ML19256B525

From kanterella
Jump to navigation Jump to search

Forwards IE Bulletin 79-15, Deep Draft Pump Deficiencies. Action Required
ML19256B525
Person / Time
Site: Beaver Valley
Issue date: 07/11/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Dunn C
DUQUESNE LIGHT CO.
References
TAC-7240, NUDOCS 7907270329
Download: ML19256B525 (1)


Text

sn Rtcy

  • /

o, UNITED STATES 7'::'o y 7).r,( ( 'g NUCLEAR REGULATORY COMMISSION 3

'A

'/. ' s REGION I 0, -

,Ibd

[

631 PARK AVENUE

't,

,o KING OF PRUSSIA, PENNSYLVANf A 19406 Julv 11, 1979 Docket No. 50-334 Duquesne Light Company ATTN:

Mr. C. N. Dunn Vice President Operations Division 435 Sixth Avenue Pittsburgh, Pennsylvania 15219 Gentlemen:

The enclosed Bulletin No. 79-15 ic G rwarded to you for action.

A written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, 7

Boyce H. Grier Director

Enclosures:

1.

IE Bulletin No. 79-15 w/Attace.ments 2.

Listing of IE Bulletins Issued in Last Twelve Months cc w/encls:

F. Bissert, Technical Assistant Nuclear R. Washabaugh, QA Manager J. Werling, Station Superintendent G. Moore, General Superintendent, Power Stations Department J. J. Carey, Nuclear Technical Assistant f) 7 907270 Yi9 p

4

ENCLOSURE 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No. 79-15 Date:

July 11, 1979 Page 1 of 3 DEEP DRAFT PUMP DEFICIENCIES Description of Circumstances:

On October 20, 1978, Commonwealth Edison Company reported that manufacturing deficiencies had been identified in new high pressure core spray, low pressure core spray, and residual heat removal pumps manufactured by Ingersoll-Rand (I-R)

Company, Cameron Pump Division.

Each of these pumps is a vertical turbine pump with impellers located in bowls in a sump or a self contained barrel.

The motor (prime mover) is located at the highest pump elevation to take into account maximum flooding at the site or space considerations.

The suction is at the lower end of the pump while the discharge head is just below the driver.

Bearings supporting the vertical shaf t segments (usually 5 to 10 segments) are either self lubricated, force fed (lubricated by fluid being pumped), or oil lubricated and maintained within their own isolated system.

These pumps are designated as " Deep Draft".

Figures 1&2 show typical outlines of such pumps.

The internal deficiencies, identified through dimensional and visual inspections were as follows:

Low Pressure Core Spray Pumps (I-R Model No. 29APKD-5) (Date of Manufacture -

Feburary 1973)

Loose impeller bolts and bolts improperly staked Loose key - keyway fit Excessive runout on pump shaft Bearing showed wear Bearing clearance exceeded recommended tolerance Coupling thread galled Wear ring clearance out of-specification Impeller-to-shaft clearance out of specification Cracks found in second-and-third-stage impellers Stuffing box bushings were severely galled High Pressure Core Spray Pumps (I-R Mod September 1972)

Bearing clearance exceeded recommend DUPLICATE DOCUMENT Wear ring clearance out-of-specifica Bearings showed wear Entire document previously entered into system under:

ANO_ 998 7/9 Q & $

No. of pages:

7