NRC F ORM 366 U. b. NUL.L t AH h WULA10H Y COMMintuN (7 ??)

, LICENSEE EVENT REPORT l

CONTROL BLOCK: l 1

l l l l 6

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 7 0 1 8 9 lMlDIClClNl1l@l0l0l-l0l0l0 LICENSEE CODE 14 15 LICENSE NUV8ER 0 I O l - l 010 25l@l264 l 1LICENSE l 1 11 l 1 l@l57 CAT TVPE JO l

$8 l@

CCN'T 7

o 1 8

5ouRC lLl@l0 60 61 5101010131117l@l01810161719l@l'0181311 DOCKET NUMBER tid 69 EVENT DATE 74 75 REPORT DATE 7 9l@ 80 EVENT DESCRIPTION AND PROSABLE CONSEQUENCES h o 2 l At 0945.12 charoinn nirn was niaced nur nf service because.of nump trios due to l la 3 I low suction pressure and unsuccessful attempts to restart the puros and maintain l lo !. I it in operation. Placina this oumo out of service reduced the number of ooerable 1

[o s I chargino cumps to one (as number 11 charoino cumo was isolated because of a packing i o s Ileak). #11 charcina pumo was reoaired and olaced back into service at 1530 on 8/6/79,1 0 7 l briGCin0 the number of ODerable Dumos to two as reOuired bV I.S.3.1.2.4. #13 I o a l charging pumo remained operable durino event. This is not a recetitive occurrence. I 7 8 9 80 C DE CO E SLBCO E COMPONENT CODE SL B CO C'E S E 7

O 9J 8

l P l C10 l@

9 11 E l@ l F l@ l Il Nl Sl Tl Rl Ul@ [ E l@ l Z l@

12 13 18 19 20

,_ S E QUE NTI A L OCCURAENCE REPORT REVISION tgp AO EVENTVEAR REPORT NO. CCDE TYPE N O.

@ gPay l217 22l9 l l-23

[0 l3 2l 24 26 l/l 27 l0l3l lLl l-l l0 l

_ 28 29 30 31 32 TA N A T ON ON PLANT M T HOUPS 22 S B .T FOR B. S DLIER MANUFAC URER LAJ@Lzjg 33 a4 iz lg iz ig Jb 36 37 0 0 0l 40 i i Njg i Nig iA ;g l Al 5l 0l 1lg 41 42 44 47 43 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h iie l112 chargine pumo low suction oressure trios were cause by a faulty pressure l

, i in'dicatino switch: 1-PC-224Y. This Ashcroft nodel 1379 TAXEF was recaired by I

, , replacement of gauge internals which were worn. This is being considered as an [

, 3 l isolated failure and no further corrective action is to be taken. I i 4 I I 7 8 9 80 STA 5  % POWER OTHE R STATUS ISCOV RY DISCOVERY OESCRIPTION s W @ l0 18 l7 lg l NA l l A lgl Operator Observation l

' ACTivi TY CO' TENT 8 ELE 4 SED OF RELE ASE LOCATION CF RE LE ASE i 6 LZJ @ Iz igi AMOUNT N 1F ACTIVITYl l NA l 7 a 9 10 it 44 45 80 PEM50%EL E XPOSUAE$

NUYRER Tvpf

[i l i l l 0 l 0 l 0j@l z l@lCESCRIPTION NA

  • mon, l

,E m ov. E L i m'n', E S

'2 u 80 g,,

NtYaE R cEScRiPriONh ,

6a G o, U b

[. 8 9[0l0l0l@l 7 11 12 NA n,_m u

_ , _ _ l JU ) 30 ton cF CA O AYAGE TO F ACIL:TY g ,7,g,mc-T'ON 7 4 9 'O 33 a _ u. 2 190914o 9pp  ;

'3 e

r. g  ;,p r i g ,

LehJa 3l'Z I6L "A I Illilllitilil!

7 :C CB 69 i;

.m/ E v m E o r. m n R. P. Heibel/P. G. Pizzo Pecse (301) 224-7M2/7986 9

-3