05000302/LER-1979-100-03, /03L-0:on 791019,monthly Core Flood Tank Boron Analysis Surveillance Not Completed.Caused by Procedure Deficiency in Chemistry Surveillance Schedule.Revision to Surveillance Procedure SP-713 Implemented

From kanterella
(Redirected from ML19260A413)
Jump to navigation Jump to search
/03L-0:on 791019,monthly Core Flood Tank Boron Analysis Surveillance Not Completed.Caused by Procedure Deficiency in Chemistry Surveillance Schedule.Revision to Surveillance Procedure SP-713 Implemented
ML19260A413
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 11/08/1979
From: Cooper J
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19260A408 List:
References
LER-79-100-03L, LER-79-100-3L, NUDOCS 7911210073
Download: ML19260A413 (2)


LER-1979-100, /03L-0:on 791019,monthly Core Flood Tank Boron Analysis Surveillance Not Completed.Caused by Procedure Deficiency in Chemistry Surveillance Schedule.Revision to Surveillance Procedure SP-713 Implemented
Event date:
Report date:
3021979100R03 - NRC Website

text

-

u.s.NucuAa macus.Arcar comusssacN I

Nac romu :ss

' UCENSEE EVENT REFCRT EXHISIT A c.rn ccNract. succc 1 i

1 I

I I

I@

truAss ra:Nr ca nos au.ascusato mecaurr:cNa 4

0 1 0-l - 1 0[0:0lOjo(

0;0;gj

iIll1;gl_g_;g a

t g

l ? I LI Q 3.\\ ?! 3 Igl3 oIi s

v.:va n coca i.

wca.n e ssa

s
s caws v s.a si r 24 i

i a

g l LQL ! 5 01 -to i 3:01 2 Gl1 ( 0 l 1191 71 9'@l 1! 11 018 I 7 I 9 l@

ecN r O

oei 64 43 ty gmt gary 14 71 a4PCMT 3 Art 40 M

en

ccgg7 %wvs4 A 7

EVENr cEsCAIMcN ANQ PacSA3M CcNsEcuENC1s h At 1430, in Mode 1, it was determined that monthl-core flood tank boron f

o,:

analysis surveillance was not completed for either "A" or "B" core flood tank. f

,,3

, This created an event contrary to Technical Specification 3.5.1.

Redundancy l

, NA.

No effect upon the plant or general public.

Subsequent analyses revealed ;

that "A" and "B" core flood tank boron concentrations were within specification 4

This is the first occurrence of this tvoe reported.

f 2,,,

f 2..

i 44

,J.%

a:m.

sn'."

=

.sm, c=...,1 =.

IG I z i@ l zl @

I al st@ W@ l zi@ is ic i ci tri vi 1 ai, u

=

et=.,cs

...e.,

- c-

...,c..,..m c=ce a.

s a *o.

imrm.

@,,u,,o 17 19 I l-I i11010 1 1/l I OI3 I ILi 8

Q a,ig,ar

._2, a

u 2.

v

=

a a

u a

C Q'e f

C

Cy m s !! ' ska Fqm A 34sS.

4 nd A

84A I G T@l zi@

l z l@

W@

l 01010 I I

O@

lNf@

l Z l@

Iz i 9 I 9 I 9 f(

u n

s v

.a y

sa a

.i

/

cAuss cascnimes ANo ccamsenvs Acmens phecauseofthisevent is attr outed to procedure deficiency.

An error in coret

, flood tank boron frequency of analyses was discovered in the Chem'istry Sur-e

,veillance schedule.

The error was corrected accordingly.

In addition, a

revision to SP-713 has been impleeented to alternate CFT "A" and CFT "B" boron (

, concentration analysis on a bi-weekly basis.

% m;nts QWtmS,.fus gis v

  • sccvgpv 213CP'87'04

$@fus@ l 1l0 l0 l@ l NA l

l Af@lTechnicianobservation iis as as ao u

u s 4,.,.,..g.,,,

. ~.. m e l oms....uu, @

7 i.

..u

... u.,.

NA

[

NA J

i zi @ tz.!@l r

,i.

F G 9 la 1e as 89 g.

,tRsC'%46 E1L8Csunt3 Weset s

?v't ts:SNT'C9 3r

-,n

,n i ir I I "l Og L3gg O

l

.ses, 'J,w'Au

=uc,-c@

D wm.

h l

l 0101 Ol@l N3

{-

t i3 DV" 3.

7

. 3 in t;

' 038 c. CA Cava..;. 7, 8Acum

[

~t

ss.:u,o I

i tal W @l NA i

1380

'33

~ac== c~ u i

m,qi.1.. e @

O I

'l I I'I f I ' I I I I I l

#9 Wgl NA

&j j ",

  1. 098#' J*

, c sa. (904) 795-6486 f

%Avs cs,.gpAnga

/.

" ' - ~ ~ - - - -.

(NZ E' TAC'EED SL*??TN"'CA3I Er501CiCICH a - -J 1() gQ3

s SUPPLEMENTARY INFORMATION Report No.-

50-302/79-100/03L-0 Facility:

Crystal River Unit #3 Report Date:

8 November 1979 Occurrence Date:

19 October 1979 Identification of Occurrence:

Core flood tanks "A" and "B" inoperable contrary to Technical Speci-fication 3.5.1.

Conditions Prior to Occurrence:

Mode 1 power operation (100%).

Description of Occurrence:

At 1300 it was discovered by Chem / Rad personnel that a potential problem involving core flood r,nk boron analysis existed.

Actions were taken immediately to an:

' core flood tank "A" and "B" boron concentration.

Further inve4 tion revealed that the r]nthly core flood tank boron analyses hau..c. been performed on either "A" or "B" core flood tank.

This event was reported to the shift supervisor at 1430. Subsequent sample results obtained at 1435 revealed that the boron concentration for both "A" and "B" core flood tank were within specification.

Designation of Apparent Cause:

The cause of this event is attributed to procedure deficiency.

An error in core flood tank boron frequency of analyses was discovered in the chemistry surveillance schedule.

Analysis of Occurrence:

No effect upon the plant or general public.

Subsequent analyses re-vealed that both CFT "A" and CFT "B" were within boron concentration specification.

Corrective Action

The error in the surveillance schedule was corrected.

In addition, a revision to SP-713, RC Support Systems' Chemistry Surveillance Program, has been implemented to alternate CFT "A" and "B" boron concentration analysis on a bi-weekly basis.

Failure Data:

This is the first occurrence of this type reported.

/rc

/

/,- 4 si

\\

a

's