Ti 2595/2 Attachment i N

Page 1 of 2 OFFICE OF INSPECTION AND ENFORCI; MENT 136W SITE INSPECTOR DAILY REl' ORT Date 4/16/79 Site Oconce 1, 2, 3 Inspector (s)

G. A. Betiste B. T. Poon Cencral Plant Status:, All three units ocerating at accroximately full nouer.

la.

Review of Similar Transients (Item 2 of IES79-05A):

No change from April 12 report.

b.

Review and Revision of Operating and Maintenance Procedures (Items 3, 4, 5, 7, 8, 9, 10 of IEB 79-05A):

No change from April 12 report.

Review and Implementation of Changes in Containment c.

(Item 6 IEB 79-054A):

Isolation No change from April 12 report.

P00R MGMAL d.

Training of Plant Personnel (Itema 1, 4, 11 and plant / procedures changes):

No change from April 12 report.

r/g 20/- do-

. 9 07 C2 D IC'0 e

TI 2595/2 Oconee 1, 2, 3 Attachment !

Page 2 of 2 2.

S!!MMARY 0F NRC INSPECTION.\\CTIVITY DURING PERion 9:00a.n. 4/15 - 9:00a.n. 4/ir (Address items 1.a thru 2.d above, give other independent /significant effort, identify shifts on which activity was done during past 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

Conducted plant tour in plant vital areas including HPI, LPI, and feedwater system a eas and confirmed that ESF system valve lineups are in proper order Cloc'<ed open and closed, etc.)

Observed control room operation cay / swing shif t and nite / day shif t.

Reviewed 'hift control operators logs.

s 3.

STATUS OF IFlPECTOR DISCUSSIONS WITH PL\\NT PERSONNEL:

No change from April 15 report.

~ - "

4.

DESCRIPTION OF CENERAL PLANT STATliS (i.e., operating power level, planned changes, scheduled outages, ESF out of service, major maintenance, reportable occurrences, etc.)

Uni t

  • 1, 100%

fioESFequipmentcutofservice.

Unit 2, 99%

' No major maintenance.

Unit 3, 100%

267 070 h