~

  • Plant E. I. Hatch Baxley, Georgia 31513 50-321/1980-025.

Reportable Occurrence Report No.

On March 1, 1980, during normal operation and wh The high setpoint flow switch,1E511N002, was found out of Tech Spec limits.

The Tech Spec was found at 8.0 in. of water which corresponds to 75.5 GPM.The surveillance y

limit is >80 GPM (8.96 in, of water), Table 3.2-3, iten 6.

i precedure limit is 9.5.1.2 in, of water (82 GPM).

It The instrument is a Barton Model 289A Differential i

This is The cause of this occurrence has been attrib'uted to instrument

~

a repetitive occurrence and was last reported on Reporta No. 50-321/1977-05.

There was no effect upon p1blic health or safety due to this event.

i 1

t L

i I

e 7.

y w

.,-e,--