05000302/LER-1979-089-03, /03L-0:on 790922,remote Shutdown Indicator for Decay Heat Cooler Outlet Temp Failed.Caused by Failed Resistance Temp Detector DH-2-TE.Replaced W/Spare & Returned to Svc

From kanterella
(Redirected from ML19275A932)
Jump to navigation Jump to search
/03L-0:on 790922,remote Shutdown Indicator for Decay Heat Cooler Outlet Temp Failed.Caused by Failed Resistance Temp Detector DH-2-TE.Replaced W/Spare & Returned to Svc
ML19275A932
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 10/15/1979
From:
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19275A928 List:
References
LER-79-089-03L, LER-79-89-3L, NUDOCS 7910230549
Download: ML19275A932 (2)


LER-1979-089, /03L-0:on 790922,remote Shutdown Indicator for Decay Heat Cooler Outlet Temp Failed.Caused by Failed Resistance Temp Detector DH-2-TE.Replaced W/Spare & Returned to Svc
Event date:
Report date:
3021979089R03 - NRC Website

text

.

? Ii, t M

  • . 7. !

dr v :

+=;

e ac ronu x.d b UUd di,

t.

u.s.uuctcan accutarony couuission LICENSEE EVENT REPORT EXHIBIT A a.ns cournet stoco l 1 l-l 1 I.l@

crt: Asc rwer ca tves att atouiato i~ronuarios t

0 ;g l 1; 1 l1 ; 1 g - ; _ ; g 4

00;

0 i Q )F I Li q Rl PI 3 Igl 0 l 0 - 1 01 01 0 1 vetuas wt i.

uctss. %,

a uciss....

u -<

0 1 310 1 2 gl0 ; 9 ; 2l2 ; 7 g 9 gl1 ; 0 l 1; 5 7 l 9 lg Co***7 1

A.

," g Qi@l01 510t -1 u

. a. aar a

...u r c n a

.a

.i coc..r w,...

(VENT { Cairti n an enesaatt use vssces

At 0 in Mode 1, it was repc>rt that the remote shutdown indicator for "A"

I

Decay Heat cooler outlet temperature, DH-39-TT had failed.

This crearM

,n f

~

o 3

, event contrary to Technical Specification 3.3.3.5.

No effect upon the plant 9

or general public. This is ti.a second occurrence of this type reported.

Ref,

,erence LER 79-14.

g I

F5TTl i I

ass t c..

s..

..,7, s,

..u,,

Coot Coct

$49:0 8 C3*. cst.?:031 543;;;I swac::s y

lCl Fj @ W @ l El @ lII NIS ITl RI Ul@ W @ Qi @

oce..

...:.7

...sr,...

itt%f'888

  • t *C "? NC-CDCI

*3 N3 t. oc

@,a(ig,;

17 19 !

g

! O j 8[ 9 l gi 10l 3l 1Li

(---J di

,_1, u

2.

2 a

u 2

v,.:.ise

.. v.,= :t a

-.-.z..

.r ic,. r.

s :2 os :-

.cr,e

.ute..

r.

v Ar.

2:Tuasa tast va -c:

- c..s sus.'rr t:

.:=ri.*

iasas actics 11@

lNl@

l Z! @

! Bl O!4l Sl(

Q @4@

l Z i@

I4.s1@ 10101 01 1

  • J 43 u

as 22

  • J 0ut:ns t A:t:ss @

cAust cascaimcN As :

,ic lThe cause of this event is attributed to failed RTD DH-2-TE.

The RTD was re-I placed with a spare and returned to service at 1330.on 28 September 1979.

No further corrective action deemed necessary.

y 3 I f

ii. I

,a s.

or-e. irar.s @ E*Ed '

3::i.,:n:...ev.@

','r*Ts'~

, x t.

nws e,-,, +,,

I NA I

l._S.J@l o-e r, t o r L' l _I 11@ l 1I 010 I@

a so

'2 8,f,,,,,,

edi.g s,

7 tocar.,sc..tssA:nh a.:.sr :. a riserv h ]

.st a,a s. a t.t ts t NA l

NA l

L_]

LZJ@l

....o.ss.t...o.s.'!. is :,,...., @ NA m..

l l'Ill010iOl@l,ZJ@l

,3

.t.50 w t6.sj a.gs sweet.

315;...' Cs l

I oi ni ol@l

.. s i.

.o..,,,...,..m........

l R [Z_J@l NA O L.N, k:lh,'.....es @ n

} }OO Nd

- mw t /

/

NA i

i ;ei,i i

l jQ,

a <,

,a

,/ ]J. Cooper (90_4.) 795-6486 a s

.a

%4..acee g.2a

. est (SEE ATTACHED SUPPLEMENTARY INFORMATION SEEET) 7 910230 JQ I

1 SUPPLEMENTARY INFORMATION Report No.:

50-302/79-089/03L-0 Facility:

Crystal River Unit #3 Report Date:

15 October 1979 Occurrence Date:

22 September 1979 Identification of Occurrence:

"A" decay heat cooler outlet temperature indicator inoperable contrary to Technical Specification 3.3.3.5.

Conditions Prior to Occurrence:

Mode 1 power operation (100%).

Description of Occurrence:

At 0230 it was reported that the remote shutdown indicator for "A" decay heat cooler outlet temperature, DH-39-TI had failed.

Further investiga-tion revealed that RID DH-2-TE had failed. Maintenance restored opera-bility and the indicator was returned to service at 1330 on 28 September 1979.

Designation of Apparent Cause:

I e cause of this event is attributed to a failed RTD, DH-2-TE.

Analysis of Occurrence:

No effect upon the plant or general public.

Corrective Action

The RTD was replaced with a spare and returned to service. No further corrective action deemed necessary.

Failure Data:

This is the second occurrence of this type reported.

Reference LER 79-14.

/rc 1188 303