ML19211D284

From kanterella
Jump to navigation Jump to search

Acceptance Review for Traveler TSTF-554, Revise Reactor Coolant Leakage Requirements
ML19211D284
Person / Time
Site: Technical Specifications Task Force
Issue date: 08/20/2019
From: Michelle Honcharik
NRC/NRR/DSS
To:
Technical Specifications Task Force
Honcharik M, NRR/DSS, 301-415-1774
References
EPID L-2019-PMP-181
Download: ML19211D284 (3)


Text

August 20, 2019 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD 20852

SUBJECT:

ACCEPTANCE FOR REVIEW REGARDING TRAVELER TSTF-554, "REVISE REACTOR COOLANT LEAKAGE REQUIREMENTS (EPID L-2019-PMP-0181)

Dear Members of the Technical Specifications Task Force:

By letter dated May 7, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19127A238), you submitted to the U.S. Nuclear Regulatory Commission (NRC) a request to incorporate Traveler TSTF-554, "Revise Reactor Coolant Leakage Requirements, into the standard technical specifications.

Section 170.21 of Title 10 of the Code of Federal Regulations requires that Travelers are subject to fees based on the full cost of the review. You requested a fee exemption, which was granted by letter dated July 8, 2019 (ADAMS Accession No. ML19156A036).

The NRC staff has completed a preliminary review of your submission and determined it is sufficiently complete and appropriate to initiate a more comprehensive review. The review will generally follow the schedule below.

MILESTONE SCHEDULE DATE Issue Request for Additional Information November 6, 2019 Issue Draft Safety Evaluation July 17, 2020 Issue Final Safety Evaluation December 18, 2020 If you have any questions, please contact me at (301) 415-1774 or via e-mail to Michelle.Honcharik@nrc.gov.

Sincerely,

/RA by Andrea Russell for/

Michelle C. Honcharik, Senior Project Manager Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation Project No. 753 cc: See next page

Technical Specifications Task Force Project No. 753 cc:

Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 Rockville, MD 20852 Attention: Brian D. Mann E-mail: brian.mann@excelservices.com James P. Miksa Entergy Nuclear Operations, Inc.

Palisades Nuclear Power Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Email: jmiksa@entergy.com Jordan L. Vaughan Duke Energy EC07C / P.O. Box 1006 Charlotte, NC 28202 Email: jordan.vaughan@duke-energy.com Ryan Joyce Southern Nuclear Operating Company 3535 Colondate Parkway / Bin N-274-EC Birmingham, AL 35243 Email: rmjoyce@southerncomcom David M. Gullott Exelon Generation 4300 Winfield Road Warrenville IL 60555 Email: David.Gullott@exeloncorp.com Wesley Sparkman Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-226-EC Birmingham, AL 35242 Email: wasparkm@southernco.com

ML19211D284 *concurred via e-mail NRR-106 OFFICE NRR/DSS/STSB/PM NRR/DSS/STSB/BC* NRR/DSS/STSB/PM NAME MHoncharik VCusumano MHoncharik (ARussell for)

DATE 8/16/2019 8/16/2019 8/20/2019