ThyssenKrupp Materials NA, Inc.

MATERIAL SAFETY DATA SHEET SECTION I. MATERIAL IDENTIFICATION COMPANY RE-ISSUE DATE IDENTIFICATION NUMBER ThyssenKrupp Materials NA, Inc.

4-Dec-08 N/A 22355 West Eleven Mile Road Southfield, Michigan 48033 TRADE NAME EMERGENCY PHONE NUMBER PREPARED BY:

Micarta (248) 233-5681 J. VanValkenburg CHEMICAL NAME FORMULA DOT DOT IDENTIFICATION NO.

N/A Glass cloth, paper, silicon, phenolic & melamine epoxy composite N/A SECTION II HAZARDOUS INGREDIENTS MATERIAL OR COMPONENT

% COMPOSITION OSHA-PEL ACGIH TLV CAS NUMBER BY WEIGHT (1) 8-HR TWA 8-HR TWA PHENOL 108-95-2

<8-12 5.0 ppm 5.0 ppm 5.0 ppm 5.0 ppm FORMALDEHYDE 50-00-0

<2

.75 ppm

.30 ppm METHANOL 67-56-1

<10-11 200 ppm 200 ppm MOLYBDENUM/

1317-33-5 10 mg/m3 10 mg/m3 DISULFIDE SILICA 60676-86-0 0.1 mg/m3 0.1 mg/m3 SILICON 7440-21-3 5.0 mg/m3 10.0 mg/m3 CRESYLIC ACID N /A

<4 5 ppm 22.0 mg/m3 This product is a thermostatic composite consisting of a cured phenol-formaldehyde on a cellulose substrate. OSHA PEL and ACGIH TLV have not been established for this material. Formaldehyde has been designated a carcinogen on the following lists: NTP/IARC/OSHA Precautions must be taken when formaldehyde is present In the air at concentrations greater than 0.1 ppmas described in the standard.

Micarta products may be comprised of all or variations of the ingredients shown here.

PEL=Permlsslble Exposure Limit (1) % of Alloying Material Vanes with Grade of Material. Other trace elements of <1% May be in Present.

SECTION Ill. PHYSICAL DATA MATERIAL (At Normal Conditions)

APPEARANCE AND ODOR SOLID Flat or shapes - natural in color - slight phenolic odor MELTING POINT SPECIFIC GRAVITY N/A 1.3 -1.4 SECTION IV. FIRE AND EXPLOSIVE SPECIAL FIRE FIGHTING PROCEDURES:

Same as for wood fire - do not breathe fumes from burning laminate.

SECTION V. REACTIVITY DATA STABILITY CONDITIONS TO AVOID Stable Strong Oxidizing agents HAZARDOUS DECOMPOSITION PRODUCTS Carbon dioxide, carbon monoxide, phenols, methane, formaldehyde & hydrocarbons Dust Or Fumes May Be Produced During Welding, Burning, Grinding And Possibly Machining. Refer To ANSI Z49.1 SECTION VI. Environmental SPILL OR LEAK PROCEDURES N/A WASTE DISPOSAL METHODS Disposal must comply with applicable Federal, State and Local disposal and discharge laws.

SECTION VII. HEALTH HAZARD DATA NOTE:

MICARTA PRODUCTS IN THEIR NATURAL STATE DO NOT PRESENT AN INHALATION OR CONTACT HAZARD, HOWEVER OPERATIONS SUCH AS BURNING, WELDING, SAWING. BRAZING AND GRINDING MAY RELEASE FUMES AND/OR DUST WHICH MAY PRESENT HEALTH HAZARDS EFFECTS OF OVEREXPOSURE:

Acute Dust or fume may cause irritation to the eyes, nose, or throat. Inhalation of Formaldehyde dust or fume may cause cancer.

Chronic A very small number of exposed people may develop an allergic reaction after prolonged or repeated exposure.

Phenol Exposure may cause skin irritation and liver and kidney damage.

Formaldehyde Exposure may cause irritation to the eyes, skin and respiratory system. Formaldehyde is designated a carcinogen on the NTP/IARC/OSHA.

Methanol Methanol has tested positive for carcinogenicity in rodents.

Molybdenum Exposure may cause skin and respiratory irritation, and liver and kidney damage.

Disulfide Silica Exposure may cause skin and respiratory Irritation. Silica crystalline as a respiratory dust has caused lung cancer in animals.

Silicon An accumulation of Silicon in the lungs may result in benign pneumokoniosis.

Cresylic Acid Exposure may cause skin and respiratory irritation, and liver and kidney damage.

SECTION VIII. EMERGENCY AND FIRST AID PROCEDURES Inhalation In the event of excessive exposure to dust or fume, remove the employee to fresh air. If breathing is difficult administer artificial respiration or oxygen. Obtain immediate medical assistance.

Skin:

Abrasions and cuts should be washed and closed by a clean compress and be immediately medically treated. Should skin irritation occur, wash affected area with mild soap and rinse with clean warm water.

Eyes:

Depending on the type and nature of exposure, relief may be obtained by fresh air or rinsing the eyes with clean water. Obtain medical assistance.

Medical Conditions Aggravated by Exposure:

Persons with a predisposition to respiratory disorders may be adversely affected by particulates or respiratory irritants generated during the mfg. process.

SECTION IX. SPECIAL PROTECTION INFORMATION & CONTROL MEASURES Note:

Consult your regional codes or Code of Federal Regulations, Title 29, Part 1910. Subpart G-Occupational Health and Environmental Control, Subpart I Personal Protective Equipment. Subpart P-Welding, Cutting, and Brazing, and Subpart Z-Toxic and Hazardous Substances. Certain welding type activities may produce hazardous substances such as carbon monoxide, ozone, phosgene in the presence of certain chemicals, or produce Inert suffocating atmospheres in addition to the production of ultraviolet radiation and/or noise.

Ventilation:

Local exhaust or ventilation systems sufficient to maintain exposure levels to contaminates below prescribed limits may be required When inhalation controls are not sufficient to reduce the exposure below the applicable exposure limit then use OSHA/NIOSH approved respiratory protection within the use limitations of the respirator.

Personal To avoid contact use appropriate protective gloves or clothing to protect against cutting edges Appropriate heat shielding garments should be Protection:

used for activities using or generating heat. Eyes should be protected by using safetyglasses, goggles, helmet, face shield as appropriate to the operation Precautions to be taken in handling and storage:

Be alert to sharp edges and unsecured Iifts.

SECTION X. OTHER INFORMATION SARA Section 313 Toxic Chemical List, de minimis Concentrations This product does not contain toxic chemicals subject to the reporting requirements of Section 312 and 313 of Title Ill of the Superfund Amendments and Reauthorization Act of 1986 and 40 CFR Part 372.

NFPA Ratings (NFPA No. 704)

HEALTH 2

FLAMMABILITY 1

REACTIVITY 0

The Information in this MSDS was obtained from sources which we believe are reliable. However, the information is provided without any representation or warranty, expressed or implied, regarding the accuracy or correctness. The conditions or methods of handling, storage, use, and disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with handling, storage, use or disposal of the product. Data sheets of individual manufacturers are available upon request.