PRODUCT SELECTION GUIDE Industrial Insulation

InsulThin HT Hydrophobic Microporous Blanket Insulation AVAILABLE SHAPES AND SIZES Roll Size

Roll Weight

Dimensions 36 Wide

45lbs

10mm x 36 x 25 5mm x 36 x 50 60 Wide

75lbs

10mm x 60 x 25 5mm x 60 x 50 THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.189

0.027 200ºF / 93ºC

0.195

0.028 400ºF / 204ºC

0.213

0.031 600ºF / 316ºC

0.237

0.034 SPECIFICATION COMPLIANCE ASTM C1676 Material Specification - Passes ASTM C1617 Corrosion - Passes ASTM C665 Corrosivity to Steel - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics - Flame Spread-0, Smoke Developed-0 For more information, refer to product data sheet IND-700 InsulThin HT is a high-temperature, hydrophobic, thin, flexible, microporous blanket insulation. Microporous insulation is a highly efficient insulation material and has been in service in a variety of industrial and commercial insulation applications for more than 35 years.

Operating Temperature Limit: 1200°F (650°C)

Thermo-1200' Calcium Silicate Pipe & Block Insulation Thermo-1200'* is a water-resistant, molded, high-temperature, abuse-resistant pipe and block insulation composed of hydrous calcium silicate. Recommended for use in the industrial processing and power generation industries. Integral to Thermo-1200' is XOX Corrosion Inhibitor, a distinctive formula and process that actively inhibits corrosion to outside surfaces of pipe and equipment.

Operating Temperature Limit: 1200°F (650°C)

AVAILABLE SHAPES AND SIZES Form

Pipe Size in/mm

Thickness in/mm Pipe Insulation

1/2 - 24 / 15-600

1-3 / 25-76 Quad Segments

20-37 / 500-925

1 1/2-3 / 38-76 Hex Pipe Covering

38-52 / 950-1300

1 1/2-3 / 38-76 Curved Segments30-126 / 700-3200

1 1/2-3 / 38-76 3-V Scored Block

30 min / 750 min

1 1/2-4 / 38-102 Beveled Lags

126 min / 3200 min

1 1/2-3 / 38-76 Flat Block

Flat Surface

1-4 / 25-102 THERMAL PERFORMANCE ASTM C335 (PIPE)

ASTM C518 (FLAT)

Mean Temp.

Btu.in/(hr. ft2. 0F)

W/mºC

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

.344

.050

.355

.051

200ºF / 93ºC

.389

.056

.373

.054 300ºF / 149ºC

.437

.063

.397

.057 400ºF / 204ºC

.486

.070

.428

.062 500ºF / 260ºC

.538

.078

.465

.067 600ºF / 316ºC

.591

.085

.509

.559 700ºF / 371ºC

.647

.093

.559

.081 SPECIFICATION COMPLIANCE ASTM C533 Type I Material Specification - Passes ASTM C1617 Corrosion - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes For more information, refer to product data sheet IND-303

  • Thermo-1200' water resistant calcium silicate is not hydrophobic. Thermo-1200' is designed to be able to withstand short periods of rainfall without absorbing water in excess. The volume of water absorption depends on the duration of exposure and the amount of rainfall. The insulation is not meant to withstand extreme weather conditions without jacketing. While this new water resistant feature can be helpful during prolonged field installations, it is nevertheless recommended that an installer weatherproof and jacket the thermal insulation as soon as it is feasibly possible. Should water enter the system, the corrosion inhibitors will still activate to continue to help combat corrosion at a chemical level, and once the system reaches operating temperatures, the water will vaporize and leave the system.

THERMAL PERFORMANCE ASTM C335 (PIPE)

ASTM C518 (FLAT)

Mean Temp.

Btu.in/(hr. ft2. 0F)

W/mºC

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

.412

.059

.438

.063

200ºF / 93ºC

.481

.069

.476

.069 300ºF / 149ºC

.548

.079

.515

.074 400ºF / 204ºC

.611

.088

.557

.080 500ºF / 260ºC

.671

.097

.601

.087 600ºF / 316ºC

.728

.105

.646

.093 700ºF / 371ºC

.782

.113

.694

.100 AVAILABLE SHAPES AND SIZES Form

Pipe Size in/mm

Thickness in/mm Pipe Insulation

1/2 - 24 / 15-600

1-4 / 25-102 Quad Segments

24 - 40 / 600-1000

1 1/2-3 / 38-76 Scored or V-Grooved Block

30 min / 750 min

1 1/2-4 / 38-102 Flat Block

Flat Surface

1-4 / 25-102 SPECIFICATION COMPLIANCE ASTM C610 Material Specification - Passes ASTM C1617 Corrosion - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes For more information, refer to product data sheet IND-200 Sproule-1200' is a preformed, high-temperature, non-wicking pipe and block insulation composed of expanded perlite that is uniformly reinforced with a high-strength fiber. Integral to Sproule-1200' is XOX Corrosion Inhibitor, a distinctive formula and process that actively inhibits corrosion to outside surfaces of pipe and equipment.

Operating Temperature Limit: 1200°F (650°C)

Sproule-1200' Expanded Perlite Pipe & Block Insulation 2

MinWool-1200 Field-Formed Pipe Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness

Single Layer: 11/2-4 thick Double Layer: Over 4 thick in 1/2 increments Pipe Size: 21/2-72 Available in NPS pipe sizes and copper tubing sizes THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.044 400ºF / 204ºC

0.44

0.064 600ºF / 316ºC

0.62

0.090 SPECIFICATION COMPLIANCE ASTM C547 Material Specification Types III - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics - Flame Spread - 25, Smoke Developed - 50 or less For more information, refer to product data sheet IND-420 MinWool-1200 Field-Formed Pipe insulation is made of inorganic fibers derived from basalt, a volcanic rock. It is made with a thermosetting resin binder. Field-Formed Pipe insulation is a factory V-grooved mineral wool board with a unique contact adhesive in the grooves. It is manufactured to specific pipe sizes with a variety of facing options. It ships flat and allows for easy forming at the job site.

Operating Temperature Limit: 1200°F (650°C)

MinWool-1200 Pipe Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Form

Pipe Size in/mm

Thickness in/mm One Piece

1/2 - 6 / 15-152

1-6 / 25-152 Two Piece

7-24 / 175-600

1-6 / 25-152 Four Piece

25-44 / 625-1100

1-6 / 25-152 (1/2 increments)

THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.23

0.033 200ºF / 93ºC

0.28

0.040 400ºF / 204ºC

0.40

0.058 600ºF / 316ºC

0.56

0.081 SPECIFICATION COMPLIANCE ASTM C547 Material Specification Types I, II, IV - Passes ASTM C665 Corrosivity to Steel - Passes BS EN 13472 Short-Term Water Absorption For more information, refer to product data sheet IND-401 MinWool-1200 Pipe is a water-repellent pipe insulation made of inorganic fibers derived from basalt, a volcanic rock. It is made with a thermosetting resin binder. Advanced manufacturing technology ensures consistent product quality, with high fiber density and low shot content, for excellent performance in high-temperature, thermal control and fire-resistant applications.

Operating Temperature Limit: 1200°F (650°C)

MinWool-1200 Preformed Pipe Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness

Single Layer: 1-4 thick Double Layer: Over 4 thick in 1/2 increments Pipe Size: 1/2 - 36 Available in iron and copper tubing sizes THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.044 400ºF / 204ºC

0.44

0.064 600ºF / 316ºC

0.62

0.090 SPECIFICATION COMPLIANCE ASTM C547 Material Specification Types III - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics - Flame Spread - 25, Smoke Developed - 50 or less For more information, refer to product data sheet IND-423 MinWool-1200 Preformed (PF) Pipe insulation is made of inorganic fibers derived from basalt, a volcanic rock. It is made with a thermosetting resin binder. PF Pipe insulation is a factory V-grooved mineral wool board that is formed to specific pipe sizes and provided in half cylinder sections with a variety of facing options.

Operating Temperature Limit: 1200°F (650°C) 3

MinWool-1200 Lamella Tank Wrap Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness

Single Layer: 1-4 thick Facings Available

Standard is fiberglass mat Available with ASJ THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.29

0.042 200ºF / 93ºC

0.36

0.052 400ºF / 204ºC

0.54

0.078 600ºF / 316ºC

0.82

0.118 SPECIFICATION COMPLIANCE ASTM C1393 Material Specification / Complies ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics / Flame Spread - 25, Smoke Developed - 50 or less ASTM E136 Non-Combustible - Passes (mineral wool only)

For more information, refer to product data sheet IND-424 MinWool-1200 Lamella Tank Wrap is a flexible mineral wool wrap insulation. It is a lightweight, high-performance insulation for high-temperature applications. This insulation is produced to fit large diameter pipe, duct, tanks and equipment, ranging in temperatures from below ambient up to 1000°F continuous maximum service temperature.

Operating Temperature Limit: 1200°F (650°C)

MinWool-1200 Precision Cut Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness

Single Layer: 1-4 thick Double Layer: Over 4 thick in 1/2 increments Pipe Size: 1/2 -72 Available in iron and copper tubing sizes THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.044 400ºF / 204ºC

0.44

0.064 600ºF / 316ºC

0.62

0.090 SPECIFICATION COMPLIANCE ASTM C547 Material Specification Types III - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics - Flame Spread - 25, Smoke Developed - 50 or less For more information, refer to product data sheet IND-422 MinWool-1200 Precision Cut (PC) Pipe insulation is made of inorganic fibers derived from basalt, a volcanic rock. It is made with thermosetting resin binder. PC Pipe insulation (without adhesive) is a factory V-grooved mineral wool board manufactured to specific pipe or vessel sizes with a variety of facing options. It ships flat in 4 mil plastic and allows easy forming at the job site.

Operating Temperature Limit: 1200°F (650°C)

MinWool-1200 Pipe & Tank Wrap Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Roll Length ft/m

Width in/m

Thickness in/mm 18 / 5.5

48 / 1.22

11/2 / 40 16 / 4.9

48 / 1.22

2 / 50 14 / 4.3

48 / 1.22

21/2 / 65 12 / 3.7

48 / 1.22

3 / 75 10 / 3.1

48 / 1.22

31/2 / 90 8 / 2.4

48 / 1.22

4 / 100 THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.23

0.033 200ºF / 93ºC

0.28

0.040 400ºF / 204ºC

0.40

0.058 600ºF / 316ºC

0.56

0.081 SPECIFICATION COMPLIANCE ASTM C553 Mineral Fiber Blanket Specification Types I, II,III,IV, V, VI - Passes ASTM C665 Corrosivity to Steel - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics / Flame Spread - 25, Smoke Developed - 50 or less ASTM E136 Non-Combustible - Passes (mineral wool only)

For more information, refer to product data sheet IND-415 MinWool-1200 Pipe & Tank Wrap insulation is made of inorganic fibers derived from basalt, a volcanic rock. It is made with a thermosetting resin binder. Advanced manufacturing technology ensures consistent product quality, with high fiber density and low shot content, for excellent performance in high-temperature, thermal control and fire-resistant applications.

Operating Temperature Limit: 1200°F (650°C)

Facings Available

Sizes 1/2 - 2 are supplied with no facing Sizes 21/2 and above are supplied with a fiberglass mat facing Other facings available include: ASJ and FSK 4

MinWool-1200 Metal Mesh Blanket Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness

Single Layer: 1-4 thick in 1/2 increments Standard Width: 24 Standard Length: 48 THERMAL PERFORMANCE*

Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.043 400ºF / 204ºC

0.42

0.061 600ºF / 316ºC

0.56

0.081 SPECIFICATION COMPLIANCE ASTM C592 Specification of Metal Mesh Covered Blanket Type I,II,III - Complies ASTM C665 Corrosivity to Steel - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes

  • Thermal Performance listed for 1280 density only - for other densities and more information, refer to product data sheet IND-406 MinWool-1200 Metal Mesh Blanket (MMB) insulation is made of inorganic fibers derived from basalt, a volcanic rock, with a thermosetting resin binder. MMB is a mineral wool blanket available with a variety of metal mesh options mechanically applied to one or both surfaces.

Operating Temperature Limit: 1200°F (650°C)

MinWool-1200 Industrial Board Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Nominal Densities (lb/ft3/kg/m3) Sizes in/mm

Thicknesses in/mm 1240 (4 / 48)

24 x 48 / 610 x 1219 1-4 / 25-102 1260 (6 / 96)

36 x 48 / 914 x 1219 (All Densities) 1280 (8 / 128)

(All Densities)

Foil Scrim Polyethylene 1210 (10 / 160)

(FSP) facing may be 1212 (12 / 192)

available on a made-to-order basis THERMAL PERFORMANCE*

Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.043 400ºF / 204ºC

0.42

0.061 600ºF / 316ºC

0.56

0.081 SPECIFICATION COMPLIANCE ASTM C612 Material Specification - Complies ASTM C665 Corrosivity to Steel - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes

  • Thermal Performance listed for 1280 density only - for other densities and more information, refer to product data sheet IND-402 1 thickness available in 8#, 10# and 12# densities only MinWool-1200 Industrial Board insulation is made of inorganic fibers derived from basalt, a volcanic rock. It is made with a thermosetting resin binder. Advanced manufacturing technology ensures consistent product quality, with high fiber density and low shot content, for excellent performance in high-temperature, thermal control and fire-resistant applications.

Operating Temperature Limit: 1200°F (650°C)

MinWool-1200 Flex Batt Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Nominal Densities (lb/ft3/kg/m3) Sizes in/mm

Thicknesses in/mm 1240 (4 / 48)

24 x 48 / 610 x 1219 1-4 / 25-102 1260 (6 / 96)

36 x 48 / 914 x 1219 (All Densities) 1280 (8 / 128)

(All Densities)

1210 (10 / 160)

1212 (12 / 192)

THERMAL PERFORMANCE*

Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.043 400ºF / 204ºC

0.42

0.061 600ºF / 316ºC

0.56

0.081 SPECIFICATION COMPLIANCE ASTM C612 Material Specification - Complies ASTM C665 Corrosivity to Steel - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes

  • Thermal Performance listed for 1280 density only - for other densities and more information, refer to product data sheet IND-406 1 thickness available in 8#, 10# and 12# densities only MinWool-1200 Flexible Batt insulation is made of inorganic fibers derived from basalt, a volcanic rock. It is made with a thermosetting resin binder. Advanced manufacturing technology ensures consistent product quality, with high fiber density and low shot content, for excellent performance in high-temperature, thermal control and fire-resistant applications.

Operating Temperature Limit: 1200°F (650°C) 5

Super Firetemp High-Temperature Insulation AVAILABLE TYPES AND SIZES Types

Board Dimensions

Thickness in/mm Super Firetemp L

4ft x 8ft

3/4 - 3 / 13 - 76 Super Firetemp M

4ft x 8ft

1/2 - 3 / 13 - 76 Super Firetemp H

4ft x 8ft

1/2 -2 / 13 - 51 Super Firetemp X

4ft x 8ft

1/2 - 2 / 13 - 51 Super Firetemp S

4ft x 8ft

1/2 - 11/2 / 13 - 38 (1/2 increments)

AVAILABLE DENSITIES Type

Density (Avg.)

ASTM C656

Super Firetemp L

20 pcf (288 kg / m3)

Type II, Grade 5 Super Firetemp M

28 pcf (449 kg / m3)

Type II, Grade 6 Super Firetemp H

35 pcf (561 kg / m3)

Type II, Grade 6 Super Firetemp X

40 pcf (641 kg / m3)

Type II, Grade 7 Super Firetemp S

55 pcf (881 kg / m3)

Type II, Grade 8 SPECIFICATION COMPLIANCE ASTM C795 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes For more information, refer to product data sheets:

IND-103(L), IND-104(M), IND-105(H), IND-106(X), IND-107(S)

Super Firetemp boards are inorganic, high-temperature boards with exceptional strength and insulating qualities, produced in various densities. Super Firetemp boards are suitable for fire protection applications, refractory backup, and can be machined into component parts of many shapes and sizes.

Continuous Temperature Limit: Varies by product type MinWool-1200 Mitered Fittings Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness

Single Layer: 1-4 thick Double Layer: Over 4 thick in 1/2 increments Sizes available up to a 72 IPS but vary by thickness Available in NPS pipe sizes and copper tubing sizes THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 100ºF / 38ºC

0.25

0.036 200ºF / 93ºC

0.30

0.044 400ºF / 204ºC

0.44

0.064 600ºF / 316ºC

0.62

0.090 SPECIFICATION COMPLIANCE ASTM C547 / C585 MICA Fabrication Standards - Complies ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E84 Surface Burning Characteristics - Flame Spread - 25, Smoke Developed - 50 or less For more information, refer to product data sheet IND-419 MinWool-1200 Mitered Fittings are made of inorganic fibers derived from basalt, a volcanic rock. It is made with thermosetting resin binder. These mitered and bonded fittings are for standard short and long radius and non-standard radius sweep elbows found in normal piping schemes. Fittings are manufactured from MinWool-1200 Preformed Pipe Insulation and mitered into precision segments.

Operating Temperature Limit: 1200°F (650°C)

Super Caltemp Gold 1700 Calcium Silicate Pipe & Block Insulation AVAILABLE SHAPES AND SIZES Form

Pipe Size in/mm

Thickness in/mm 3-V Scored Block

30 min / 750 min

1 1/2-3 / 38-76 Flat Block

Flat Surface

1-3 / 25-76 THERMAL PERFORMANCE Mean Temperature

Btu.in/(hr. ft2. 0F)

W/mºC 200ºF / 93ºC

0.54

0.078 400ºF / 204ºC

0.61

0.088 600ºF / 315ºC

0.67

0.097 800ºF / 427ºC

0.73

0.105 SPECIFICATION COMPLIANCE ASTM C533 Type II Material Specification - Passes ASTM C795 / C871 / C692 Corrosion Austenitic Stainless Steel - Passes ASTM E136 Non-Combustible - Passes For more information, refer to product data sheet IND-305 Super Caltemp Gold 1700 block is an inorganic, non-combustible, high-temperature insulation that is composed primarily of hydrous calcium silicate. The insulation is tailored for systems operating up to 1700°F (927°C). Super Caltemp Gold 1700 meets or exceeds the physical and thermal property requirements of ASTM C533, Type II.

Operating Temperature Limit: 1700°F (927°C)

Facings Available

Sizes 1/2 - 2 are supplied with no facing Sizes 21/2 and above are supplied with a fiberglass mat facing Other facings available include: ASJ and FSK 6

Insulkote ET Weather Protective Coating CalCoat-127 One Coat Finishing Cement Calbond Gold High-Temperature Glue Super Calstik High-Temperature Glue Developed as a high-quality protective coating, Insulkote ET is a compound of selected and processed bitumens and mineral fillers. It is recommended for weather-protecting insulated vessels, tanks, piping, equipment and duct work. Insulkote ET is a non-vapor barrier, weather-proof coating for use over thermal insulation where breathing is required.

For more information, refer to product data sheet IND-10 CalCoat-127 is a proprietary blend of hydraulic cement, calcium silicate and inorganic mineral fibers with corrosion inhibitors that provides a smooth finish over high-temperature insulation. CalCoat-127 is recommended for finishing use with calcium silicate or perlite insulation in high-temperature piping and equipment applications.

For more information, refer to product data sheet IND-13 CalBond Gold is a modified, silicate-based glue for thermal insulations. It sets quickly to provide a high-temperature bond for porous insulating materials.

CalBond Gold is useful for bonding sections of calcium silicate or perlite high-temperature pipe or block insulation and to make mitered elbows, large insulating sections or other special shapes.

For more information, refer to product data sheet IND-11 Super Calstik is a modified, silicate-based glue. It sets quickly to provide a high-temperature bond for porous insulating materials. Super Calstik is used for bonding and sealing joints in Super Firetemp high-temperature insulation. It is used in walls, structural steel, cable trays and other fire-rated applications.

For more information refer, to product data sheet IND-108 Accessories Insulation Product Accessories 7

Technical specifications as shown in this literature are intended to be used as general guidelines only. Please refer to the Safety Data Sheet and product label prior to using this product. The physical and chemical properties of the products listed herein represent typical, average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Any references to numerical flame spread or smoke developed ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with the Regional Sales Office nearest you for current information.

All Johns Manville products are sold subject to Johns Manvilles standard Terms and Conditions, which includes a Limited Warranty and Limitation of Remedy. For a copy of the Johns Manville standard Terms and Conditions or for information on other Johns Manville thermal insulation and systems, visit www.jm.com/terms-conditions or call (800)654-3103.

717 17th St.

Denver, CO 80202 800-866-3234 JM.com

© 2019 Johns Manville All Rights Reserved IND-902 02/13/19 (Replaces 02/23/18)