Forwards LER 79-001/03L-0
ML19261B183
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 01/25/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19261B184 List:
References
NJK-79-40, NUDOCS 7902140143
Download: ML19261B183 (1)


Text

Dbl

. Cuad Cities Nuclear Power Station

  • @ Commonwealth Edison 22710 206 Avenue North Cordova, Illinois 6'242

- Telephone 309/654-2241 N J K-79-40 January 25, 1979 J. Keppler, Regional Director Of fice of Inspection and Enforcement Region lil U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Reference:

Quad-Cities Nuclear Power Station Docket No. 50-265, DPR-30, Unit 2 Appendix A, Sections 3 7.B.1 and 6.6.B.2.b.

Enclosed please find Reportable Occurrence Report No. R0 79-01/03L for Quad-Ci ties Nuclea r Power Station.

This report is submitted to you in accordance with the requirements of Technical Specification 6.6.8.2.b, as a condition leading to operation in a degraded mode permitted by a limiting condition for operation.

Very truly yours, COMMONWEALTH EDIS0N COMPANY QUAD-CITIES NUCLEAR POWER STATION

'l s7rya ffawxd/

N.J. Kalivianakis Station Superintendent NJK/JCV/cb cc: R.F. Janecek 21979 1/

00 7902140Iq3 9' \

S